CLS13 overview

CLS13 is a component documented by Endress+Hauser Group Se. The PDF description identifies it as "Conductivity sensor for high-temperature applications 2022-06-30." This guide condenses the most useful engineering information from the available PDF so that designers and sourcing teams can identify the checks that still need confirmation in the original document.

Datasheet snapshot

  • Manufacturer: Endress+Hauser Group Se...
  • Part number: CLS13
  • Category: Sensor
  • Datasheet length: 8 Pages

Specifications and operating details

The following points were extracted from the PDF text. Check the associated conditions, notes and limits in the complete document before using a value in a design.

  • Your benefits Reliable and accurate measured values at low conductivities Optimized for high pressures and temperatures up to 250 °C (482 °F) Easy to clean thanks to stainless steel body and removable outer electrode Robust design for maxi.
  • Input Measured variables • Conductivity Temperature Measuring ranges Conductivity (in relation to water at 25 °C (77 °F)) CLS13 -A 0.04 to 20 μS/cm CLS13 -B 0.10 to 200 μS/cm Temperature CLS13 -20 to 250 °C (-4 to 480 °F) Power supply wiri.
  • Ensure that the electrodes are fully immersed in the medium during measurement.  The insertion depth must be at least 50 mm (1.97 in).
  • If using the sensor in the ultrapure water range: Work under air-evacuated conditions.  This prevents CO 2 in the air from dissolving in the water and increasing the conductivity by up to 3 µS/cm as a result of (weak) dissociation.
  • Environment Ambient temperature range –20 to 60 °C (–4 to 140 °F) Storage temperature -25 to +80 °C (-10 to +180 °F) Degree of protection IP67 Process Process temperature range -20 to 250 °C (-4 to 480 °F) Process pressure 1 to 41 bar (15.

Topics covered by the datasheet

The document includes sections related to:

  • applications
  • Ordering information

Engineering review checklist

  • Check resistance value, tolerance, temperature coefficient and long-term stability over the operating range.
  • Derate continuous power for ambient temperature and verify pulse or surge capability separately.
  • Match the land pattern, termination finish and current-sense routing to the exact package option.

Always confirm values against the latest manufacturer-controlled datasheet, especially when qualifying a substitute or releasing a production BOM.