The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Feb 8, 2021 Product data sheet Characteristics XCSP3702G13 safety limit switch - plastic - roller plunger - 2NC+1NO - 1entry tapped Pg 13.5 Main Range of product Preventa Safety detection Product or component type Safety limit switch Component name XCSP Design Compact Material Plastic Head type Plunger head Protection technology Plastic protective cover, secured by 5-lobe socket head safety screw Type of operator Steel roller plunger Contacts type and composition
1 NC + 1 NC + 1 NO
Contact operation Slow-break, break before make Cable entry 1 entry tapped for Pg 13.5 Complementary Electrical connection Terminal Switch actuation By 30° cam Number of poles 3 Positive opening With NC contact Mechanical durability 10000000 cycles Minimum force for tripping 12 N Positive opening minimum force 36 N Maximum actuation speed 0.5 m/s Contact code designation B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A [Ithe] conventional enclosed thermal current 6 A [Ui] rated insulation voltage 300 V conforming to UL 508
400 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14 [Uimp] rated impulse withstand voltage EN/IEC 60947-1 4 kV IEC 60664 4 kV Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3 Short-circuit protection 6 A cartridge fuse type gG (gl) Repeat accuracy 0.1 mm on tripping points, 1 million operating cycles for head with end plunger Body material Plastic Head material Zamak Enclosure material Plastic Depth 35 mm Height 100 mm Width 34 mm Net weight 0.255 kg
Standards EN 1088/ISO 14119 EN/IEC 60947-5-1 CSA C22.2 No 14 EN/IEC 60204-1 UL 508 Product certifications UL CSA Safety level Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508 Safety reliability data B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear Protective treatment TC Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -40…70 °C Vibration resistance 25 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27 Electrical shock protection class Class II conforming to NF C 20-030 Class II conforming to EN/IEC 61140 IP degree of protection IP66 conforming to IEC 60529 IP67 conforming to IEC 60529 IK degree of protection IK04 conforming to EN 50102 Packing Units Package 1 Weight 0.122 kg Package 1 Height 1.050 dm Package 1 width 0.330 dm Package 1 Length 0.430 dm Offer Sustainability Sustainable offer status Green Premium product EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope) EU RoHS Declaration Mercury free Yes RoHS exemption information Yes Environmental Disclosure Product Environmental Profile Circularity Profile End of Life Information Contractual warranty Warranty 18 months