REV 1.0.9 8/29/02 Characteristics subject to change without notice. 1 of 22 www.xicor.com 2-Wire RTC Real Time Clock/Calendar

FEATURES

  • Real Time Clock/Calendar —Tracks time in Hours, Minutes, and Seconds —Day of the Week, Day, Month, and Year
  • 2 Polled Alarms (Non-volatile) —Settable on the Second, Minute, Hour, Day of the Week, Day, or Month —Repeat Mode (periodic interrupts)
  • Oscillator Compensation on chip —Internal feedback resistor and compensation capacitors —64 position Digitally Controlled Trim Capacitor —6 digital frequency adjustment settings to ±30ppm
  • Battery Switch or Super Cap Input
  • 2-Wire™ Interface interoperable with I2C* —400kHz data transfer rate
  • Low Power CMOS —1.25µA Operating Current (Typical)
  • Small Package Options —8-Lead SOIC and 8-Lead TSSOP

APPLICATIONS

  • Utility Meters
  • HVAC Equipment
  • Audio / Video Components
  • Set Top Box / Television
  • Modems
  • Network Routers, Hubs, Switches, Bridges
  • Cellular Infrastructure Equipment
  • Fixed Broadband Wireless Equipment
  • Pagers / PDA
  • POS Equipment
  • Test Meters / Fixtures
  • Office Automation (Copiers, Fax)
  • Home Appliances
  • Computer Products
  • Other Industrial / Medical / Automotive

DESCRIPTION

The X1205 device is a Real Time Clock with clock/ calendar, two polled alarms, oscillator compensation, and battery backup switch. The oscillator uses an external, low-cost 32.768kHz crystal. All compensation and trim components are integrated on the chip. This eliminates several external discrete components and a trim capacitor, saving board area and component cost. The Real-Time Clock keeps track of time with separate registers for Hours, Minutes, and Seconds. The Calendar has separate registers for Date, Month, Y ear and Day-of-week. The calendar is correct through 2099, with automatic leap year correction. X1205 Preliminary Information BLOCK DIAGRAM Oscillator Frequency Timer LogicDivider Calendar 32.768kHz Control Registers 1Hz Time Keeping Registers Alarm Regs Compare Mask IRQ Control Decode Logic Alarm (EEPROM) (EEPROM)SCL SDA Serial Interface Decoder Interrupt Enable Registers Status (SRAM) Alarm Alarm (SRAM) OSC Compensation *I2C is a Trademark of Philips. New Features Repetitive Alarms & Temperature Compensation

