X4643 XICOR | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 22
Technical content
REV 1.26 4/30/02 Characteristics subject to change without notice. 1 of 22 www.xicor.com Preliminary Information 64K X4643/5 8K x 8 Bit CPU Supervisor with 64K EEPROM
FEATURES
- Selectable watchdog timer
- L o w V CC detection and reset assertion —Four standard reset threshold voltages —Adjust low V CC reset threshold voltage using special programming sequence —Reset signal valid to V CC = 1V
- Low power CMOS —<20µA max standby current, watchdog on —<1µA standby current, watchdog off —3mA active current
- 64Kbits of EEPROM —64-byte page write mode —Self-timed write cycle —5ms write cycle time (typical)
- Built-in inadvertent write protection —Power-up/power-down protection circuitry
- 400kHz 2-wire interface
- 2.7V to 5.5V power supply operation
- Available packages —8-lead SOIC —8-lead TSSOP
DESCRIPTION
The X4643/5 combines four popular functions, Power-on Reset Control, Watchdog Timer, Supply Voltage Supervision, and Serial EEPROM Memory in one package. This combination lowers system cost, reduces board space requirements, and increases reli- ability. Applying power to the device activates the power on reset circuit which holds RESET /RESET active for a period of time. This allows the power supply and oscilla- tor to stabilize before the processor can execute code. The Watchdog Timer provides an independent protection mechanism for microcontrollers. When the microcon- troller fails to restart a timer within a selectable time out interval, the device activates the RESET /RESET signal. The user selects the interval from three preset values. Once selected, the interval does not change, even after cycling the power. The device’s low V CC detection circuitry protects the user’s system from low voltage conditions, resetting the system when V CC falls below the set minimum V CC trip point. RESET/RESET is asserted until V CC returns to proper operating level and stabilizes. Four industry BLOCK DIAGRAM Watchdog Timer Reset Data Register Command Decode & Control Logic SDA SCL VCC Reset & Watchdog Timebase Power on and GenerationVTRIP RESET (X4643/5) Reset Low Voltage Status Register Protect Logic EEPROM Array Watchdog Transition Detector WP VCC Threshold Reset Logic Block Lock Control RESET (X4645) 8Kbit
X4643/5 – Preliminary Information Characteristics subject to change without notice. 2 of 22REV 1.26 4/30/02 www.xicor.com standard V TRIP thresholds are available, however, Xicor’s unique circuits allow the threshold to be reprogrammed to meet custom requirements or to fine- tune the threshold for applications requiring higher precision. PIN CONFIGURATION VSS VCC SDA SCL3 8S0 WP RESET/RESET VCC SCL RESET/RESET VSS3 8WP SDA 8-Pin JEDEC SOIC
8 Pin TSSOP
(SOIC) Pin (TSSOP) Name Function 13 S Device Select Input 24 S Device Select Input
35 RESET/
RESET/RESET is an active LOW/HIGH, open drain output which goes active whenever V CC falls below the minimum V CC sense level. It will remain active until V CC rises above the minimum V CC sense level for 250ms. RESET/ RESET goes active if the Watchdog Timer is enabled and SDA remains either HIGH or LOW longer than the selectable Watchdog time out period. A falling edge on SDA, while SCL is HIGH, resets the Watchdog Timer. RESET /RESET goes active on power up and remains active for 250ms after the power supply stabilizes. 46V SS Ground 5 7 SDA Serial Data. SDA is a bidirectional pin used to transfer data into and out of the de- vice. It has an open drain output and may be wire ORed with other open drain or open collector outputs. This pin requires a pull up resistor and the input buffer is always active (not gated). Watchdog Input. A HIGH to LOW transition on the SDA (while SCL is HIGH) restarts the Watchdog timer. The absence of a HIGH to LOW transition within the watchdog time out period results in RESET/RESET going active. 6 8 SCL Serial Clock. The Serial Clock controls the serial bus timing for data input and output. 71W P Write Protect. WP HIGH used in conjunction with WPEN bit prevents writes to the control register. 82V CC Supply Voltage
Characteristics subject to change without notice. active. This signal provides several benefits. to operate with insufficient voltage. bilization of the oscillator. tion prior to initialization of the circuit. reducing the likelihood of data corruption on power up. RESET allowing the system to begin operation. signal remains active until the voltage drops below 1V. allowed and no nonvolatile write operation can start. goes active are allowed to finish. memory Block Lock and the Write Protect (WP) pin. These are discussed elsewhere in this document. Figure 1. Set V
Characteristics subject to change without notice. Figure 4. V nonvolatile and do not change when power is removed. data byte is allowed for each register write operation. the Control Register" below. bytes written after the first byte is entered. time by performing a random read at address FFFFh. Only one byte is read by each register read operation.
