MPM04 overview

MPM04 is a component documented by Sanken electric. The PDF description identifies it as "Io=3A non-isorated step-down DC/DC Converter module." This guide condenses the most useful engineering information from the available PDF so that designers and sourcing teams can identify the checks that still need confirmation in the original document.

Datasheet snapshot

  • Manufacturer: Sanken electric
  • Part number: MPM04
  • Category: IC
  • Datasheet length: 12 Pages

Specifications and operating details

The following points were extracted from the PDF text. Check the associated conditions, notes and limits in the complete document before using a value in a design.

  • And than Vin(MIN)36V in 20V<V o<24V more than Vin(MIN)30V in 18V<V o<20V.
  • Pin Assignment Pin Symbol Function 1,3 GND Ground terminal 5,6,7 OUT Output terminal 8,9 SW Switching-Frequency-measurement Table 1 Io=3A non-isorated step-down DC/DC Converter module MPM00 Series SANKEN ELECTRIC CO., LTD.
  • Recommended operating conditions (6) Items Symbol Specifications Units Conditions Min Max Input voltage range VIN 9 40 V MPM01 (8) 16 40 MPM04 (9) Output current range (7) Io 0 3 A Junction temperature in operation Tjop -20 125 ℃ Output vo.
  • The recommended operating conditions means operating conditions required to maintain normal circuit functions fig.1 MPM00 series Load Table 2 Table 3 Io=3A non-isorated step-down DC/DC Converter module MPM00 Series SANKEN ELECTRIC CO., LTD.
  • Refer to the fig.6. (8).The minimum input voltage shall be either of 9V or VO+4V, whichever is higher. (9).The minimum input voltage shall be either of 16V or VO+4V , whichever is higher.
  • Electrical characteristics (Ta = 25℃) (10) Parameter Symbol Ratings Units Conditions Min typ Max Reference voltage VFBref 0.490 0.500 0.510 V VIN=33V ,Io=1A Efficiency (11) η - 91 - % VIN=33V,V o=12V ,Io=3A Switching frequency fo 212 250 2.
  • As for details, please refer to the fig.10. (13) At the time of setting the output voltages except V o = 12V , it should be noted that the OCP operation point may fluctuate from the values of V o = 12V because the inductance of the built-i.

Topics covered by the datasheet

The document includes sections related to:

  • Electrical Characteristics
  • Applications

Engineering review checklist

  • Check resistance value, tolerance, temperature coefficient and long-term stability over the operating range.
  • Derate continuous power for ambient temperature and verify pulse or surge capability separately.
  • Match the land pattern, termination finish and current-sense routing to the exact package option.

Always confirm values against the latest manufacturer-controlled datasheet, especially when qualifying a substitute or releasing a production BOM.