Features

Many Variations in Standard Limit Switches A Wide Range of Models The series includes includes many different actuators that you select to match the workpiece shape and motion, and a wide range of Switch variations, such as models with operation indicators for easier working and maintenance and models with different types of connectors. Select from Six Types of Environment Resistance The series includes Airtight Switches, Hermetic Switches, Heat- resistant Switches, Low-temperature Switches, Corrosion-proof switches, and Weather-proof Switches. You can select the model based on the onsite environment. Excellent Performance on Arc Welding Lines or Sites with Spattering Cutting Powder Ideal for Welding Sites These Switches use stainless steel or resin to prevent the adhesion of spatter. They can be used to reduce problems caused by zinc power generated during welding. Mechanical Endurance of 30 Million Operations Long-life Models for High-frequency Applications A mechanical durability of 30 million operations minimum is provided. The head features a double-seal structure with a head cap and oil seal. DPDB Operation The double-pole, double-break structure ensures circuit braking. Degree of Protection; IP67 Approved Standards to Aid Export Machines The Switches are certified for EN/IEC, UL, cUL, and CCC making them ideal for export machines. Applicable to Either Standard Loads or Microloads Standard-feature gold-clad contacts provide high reliability. The use of a high-contact-pressure crossbar structure also increases reliability. Easy to Work With Downsizing of the built-in switch has increased the space to house the wiring. The insulating paper that was often in the way when wiring has been eliminated. Nickle-plated steel screws are used for the terminal screws. The screws adhere to magnetized screwdrivers to prevent dropping and loosing them. Models with Connectors to Reduce Wiring A neon lamp or LED indicates the operating status. The 3D structure of the lamp cover disperses light so you can check the operating status from the side. Standard Switches Environment-resistant Switches Spatter-prevention Switches Long-life Switches Features Common to All Switches Load Load 13(NO) Za 11(NC) (NO)14 (NC)12

  • Basic Switches WLC@-N Operation indicators Sensor I/O connectors
  • High-sensitivity Switches WLG@-N
  • High-precision Switches WLGCA2-N
  • Protective Switches WLCA32-@-N
  • Indicator-equipped Switches: Light emitting diodes (LED) WL@-LD-N
  • Indicator-equipped Switches: Neon lamps WL@-LE-N
  • Direct-wired Switches WL-@LDK@-N
  • Pre-wired Switches WL@-@LD-M1@-N WL@-@LD-AGJ-N WL@-@LD-DGJ-N WL@-@LD-DK1EJ-N Environment-resistant Spatter-prevention Long-life
  • High-precision Switches WLGCA2-@S-N
  • Airtight Switches WL@-55-N
  • Hermetic Switches WL@-139-N WL@-140-N WL@-141-N WL@-145-N WL@-RP40-N WL@-RP60-N
  • Heat-resistant Switches WL@-TH-N
  • Low-temperature Switches WL@-TC-N
  • Corrosion-proof Switches WL@-RP-N
  • Weather-proof Switches WL@-P1-N
  • Basic Switches WLC@-@S-N
  • High-sensitivity Switches WLG@-@S-N
  • High-precision Switches WLMGCA2-@-N
  • Basic Switches WLMCA2-@-N
  • High-sensitivity Switches WLMG2-@-N

Environment-resistant Switches Item Environment-resistant Type Model Application Environment-resistant construction Applicable models Airtight seal WL@-55-N For uses in locations sub- ject to cutting oil or water Uses an airtight built-in switch. Note: Use the SC Connector for the conduit opening. All models except the low- temperature and heat-re- sistant models Note: Models can be produced using standard actuators. Hermetic seal (Molded terminals/ Anti-coolant) WL@-139-N Refer to page 29 for information on the environ- ment-resistant construction of Switches with Her- metic Seals. All models except the low- temperature and heat-re- sistant models Note: Models can be produced using standard actuators. Only the WLCA2-N, WLGCA2-N, or WLG2-N can be produced for the WL@- 141-N and WL@-145-N. WL@-140-N WL@-141-N WL@-145-N WL@-RP40-N WL@-RP60-N Low-temperature WL@-TC-N Can be used at a tempera- ture of –40°C (operating temperature range: –40 to 40°C), but cannot with- stand icing.  Uses a general-purpose built-in switch.  Epichlorhydrin rubber is used for rubber parts such as the O-ring, gasket, etc. All models except airtight seal, hermetic seal, heat- resistant, corrosion-proof, and indicator-equipped models Heat-resistant WL@-TH-N Can be used in tempera- tures of 120°C (operating temperature range: 5 to 120°C).  Fluorine rubber is used for rubber parts such as the O-ring, gasket, etc. All models except airtight seal, hermetic seal, heat- resistant, corrosion-proof, and indicator-equipped, ny- lon roller (WLCA2-26N-N), seal roller models, and res- in rod (WLNJ-2-N) models Corrosion-proof WL@-RP-N For use in locations sub- ject to corrosive gases and chemicals.  Diecast parts, such as the switch box, are made of corrosion-proof aluminum.  Rubber sealing parts are made of fluorine rubber, which aids in resisting oils and chemicals.  Exposed nuts and screws (except the actuator section) are made of stainless steel.  Moving and rotary parts such as rollers are made of sintered stainless steel or stainless steel.  The Head, box, and cover are yellow. All models except fork lever lock (WLCA32-41 to -44- N), low-temperature, heat- resistant, and indicator- equipped models Weather-proof WL@-P1-N For use in parking lots and other outdoor locations.  Rubber parts are made from epichlorhydrin rubber, which has a high-tolerance to changes in temperature.  Rollers are made of stainless steel to improve corrosion resistance.  Exposed nuts and screws are made of stainless steel. Only basic (WLCA2-N/ CA12-N/CL-N), and high- sensitivity overtravel (WLG2-N/G12-N/GL-N) models (excluding heat-re- sistant models). This does not apply to Low- temperature or Heat-resis- tance, or Indicator- equipped Switches.

