YOU MUST READ THIS BEFORE INSTALLATION ELECTRICAL SAFETY INSTALLATION REQUIREMENTS USER RESTRICTIONS USAGE ENVIRONMENT HOT SURFACE WARNING WARNING: RISK OF ELECTRIC SHOCK Always consult the Installation & Maintenance Instructions before connecting this product to the power supply. WARNING: Disconnect Power Before Servicing Ensure the electrical supply is safely disconnected before connecting to any supply, load, or control terminals. WARNING: Installation by Qualified Personnel Only This product must only be installed or fitted by a competent, qualified installer familiar with the relevant electrical standards and installation practices. WARNING: Not for Use by Vulnerable Individuals This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or instructed by a person responsible for their safety. WARNING: Industrial Use Only This is an industrial-grade product and is not intended for household use. WARNING: Hot Surfaces On certain models, surfaces marked with this symbol become hot during use. Avoid direct contact and follow all thermal safety precautions. More Info: https://united-automation.com/general-product-safety-regulation-gpsr/
17 November 2025 | Issue: 9 Page 1 of 5
Infrared Heating | Heater Controller Infresco-T 6kW Controller X20021 6000W, 240v Advanced Energy-Saving Solution for Heating and Lighting 0044 (0) 1704-516 501 enquiries@united-automation.com www.united-automation.com CONTACT US: KEY FEATURES: The Infresco-T 6kW Controller is a sophisticated part of the Infresco family, meticulously engineered to enhance energy efficiency when used with quartz infrared halogen lamps or other heating and lighting products. The 'T' model is designed to switch the lamps on for a predetermined time period ranging from 1 to 60 minutes, optimising energy use while providing ample warmth and illumination. The Infresco-T 6kW Controller is a reliable, cost-effective solution designed to maximise energy savings while extending the life of your lamps. Its microcontroller-based design ensures optimal performance, making it an ideal choice for a wide range of heating and lighting applications. Energy Saving: Provides heat for a predetermined time period, reducing unnecessary energy consumption. Extended Lamp Life: Incorporates a soft-start function and zero-voltage switching to mitigate initial high inrush current, potentially increasing lamp life by up to 30%. Control Capacity: Capable of controlling up to 4 x 1500W lamps, making it versatile for various settings. Cost-Effective: Offers a low- cost solution for effective heating and lighting control. Easy Installation. Soft-Start/Zero-Voltage Switch-Off: Enhances the longevity of the lamps and ensures safe operation. TECHNICAL SPECIFICATIONS Supply Voltage 230V AC ±10% @ 50/60Hz Max Load at 20°C Ambient 6kW Max. Lamp On-Time 1 to 60 minutes Current Consumption (control circuit) 20mA Terminals 6.0mm2 Rising Clamp Operating Temperature -20 to 40°C Protection Rating IP65 Gland Diameter Max. Cable Entry 2.5mm2 Enclosure Dimensions (W x L x H) 130x130x75 (mm) APPLICATIONS: Outdoor Areas: Ideal for providing targeted heating in outdoor spaces. Smoking Shelters: Ensures a comfortable environment in designated smoking areas. Restaurants: Enhances customer comfort in outdoor dining areas. Warehouses: Suitable for maintaining warmth in large, open industrial spaces. Workshops: Provides reliable heating for work environments.
X20021 Infrared Heating | Heater Controller Infresco-T 6kW Controller 6000W, 240v Advanced Energy-Saving Solution for Heating and Lighting BMF House - Wight Moss Way, Southport Business Park Southport PR8 4HQ ENGLAND, UNITED KINGDOM Contact Us: 0044 (0) 1704-516 501 enquiries@united-automation.com www.united-automation.com unitedautomationltd UA_Limited 17 November 2025 | Issue: 9 Page 2 of 5 INSTALLATION SAFETY FIRST! Please carefully read these instructions before installing and operating the Infresco unit. Positioning and Mounting 1. Positioning: Ensure the Infresco unit is positioned with the three fixed cable glands facing downward to prevent water ingress. 2. Mounting: Securely fix the unit using the four mounting holes accessible from the front. Use round cables to avoid water ingress. Wiring It is recommended that the installation and maintenance of this equipment be performed by suitably qualified/trained personnel, referencing the current edition of the I.E.E. wiring regulations (BS7671). These regulations contain important requirements regarding the Warning! Isolate the mains supply before commencing any work on the unit. Failure to do so could result in serious injury or fatality. Cable Glands: The unit is fitted with three cable glands. Only one cable should be fitted per gland to maintain the unit’s IP rating. For connecting four lamps, refer to the ‘Wiring Diagram’ on the next page for an alternative configuration using two junction boxes. Mains Supply Connection: Connect the mains supply to the terminal block marked ‘LINE’. o Live (L) to ‘L’ terminal o Neutral (N) to ‘N’ terminal o Earth (E) to ‘E’ terminal Lamp Connection: Connect the lamps to the terminal block marked ‘LOAD’. o Live (L) to ‘L’ terminal o Neutral (N) to ‘N’ terminal o Earth (E) to ‘E’ terminal Earth Continuity: Ensure all earth wires are connected to maintain earth continuity to the lamp fittings. Final Check: Verify all wiring connections and ensure the cable glands are tightened.
