X93255_08 INTERSIL | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 7
Technical content
Features
- Dual solid-state potentiometers
- Independent Up/Down interfaces
- 32 wiper tap points per potentiometer - Wiper position stored in nonvolatile memory and recalled on power-up
- 31 resistive elements per potentiometer - Temperature compensated - Maximum resistance tolerance ± 25% - Terminal voltage, 0 to V CC
- Low power CMOS -V CC = 5V ± 10% - Active current, 200µA typ. - Standby current, 4µA max
- High reliability - Endurance 200,000 data changes per bit - Register data retention, 100 years TOTAL value = 50kΩ
- Package - 14 Ld TSSOP VCC CS1 INC2 U/D2 RH2 VSS RL1 DNC* *Do not connect. CS2 INC1 U/D1 RH1 RL2 DNC*
Ordering Information
PART NUMBER PART MARKING V CC LIMITS (V) R TOTAL (kΩ) TEMP RANGE (°C) PACKAGE PKG DWG. # X93255UV14I X9325 5UVI 5 ±10% 50 -40 to +85 14 Ld TSSOP M14.173 X93255UV14IT1* X9325 5UVI 5 ±10% 50 -40 to +85 14 Ld TSSOP M14.173 * Please refer to TB347 for details on reel specifications. Data Sheet February 4, 2008
2 FN8187.1 February 4, 2008 Block Diagram CONTROL AND MEMORY UP/DOWN (U/D1) INCREMENT (INC1) DEVICE SELECT (CS1) VCC (SUPPLY VOLTAGE) VSS (GROUND) RH1 RL1 30kΩ RH2 RL2 CONTROL AND MEMORY UP/DOWN (U/D2) INCREMENT (INC2) DEVICE SELECT (CS2) 30kΩ Pin Descriptions TSSOP SYMBOL DESCRIPTION
1 DNC Do Not Connect
8 DNC Do Not Connect
10 CS 2 Chip Select 2
11 V CC Supply Voltage
12 INC 1 Increment 1
13 U/D 1 Up/Down 1
14 R H1 High Terminal 1
3 FN8187.1 February 4, 2008 Absolute Maximum Ratings Thermal Information Voltage on CS, INC, U/D, RH, RL and VCC Recommended Operating Conditions Temperature Range Supply Voltage result in failures not covered by warranty. NOTES: 1. Absolute linearity is utilized to determine ac tual wiper resistance vs expected resistance = (RH(n)(actual) - RH(n)(expected)) = ±1 Ml Maximum. n = 1 .. 29 only 3. 1 Ml = Minimum Increment = R TOT/31. 4. Typical values are for TA = +25°C and nominal supply voltage. 5. Limits established by characteri zation and are not production tested. 6. When performing multiple write operations, V CC must not decrease by more than 150mV from its initial value. 7. Parts are 100% tested at +25°C. Over-temperature limi ts established by characterization and are not production tested. Potentiometer Characteristics Over recommended operating conditions, unless otherwise specified. SYMBOL PARAMETER TEST CONDITIONS/NOTES MIN (Note 7) TYP (Note 4) MAX (Note 7) UNIT RTOT End-to-End Resistance 37.5 50 62.5 k Ω VR RH, RL Terminal Voltages 0 V CC V Power Rating R TOTAL = 50kΩ (Note 5) 1 m Ω (Note 6) Noise Ref: 1kHz (Note 5) -120 dBV (Note 6) RW Wiper Resistance (Note 5) 1000 Ω IW Wiper Current (Note 5) 0.6 mA Resolution 3% Absolute Linearity (Note 1) R H(n)(actual) - RH(n)(expected) ±1 MI (Note 3) Relative Linearity (Note 2) R H(n+1 - [RH(n)+MI] ±0.5 MI (Note 3) RTOTAL Temperature Coefficient (Notes 5) ±35 ppm/°C CH/CL/CW Potentiometer Capacitances See “Circuit #2 SPICE Macro Model” on page 4 10/10/25 pF X93255
4 FN8187.1 February 4, 2008 Test Circuit #1 Circuit #2 SPICE Macro Model DC Operating Specifications Over recommended operating conditions unless otherwise specified. SYMBOL PARAMETER TEST CONDITIONS MIN (Note 7) TYP (Note 4) MAX (Note 7) UNIT ICC1 VCC Active Current (Increment) per DCP CS = VIL, U/D = VIL or VIH and INC = 0.4V @ max. tCYC 200 300 µA ICC2 VCC Active Current (Store) (EEPROM Store) per DCP CS = VIH, U/D = VIL or VIH and INC = VIH @ max. tWR 1400 µA ISB Standby Supply Current CS = VCC - 0.3V, U/D and INC =V SS or VCC - 0.3V 4µ A ILI CS V CS = VCC ±1 µA ILI CS V CC = 5V, CS = 0 120 200 250 µA ILI INC, U/D Input Leakage Current V IN = VSS to VCC ±1 µA VIH CS, INC, U/D Input HIGH Voltage V CC x 0.7 V CC + 0.5 V VIL CS, INC, U/D Input LOW Voltage -0.5 V CC x 0.1 V CIN (Note 6) CS, INC, U/D Input Capacitance V CC = 5V, VIN = VSS, TA = +25°C, f = 1MHz (Note 5) 10 pF Endurance and Data Retention PARAMETER MIN UNIT Minimum endurance 200,000 Data changes per bit Data retention 100 