4230-T110-K0DU-30A overview

4230-T110-K0DU-30A is a component documented by ETAL Group. The PDF description identifies it as "Protection of cables, motors, generators and transformers, thyristors and silicon rectifiers." This guide condenses the most useful engineering information from the available PDF so that designers and sourcing teams can identify the checks that still need confirmation in the original document.

Datasheet snapshot

  • Manufacturer: ETAL Group
  • Part number: 4230-T110-K0DU-30A
  • Category: IC
  • Datasheet length: 12 Pages

Specifications and operating details

The following points were extracted from the PDF text. Check the associated conditions, notes and limits in the complete document before using a value in a design.

  • Cable cross section ≤35 mm² Ambient temperature: -35°C...+ 70°C Mounting rail mounting Mass approx.
  • Ambient temperature 30 °C Note When mounted side-by-side, the breakers can only carry up to 80 % of their rated current or a higher rating has to be selected (see chap- ter Technical Information).
  • contact switch Style 0 change-over contact Terminals 1 screw terminals Key for nominal output A (to IEC/EN 60947-5-1) AC voltage DC voltage Rated Rated Rated Rated voltage current voltage current B (to UL 489) 110...220 V 1,5 A Delivery co.
  • Ambient temperature -35 °C ...+ 70 °C Width 9 mm Mass approx.
  • Ambient temperature -35 °C...+ 70 °C Width 18 mm Mass approx.
  • trip voltage AC 200 V AC 160 V AC 160 V AC 80 V Power consumption min.
  • response power 240 W 35 W 240 W 35 W 200 W 35 W 200 W 35 W Rated current of auxiliary contact Voltage ratings DC DC 125 V DC 48 V DC 24 V DC 12 V Min.

Topics covered by the datasheet

The document includes sections related to:

  • Description

Engineering review checklist

  • Confirm repetitive reverse voltage, average forward current, surge current and leakage at the intended temperature.
  • Check forward-voltage loss and reverse-recovery behavior at the actual current and switching frequency.
  • Review package thermal resistance, copper area, polarity marking and transient derating before layout release.

Always confirm values against the latest manufacturer-controlled datasheet, especially when qualifying a substitute or releasing a production BOM.

View the complete PDF and model record

Open the 4230-T110-K0DU-30A datasheet and model details to review the complete PDF, document pages and available product information.