X1205 – Preliminary Information REV 1.0.9 8/29/02 Characteristics subject to change without notice. 3 of 22 www.xicor.com the course of a read operation. In this device, the time is latched by the read command (falling edge of the clock on the ACK bit prior to RTC data output) into a separate latch to avoid time changes during the read operation. The clock continues to run. Alarms occurring during a read are unaffected by the read operation. Writing to the Real Time Clock The time and date may be set by writing to the RTC registers. To avoid changing the current time by an uncompleted write operation, the current time value is loaded into a separate buffer at the falling edge of the clock on the ACK bit before the RTC data input bytes, the clock continues to run. The new serial input data replaces the values in the buffer. This new RTC value is loaded back into the RTC Register by a stop bit at the end of a valid write sequence. An invalid write operation aborts the time update procedure and the contents of the buffer are discarded. After a valid write operation the RTC will reflect the newly loaded data beginning with the next “one second clock cycle” after the stop bit is written. The RTC continues to update the time while an RTC register write is in progress and the RTC continues to run during any nonvolatile write sequences. A single byte may be written to the RTC without affecting the other bytes. Accuracy of the Real Time Clock The accuracy of the Real Time Clock depends on the frequency of the quartz crystal that is used as the time base for the RTC. Since the resonant frequency of a crystal is temperature dependent, the RTC perfor- mance will also be dependent upon temperature. The frequency deviation of the crystal is a function of the turnover temperature of the crystal from the crystal’s nominal frequency. For example, a >20ppm frequency deviation translates into an accuracy of >1 minute per month. These parameters are available from the crystal manufacturer. Xicor’s RTC family provides on- chip crystal compensation networks to adjust load- capacitance to tune oscillator frequency from +116 ppm to –37 ppm when using a 12.5 pF load crystal. For more detail information see the Application section. CLOCK/CONTROL REGISTERS (CCR) The Control/Clock Registers are located in an area accessible following a slave byte of “1101111x” and reads or writes to addresses [0000h:003Fh]. The clock/control memory map has memory addresses from 0000h to 003Fh. The defined addresses are described in the Table 1. Writing to and reading from the undefined addresses are not recommended. CCR access The contents of the CCR can be modified by perform- ing a byte or a page write operation directly to any address in the CCR. Prior to writing to the CCR (except the status register), however, the WEL and RWEL bits must be set using a two step process (See section “Writing to the Clock/Control Registers.”) The CCR is divided into 5 sections. These are: 1. Alarm 0 (8 bytes; non-volatile) 2. Alarm 1 (8 bytes; non-volatile) 3. Control (4 bytes; non-volatile) 4. Real Time Clock (8 bytes; volatile) 5. Status (1 byte; volatile) Each register is read and written through buffers. The non-volatile portion (or the counter portion of the RTC) is updated only if RWEL is set and only after a valid write operation and stop bit. A sequential read or page write operation provides access to the contents of only one section of the CCR per operation. Access to another sec- tion requires a new operation. Continued reads or writes, once reaching the end of a section, will wrap around to the start of the section. A read or write can begin at any address in the CCR. It is not necessary to set the RWEL bit prior to writing the status register. Section 5 supports a single byte read or write only. Continued reads or writes from this section terminates the operation. The state of the CCR can be read by performing a ran- dom read at any address in the CCR at any time. This returns the contents of that register location. Addi- tional registers are read by performing a sequential read. The read instruction latches all Clock registers into a buffer, so an update of the clock does not change the time being read. A sequential read of the CCR will not result in the output of data from the mem- ory array. At the end of a read, the master supplies a stop condition to end the operation and free the bus. After a read of the CCR, the address remains at the previous address +1 so the user can execute a current address read of the CCR and continue reading the next Register. ALARM REGISTERS There are two alarm registers whose contents mimic the contents of the RTC register, but add enable bits and exclude the 24 hour time selection bit. The enable bits specify which registers to use in the comparison between the Alarm and Real Time Registers. For example:

Characteristics subject to change without notice. Table 1. Clock/Control Memory Map

0037 RTC (SRAM) Y2K 0 0 Y2K21 Y2K20 Y2K13 0 0 Y2K10 20h

0036 DW 0 0 0 0 0 DY2 DY1 DY0 0-6 00h

0035 YR Y23 Y22 Y21 Y20 Y13 Y12 Y11 Y10 0-99 00h

0034 MO 0 0 0 G20 G13 G12 G11 G10 1-12 00h

0033 DT 0 0 D21 D20 D13 D12 D11 D10 1-31 00h

0032 HR MIL 0 H21 H20 H13 H12 H11 H10 0-23 00h

0031 MN 0 M22 M21 M20 M13 M12 M11 M10 0-59 00h

0030 SC 0 S22 S21 S20 S13 S12 S11 S10 0-59 00h

0013 Control

0012 ATR 0 0 ATR5 ATR4 ATR3 ATR2 ATR1 ATR0 00h

0011 INT IM AL1E AL0E 0 0 X X X 00h

0009 MNA1 EMN1 A1M22 A1M21 A1M20 A1M13 A1M12 A1M11 A1M10 0-59 00h

0008 SCA1 ESC1 A1S22 A1S21 A1S20 A1S13 A1S12 A1S11 A1S10 0-59 00h

0007 Alarm0

0006 DWA0 EDW0 0 0 0 0 DY2 DY1 DY0 0-6 00h

0005 YRA0 Unused – Default = RTC Year value – Future expansion

0004 MOA0 EMO0 0 0 A0G20 A0G13 A0G12 A0G11 A0G10 1-12 00h

0003 DTA0 EDT0 0 A0D21 A0D20 A0D13 A0D12 A0D11 A0D10 1-31 00h

0002 HRA0 EHR0 0 A0H21 A0H20 A0H13 A0H12 A0H11 A0H10 0-23 00h

0001 MNA0 EMN0 A0M22 A0M21 A0M20 A0M13 A0M12 A0M11 A0M10 0-59 00h

0000 SCA0 ESC0 A0S22 A0S21 A0S20 A0S13 A0S12 A0S11 A0S10 0-59 00h

and MNAn* registers are set to 9:30PM.