Years TEST POINT VH/RH AC Conditions of Test Input pulse levels 0V to 5V Input rise and fall times 10ns Input reference levels 1.5V CH CL 10pF 10pF RH RTOTAL CW 25pF RL AC Operating Characteristics Over recommended operating conditions unless otherwise specified. In the table, CS, INC, U/D, RH and RL are used to refer to either CS1 or CS2, etc. SYMBOL PARAMETER MIN (Note 7) TYP (Note 4) MAX (Note 7) UNIT tCl CS to INC Setup 100 ns tlD INC HIGH to U/D Change 100 ns tDI U/D to INC Setup 100 ns tlL INC LOW Period 1 µs tlH INC HIGH Period 1 µs tlC INC Inactive to CS Inactive 1 µs tCPH CS Deselect Time (No store) 250 ns tCPH CS Deselect Time (Store) 10 ms tCYC INC Cycle Time 2 µs tR, tF (Note 5) INC Input Rise and Fall Time 500 µs tR VCC (Note 5) VCC Power-up Rate 1 50 V/ms tWR Store cycle 51 0 m s X93255
5 FN8187.1 February 4, 2008 AC Timing Power-up and Power-down Requirements There are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potentiometer pins provided that VCC is always more positive than or equal to VH and VL, i.e., VCC ≥ VH,VL. The VCC ramp rate specification is always in effect. Pin Descriptions RH and RL The RH and RL pins of the X93255 are equivalent to the end terminals of a variable resistor. The minimum voltage is VSS and the maximum is VCC. The terminology of RH and RL references the relative position of the terminal in relation to wiper movement direction selected by the U/D input per potentiometer. Up/Down (U/D) The U/D input controls the direction of a single potentiometer’s wiper movement and whether the counter is incremented or decremented. Increment (INC) The INC input is negative-edge triggered. Toggling INC will move the wiper and either increment or decrement the pertaining potentiometer’s counter in the direction indicated by the logic level on the pertaining potentiometer’s U/D input. Chip Select (CS) A potentiometer is selected when the pertaining CS input is LOW. Its current counter value is stored in nonvolatile memory when the pertaining CS is returned HIGH while the pertaining INC input is also HIGH. After the store operation is complete, the affected potentiometer will be placed in the low power standby mode until the potentiometer is selected once again. Principles of Operation There are multiple sections for each potentiometer in the X93255: an input control, a counter and decode section; the nonvolatile memory; and a resistor array. Each input control section operates just like an up/down counter. The output of this counter is decoded to turn on a single electronic switch connecting a point on the resistor array to the wiper output. Under the proper conditions, the contents of the counter can be stored in nonvolatile memory and retained for future use. Each resistor array is comprised of 31 individual resistors connected in series. At either end of the array and between each resistor is an electronic switch that transfers the connection at that point to the wiper. The wiper is connected to the R L terminal, forming a variable resistor from RH to RL. Each wiper, when at either fixed terminal, acts like its mechanical equivalent and does not move beyond the last position. That is, the counter does not wrap around when clocked to either extreme. If the wiper is moved several positions, multiple taps are connected to the wiper for up to 10µs. The 2-terminal resistance value for the device can temporarily change by a significant amount if the wiper is moved several positions. When the device is powered-down, the last wiper position stored will be maintained in the nonvolatile memory for each potentiometer. When power is restored, the contents of the memory are recalled and each wiper is set to the value last stored. CS INC U/D tCI tIL tIH tCYC tID tDI tIC tCPH tF tR 10% 90% 90% (STORE) Note: CS, INC, U/D, RH and RL are used to refer to either CS1 or CS2, etc. X93255