The X4643/5 resets itself after the first byte is read. tile latch that powers up in the LOW (disabled) state. the control register) or until the part powers up again. immediately after the stop condition. Watchdog Timer. The options are shown below. Table 1. Write Protect Enable Bit and WP Pin Function
Figure 10. Writing 12 bytes to a 64-byte page starting at location 60.
4 Bytes
8 Bytes
tents of the array will not be effected. can then proceed with the read or write operation. Refer to the flow chart in Figure 11. Figure 11. Acknowledge Polling Sequence
Figure 15. X4643/5 Addressing – The device is in the low power standby state. – SDA pin is the input mode. /RESET Signal is active for tPURST. – The WEL bit must be set to allow write operations. HIGH will prevent all writes to the Control Register. array from write operations.
X4643/5 – Preliminary Information Characteristics subject to change without notice. 14 of 22REV 1.26 4/30/02 www.xicor.com ABSOLUTE MAXIMUM RATINGS COMMENT Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only; functional operation of the device (at these or any other conditions above those listed in the operational sections of this specification) is not implied. Exposure to absolute maximum rating con- ditions for extended periods may affect device reliability. RECOMMENDED OPERATING CONDITIONS Temperature Min. Max. Commercial 0°C 70°C Industrial -40°C +85°C Option Supply Voltage Limits –2.7 and –2.7A 2.7V to 5.5V Blank and –4.5A 4.5V to 5.5V D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.) Notes: (1) The device enters the Active state after any start, and remains active until: 9 clock cycles later if the Device Select Bits in the Slave Address Byte are incorrect; 200ns after a stop ending a read operation; or tWC after a stop ending a write operation. (2) The device goes into Standby: 200ns after any stop, except those that initiate a nonvolatile write cycle; tWC after a stop that initiates a nonvolatile cycle; or 9 clock cycles after any start that is not followed by the correct Device Select Bits in the Slave Address Byte. (3) V IL Min. and VIH Max. are for reference only and are not tested. Symbol Parameter VCC = 2.7 to 5.5V Unit Test ConditionsMin Max ICC1 (1) Active Supply Current Read 1.0 mA V IL = VCC x 0.1, VIH = VCC x 0.9 fSCL = 400kHz, SDA = CommandsICC2 (1) Active Supply Current Write 3.0 mA ISB1 (2) Standby Current DC (WDT off) 1 µA V SDA = VSCL = VSB Others = GND or VSB ISB2 (2) Standby Current DC (WDT on) 20 µA V SDA = VSCL = VSB Others = GND or VSB ILI Input Leakage Current 10 µA V IN = GND to VCC ILO Output Leakage Current 10 µA V SDA = GND to VCC Device is in Standby(1) VIL (3) Input LOW Voltage -0.5 V CC x 0.3 V VIH (3) Input nonvolatile V CC x 0.7 V CC + 0.5 V VHYS Schmitt Trigger Input Hysteresis Fixed input level VCC related level 0.2 .05 x VCC V V V OL Output LOW Voltage 0.4 V I OL = 3.0mA (2.7–5.5V)
X4643/5 – Preliminary Information Characteristics subject to change without notice. 15 of 22REV 1.26 4/30/02 www.xicor.com CAPACITANCE (TA = 25°C, f = 1.0 MHz, VCC = 5V) Notes: (4) This parameter is periodically sampled and not 100% tested. Symbol Parameter Max. Unit Test Conditions COUT (4) Output Capacitance (SDA, RST/RST) 8 pF V OUT = 0V CIN (4) Input Capacitance (SCL, WP) 6 pF V IN = 0V EQUIVALENT A.C. LOAD CIRCUIT A.C. TEST CONDITIONS SDA or RESET 1533Ω 100pF For VOL= 0.4V and IOL = 3 mA Input pulse levels 0.1V CC to 0.9VCC Input rise and fall times 10ns Input and output timing levels 0.5V CC Output load Standard output load A.C. CHARACTERISTICS (Over recommended operating conditions, unless