With the WL-N Series, OMRON will combine the switch, Actuator, and wiring method required to build the ideal switch for your application. *1. Not all functions can be combined with environment-resistant switches. Refer to the applicable models on the previous page. *2. Refer to page 29 for information on the construction of Hermetic Switches. The WL-N Series consists of four basic types: General-purpose, Environment-resistant, Spatter-protec- tion, and Long-life Switches. WLCA2-N Switches can be used for the most common applications. Normal High-temperature Low-temperature Outdoors −10°C +80°C +5°C +120°C −40°C +40°C Water-resistant to IP67. Environment Key specifications Models WL@-N General-purpose Switches WLM@-N Long-life Switches WL@-TH-N Heat-resistant Switches *1 WL@-TC-N Low-temperature Switches *1 WL@-P1-NW eather-proof Switches *1Water drops and mist Uses an airtight built-in switch. WL@-55-N Airtight Switches *1 WL@-RP-N Corrosion-proof Switches *1 WL@-S-N Spatter-prevention Switches Chemicals and oil WL@-139-N Hermetic, Molded-terminal Switches *1, *2 WL@-RP40-N Hermetic, Molded-terminal Switches *1, *2 WL@-140-N Hermetic, Molded-terminal Switches *1, *2 WL@-141-N, -145-N Hermetic, Molded-terminal Switches *1, *2 (Only the WLCA2 -N, WLG2-N, and WLGCA2-N, can be produced.) WL@-RP60-N Hermetic, Molded-terminal Switches *1, *2 According to Operating Environment To increase heat resistance, the rubber material (fluorine rubber) and the plunger material (PEEK) have been changed. Cables are attached. Uses a general-purpose built-in switch. The cover screws, case cover, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Cables are attached. Uses an airtight built-in switch. The cover screws, case cover, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Cables are attached. Uses an airtight built-in switch. The cover screws, case cover, and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) Double seal against oil including head cap countermeasure for cutting chips and an oil seal. -141: The Head section is molded from epoxy resin; Head direction cannot be changed. -145: The Head section is molded from epoxy resin; Head can be in an y of 4 directions. Cables are attached. Uses an airtight built-in switch. The case cover and conduit opening are molded from epoxy resin to increase the seal. (The cover cannot be removed.) The SC connector can be removed, so it is possible to use flexible conduit for the cable. To prevent spatter during welding, a heat-resistant resin is used for the indicator cover and screws and rollers are all made from stainless steel. Cables are attached. Uses an airtight built-in switch. The cover screws, case cover, conduit opening, and head screws are molded from epoxy resin to increase the seal. (The cover and head cannot be removed.) Rubber parts are made from fluorine rubber to increase resistance to coolant. Rubber parts are made from epichlorhydrin rubber, which has a high-tolerance to changes in temperature. Stainless steel is used for the screws. Rollers are made of stainless steel to provide superior corrosion resistance. Corrosion-proof specifications have been used for the housing, fluorine rubber has been used for rubber parts, and stainless steel has been used for screws and nuts (except for the actuator) to increase resistance to oils, chemicals, and weather. To increase resistance to cold, epichlorhydrin rubber and other measures are used. Ambient operating temperature Constant water drops and mist Coolant Spattering from welding Constant water drops or splattering cutting powder Operating environment

Conditions Key specifications Models According to Application Conditions Switching standard loads Switching microloads Normal durability Long-life

0.1 A at 125 VAC, resistive load

0.1 A at 30 VDC, resistive load

10 A at 125,250, or 500 VAC

0.8 A at 125 VDC

0.4 A at 250 VDC Entire WL@-@-N Series

Applicable to either standard loads or microloads. WL@-N General-purpose Switches WL@-S-N Spatter-pre vention Switches WLM@-N Long-life Switches Mechanical: 15 million operation min. (10 million operation min. for high-sensitivity models or flexible rod models) Mechanical: 30 million operation min. Durability Load According to Ease of Installation and Maintenance Connector attachment in control and relay boxes One-touch connector attachment Screw tightening and installation Daily inspections and maintenance checks LED 10 to 115 VAC/DC Switching light-ON between operating/not operating. (Switching not possible for models with molded terminals.) Neon lamp 125 to 250 VAC Switching light-ON between operating/not operating. (Switching is not possible for Switches with Molded Terminals.) Pre-wired connector, 4-conductor. Greatly reduces wiring work. Smartclick connectors for even easier maintenance. Direct-wired connector, 4-conductor. Greatly reduces wiring work. Pre-wired connector, 2-conductor. Greatly reduces wiring work. Smartclick connectors for even easier maintenance. Direct-wired connector, 2-conductor. Greatly reduces wiring work. Screw terminals. No ground terminal. Conduit siz e: G1/2 Screw terminals. Ground terminal. Conduit size: 4 sizes WL@-@LD-@GJ-N General-purpose, Pre-wired Connector Switches WL@-@S-@GJS-N Spatter-pre vention, Pre-wired Connector Switches WLM@-LD-@GJ-N Long-life, Pre-wired Connector Switches WL@-@LD-M1@J-N General-purpose, Pre-wired Connector Switches WL@-@S-M1@J-1-N Spatter-pre vention, Pre-wired Connector Switches WLM@-LD-M1@J-N Long-life, Pre-wired Connector Switches WL@-@LDK13@-N General-purpose, Direct-wired Connector Switches WLM@-LDK13@-N Long-life, Direct-wired Connector Switches WL@-@LDK43@-N General-purpose, Direct-wired Connector Switches WLM@-LDK43@-N Long-life, Direct-wired Connector Switches WL@-N General-purpose Switches WL@-N General-purpose Switches WLM@-N Long-life Switches WL@-LD-N General-purpose, Indicator-equipped (LED) Switches WL@-LDS-N Spatter-pre vention, Indicator-equipped (LED) Switches WL@-LE-N General-purpose, Indicator-equipped (Neon Lamp) Switches WL@-LES-N Spatter-pre vention, Indicator-equipped (Neon Lamp) Switches Conditions Key specifications Models Wiring specification Operation indicator

427.5 According to Form of Operation Detection object Key specifications Models Adjustable between dog and lever Cams or workpieces with vertical movement Round-trip operation of passing dogs Dogs or workpieces with large deflection Dogs and workpieces (Mounts in any of 4 directions) Passing dogs, high sensitivity General Passing dogs High precision

  • Short lever
  • One-Horizontal operation possible.
  • Head mounts in any of 4 directions.
  • Medium lever
  • One-side operation possible.
  • Head mounts in any of 4 directions.
  • Long lever
  • One-side operation possible.
  • Head mounts in any of 4 directions.
  • Head mounts in any of 4 directions.
  • Head mounts in any of 4 directions.
  • Head mounts in any of 4 directions.
  • Head mounts in any of 4 directions.
  • Head mounts in any of 4 directions.
  • Head mounts in any of 4 directions.
  • Equipped with sealing boot.
  • Equipped with sealing boot.
  • Equipped with sealing boot.
  • Head mounts in any of 4 directions.
  • One-side operation possible.
  • Head mounts in any of 4 directions.
  • One-side operation possible.
  • Head mounts in any of 4 directions.
  • One-Horizontal operation possible.
  • Head mounts in any of 4 directions.
  • One-Horizontal operation possible.
  • Head mounts in any of 4 directions. WLGCA2-N General-purpose Switches WLGCA2-@S-N Spatter-pre vention Switches WLMGCA2-N Long-life Switches WLG2-N General-purpose Switches WLG2-@S-N Spatter-pre vention Switches WLMG2-N Long-life Switches WLCA2-N General-purpose Switches WLCA2-2-N General-purpose Switches WLCA2-2N-N General-purpose Switches WLCA2-@S-N Spatter-pre vention Switches WLMCA2-N Long-life Switches WLSD2-N Horizontal-roller Plunger Actuator WLD28-N Sealed Top-roller Plunger Actuator WLSD3-N Horizontal-ball Plunger Actuator WLSD-N Horizontal Plunger Actuator WLD18-N Sealed Top Plunger Actuator WLD38-N Sealed Top-ball Plunger Actuator WLCA32-44-N Fork Le ver Lock Actuator WLCA32-43-N Fork Le ver Lock Actuator WLCA32-42-N Fork Le ver Lock Actuator WLCA32-41-N Fork Le ver Lock Actuator WLCAL5-N Rod Spring Le ver Actuator WLCAL4-N Adjustab le Rod Lever Actuator WLCL-N Adjustab le Rod Lever Actuators WL@12-N Adjustab le Roller Lever Actuators WL@2-8-N Roller Lever Actuators WL@2-7-N Roller Le ver Actuators WL@2-N Roller Le ver Actuators WL@2-@S-N Roller Le ver Actuators WLM@2-N Roller Le ver Actuators Actuators Operation angles 90° 90° 90° 90° 10° 90° 90° 25° 20°15° TT (total travel) PT (pretra vel) WLCA2-NW LCA2-2-NW LCA2-2N-N