Characteristics subject to change without notice. default value is defined as ‘0’.

24 Hour Time

the leap year in the year 2100. the Clock/Control Registers (CCR). Table 2. Status Register (SR) bits that are set when an SR read starts will be reset.

Characteristics subject to change without notice. AL1E and AL0E bits are set to “1”, respectively. alarms respectively, indicate if an alarm has happened. rate set by the time setting fo the alarm. is set, then this pulse will be periodic. the ppm error to achieve better accuracy. adjustment and DTR0 gives 20 ppm adjustment. Table 3. Digital Trimming Registers vided to adjust the on-chip loading capacitance range. from 3.25pF to 18.75pF in 0.25pF steps.

0 Single Time Event Set By Alarm

1 Repetitive / Recurring Time Event Set By Alarm

X1205 – Preliminary Information ABSOLUTE MAXIMUM RATINGS Voltage on V CC, VBACK and IRQ Voltage on SCL, SDA, X1 and X2 above V CC or VBACK (whichever is higher) Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and the functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute max- imum rating conditions for extended periods may affect device reliability. DC OPERATING CHARACTERISTICS (Temperature = -40°C to +85°C, unless otherwise stated.) OPERATING CHARACTERISTICS Symbol Parameter Conditions Min Typ Max Unit Notes VCC Main Power Supply 2.7 5.5 V VBACK Backup Power Supply 1.8 5.5 V VCB Switch to Backup Supply V BACK -0.2 V BACK -0.1 V VBC Switch to Main Supply V BACK VBACK +0.2 V Symbol Parameter Conditions Min Typ Max Unit Notes ICC1 Read Active Supply Current VCC = 2.7V 400 µA 1, 5, 7, 14VCC = 5.5V 800 µA ICC2 Program Supply Current (nonvolatile) VCC = 2.7V 2.5 mA 2, 5, 7, 14VCC = 5.5V 3.0 mA ICC3 Main Timekeeping Current VCC = 2.7V 5 µA 3, 7, 8, 14, 15VCC = 5.5V 10 µA IBACK Timekeeping Current VBACK = 1.8V 1.25 µA 3, 6, 9, 14, 15 “See Perfor- mance Data”VBACK = 3.3V 1.5 µA ILI Input Leakage Current 10 µA 10 ILO Output Leakage Current 10 µA 10 VIL Input LOW Voltage -0.5 VCC x 0.2 or VBACK x 0.2 V1 3 VIH Input HIGH Voltage VCC x 0.7 or VBACK x 0.7 VCC + 0.5 or VBACK + 0.5 V1 3 VHYS Schmitt Trigger Input Hysteresis VCC related level .05 x VCC or .05 x VBACK V1 3 VOL Output LOW Voltage for SDA/IRQ VCC = 2.7V 0.4 V1 1VCC = 5.5V 0.4

Address Byte are incorrect or until 200nS after a stop ending a read or write operation. (2) The device enters the Program state 200nS after a stop ending a write operation and continues for t WC. (4) For reference only and not tested. (13) Threshold voltages based on the higher of Vcc or Vback. (14) Using recommended crystal and oscillator network applied to X1 and X2 (25°C). Notes: (1) This parameter is not 100% tested. Figure 14. Standard Output Load for testing the device with VCC = 5.0V

