The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jan 18, 2021 Product data sheet Characteristics XCRA111EX limit switch XCR - square rod 6 mm - 2NC + 2NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Special format Product or component type Limit switch Product specific application For hoisting and mechanical handling applications Device short name XCR Body type Fixed Head type Rotary head Material Metal Fixing mode By the body Movement of operating head Rotary Type of operator Spring return rod lever metal square rod 6 mm Switch actuation By any moving part Type of approach Lateral approach, 2 directions Electrical connection Screw-clamp terminals, clamping capacity: 1 x Cable entry number 1 tapped entry for Pg 13.5 cable gland (included) 9…12 mm Number of poles 4 Contacts type and composition 2 x (1 NC + 1 NO) Contacts insulation form Zb Contact operation Snap action Number of steps 1 Contact block per direction [control circuit] 2 per direction Positive opening With Minimum force for tripping 0.75 N Minimum torque for tripping 0.45 N.m Maximum actuation speed 1.5 m/s IP degree of protection IP65 conforming to IEC 60529 Complementary Minimum actuation speed 0.01 m/min Maximum displacement angle -55 ° 55 ° Contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN 60947-5-1 A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN 60947-5-1 Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A [Ui] rated insulation voltage 300 V conforming to UL 508

500 V conforming to NF C 20-040 group C

500 V (pollution degree 3) conforming to IEC 60947-1

500 V (pollution degree 3) conforming to VDE 0110

Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3

25 MOhm conforming to NF C 93-050 method A

[Uimp] rated impulse withstand voltage IEC 60664 6 kV IEC 60947-1 6 kV

Short-circuit protection 10 A cartridge fuse, type gG Electrical durability 5000000 Cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C

5000000 Cycles, DC-13, inductive load type, 24 V, 10 W, operating rate

<3600 cyc/mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <3600 cyc/ mn, load factor: 0.5, DC conforming to IEC 60947-5-1 appendix C Mechanical durability 10000000 cycles Marking II2 D-Ex tb IIIC T85°C Db IP66/67 Width 85 mm Height 95 mm Depth 75 mm Environment Shock resistance 68 gn conforming to IEC 60068-2-27 Vibration resistance 9 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 Electrical shock protection class Class I conforming to IEC 60536 Class I conforming to NF C 20-030 Ambient air temperature for operation -20…60 °C Protective treatment TC Dust zone Zone 21 - 22 Product certifications INERIS 04ATEX0014X IEC-Ex INE 16.0048X Standards EN/IEC 60079-31 EN/IEC 60079-0 Directives 2014/34/EU - ATEX directive Packing Units Package 1 Weight 1.044 kg Package 1 Height 2.050 dm Package 1 width 1.020 dm Package 1 Length 0.810 dm Offer Sustainability REACh Regulation REACh Declaration EU RoHS Directive Not applicable, out of EU RoHS legal scope Environmental Disclosure Product Environmental Profile Contractual warranty Warranty 18 months

(1) 1 tapped entry for n° 13 cable gland. (2) Rod length: 200 mm.

Two 2-pole NC + NO Snap Action (A) 1st contact (B) 2nd contact

(P) Positive opening point (A) 1st contact (B) 2nd contact (1) NC contact with positive opening operation (2) Closed (3) Open (4) Tripping (5) Resetting