Detection of Passing Pallets on Production Lines Detection of Work Table Origins (X, Y, and Z) on Machine Tools Detection of Forward and Reverse Movement of Hydraulic Cylinders on Molding Machines Detection of Arm Movement on Welding Robots Detection of Car Pallet Positions in Parking Towers Detection of Vertical Limits on Conveyor Systems

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) (1) Actuator and Property Specifications (2) Built-in Switch Type (3) Conduit Size, Ground Terminal Specifications * Models with ground terminals are certified for EN/IEC (CE Marking). (4) Indicator Type (5) Lever Type General-purpose Switches Code Lever Pretravel (PT) CA2 Roller lever: R38 mm 15±5° CA2-7 Roller lever: R50 mm CA2-8 Roller lever: R63 mm CA12 Adjustable roller lever: R25 to 89 mm CL Adjustable rod lever: 25 to 140 mm CAL4 Adjustable rod lever: 350 to 380 mm CAL5 Rod spring lever CA2-2 Roller lever: R38 mm 25±5°CA12-2 Adjustable roller lever: R25 to 89 mm CL-2 Adjustable rod lever: 25 to 140 mm CA2-2N Roller lever: R38 mm MAX 20°CA12-2N Adjustable roller lever: R25 to 89 mm CL-2N Adjustable rod lever: 25 to 140 mm G2 Roller lever, high sensitivity: R38 mm 10°G12 Adjustable roller lever, high sensitivity: R25 to 89 mm GL Adjustable rod lever, high sensitivity: 25 to 140 mm GCA2 Roller lever, high precision: R38 mm 5 ° CA32-41 Fork lever lock 50±5°CA32-42 Fork lever lock CA32-43 Fork lever lock D18 Sealed top plunger 1.7 mmD28 Sealed top-roller plunger D38 Sealed top-ball plunger SD Horizontal plunger 2.8 mmSD2 Horizontal-roller plunger SD3 Horizontal-ball plunger NJ Flexible rod: Coil spring 20±10 mm NJ-30 Flexible rod: Coil spring, multi-wire NJ-2 Flexible rod: Resin rod 40±20 mm NJ-S2 Flexible rod: Steel wire +2° −1° +2° Code Specification Blank Standard built-in switch

55 Airtight built-in switch

Conduit Size Ground terminal Blank G1/2 None G1 G1/2 Provided * G Pg13.5 YM 2 0 TS 1/2-14NPT Code Specifications Blank No indicator LE Neon lamp: 125 to 250 VAC LD LED (10 to 115 VAC/DC) Code Specifications Blank Standard lever (Allen-head bolt) A Double nut lever

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) (1) Actuator and Property Specifications (2) Built-in Switch Type (3) Indicator Type (4) Connector Type *1. DC models are certified for EN/IEC (CE Marking). *2. Refer to Contact Forms on page 16 for details on connector pin numbers. *3. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. General-purpose Switches Sensor I/O Connector Switches WL@ - @ LD @ -N (1) (2) (3) (4) Code Lever Pretravel (PT) CA2 Roller lever: R38 mm 15±5° G2 Roller lever, high sensitivity: R38 mm 10 ° GCA2 Roller lever, high precision: R38 mm 5 ° D28 Sealed top-roller plunger 1.7 mm +2° −1° +2° Code Specification Blank Standard built-in switch LD LED (10 to 115 VAC/DC) Code Specification Shape Voltage used *1 Wiring locations Connector pin No. *2 K13A Direct-wired connector Threaded (M12) AC NO only NO: K13 DC NO only NO: K43A AC NC+NO NC: , NO: K43 DC NC+NO NC: , NO: -M1J Pre-wired connector *3 Threaded (M12) DC NO only NO: -M1GJ DC NO only NO: -M1JB DC NC only NC: -AGJ AC NC+NO NC: , NO: -DGJ DC NC+NO NC: , NO: -DK1EJ DC NO only NC: , NO: -M1TJ Smartclick DC NO only NO: -M1TGJ DC NO only NO: -M1TJB DC NC only NC: -DTGJ DC NC+NO NC: , NO: -DTK1EJ DC NO only NC: , NO: 3 4 3 4 1 2 3 4 1 2 3 4 3 4 1 4 2 3 1 2 3 4 1 2 3 4 2 3 4 3 4 1 4 2 3 1 2 3 4 2 3 4

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) (1) Actuator and Property Specifications (2) Environment-resistant Model Specifications (3) Built-in Switch Type (4) Temperature Specifications *1. Cannot be combined with Corrosion-proof (RP) or Weather-proof (P1) Switches. (5) Hermetic Specification (6) Conduit Size, Ground Terminal Specifications *2. Models with ground terminals are certified for EN/IEC (CE Marking). (7) Indicator Type *3. Cannot be combined with Corrosion-proof (RP), Weather-proof (P1), Heat-resistant (TC), or Low-temperature (TC) Switches. (8) Indicator Wiring Specification *4. Always include the indicator wiring specification if you specify a (5) hermetic structure and an (7) indicator. (9) Lever Type Environment-resistant Switches Code Lever Pretravel (PT) CA2 Roller lever: R38 mm 15±5° CA2-7 Roller lever: R50 mm CA2-8 Roller lever: R63 mm CA12 Adjustable roller lever: R25 to 89 mm CL Adjustable rod lever: 25 to 140 mm CAL4 Adjustable rod lever: 350 to 380 mm CAL5 Rod spring lever CA2-2 Roller lever: R38 mm 25±5°CA12-2 Adjustable roller lever: R25 to 89 mm CL-2 Adjustable rod lever: 25 to 140 mm CA2-2N Roller lever: R38 mm MAX 20°CA12-2N Adjustable roller lever: R25 to 89 mm CL-2N Adjustable rod lever: 25 to 140 mm G2 Roller lever, high sensitivity: R38 mm 10°G12 Adjustable roller lever, high sensitivity: R25 to 89 mm GL Adjustable rod lever, high sensitivity: 25 to 140 mm GCA2 Roller lever, high precision: R38 mm 5 ° CA32-41 Fork lever lock 55°CA32-42 Fork lever lock CA32-43 Fork lever lock D18 Sealed top plunger 1.7 mmD28 Sealed top-roller plunger D38 Sealed top-ball plunger SD Horizontal plunger 2.8 mmSD2 Horizontal-roller plunger SD3 Horizontal-ball plunger NJ Flexible rod: Coil spring 20±10 mm NJ-30 Flexible rod: Coil spring, multi-wire NJ-2 Flexible rod: Resin rod 40±20 mm NJ-S2 Flexible rod: Steel wire Code Specifications Blank Standard RP Corrosion-proof P1 Weather-proof Code Specifications Blank Standard built-in switch Blank Standard: −10°C to +80°C TH Heat-resistant: +5 °C to +120°C *1 TC Low-temperature: −40°C to +40°C *1 +2° −1° +2° Code Specifications Blank No cable molding. 139 Standard built-in switch. Cable is attached. Molded conduit opening and cover. (The cover cannot be re- moved.) 140 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, and cover screws. (The cover cannot be removed.) 141 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, head, cover screws, and head screws. (The cover cannot be removed and the head direction cannot be changed.) Double seal against oil including head cap countermeasure for cutting chips and an oil seal. 145 Airtight built-in switch. Cable is attached. Molded conduit opening, cover, and cover screws. (The cover cannot be removed. The head can be mounted in any of 4 di- rections.) Double seal against oil including head cap countermeasure for cutting chips and an oil seal. RP40 Airtight built-in switch. Cable is attached. Molded conduit opening and cover. (The cover cannot be re- moved.) SC Connector can be removed, so it is possible to use flexible conduits for the cable. RP60 Airtight built-in switch. Cables are attached. Molded conduit opening, cover, cover screws, and head screws. (The cover cannot be removed and the head direction cannot be changed.) Fluorine rubber is used for all rubber parts. Code Specifications Conduit Size Ground terminal Blank G1/2 None G1 G1/2 Provided *2 G Pg13.5 YM 2 0 TS 1/2-14NPT Code Specifications Blank No indicator LE Neon lamp: 125 to 250 VAC LD LED (10 to 115 VAC/DC) Code Specifications

