MORNSUN reserves the copyright Specifications subject to change without notice. WRE_CKS-1W & WRF_CKS-1W A/0-2008 Page 1 of 2 WRE_CKS-1W & WRF_CKS-1W Series 1W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT SIP DC-DC CONVERTER multi-country patent protection RoHS PRODUCT PROGRAM Input Output Voltage (VDC) Current (mA) Part Number Nominal Range Max** Voltage (VDC) Max Min Efficiency (%, Typ) WRE0505CKS-1W * ±5 ±100 ±10 72 WRE0509CKS-1W * ±9 ±55 ±6 74 WRE0512CKS-1W * ±12 ±42 ±4 76 WRE0515CKS-1W * ±15 ±33 ±3 75 WRF0505CKS-1W * 5 200 20 72 WRF0509CKS-1W * 9 111 11 74 WRF0512CKS-1W * 12 83 8 76 WRF0515CKS-1W * 5 4.5-9.0 11 15 67 7 75 WRE1205CKS-1W ±5 ±100 ±10 76 WRE1209CKS-1W ±9 ±55 ±6 78 WRE1212CKS-1W ±12 ±42 ±4 80 WRE1215CKS-1W ±15 ±33 ±3 80 WRF1205CKS-1W 5 200 20 76 WRF1209CKS-1W 9 111 11 78 WRF1212CKS-1W 12 83 8 80 WRF1215CKS-1W 12 9.0-18 22 15 67 7 80 WRE2405CKS-1W ±5 ±100 ±10 78 WRE2409CKS-1W ±9 ±55 ±6 79 WRE2412CKS-1W ±12 ±42 ±4 81 WRE2415CKS-1W ±15 ±33 ±3 81 WRF2405CKS-1W 5 200 20 76 WRF2409CKS-1W 9 111 11 78 WRF2412CKS-1W 12 83 8 81 WRF2415CKS-1W 24 18-36 40 15 67 7 81 WRE4805CKS-1W * ±5 ±100 ±10 76 WRE4809CKS-1W * ±9 ±55 ±6 78 WRE4812CKS-1W * ±12 ±42 ±4 80 WRE4815CKS-1W * ±15 ±33 ±3 80 WRF4805CKS-1W * 5 200 20 76 WRF4809CKS-1W * 9 111 11 78 WRF4812CKS-1W * 12 83 8 80 WRF4815CKS-1W * 48 36-72 80 15 67 7 80 * Designing. **Input voltage can’t exceed this value, or will cause the permanent damage. Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically. Operation under 10% load will not damage the converter; However, they may not meet all specification listed. OUTPUT SPECIFICATIONS Item Test Conditions Min Typ Max Units Output power 0.1 1 W Positive voltage accuracy Refer To Recommended Circuit ±1 ±3 Negative voltage accuracy Refer To Recommended Circuit ±3 ±5 10% to 100% load(WRF_CKS-1W) ±0.5 ±0.75 Load Regulation 10% to 100% load(WRE_CKS-1W) * ±0.75 ±1.0 Line Regulation Input voltage from Low To high ±0.2 ±0.5 Temperature Drift (Vout) Refer to recommended circuit ±0.03 %/°C Ripple & Noise** 20MHz Bandwidth 25 75 mVp-p Switching Frequency Input voltage range 100% load 300 KHz * Dual output models unbalanced load(25/100%): ±5%Max. **Test ripple and noise by “parallel cable ” method. See detailed operation instructions at Testing of Power Converter section, application notes.

FEATURES

Efficiency up to 81% Wide (2:1) Input Range I/O Isolation 3000VDC Short circuit protection(automatic recovery) External On/Off control Internal SMD construction Operating Temperature: -40°C to +85°C RoHS Compliance

APPLICATIONS

The WRE_CKS-1W & WRF_CKS-1W Series are specially designed for applications where a wide range i nput voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is wide range (voltage range≤ 2:1); 2) Where isolation i s necessary between input and output(isolation voltage≤3000VDC); 3) Where the regulation of the output voltage and the output ripple noise are demanded. MODEL SELECTION WRE2412CKS-1W Product Series Input Voltage Output Voltage Package Style Rated Power MORNSUN Science & Technology co.,Ltd. Address: 2th floor 6th building, Huangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax:86-20-38601272 Http://www.mornsun-power.com

MORNSUN reserves the copyright Specifications subject to change without notice. WRE_CKS-1W & WRF_CKS-1W A/0-2008 Page 2 of 2 COMMON SPECIFICATION APPLICATION NOTE Item Test Conditions Min Typ Max Units Storage Humidity 95 % Operating Temperature -40 85 Storage Temperature -55 125 Temp. Rise at Full Load 15 Lead Temperature 1.5mm from case for 10 seconds 300 Isolation voltage Tested for 1 minute and 1mA max 3000 VDC Isolation resistance Test at 500VDC 1000 M Ω Isolation Capacitance 100KHz,1V 35 PF No-load power consumption 120 mW Cooling Free Air Convection Short Circuit Protection Continuous, Automatic recovery Case Material Plastic(UL94-V0) MTBF 1000 K hours Weight 5 g Note: 1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 4. See below recommended circuits for more details. TYPICAL TEMPERATURE CURVE Operating Temp.( )C 100 OUTLINE DIMENSIONS & FOOTPRINT DETAILS FOOTPRINT DETAILS RECOMMENDED FOOTPRINT Top view,grid:2.54mm(0.1inch), diameter:1.00mm(0.039inch) Note: Unit:mm(inch) Pin section:0.50*0.30mm(0.020*0.012inch) Pin section tolerances:0.10mm(0.004inch) General tolerances:0.25mm(0.010inch) + + + + Dual/Single Output Pin Single Dual GND Vin +Vo NC 0V7 CTRL -Vo GND Vin +Vo NC CTRL CS (0.866) 12.00 0.50 4.10 23526781 NC:No Connection First Angle Projection 3 5 Side View Bottom View Recommended circuit If you want to further decrease the input/output ripple, an “LC” filtering network may be connected to the input an d output ends of the DC/DC converter, see (Figure 1). Single Output +Vo Cout Cs Cin Vin GND 3Vc R Lin IcD1 Dual Output +Vo Cout Cout Lout Lout -Vo Cin Vin GND Vc R Lin IcD1 (Figure 1) However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest capacitance of its filter capacitor sees (Table 1). General: Cin: 5V,12V 100 μF 24V,48V 10 μF Cout: 47 μF(Typ.) Lin: 4.7 μH -120μH Lout: 2.2 μH-10μH Cs: 10 μF-22μF External Capacitor Table(Table 1) Single Vout (VDC) Cout (μF) Dual Vout (VDC) Cout (μF) 5 680 ±5 330 9 560 ±9 270 12 470 ±12 220 15 330 ±15 150 CTRL Terminal When open or high impedance,the conve rter work well; When this pin is ‘high’; the converter shutdown; It should be note that the input current (Ic) should between 5- 10mA, exceeding the maximum 20mA will cause permanence damage to the converter. The value of R Can be derived as follows : Input current While using unstable power source, please ensure the output voltage and ripple voltage do not excced indexes of the converter. The preceding power source must be able to provide for converter sufficient starting current Ip (Figure 2).General: Ip ≤1.4*Iin-max Input Current(A) Input Voltage (V) Input Voltage Range Ip No parallel connection or plug and play. VC-VD -1.0 Ic