otherwise specified) Notes: (1) Typical values are for TA = 25°C and VCC = 5.0V (2) Cb = total capacitance of one bus line in pF . Symbol Parameter Min. Max. Unit fSCL SCL Clock Frequency 0 400 kHz tIN Pulse width Suppression Time at inputs 50 ns tAA SCL LOW to SDA Data Out Valid 0.1 0.9 µs tBUF Time the bus free before start of new transmission 1.3 µs tLOW Clock LOW Time 1.3 µs tHIGH Clock HIGH Time 0.6 µs tSU:STA Start Condition Setup Time 0.6 µs tHD:STA Start Condition Hold Time 0.6 µs tSU:DAT Data In Setup Time 100 ns tHD:DAT Data In Hold Time 0 µs tSU:STO Stop Condition Setup Time 0.6 µs tDH Data Output Hold Time 50 ns tR SDA and SCL Rise Time 20 + .1Cb 300 ns tF SDA and SCL Fall Time 20 + .1Cb 300 ns tSU:WP WP Setup Time 0.6 µs tHD:WP WP Hold Time 0 µs Cb Capacitive load for each bus line 400 pF
X4643/5 – Preliminary Information Characteristics subject to change without notice. 16 of 22REV 1.26 4/30/02 www.xicor.com TIMING DIAGRAMS Bus Timing WP Pin Timing Write Cycle Timing Nonvolatile Write Cycle Timing Notes: (1) t WC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used. Symbol Parameter Min. Typ. (1) Max. Unit tWC (1) Write Cycle Time 5 10 ms tSU:STO tDH tHIGH tSU:STA tHD:STA tHD:DAT tSU:DATSCL SDA IN SDA OUT tF tLOW tBUFtAA tR tHD:WP SCL SDA IN WP tSU:WP Clk 1 Clk 9 Slave Address Byte START SCL SDA tWC 8th bit of Last Byte ACK Stop Condition Start Condition
X4643/5 – Preliminary Information Characteristics subject to change without notice. 17 of 22REV 1.26 4/30/02 www.xicor.com Power-Up and Power-Down Timing RESET Output Timing Notes: (8) This parameter is periodically sampled and not 100% tested. SDA vs. RESET Timing Symbol Parameter Min. Typ. Max. Unit VTRIP Reset Trip Point Voltage, X4643/5-4.5A Reset Trip Point Voltage, X4643/5 Reset Trip Point Voltage, X4643/5-2.7A Reset Trip Point Voltage, X4643/5-2.7 4.5 4.25 2.85 2.55 4.62 4.38 2.92 2.62 4.75 4.5 3.0 2.7 V t PURST Power-up Reset Time Out 100 250 400 ms tRPD (8) VCC Detect to Reset/Output 500 ns tF (8) VCC Fall Time 100 µs tR (8) VCC Rise Time 100 µs VRVALID Reset Valid VCC 1V VCC tPURST tR tF tRPD
0 Volts
(X4645) (X4643) tPURST VRVALID tRSP<tWDO tRST RESET SDA tRSP Note: All inputs are ignored during the active reset period (tRST). tRST SCL tRSP>tWDO tRSP>tWDO
X4643/5 – Preliminary Information Characteristics subject to change without notice. 18 of 22REV 1.26 4/30/02 www.xicor.com RESET Output Timing VTRIP Programming Timing Diagram (WEL = 1) VTRIP Programming Parameters Symbol Parameter Min. Typ. Max. Unit tWDO Watchdog Time Out Period, WD1 = 1, WD0 = 1 (factory setting) WD1 = 1, WD0 = 0 WD1 = 0, WD0 = 1 WD1 = 0, WD0 = 0 100 450 OFF 250 650 1.5 300 850 ms ms sec t RST Reset Time Out 100 250 400 ms Parameter Description Min. Max. Unit tVPS VTRIP Program Enable Voltage Setup time 1 µs tVPH VTRIP Program Enable Voltage Hold time 1 µs tTSU VTRIP Setup time 1 µs tTHD VTRIP Hold (stable) time 10 ms tWC VTRIP Write Cycle Time 10 ms tVPO VTRIP Program Enable Voltage Off time (Between successive adjustments) 0 µs tRP VTRIP Program Recovery Period (Between successive adjustments) 10 ms VP Programming Voltage 15 18 V VTRAN VTRIP Programmed Voltage Range 2.55 4.75 V Vta1 Initial VTRIP Program Voltage accuracy (VCC applied–VTRIP) (Programmed at 25°C.) -0.1 +0.4 V Vta2 Subsequent VTRIP Program Voltage accuracy [(VCC applied–Vta1)—V TRIP. Programmed at 25°C.) -25 +25 mV Vtr VTRIP Program Voltage repeatability (Successive program operations. Programmed at 25°C.) -25 +25 mV Vtv VTRIP Program variation after programming (0–75°C). (Programmed at 25°C.) -25 +25 mV VTRIP programming parameters are periodically sampled and are not 100% tested. VCC (VTRIP) WP tTSU tTHD tVPHtVPS VP VTRIP tVPO SCL SDA A0h 01h or 03h tRP 00h 00h