2 NC connection: Light-ON when operating

3 NO connection: Light-ON when not operating

Blank Standard lever (Allen-head bolt) A Double nut lever

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) (1) Actuator and Property Specifications (2) Built-in Switch Type (3) Indicator Type *1. Cannot be combined with a Switch with a Connector. (4) Connector Type *2. DC models are certified for EN/IEC (CE Marking). *3. Refer to Contact Forms on page 16 for details on connector pin numbers. *4. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. Spatter-prevention Switches Code Lever Pretravel (PT) CA2 Roller lever: R38 mm 15±5° G2 Roller lever, high sensitivity: R38 mm 10 ° GCA2 Roller lever, high precision: R38 mm 5 ° D28 Sealed top-roller plunger 1.7 mm Code Specifications Blank Standard built-in switch LE Neon lamp: 125 to 250 VAC *1 LD LED (10 to 115 VAC/DC) WL@ - @@S @ -N (1) (2) (3) (4) +2° −1° +2° Code Specifications Shape Voltage *2 Wiring locations Connector pin No. *3 Blank No connector - - - - - - - - - - - - - - - - -M1J-1 Pre-wired Connector *4 Threaded (M12) DC NO only NO: -M1GJ-1 DC NO only NO: -DGJS DC NC+NO NC: , NO: -DTGJS Smartclick DC NC+NO NC: , NO: 3 4 1 4 1 2 3 4 1 2 3 4

Model Number Legend (Not all combinations are possible. Contact your OMRON representative for details.) (1) Actuator and Property Specifications (2) Indicator Type (3) Connector Type *1. The standard cable length is 0.3 m. Contact your OMRON representative for information on other cable lengths. Long-life Switches Code Lever Pretravel (PT) CA2 Roller lever: R38 mm 15±5° G2 Roller lever, high sensitivity: R38 mm 10 ° GCA2 Roller lever, high precision: R38 mm 5 ° Code Specifications LD LED (10 to 115 VAC/DC) WLM@ -L D@ -N (1) (2) (3) +2° −1° +2° Code Specifications Shape Voltage Wiring locations Connector pin No. Blank Screw terminals: G1/2 conduit - - - - - - - - - - - - - - - - K13A Direct-wired connector Threaded (M12) AC NO only NO: K13 DC NO only NO: K43A AC NC+NO NC: , NO: K43 DC NC+NO NC: , NO: -M1J Pre-wired connector *1 Threaded (M12) DC NO only NO: -AGJ AC NC+NO NC: , NO: -DGJ DC NC+NO NC: , NO: -M1TJ Smartclick DC NO only NO: -ATGJ AC NC+NO NC: , NO: -DTGJ DC NC+NO NC: , NO: 3 4 3 4 1 2 3 4 1 2 3 4 3 4 1 2 3 4 1 2 3 4 3 4 1 2 3 4 1 2 3 4

Ordering Information

Switches with Lever Actuators Switches with Plunger Actuators Switches with Flexible Rod Actuators General-purpose Switches Actuator Roller lever R38 Roller lever: R50 Roller lever: R63 Item Pretravel (PT) Model Model Model Basic 15±5° WLCA2-N WLCA2-7-N WLCA2-8-N MAX20° WLCA2-2N-N ----- ----- High-sensitivity 10° WLG2-N ----- ----- High-precision 5° WLGCA2-N ----- ----- Actuator Adjustable roller lever Adjustable rod lever: 25 to 140mm Adjustable rod lever: 350 to 380mm Rod spring lever Item Pretravel (PT) Model Model Model Model Basic 15±5° WLCA12-N WLCL-N WLCAL4-N WLCAL5-N 25±5° WLCA12-2-N WLCL-2-N ----- ----- MAX20° WLCA12-2N-N WLCL-2N-N ----- ----- High-sensitivity 10° WLG12-N WLGL-N ----- ----- Actuator Fork lever lock Fork lever lock Fork lever lock Fork lever lock Item Movement until the lever reverses Model Model Model Model Protective 50±5° WLCA32-41-N WLCA32-42-N WLCA32-43-N WLCA32-44-N Actuator Sealed top plunger Sealed top-roller plunger Sealed top-ball plunger Item Pretravel (PT) Model Model Model Basic 1.7 mm WLD18-N WLD28-N WLD38-N Actuator Horizontal plunger Horizontal-roller plunger Horizontal-ball plunger Item Pretravel (PT) Model Model Model Basic 2.8 mm WLSD-N WLSD2-N WLSD3-N Actuator Coil spring (spring diameter: 6.5) Coil spring (spring diameter: 4.8) Item Pretravel (PT) Model Model Basic 20±10 mm WLNJ-N WLNJ-30-N Actuator Resin rod (rod diameter: 8) Steel wire (wire diameter: 1) Item Pretravel (PT) Model Model Basic 40±20 mm WLNJ-2-N WLNJ-S2-N Standard Switches +2° -1° +2° +2° -1°

Switches with Lever Actuators Switches with Plunger Actuators Switches with Flexible Rod Actuators General-purpose Switches Actuator Roller lever: R38 Roller lever: R50 Roller lever: R63 Indicator Item Pretravel (PT) Model Model Model Neon lamp Basic 15±5° WLCA2-LE-N WLCA2-7LE-N WLCA2-8LE-N MAX20° WLCA2-2NLE-N ----- ----- High-sensitivity 10° WLG2-LE-N ----- ----- High-precision 5° WLGCA2-LE-N ----- ----- LED Basic 15±5° WLCA2-LD-N WLCA2-7LD-N WLCA2-8LD-N MAX20° WLCA2-2NLD-N ----- ----- High-sensitivity 10° WLG2-LD-N ----- ----- High-precision 5° WLGCA2-LD-N ----- ----- Actuator Adjustable roller lever: Adjustable rod lever: 25 to 140mm Adjustable rod lever: 350 to 380mm Rod spring lever Indicator Item Pretravel (PT) Model Model Model Model Neon lamp Basic 15±5° WLCA12-LE-N WLCL-LE-N WLCAL4-LE-N WLCAL5-LE-N 25±5° WLCA12-2LE-N WLCL-2LE-N ----- ----- MAX20° WLCA12-2NLE-N WLCL-2NLE-N ----- ----- High-sensitivity 10° WLG12-LE-N WLGL-LE-N ----- ----- LED Basic 15±5° WLCA12-LD-N WLCL-LD-N WLCAL4-LD-N WLCAL5-LD-N 25±5° WLCA12-2LD-N WLCL-2LD-N ----- ----- MAX20° WLCA12-2NLD-N WLCL-2NLD-N ----- ----- High-sensitivity 10° WLG12-LD-N WLGL-LD-N ----- ----- Actuator Fork lever lock Fork lever lock Fork lever lock Indicator Item Movement until the lever reverses Model Model Model Neon lamp Basic 50±5° WLCA32-41LE-N WLCA32-42LE-N WLCA32-43LE-N LED Basic 50±5° WLCA32-41LD-N ----- WLCA32-43LD-N Actuator Sealed top plunger Sealed top-roller plunger Sealed top-ball plunger Indicator Item Pretravel (PT) Model Model Model Neon lamp Basic 1.7 mm WLD18-LE-N WLD28-LE-N WLD38-LE-N LED Basic 1.7 mm WLD18-LD-N WLD28-LD-N WLD38-LD-N Actuator Horizontal plunger Horizontal-roller plunger Horizontal-ball plunger Indicator Item Pretravel (PT) Model Model Model Neon lamp Basic 2.8 mm WLSD-LE-N WLSD2-LE-N WLSD3-LE-N LED Basic 2.8 mm WLSD-LD-N WLSD2-LD-N WLSD3-LD-N Actuator Coil spring (spring diameter: 6.5) Coil spring (spring diameter: 4.8) Indicator Item Pretravel (PT) Model Model Neon lamp Basic 20±10 mm WLNJ-LE-N WLNJ-30LE-N LED Basic 20±10 mm WLNJ-LD-N WLNJ-30LD-N Actuator Resin rod (rod diameter: 8) Steel wire (wire diameter: 1) Indicator Item Pretravel (PT) Model Model Neon lamp Basic 40±20 mm WLNJ-2LE-N WLNJ-S2LE-N LED Basic 40±20 mm WLNJ-2LD-N WLNJ-S2LD-N Operation Indicator Switches +2° -1° +2° +2° -1° +2° +2° -1° +2° -1°