X1205 – Preliminary Information AC Specifications (TA = -40°C to +85°C, VCC = +2.7V to +5.5V, unless otherwise specified.) Notes: (1) This parameter is not 100% tested. (2) Cb = total capacitance of one bus line in pF . TIMING DIAGRAMS Bus Timing Symbol Parameter Min. Max. Units fSCL SCL Clock Frequency 400 kHz tIN Pulse width Suppression Time at inputs 50 (1) ns tAA SCL LOW to SDA Data Out Valid 0.9 µs tBUF Time the bus must be free before a new transmission can start 1.3 µs tLOW Clock LOW Time 1.3 µs tHIGH Clock HIGH Time 0.6 µs tSU:STA Start Condition Setup Time 0.6 µs tHD:STA Start Condition Hold Time 0.6 µs tSU:DAT Data In Setup Time 100 ns tHD:DAT Data In Hold Time 0 µs tSU:STO Stop Condition Setup Time 0.6 µs tDH Data Output Hold Time 50 ns tR SDA and SCL Rise Time 20 +.1Cb (1)(2) 300 ns tF SDA and SCL Fall Time 20 +.1Cb (1)(2) 300 ns Cb Capacitive load for each bus line 400 pF tSU:STO tDH tHIGH tSU:STA tHD:STA tHD:DAT tSU:DATSCL SDA IN SDA OUT tF tLOW tBUFtAA tR

X1205 – Preliminary Information Write Cycle Timing Power Up Timing Notes: (1) Delays are measured from the time V CC is stable until the specified operation can be initiated. These parameters are not 100% tested. VCC slew rate should be between 0.2mV/µsec and 50mV/µsec. (2) Typical values are for T A = 25°C and VCC = 5.0V Nonvolatile Write Cycle Timing Note: (1) t WC is the time from a valid stop condition at the end of a write sequence to the end of the self-timed internal nonvolatile write cycle. It is the minimum cycle time to be allowed for any nonvolatile write by the user, unless Acknowledge Polling is used. Symbol Parameter Min. Typ. (2) Max. Units tPUR (1) Time from Power Up to Read 1 ms tPUW (1) Time from Power Up to Write 5 ms Symbol Parameter Min. Typ. (1) Max. Units tWC (1) Write Cycle Time 5 10 ms SCL SDA tWC 8th Bit of Last Byte ACK Stop Condition Start Condition

Table 6. Crystal Parameters Required for Xicor RTC’s Table 7. Crystal Manufacturers Manufacturer Part Number Temp Range +25°C Freq Toler.

note AN154 on Xicor’s website at www.xicor.com. Figure 15. Suggested Layout for Xicor RTC in SO-8 using the proper crystal and layout).

as an indication of proper oscillation. disappear intermittently for short periods of time. Figure 16. Supercapactor charging circuit or the battery will be drained. Table 8. Battery Backup Operation

  1. Example Application, Vcc=5V, Vback=3.0V
  2. Example Application, Vcc=3.3V,Vback=3.0V

X1205 – Preliminary Information Referring to Figure 16, Vtrip applies to the “Internal Vcc” node which powers the entire device. This means that if Vcc is powered down and the battery voltage at Vback is higher than the Vtrip voltage, then the entire chip will be running from the battery. If Vback falls to lower than Vtrip, then the chip shuts down and all out- puts are disabled except for the oscillator and time- keeping circuitry. The fact that the chip can be powered from Vback is not necessarily an issue since standby current for the RTC devices is <2µA for this mode (called “main timekeeping current ” in the data sheet). Only when the serial interface is active is there an increase in supply current, and with Vcc powered down, the serial interface will most likely be inactive. One way to prevent operation in battery backup mode above the Vtrip level is to add a diode drop (silicon diode preferred) to the battery to insure it is below Vtrip. This will also provide reverse leakage protection which may be needed to get safety agency approval. One mode that should always be avoided is the opera- tion of the RTC device with Vback greater than both Vcc and Vtrip (Condition 2d in Table 8). This will cause the battery to drain quickly as serial bus communica- tion and non-volatile writes will require higher supplier current. PERFORMANCE DATA I BACK Performance 1.4 1.2 1.0 0.8 0.6 0.4 0.2 IBACK vs. Temperature Multi-Lot Process Variation Data Temperature °C -40 25 60 85 IBACK (µA) 3.3V 1.8V