X4643/5 – Preliminary Information Characteristics subject to change without notice. 19 of 22REV 1.26 4/30/02 www.xicor.com PACKAGING INFORMATION 0.150 (3.80) 0.158 (4.00) 0.228 (5.80) 0.019 (0.49) Pin 1 Pin 1 Index 0.010 (0.25) 0.020 (0.50) 0.050 (1.27) 0.188 (4.78) 0.197 (5.00) 0.004 (0.19) 0.010 (0.25) 0.053 (1.35) 0.069 (1.75) (4X) 7° 0.016 (0.410) 0.037 (0.937) 0.0075 (0.19) 0.010 (0.25) 0° - 8° X 45° 8-Lead Plastic Small Outline Gull Wing Package Type S NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 0.250" 0.050"Typical 0.050" Typical 0.030" Typical
8 PlacesFOOTPRINT
X4643/5 – Preliminary Information Characteristics subject to change without notice. 20 of 22REV 1.26 4/30/02 www.xicor.com PACKAGING INFORMATION NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 8-Lead Plastic, TSSOP, Package Type V See Detail “A” .031 (.80) .041 (1.05) .169 (4.3) .025 (.65) BSC .114 (2.9) .122 (3.1) .002 (.05) .006 (.15) .047 (1.20) .0075 (.19) .0118 (.30) 0° – 8° .010 (.25) .019 (.50) .029 (.75) Gage Plane Seating Plane Detail A (20X) (4.16) (7.72) (1.78) (0.42) (0.65) All Measurements Are Typical
X4643/5 – Preliminary Information Characteristics subject to change without notice. 21 of 22REV 1.26 4/30/02 www.xicor.com
Ordering Information
(Active LOW) Part Number RESET (Active HIGH) -40°C–85°C X4643S8I–4.5A X4645S8I–4.5A 8L TSSOP 0°C–70°C X4643V8–4.5A X4645V8–4.5A -40°C–85°C X4643V8I–4.5A X4645V8I–4.5A 4.5-5.5V 4.25-4.5 8L SOIC 0°C–70°C X4643S8 X4645S8 -40°C–85°C X4643S8I X4645S8I 8L TSSOP 0°C–70°C X4643V8 X4645V8 -40°C–85°C X4643V8I X4645V8I -40°C–85°C X4643S8I–2.7A X4645S8I–2.7A 8LTSSOP 0°C–70°C X4643V8–2.7A X4645V8–2.7A -40°C–85°C X4643V8I–2.7A X4645V8I–2.7A -40°C–85°C X4643S8I–2.7 X4645S8I–2.7 8L TSSOP 0°C–70°C X4643V8–2.7 X4645V8–2.7 -40°C–85°C X4643V8I–2.7 X4645V8I–2.7 8-Lead TSSOP EYWW XXXXX 8-Lead SOIC/PDIP X4643/5 X XX Blank = 8-Lead SOIC ADB/ADK = –4.5A (0 to +70°C) ADD/ADM = No Suffix (0 to +70°C) ADF/ADO = –2.7A (0 to +70°C) ADH/ADQ= –2.7 (0 to +70°C) Blank = No Suffix (0 to +70°C) I = No Suffix (-40 to +85°C) AN = –2.7A (0 to +70°C) AL = –4.5A (0 to +70°C)
X4643/5 – Preliminary Information Characteristics subject to change without notice. 22 of 22 LIMITED WARRANTY Devices sold by Xicor, Inc. are covered by the warranty and patent indemnification provisions appearing in its Terms of Sale onl y. Xicor, Inc. makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the descr ibed devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice. Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, or licenses are implied. TRADEMARK DISCLAIMER: Xicor and the Xicor logo are registered trademarks of Xicor, Inc. AutoStore, Direct Write, Block Lock, SerialFlash, MPS, and XDCP are also trademarks of Xicor, Inc. All others belong to their respective owners. U.S. PATENTS Xicor products are covered by one or more of the following U.S. Patents: 4,326,134; 4,393,481; 4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 5,161,137; 5,219,774; 5,270,927; 5,324,676; 5,434,396; 5,544,103; 5,587,573; 5,835,409; 5,977,585. Foreign patents and additional patents pending. LIFE RELATED POLICY In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection and correction, redundancy and back-up features to prevent such an occurrence. Xicor’s products are not authorized for use in critical components in life support devices or systems. 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. ©Xicor, Inc. 2000 Patents Pending REV 1.26 4/30/02 www.xicor.com