Switches with Direct-wired Connectors Switches with Pre-wired Connectors Note: The standard cable length for a pre-wired connector is 0.3 m. Contact your OMRON representative for information on other cable lengths. General-purpose Switches Actuator Roller lever: R38 Item Basic High-sensitivity High-precision Connector shape Built-in switch type Voltage Wiring locations Connector pin No. Model Model Model Threaded (M12) General-purpose AC NO only NO WLCA2-LDK13A-N ----- ----- NC + NO NC NO WLCA2-LDK43A-N ----- ----- DC NO only NO WLCA2-LDK13-N WLG2-LDK13-N WLGCA2-LDK13-N NC + NO NC NO WLCA2-LDK43-N WLG2-LDK43-N WLGCA2-LDK43-N Airtight AC NO only NO WLCA2-55LDK13-N WLG2-55LDK13-N WLGCA2-55LDK13-N NC + NO NC NO WLCA2-55LDK43-N WLG2-55LDK43-N WLGCA2-55LDK43-N Actuator Roller lever R38 Item Basic High-sensitivity High-precision Connector shape Built-in switch type Voltage Wiring locations Connector pin No. Model Model Model Threaded (M12) General-purpose DC NO only NO WLCA2-LD-M1J-N WLG2-LD-M1J-N WLGCA2-LD-M1J-N NO WLCA2-LD-M1GJ-N WLG2-LD-M1GJ-N WLGCA2-LD-M1GJ-N NC only NC WLCA2-LD-M1JB-N WLG2-LD-M1JB-N ----- NC + NO NC NO WLCA2-LD-DGJ-N WLG2-LD-DGJ-N WLGCA2-LD-DGJ-N NO only NO NC WLCA2-LD-DK1EJ-N WLG2-LD-DK1EJ-N -----Airtight NO only NO WLCA2-55LD-M1J-N ----- WLGCA2-55LD-M1J-N NO WLCA2-55LD-M1GJ-N WLG2-55LD-M1GJ-N WLGCA2-55LD-M1GJ-N NC only NC WLCA2-55LD-M1JB-N WLG2-55LD-M1JB-N WLGCA2-55LD-M1JB-N NC + NO NC NO WLCA2-55LD-DGJ-N WLG2-55LD-DGJ-N WLGCA2-55LD-DGJ-N NO only NO NC WLCA2-55LD-DK1EJ-N WLG2-55LD-DK1EJ-N ----- Smartclick General-purpose NO only NO ----- WLG2-LD-M1TJ-N ----- NO only NC ----- WLG2-LD-M1TJB-N ----- Sensor I/O Connector Switches 3 4 1 2 3 4 3 4 1 2 3 4 3 4 1 2 3 4 3 4 1 4 2 3 1 2 3 4 4 3 3 4 1 4 2 3 1 2 3 4 4 3 3 4 2 3

Screw Terminal Switches Screw Terminal Switches Indicator-equipped (Light-ON when Not Operating) Switches *1 Direct-wired Connectors/Pre-wired Connectors Indicator-equipped (Light-ON when Not Operating) Switches *1 Note: Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. *1. Light-ON when not operating means the indicator is lit when the actuator is free and is not light when the Switch contacts (NO) close when the actuator rotates or is pushed down. *2. The position of the positioning piece is not always the same. If using an L-shaped connector causes problems in application, use a straight connector. Connecting Sensor I/O connector cable (Socket) 13 (NO) 11 (NC) 14 (NO) 12 (NC) Za 13 (NO) 11 (NC) 14 (NO) 12 (NC) Internal circuits Za NONCNCNO Internal circuits WL@-@K13A-N WL@-@K43A-N WL@-@-AGJ-N 1 1 33 2 3 4 2 3 NONCNCNO Internal circuits 4 1 3 2 WL@-@K13-N WL@-@-M1J-N WL@-@-M1TJ-N WL@-@-M1GJ-N WL@-@-M1TGJ-N WL@-@-M1JB-N WL@-@-M1TJB-N WL@-@K43-N WL@-@DGJ-N WL@-@DTGJ-N 1 2 3 AC DC AC DC Za Za indicate the connector pin number. 1 2 3 4 indicate the connector pin number. Positioning piece *2 Connector Pin Layout Diagram Positioning piece *2 Type AC/DC Type Number of cable cores Cable length L (m) Model Applicable limit switch models M12 Screw (Straight) AC 2 2 m XS2F-A421-DB0-F WL@-@K13A-N5 m XS2F-A421-GB0-F 4 2 m XS2F-A421-D90-F WL@-@K43A-N WL@-@-AGJ-N5 m XS2F-A421-G90-F DC 2 m XS2F-D421-DD0 WL@-@K13-N WL@-@-M1J-N5 m XS2F-D421-GD0 2 m XS2F-D421-DA0-F WL@-@-M1GJ@-N5 m XS2F-D421-GA0-F 2 m XS2F-D421-D80-F WL@-@K43-N WL@-@-M1JB-N WL@-@DGJ-N5 m XS2F-D421-G80-F M12 Smart click type (Straight) DC 4 2 m XS5F-D421-D80-F WL@-@-M1TJ-N WL@-@-M1TJB-N 5 m XS5F-D421-G80-F

Dimensions (Unit: mm) XS2F-@421-@@0-@ XS2F-D421-@D0 Wiring Diagram XS5F-D421-@80-F AC/DC Type Two-core model Four-core model Model Wiring Diagram Model Wiring Diagram AC XS2F-A421-DB0-F XS2F-A421-GB0-F XS2F-A421-D90-F XS2F-A421-G90-F DC XS2F-D421-DD0 XS2F-D421-GD0 XS2F-D421-D80-F XS2F-D421-G80-F XS2F-D421-DA0-F XS2F-D421-GA0-F 6 dia. 30 5 40.7 L (Cable length) DC AC 14.9 dia. Brown Blue Terminal No. Cable color of core sheath Blue Black Brown White Terminal No. Cable color of core sheath1 Blue Brown Terminal No. Cable color of core sheath Brown Blue Terminal No. Cable color of core sheath Wiring Diagram AC/DC Type Four-core model Model Wiring Diagram DC XS5F-D421-D80-F XS5F-D421-G80-F Blue Black Brown White Terminal No. Cable color of core sheath 6 dia.40.7 L (Cable length) 14.9 dia.

