The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Feb 8, 2021 Product data sheet Characteristics XCSTR762 safety switch XCSTR - spindle 80 mm - 2NC +1NO -M16 Main Range of product Preventa Safety detection Product or component type Guard switch Component name XCSTR Material Plastic Head type Turret head rotary axis Insulation Double insulated Type of operator Spindle 80 mm Electrical connection Terminal Contacts type and composition

1 NC + 1 NC + 1 NO

Contact operation Slow-break, break before make Clamping connection capacity Cable entry 2 entries tapped for M16 x 1.5 Number of poles 3 Complementary Cable outer diameter 7…10 mm Positive opening With NC contact Tripping angle 5 ° Mechanical durability 1000000 cycles Minimum torque for tripping 0.1 N.m Positive opening minimum torque 0.45 N.m Minimum actuation speed 0.1 m/s Contact code designation B300, AC-15 (Ue = 120 V, Ie = 6 A) conforming to EN/IEC 60947-5-1 B300, AC-15 (Ue = 240 V, Ie = 3 A) conforming to EN/IEC 60947-5-1 Q300, DC-13 (Ue = 125 V, Ie = 0.2 A) conforming to EN/IEC 60947-5-1 R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 [Ithe] conventional enclosed thermal current 6 A [Ui] rated insulation voltage 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14

400 V (pollution degree 3) conforming to EN/IEC 60947-1

[Uimp] rated impulse withstand voltage EN/IEC 60947-5-1 4 kV Maximum resistance across terminals 30 mOhm conforming to EN/IEC 60947-5-4 Short-circuit protection 6 A cartridge fuse type gG (gl) Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508 Safety reliability data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear Enclosure material Polyamide PA66 fibre glass impregnated Lever material Stainless steel Width 52 mm Height 117 mm Depth 110 mm Net weight 0.187 kg

Standards EN/IEC 60947-5-1 EN/ISO 12100 CSA C22.2 No 14 EN/IEC 60947-5-4 UL 508 EN/IEC 60204-1 EN 1088/ISO 14119 Product certifications UL CSA BG Protective treatment TC TH Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -40…70 °C Vibration resistance 50 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27 Electrical shock protection class Class II conforming to EN/IEC 61140 IP degree of protection IP67 conforming to IEC 60529 Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 262 g Package 1 Height 6.2 cm Package 1 width 11.6 cm Package 1 Length 17 cm Offer Sustainability Sustainable offer status Green Premium product REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information Contractual warranty Warranty 18 months