X1205 – Preliminary Information PACKAGING INFORMATION 0.150 (3.80) 0.158 (4.00) 0.228 (5.80) 0.019 (0.49) Pin 1 Pin 1 Index 0.010 (0.25) 0.020 (0.50) 0.050 (1.27) 0.188 (4.78) 0.197 (5.00) 0.004 (0.19) 0.010 (0.25) 0.053 (1.35) 0.069 (1.75) (4X) 7° 0.016 (0.410) 0.037 (0.937) 0.0075 (0.19) 0.010 (0.25) 0° - 8° X 45° 8-Lead Plastic, SOIC, Package Code S8 NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 0.250" 0.050"Typical 0.050" Typical 0.030" Typical

8 PlacesFOOTPRINT

X1205 – Preliminary Information PACKAGING INFORMATION NOTE: ALL DIMENSIONS IN INCHES (IN PARENTHESES IN MILLIMETERS) 8-Lead Plastic, TSSOP, Package Code V8 See Detail “A” .031 (.80) .041 (1.05) .169 (4.3) .025 (.65) BSC .114 (2.9) .122 (3.1) .002 (.05) .006 (.15) .047 (1.20) .0075 (.19) .0118 (.30) 0° – 8° .010 (.25) .019 (.50) .029 (.75) Gage Plane Seating Plane Detail A (20X) (4.16) (7.72) (1.78) (0.42) (0.65) All Measurements Are Typical

X1205 – Preliminary Information ©Xicor, Inc. 2001 Patents PendingLIMITED WARRANTY Devices sold by Xicor, Inc. are covered by the warranty and patent indemni fication provisions appearing in its Terms of Sale only. Xicor, Inc. makes no warranty, express, statutory, implied, or by description regarding the information set forth herein or regarding the freedom of the descr ibed devices from patent infringement. Xicor, Inc. makes no warranty of merchantability or fitness for any purpose. Xicor, Inc. reserves the right to discontinue production and change specifications and prices at any time and without notice. Xicor, Inc. assumes no responsibility for the use of any circuitry other than circuitry embodied in a Xicor, Inc. product. No other circuits, patents, or licenses are implied. COPYRIGHTS AND TRADEMARKS Xicor, Inc., the Xicor logo, E2POT, XDCP, XBGA, AUTOSTORE, Direct Write cell, Concurrent Read-Write, PASS, MPS, PushPOT, Block Lock, IdentiPROM, E2KEY, X24C16, SecureFlash, and SerialFlash are all trademarks or registered trademarks of Xicor, Inc. All other brand and product names mentioned herein are used for identification purposes only, and are trademarks or registered trademarks of their respective holders. U.S. PATENTS Xicor products are covered by one or more of the following U.S. Patents: 4,326,134; 4,393,481; 4,404,475; 4,450,402; 4,486,769; 4,488,060; 4,520,461; 4,533,846; 5,161,137; 5,219,774; 5,270,927; 5,324,676; 5,434,396; 5,544,103; 5,587,573; 5,835,409; 5,977,585. Foreign patents and additional patents pending. LIFE RELATED POLICY In situations where semiconductor component failure may endanger life, system designers using this product should design the system with appropriate error detection and correction, redundancy and back-up features to prevent such an occurrence. Xicor’s products are not authorized for use in critical components in life support devices or systems. 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.

ORDERING INFORMATION

VCC Range Package Operating Temperature Range Part Number 2.7-5.5V 8L SOIC 0 –70°C X1205S8 -40–85°C X1205S8I 8L TSSOP 0 –70°C X1205V8 -40–85°C X1205V8I 8-Lead TSSOP YWW XXXXX 1205 = 2.7 to 5.5V, 0 to +70°C 8-Lead SOIC X1205 X YWW XX Blank = 8-Lead SOIC Blank = 2.7 to 5.5V, 0 to +70°C I = 2.7 to 5.5V, -40 to 85°C1205I = 2.7 to 5.5V, -40 to 85°C