Note: The maximum cable length for a Hermetic Switch is 5 m. Note: The maximum cable length for a Hermetic Switch is 5 m. Environment-resistant Switches Actuator Roller lever R38 Adjustable roller lever Adjustable rod lever 25 to 140mm Item Pretravel (PT) Model Model Model Airtight seal Basic 15±5° WLCA2-55-N WLCA12-55-N WLCL-55-N MAX20° WLCA2-2N55-N ----- ----- High-sensitivity 10° WLG2-55-N ----- ----- High-precision 5° WLGCA2-55-N ----- ----- Hermetic seal Molded terminals, -139 models Basic 15±5° WLCA2-139-N WLCA12-139-N WLCL-139-N MAX20° WLCA2-2N139-N ----- ----- High-sensitivity 10° WLG2-139-N ----- ----- High-precision 5° WLGCA2-139-N ----- ----- Molded terminals, -140 models Basic 15±5° WLCA2-140-N WLCA12-140-N WLCL-140-N MAX20° WLCA2-2N140-N ----- ----- High-sensitivity 10° WLG2-140-N ----- ----- High-precision 5° ----- ----- ----- Molded terminals, -141 models Basic 15±5° WLCA2-141-N WLCA12-141-N ----- High-sensitivity 10° WLG2-141-N ----- ----- High-precision 5° WLGCA2-141-N ----- ----- Anti-coolant Basic 15±5° WLCA2-RP60-N WLCA12-RP60-N WLCL-RP60-N High-sensitivity 10° WLG2-RP60-N ----- ----- High-precision 5° WLGCA2-RP60-N ----- ----- Heat-resistant Basic 15±5° WLCA2-TH-N WLCA12-TH-N WLCL-TH-N 25±5° WLCA2-2TH-N WLCA12-2TH-N WLCL-2TH-N MAX20° WLCA2-2NTH-N WLCA12-2NTH-N WLCL-2NTH-N High-sensitivity 10° WLG2-TH-N WLG12-TH-N WLGL-TH-N High-precision 5° WLGCA2-TH-N ----- ----- Low-temperature Basic 15±5° WLCA2-TC-N WLCA12-TC-N WLCL-TC-N 25±5° WLCA2-2TC-N WLCA12-2TC-N WLCL-2TC-N MAX20° WLCA2-2NTC-N WLCA12-2NTC-N WLCL-2NTC-N High-sensitivity 10° WLG2-TC-N WLG12-TC-N WLGL-TC-N High-precision 5° WLGCA2-TC-N ----- ----- Corrosion-proof Basic 15±5° WLCA2-RP-N WLCA12-RP-N WLCL-RP-N High-sensitivity 10° WLG2-RP-N ----- ----- High-precision 5° WLGCA2-RP-N ----- ----- Weather-proof Basic 15±5° WLCA2-P1-N WLCA12-P1-N WLCL-P1-N 25±5° ----- ----- MAX20° ----- ----- High-sensitivity 10° WLG2-P1-N WLG12-P1-N WLGL-P1-N Actuator Sealed top-roller plunger Horizontal plunger Horizontal-roller plunger Coil spring (spring diameter: 6.5) Resin rod (rod diameter: 8) Model Model Model Model Model Airtight WLD28-55-N WLSD-55-N WLSD2-55-N WLNJ-55-N WLNJ-255-N Hermetic Molded terminals, -139 models WLD28-139-N WLSD-139-N WLSD2-139-N WLNJ-139-N WLNJ-2139-N Molded terminals, -140 models WLD28-140-N ----- WLSD2-140-N WLNJ-140-N WLNJ-2140-N Anti-coolant WLD28-RP60-N WLSD-RP60-N WLSD2-RP60-N WLNJ-RP60-N WLNJ-2RP60-N Heat-resistant WLD28-TH-N WLSD-TH-N WLSD2-TH-N WLNJ-TH-N ----- Low-temperature ----- WLSD-TC-N WLSD2-TC-N WLNJ-TC-N ----- Corrosion-proof WLD28-RP-N WLSD-RP-N WLSD2-RP-N WLNJ-RP-N WLNJ-2RP-N Standard Switches +2° -1° +2° +2° -1° +2° +2° -1° +2° +2° -1° +2° +2° -1° +2° +2° -1° +2° +2° -1° +2° +2° -1° +2° +2° -1°

Note: The maximum cable length for a Hermetic Switch is 5 m. Environment-resistant Switches Actuator Roller lever: R38 Adjustable roller lever Adjustable rod lever: 25 to 140mm Indicator Item Pretravel (PT) Model Model Model Neon lamp Basic 15±5° WLCA2-55LE-N WLCA12-55LE-N ----- MAX20° WLCA2-2N55LE-N ----- ----- High-sensitivity 10° WLG2-55LE-N ----- ----- High-precision 5° WLGCA2-55LE-N ----- ----- LED Basic 15±5° WLCA2-55LD-N WLCA12-55LD-N WLCL-55LD-N MAX20° WLCA2-2N55LD-N ----- ----- High-sensitivity 10° WLG2-55LD-N ----- ----- High-precision 5° WLGCA2-55LD-N ----- ----- Actuator Sealed top-roller plunger Horizontal plunger Horizontal-roller plunger Coil spring (spring diameter: 6.5) Resin rod (rod diameter: 8) Indicator Item Model Model Model Model Model Neon lamp Basic WLD28-55LE-N ----- ----- ----- ----- LED Basic WLD28-55LD-N WLSD-55LD-N WLSD2-55LD-N WLNJ-55LD-N WLNJ-255LD-N Actuator Roller lever: R38 Wiring specification NC wiring NO wiring Item Pretravel (PT) Model Model Molded terminals, -139 models Basic 15±5° WLCA2-139LD2-N WLCA2-139LD3-N 25±5° WLCA2-2139LD2-N WLCA2-2139LD3-N MAX20° ----- ----- High-sensitivity 10° ----- WLG2-139LD3-N High-precision 5° WLGCA2-139LD2-N WLGCA2-139LD3-N Molded terminals, -141 models Basic 15±5° WLCA2-141LD2-N WLCA2-141LD3-N 25±5° ----- ----- MAX20° ----- ----- High-sensitivity 10° WLG2-141LD2-N WLG2-141LD3-N High-precision 5° ----- ----- Anti-coolant Basic 15±5° WLCA2-RP60LD2-N WLCA2-RP60LD3-N 25±5° WLCA2-2RP60LD2-N WLCA2-2RP60LD3-N MAX20° ----- ----- High-sensitivity 10° WLG2-RP60LD2-N WLG2-RP60LD3-N High-precision 5° WLGCA2-RP60LD2-N WLGCA2-RP60LD3-N Operation indicator Switches +2° -1° +2° +2° -1° +2° +2° -1° +2° +2° -1° +2° +2° -1° +2°