X20021 Infrared Heating | Heater Controller Infresco-T 6kW Controller 6000W, 240v Advanced Energy-Saving Solution for Heating and Lighting BMF House - Wight Moss Way, Southport Business Park Southport PR8 4HQ ENGLAND, UNITED KINGDOM Contact Us: 0044 (0) 1704-516 501 enquiries@united-automation.com www.united-automation.com unitedautomationltd UA_Limited 17 November 2025 | Issue: 9 Page 3 of 5 Commissioning 1. On-Time Preset: Set the on-time preset (VR2) to a period between 1 and 60 minutes. Refer to the ‘Mounting Template’ to locate VR2. 2. Final Setup: Replace the lid and switch on the mains supply to the unit. 3. Testing: Press the push-button on the front of the unit to switch the lamps on. By following these guidelines, you ensure a safe and effective installation and operation of your Infresco unit. MOUNTING TEMPLATE Use these template dimensions to locate the 4 mounting-hole centres prior to drilling. IMPORTANT! Drilling of any holes through the enclosure will immediately invalidate the warranty of the unit. The unit MUST be orientated with the cable glands facing down.
X20021 Infrared Heating | Heater Controller Infresco-T 6kW Controller 6000W, 240v Advanced Energy-Saving Solution for Heating and Lighting BMF House - Wight Moss Way, Southport Business Park Southport PR8 4HQ ENGLAND, UNITED KINGDOM Contact Us: 0044 (0) 1704-516 501 enquiries@united-automation.com www.united-automation.com unitedautomationltd UA_Limited 17 November 2025 | Issue: 9 Page 4 of 5 WIRING DIAGRAM
X20021 Infrared Heating | Heater Controller Infresco-T 6kW Controller 6000W, 240v Advanced Energy-Saving Solution for Heating and Lighting BMF House - Wight Moss Way, Southport Business Park Southport PR8 4HQ ENGLAND, UNITED KINGDOM Contact Us: 0044 (0) 1704-516 501 enquiries@united-automation.com www.united-automation.com unitedautomationltd UA_Limited 17 November 2025 | Issue: 9 Page 5 of 5 TROUBLESHOOTING Warning! Isolate the mains supply before commencing any work on the unit. Failure to do so could result in serious injury or fatality. Problem Solution Lamps do not switch on
- Check the mains supply to the unit is switched on.
- Check the LINE and LOAD wiring connections to the unit and lamps. Fit a lamp that you know is in working order.
- Contact your supplier. Lamps do not switch off.
- Check the on-time preset (VR2) is set correctly.
- Contact your supplier. RECOMMENDATION & SAFETY REQUIREMENTS DOCUMENTS Other documents, which may be appropriate for your applications, are available on request. Code Identity Description X10255 SRA Safety requirements: Addressing the Low Voltage Directive (LVD) including Thermal data/Cooling, Live parts warning, Earthing requirements & Fusing recommendations P01.1 COS UAL Conditions of Sale NOTE: It is recommended that installation and maintenance of this equipment should be carried out by suitably qualified personnel, with reference to the current edition of the I.E.T. Wiring Regulations BS7671. The regulations contain important requirements regarding the safety of electrical equipment. ELECTROSTATIC DISCHARGE (ESD) This product range has been identified as requiring protection from electrostatic discharge (ESD). They include integrated circuits (IC’s) that may be damaged or degraded if mishandled. They are much less vulnerable when built in-circuit and suitable and sufficient precautions are taken when being handled. To address this matter, when the products are sold separately, they are protected in an ANTI-STATIC polyethylene bag. Appropriate care should be taken when handling the units for installation. OPTIONAL EXTRAS Product Code Product Description A-HL-E72C-1 Wall Mounted Patio Heater 1.5kW (no remote) PRODUCT CODE AND RELATED PRODUCT CODE Product Code Product Description A86390 Infresco-T 6kW Controller-Advanced Energy-Saving Solution for Heating and Lighting