The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jan 29, 2021 Product data sheet Characteristics XCSTA591 plastic safety switch XCSTA - 1 NC + 2 NO - slow break - 1 entry tapped Pg 11 Main Range of product Preventa Safety detection Product or component type Safety switch Component name XCSTA Design Compact Material Plastic Head type Key operated turret head Contacts type and composition
1 NC + 2 NO
Contact operation Slow-break, break before make Cable entry 2 entries tapped for Pg 11 Cable outer diameter 7…10 mm with or without cable end Number of poles 3 Locking options
description
Without locking of actuator Complementary Insulation Double insulated Positive opening With NC contact Mechanical durability 1000000 cycles Positive opening minimum force 15 N Minimum actuation speed 0.01 m/s Maximum actuation speed 0.5 m/s [Ie] rated operational current 6 A at 120 V, AC-15, A300 conforming to EN/IEC 60947-5-1
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage 300 V conforming to UL 508
500 V conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14 [Uimp] rated impulse withstand voltage 6 kV EN/IEC 60947-5-1 Short-circuit protection 10 A cartridge fuse type gG (gl) Actuator forcible withdrawal rtc 10 N Maximum operating rate 10 cyc/mn for maximum durability Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Safety reliability data B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear Body material PA (polyamide) Head material PA (polyamide) Depth 30 mm Height 115 mm Width 52 mm Net weight 0.16 kg
CSA C22.2 No 14 Product certifications UL CSA Protective treatment TC Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -40…70 °C Vibration resistance 5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 10 gn for 11 ms conforming to IEC 60068-2-27 Electrical shock protection class Class II conforming to EN/IEC 61140 IP degree of protection IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 Packing Units Package 1 Weight 0.171 kg Package 1 Height 0.400 dm Package 1 width 1.230 dm Package 1 Length 0.850 dm Offer Sustainability Sustainable offer status Green Premium product REACh Regulation REACh Declaration EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information Contractual warranty Warranty 18 months