*1. The default setting is light-ON when not operating (NO wiring). Turn the lamp holder by 180° to change the setting to light-ON when operating (NC wiring). (Ask your OMRON representative for information on 2-conductor models.) *2. With 0.3-m cable. Spatter-prevention Switches Actuator Roller lever: R38 Sealed top-roller plunger Double Nut Lever Allen-head Lever Indicator Item Pretravel (PT) Model Model Model Neon lamp Basic 15±5° WLCA2-LEAS-N WLCA2-LES-N WLD28-LES-N High-sensitivity 10° WLG2-LEAS-N WLG2-LES-N ----- High-precision 5° ----- WLGCA2-LES-N ----- LED Basic 15±5° WLCA2-LDAS-N WLCA2-LDS-N WLD28-LDS-N High-sensitivity 10° WLG2-LDAS-N WLG2-LDS-N ----- High-precision 5° ----- WLGCA2-LDS-N ----- Long-life Switches Item Operation indicator (LED) *1 Basic 15±5° High-sensitivity 10° High-precision 5° Actuator Model Model Model WLMCA2-LD-N WLMG2-LD-N WLMGCA2-LD-N 2 conductors AC WLMCA2-LDK13A-N WLMG2-LDK13A-N WLMGCA2-LDK13A-N DC WLMCA2-LDK13-N WLMG2-LDK13-N WLMGCA2-LDK13-N 4 conductors AC WLMCA2-LDK43A-N WLMG2-LDK43A-N ----- DC WLMCA2-LDK43-N WLMG2-LDK43-N WLMGCA2-LDK43-N 2 conductors DC WLMCA2-LD-M1J-N WLMG2-LD-M1J-N WLMGCA2-LD-M1J-N 4 conductors DC WLMCA2-LD-DGJ-N WLMG2-LD-DGJ-N ----- +2° -1° +2° +2° -1° +2° +2° -1° +2° Roller lever: R38, screw terminals Roller lever, direct-wired connector Roller lever, pre-wired connector

Switches without Levers, Heads, and Actuators General-purpose Parts *1. The heads are not compatible with WL-series Switches. *2. The same Actuators can be used for both WL and WL-N Switches. Spatter-prevention Parts *1. The heads are not compatible with WL-series Switches. *2. The same Actuators can be used for both WL and WL-N Switches. Covers with Indicators (See Note.) General-purpose Parts * The Covers are not compatible with WL-series Switches. Spatter-prevention Parts Note: The default setting is for light-ON when not operating. Turn the lamp holder by 180° to change the setting to light-ON when operating. Actuator Item Pretravel (PT) Set Switch without levers Head *1 (with Actuators) Actuator only *2 Model Model Model Roller lever Basic 15±5° WLCA2-N WLRCA2-N WL-1H1100-N WL-1A100 25±5° WLCA2-2-N WLRCA2-2-N WL-3H1100-N MAX20° WLCA2-2N-N WLRCA2-2N-N WL-1H1100-N High-sensitivity 10° WLG2-N WLRG2-N WL-2H1100-N Adjustable roller lever Basic 15±5° WLCA12-N WLRCA2-N WL-1H2100-N WL-2A100 25±5° WLCA12-2-N WLRCA2-2-N WL-3H2100-N MAX20° WLCA12-2N-N WLRCA2-2N-N WL-1H2100-N High-sensitivity 10° WLG12-N WLRG2-N WL-2H2100-N Variable rod lever Basic 15±5° WLCL-N WLRCA2-N WL-1H4100-N WL-4A100 25±5° WLCL-2-N WLRCA2-2-N WL-3H4100-N MAX20° WLCL-2N-N WLRCA2-2N-N WL-1H4100-N High-sensitivity 10° WLGL-N WLRG2-N WL-2H4100-N Fork lever lock Basic MAX55° WLCA32-41-N WLRCA32-N WL-5H5100-N WL-5A100 WLCA32-42-N WL-5H5102-N WL-5A102 WLCA32-43-N WL-5H5104-N WL-5A104 WLCA32-44-N WL-5H5104-N WL-5A104 Top plunger Basic MAX 1.7 mm WLD18-N ----- WL-7H100-N ----- WLD28-N WL-7H400-N ----- WLD38-N WL-7H300-N ----- Horizontal plunger Basic MAX 2.8 mm WLSD-N ----- WL-8H100-N ----- WLSD2-N WL-8H200-N ----- WLSD3-N WL-8H300-N ----- Flexible rod Basic 20±10 mm WLNJ-N ----- WL-9H100-N ----- WLNJ-30-N WL-9H200-N ----- 40±20 mm WLNJ-2-N WL-9H300-N ----- WLNJ-S2-N WL-9H400-N ----- Actuator Lever Type Item Set Switch without levers Head *1 (with Actuators) Actuator only *2 Model Model Model Roller lever Allen-head bolt lever Basic WLCA2-LES-N WLRCA2-LES-N WL-1H1100S-N WL-1A103SWLCA2-LDS-N WLRCA2-LDS-N High-sensitivity WLG2-LDS-N WLRG2-LDS-N Double nut lever Basic WLCA2-LEAS-N WLRCA2-LES-N WL-2H1100S-N WL-1A105SWLCA2-LDAS-N WLRCA2-LDS-N High-sensitivity WLG2-LDAS-N WLRG2-LDS-N +2° -1° +2° -1° +2° -1° Cover Cover only * Item Model Neon lamp WL-LE-N LED WL-LD-N Cover Cover only * Item Model Neon lamp WL-LES-N LED WL-LDS-N

Note: 1. The above figures are for steady-state currents. 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current. 5. For PC loads, use the microload models. * For high-sensitivity switches. Operation indicator Switches Characteristics Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the highsensitivity switches models. *1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. High-sensitivity Switches and Switches with Flexible Rod Actuators: 10 million operations min. 500,000 operations min. for weather-proof models. *3. Durability is 500,000 operations min. for high-sensitivity models. 500,000 operations min. for weather-proof models. Contact your OMRON representative for information on Environment-resistant Switches. *4. Switches with Connectors: 1,500 V. *5. Except Switches with Flexible Rod Actuators. *6. For low-temperature models this is -40°C to +40°C (with no icing). For heatresistant models the range is +5°C to +120°C. General-purpose/ Environment-resistant Switches Item Rated voltage (V) Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO Basic or high-precision AC 125 250 500 1.5 1.5 0.8 1.5 2.5 1.5 0.8 DC 8 125 250 0.8 0.4 0.2 0.1 0.2 0.1 0.8 0.4 0.2 0.1 High-sensitivity Switches AC 125 250 5 ---- ---- ---- DC 125 250 0.4 0.2 ---- ---- ---- Inrush current NC 30 A max.(15 A max. *) NO 20 A max.(10 A max. *) Minimum applicable load 5 VDC 1 mA, resistive load, P level Model Item Max. rated voltage Leakage current (mA) WL-LE-N Neon lamp 125 AC Approx. 0.6 250 AC Approx. 1.9 WL-LD-N LED 10 to 24 VAC/DC Approx. 0.4 115 VAC/DC Approx. 0.5 Degree of protection IP67 Durability *1 Mechanical 15,000,000 operations min. *2 Electrical 750,000 operations min. *3 Operating speed 1 mm/s to 1 m/s (in case of WLCA2-N) Operating frequency Mechanical 120 operations/minute min. Electrical 30 operations/minute min. Rated frequency 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 25 mΩ max. (initial value for the built-in switch when tested alone) Dielectric strength Between terminals of the same polarity 1,000 VAC (600 VAC), 50/60 Hz for 1 min Between currentcarrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude *5 Shock resistance Destruction 1,000 m/s2 max. Malfunction 300 m/s2 *5 Ambient operating temperature -10 to +80°C (with no icing) *6 Ambient operating humidity 35% to 95% RH Weight Approx. 255 g (in case of WLCA2-N)

