Ultra-high efficiency 1U size PLUG & PLAY POWER next generation power source
FEATURES
- 1.5V to 58V standard output voltages
- All outputs fully floating
- Extra low profile: 1U height (40mm)
- Ultra high efficiency, up to 90%
- Plug & Play Power - allows fast custom configuration - allow easy logistics
- Reduced system heat dissipation
- Few electrolytic capacitors (all long life)
- V isual LED indicators
- Series / Parallel of multiple outputs
- 5V bias standby voltage provided
- Individual output control signals APPLICATIONS INCLUDE
- Industrial machines
- T est and measurement
- Automation equipment
- Printing
- T elecommunications
- For Medical applications see Xvite EFFICIENCY (typical) MODEL Vmin Vnom Vmax Imax Watts Xg1 1.5 2.5 3.6 50A 125W Xg2 3.2 5.0 6.0 40A 200W Xg3 6.0 12.0 15.0 20A 240W Xg4 12.0 24.0 30.0 10A 240W Xg5 28.0 48.0 58.0 6A 288W Xg7 5.0 24.0 28.0 5A 120W Xg8 V1 5.0 24.0 28.0 3A 72W V2 5.0 24.0 28.0 3A 72W AC/DC Plug & Play Power Supply Series 400W-1200W MECHANICAL SPECIFICATIONS Standard The Xcite family of power supplies provides up to an incredible 1200W in an extremely compact 1U x 260 x 127mm package. Boasting industry leading power density of 15W/in3 and efficiencies of up to 90%, the Xcite family employs an innovative plug & play architecture that allows users to instantly configure a custom power solution in less than 5 minutes! Ultra high efficiencies and high power density are made possible through the combination of low loss technologies and the best field-proven technologies in planar magnetics and surface mount electronics. Significantly increased efficiency reduces system thermal load by more than 50%. The X cite family consists of 4 powerPac models ranging in power levels from 400W to 1200W. Each model may be populated with up to 6 powerMods selected from the table of powerMods shown below. All configurations carry full safety agency approvals, UL60950, EN60950 and are CE marked. For alternative power interfaces contact support@excelsys.com powerPacspowerMods Series MODEL Watts XCA 400W XCB 700W XCC 1000W XCD 1200W J1 J2 INPUT AC 100V-240V 50/60Hz SEE INSTRUCTION MANUAL 70C MAX OPERATING TEMPERATURE 29.50 40.40 122.0046.00 23.50 23.50 80.00 92.00 19.00 19.00 127.00 SLOT F SLOT E SLOT D SLOT C SLOT B SLOT A 19.00 Third angle projection TOP VIEW All dimensions in mm. Mounting Holes 4 M4 threaded holes on Base. Max screw penetration is 6mm from Base. Fleximount Side Mounting Slots Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401) 50.00 97.75 cite Line Voltage VAC 8570 100 115 130 145 160 175 190 205 220 235 260 Efficiency % patents pending
NOTES 1. This product is not intended for use as a st and alone unit and must be inst alled by qualified personnel. 2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice. 3. All specifications at nominal input, full load, 25°C unless otherwise stated. Doc. 40032 rev. 05 08/07 400W-1200W AC/DC Plug & Play Power Supply Series SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac INPUT Parameter Conditions/Description Min Nom Max Units Input Voltage Range Universal Input 85 264 VAC 120 380 VDC Input Frequency Range 47 63 Hz Power Rating XCA 400 W XCB 700 W XCC Derate linearly from 1000W at 100VAC to 850W at 85VAC 1000 W XCD Derate linearly from 1200W at 120VAC to 850W at 85VAC 1200 W Input Current XCA 85VAC in 400W out 7.5 A XCB 85VAC in 700W out 9.5 A XCC, XCD 85VAC in 850W out 11.5 A Inrush Current 230VAC @ 25°C 25 A Undervoltage Lockout Shutdown 65 74 VAC Fusing XCA 250V F8A HRC XCB 250V F10A HRC XCC, XCD 250V F12A HRC OUTPUT Parameter Conditions/Description Min Nom Max Units powerMod Power As per powerMod table Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table Electronic: See Xgen Designers’ Manual Minimum Load 0 A Line Regulation For ±10% change from nominal line ±0.1 % Load & Cross Regulation For 25% to 75% load change ±0.2 % Transient Response For 25% to 75% load change Voltage Deviation 10 % Settling Time 250 µs Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk Overvoltage Protection 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 % Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %. See Designer’s Manual for full details Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC Overshoot 2 % Turn-on Delay From AC In / Enable signal 300 / 30 ms Rise Time Monotonic 5 ms Hold-up Time For nominal output voltages at full load. XCA,XCB,XCC / XCD 20 / 15 ms Output Isolation Output to Output / Output to Chassis 500 / 500 VDC GENERAL Parameter Conditions/Description Min Nom Max Units Isolation Voltage Input to Output 3000 VAC Input to Chassis 1500 VAC Efficiency 230VAC, 1200W @ 24V 90 % Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875 Leakage Current 250VAC, 60Hz, 25°C 1.5 mA Signals See Xgen Series datasheet Bias Supply Always ON. Current 250mA 4.9 5.0 5.1 VDC Reliability Failures per million hours at 25°C and full load powerMod 1.0 fpmh See Designers’ Manual. powerPac excludes fans powerPac 0.6 fpmh EMC Parameter Standard Level Units Emissions Conducted EN55011, EN55022, FCC Level B Radiated EN55011, EN55022, FCC Level B Harmonic Distortion EN61000-3-2 Compliant Flicker and Fluctuation EN61000-3-3 Compliant Immunity Electrostatic Discharge EN61000-4-2 Level 4 Radiated RFI EN61000-4-3 Level 3 Fast Transients - burst EN61000-4-4 Level 4 Input Line Surges EN61000-4-5 Class 4 Conducted RFI EN61000-4-6 10 V/m Voltage Dips EN61000-4-11 (EN55024) 10 ms ENVIRONMENTAL Parameter Conditions/Description Min Nom Max Units Operating Temperature -20 +70 °C Storage Temperature -40 +85 °C Derating 1.6% per °C above 40°C. See Designers Manual for full deratings Relative Humidity Non-condensing 5 95 %RH Shock 3000 Bumps, 10G (16ms) half sine Vibration 1.5G 10 200 Hz Standard North America Excelsys Technologies t: (972) 771 4544
519 Interstate 30, #309 f: (972) 421 1805
Rockwall, TX 75087 e: salesusa@excelsys.com USA Europe/Asia Excelsys Technologies Ltd t: +353 21 4354716
27 Eastgate Drive f: +353 21 4354864
Eastgate Business Park e: sales@excelsys.com Little Island, Cork, Ireland IRELAND