6 FN8187.1 February 4, 2008 Instructions and Programming The INC, U/D and CS inputs control the movement of the pertaining wiper along the resistor array. With CS set LOW, the pertaining potentiometer is selected and enabled to respond to the U/D and INC inputs. HIGH to LOW transitions on INC will increment or decrement (depending on the state of the U/D input) a 5-bit counter. The output of this counter is decoded to select one of thirty two wiper positions along the resistive array. The value of the counter is stored in nonvolatile memory whenever each CS transitions HIGH while the pertaining INC input is also HIGH. In order to avoid an accidental store during power-up, each CS must go HIGH with VCC during initial power-up. When left open, each CS pin is internally pulled up to VCC by an internal 30k resistor. The system may select the X93255, move any wiper and deselect the device without having to store the latest wiper position in nonvolatile memory. After the wiper movement is performed as previously described and once the new position is reached, the system must keep INC LOW while taking CS HIGH. The new wiper position will be maintained until changed by the system or until a power-up/down cycle recalled the previously stored data. In order to recall the stored position of the wiper on power-up, the CS pin must be held HIGH. This procedure allows the system to always power-up to a preset value stored in nonvolatile memory; then during system operation minor adjustments could be made. The adjustments might be based on user preference, system parameter changes due to temperature drift, or other system trim requirements. The state of U/D may be changed while CS remains LOW. This allows the host system to enable the device and then move each wiper up and down until the proper trim is attained. Symbol Table Mode Selection CS INC U/D MODE L H Wiper Up L L Wiper Down H X Store Wiper Position H X X Standby Current L X No Store, Return to Standby L H Wiper Up (not recommended) L L Wiper Down (not recommended) WAVEFORM INPUTS OUTPUTS Must be steady Will be steady May change from Lo w to High Will change from Lo w to High May change from High to Low Will change from High to Low Don’t Care: Changes Allowed Changing: State Not Known N/A Center Line is High Impedance X93255
All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, soft ware and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnishe d by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see www.intersil.com FN8187.1 February 4, 2008 X93255 Thin Shrink Small Outline Plastic Packages (TSSOP) α INDEX AREA D N 123 -B- 0.10(0.004) C AM BS e -A- b M -C- A SEATING PLANE 0.10(0.004) c E 0.25(0.010) BM M L 0.25 0.010 GAUGE PLANE NOTES: 1. These package dimensions are within allowable dimensions of JEDEC MO-153-AC, Issue E. 2. Dimensioning and tolerancing per ANSI Y14.5M -1982. 3. Dimension “D” does not include mold flash, protrusions or gate burrs. Mold flash, protrusion and gate burrs shall not exceed 0.15mm (0.006 inch) per side. 4. Dimension “E1” does not include interlead flash or protrusions. Inter- lead flash and protrusions shall not exceed 0.15mm (0.006 inch) per side. 5. The chamfer on the body is optional. If it is not present, a visual index feature must be located within the crosshatched area. 6. “L” is the length of terminal for soldering to a substrate. 7. “N” is the number of terminal positions. 8. Terminal numbers are shown for reference only. 9. Dimension “b” does not include dambar protrusion. Allowable dambar protrusion shall be 0.08mm (0.003 inch) total in excess of “b” dimen- sion at maximum material condition. Minimum space between protru- sion and adjacent lead is 0.07mm (0.0027 inch). 10. Controlling dimension: MILLIMETE R. Converted inch dimensions are not necessarily exact. (Angles in degrees) 0.05(0.002) M14.173
14 LEAD THIN SHRINK SMALL OUTLINE PLASTIC
A - 0.047 - 1.20 - A1 0.002 0.006 0.05 0.15 - A2 0.031 0.041 0.80 1.05 - b 0.0075 0.0118 0.19 0.30 9 c 0.0035 0.0079 0.09 0.20 - D 0.195 0.199 4.95 5.05 3 E1 0.169 0.177 4.30 4.50 4 e 0.026 BSC 0.65 BSC - E 0.246 0.256 6.25 6.50 - L 0.0177 0.0295 0.45 0.75 6 N1 4 1 4 7 α 0o 8o 0o 8o - Rev. 2 4/06