Note: 1. The above figures are for steady-state currents. 3. A lamp load has an inrush current of 10 times the steady-state current. 4. A motor load has an inrush current of 6 times the steady-state current. * Refer to the rating of a General-purpose / Weather-proof Switches type for the rating of a high-sensitivity overtravel type. * For high-sensitivity switches. Characteristics Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are those for the highsensitivity overtravel models. *1. The values are calculated at an operating temperature of +5°C to +35°C and an operating humidity of 40% to 70% RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Durability is 10,000,000 operations min. for high-sensitivity models. *3. Durability is 500,000 operations min. for high-sensitivity models. 500,000 operations min. for weather-proof models. Contact your OMRON representative for information on Airtight Switches. *4. Switches with Connectors: 1,500 V. Spatter-prevention Switches Item Rated voltage (V) Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO WL@-LES-N (Without high-sensitivity overtravel models) AC 125 250 1.5 2.5 1.5 WL@-LDS-N (Without high-sensitivity overtravel models) AC 115 10 3 1.5 10 5 2.5 DC 12 115 0.8 0.2 0.2 0.8 0.2 Inrush current NC 30 A max.(15 A max. *) NO 20 A max.(10 A max. *) Minimum applicable load 5 VDC 1 mA, resistive load, P level Degree of protection IP67 Durability *1 Mechanical 15,000,000 operations min. *2 Electrical 750,000 operations min. (3 A at 250 VAC, resistive load) *3 Operating speed 1 mm/s to 1 m/s (in case of WLCA2-LDS-N) Operating frequency Mechanical 120 operations/minute min. Electrical 30 operations/minute min. Rated frequency 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 25 mΩ max. (initial value for the built-in switch when tested alone) Dielectric strength Between terminals of the same polarity 1,000 VAC (600 VAC), 50/60 Hz for 1 min Between currentcarrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Between each terminal and non-currentcarrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min *4 Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction 1,000 m/s2 max. Malfunction 300 m/s2 Ambient operating temperature -10 to +80°C (with no icing) Ambient operating humidity 35% to 95% RH Weight Approx. 255 g (in case of WLCA2-LDS-N)

  • For high-sensitivity overtravel models. Direct-wired Connector and Pre-wired Connector Switches Note: 1. The above figures are for steady-state currents. 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). 3. A lamp load has an inrush current of 10 times the steady- state current. 4. A motor load has an inrush current of 6 times the steady- state current. Characteristics Note: 1. The above figures are initial values. 2. The figures in parentheses for dielectric strength are for the High-sensitivity Switches. *1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. *2. Switches with Connectors: 1,500 V. Long-life Switches Item Rated voltage (V) Non-inductive load (A) Inductive load (A) Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO Basic or high-precision 115 AC 10 3 1.5 10 5 2.5 12 DC 24 DC 115 DC 0.8 0.2 0.2 0.8 0.2 High-sensitivity

115 AC 5———

115 DC 0.4 — — — Inrush current NC 30 A max. (15 A max. *) NO 20 A max. (10 A max. *) Minimum applicable load 5 VDC 1 mA, resistive load, P level Rated voltage (V) Non-inductive load (A) Inductive load (A) Model Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO Basic or high-precision 115 AC 33 1 . 5 33 2 . 5 12 DC 24 DC 115 DC 0.8 0.2 0.8 0.2 High-sensitivity

115 AC 3———

115 DC 0.4 — — — Degree of protection IP67 Durability *1 Mechanical 30,000,000 operations min. Electrical 30,000,000 operations min. (10 mA at 24 VDC, resistive load) 750,000 operations min. (3 A at 115 VAC, resistive load) High-sensitivity Switches: 500,000 opera- tions min. (3 A at 115 VAC, resistive load) Operating speed 1 mm/s to 1 m/s (for WLMCA2-LD-N) Operating frequency Mechanical 120 operations/minute Electrical 30 operations/minute Rated frequency 50/60 Hz Insulation resistance 100 MΩ min. (at 500 VDC) Contact resistance 25 mΩ max. (initial value for the built-in switch when tested alone) Dielectric strength (50/

60 Hz for 1

min) Between ter- minals of the same polarity 1,000 VAC (600 VAC), 50/60 Hz for 1 min Between cur- rent-carrying metal part and ground 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min Between each terminal and non-cur- rent-carrying metal part 2,200 VAC (1,500 VAC), 50/60 Hz for 1 min Vibration re- sistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude Shock resis- tance Destruction 1,000 m/s2 max. Malfunction 300 m/s2 max. Ambient operating tempera- ture –10°C to +80°C (with no icing) Ambient operating humidity 35% to 95%RH Weight Approx. 255 g (for WLMCA2-LD-N)

UL/cUL (UL508, CSA C22.2 No.14) A600 Authentication conditions B600 Authentication conditions C300 Authentication conditions A300 Authentication conditions General-purpose/ Environment-resistant/ Spatter-prevention Switches Agency Standard File No. Approved models UL UL508 Contact your OMRON representative for information Contact your OMRON representative for information CSA C22.2 No.14 TÜV Rheinland EN60947-5-1 CCC (CQC) GB14048.5 Specifications Approved Standards Indicator Sensor I/O connectors Item No indicator No Connector Basic Switches A600

1 A, 125 VDC

High-sensitivity or high-precision B600

0.5 A, 125 VDC

Pre-wired Connector (AC) Basic, hi gh-sensitivity, or high-precision C300

3 A, 250 VAC

Pre-wired Connector (DC) Direct-wired Connector (DC) Basic Switches 1 A, 125 VDC High-sensitivity or high-precision 0.5 A, 125 VDC Neon lamp No Connector Basic Switches A300

10 A, 250 VAC

High-sensitivity or high-precision B300

5 A, 250 VAC

Pre-wired Connector (AC) Basic, hi gh-sensitivity, or high-precision C300

10 A, 115 VAC

1 A, 115 VDC

High-sensitivity or high-precision B150

5 A, 115 VAC

0.5 A, 115 VDC

Pre-wired Connector (AC) Basic, hi gh-sensitivity, or high-precision C150

3 A, 115 VAC

Pre-wired Connector (DC) Direct-wired Connector (DC) Basic Switches 1 A, 115 VDC High-sensitivity or high-precision 0.5 A, 115 VDC Rated voltage Energizing current Current (A) Volt-ampere (VA) Make Break Make Break

120 VAC

240 VAC

480 VAC

600 VAC

1.5 1.2 7,200 720 Rated voltage Energizing current Current (A) Volt-ampere (VA) Make Break Make Break 7.5 1.5 0.75 0.6 3,600 360 Rated voltage Energizing current Current (A) Volt-ampere (VA) Make Break Make Break

2.5 A 15

7.5 1.5 0.75 1,800 180 Rated voltage Energizing current Current (A) Volt-ampere (VA) Make Break Make Break

240 VAC 10 A 60

3 7,200 720

B300 Authentication conditions A150 Authentication conditions B150 Authentication conditions C150 Authentication conditions TÜV (EN 60947-5-1) (Certification Only for Switches with Ground Terminals and DC Switches with Connectors) CCC (GB14048.5) Rated voltage Energizing current Current (A) Volt-ampere (VA) Make Break Make Break

240 VAC 5 A 30

1.5 3,600 360 Rated voltage Energizing current Current (A) Volt-ampere (VA) Make Break Make Break

120 VAC 10 A 60 6 7,200 720

Rated voltage Energizing current Current (A) Volt-ampere (VA) Make Break Make Break

120 VAC 5 A 30 3 3,600 360

Rated voltage Energizing current Current (A) Volt-ampere (VA) Make Break Make Break 120 VAC 2.5 A 15 1.5 1,800 180 Authentication conditions Specification With ground terminals With DC Connector No indicator Neon lamp LED Working load category AC-15 DC-12 AC-15 AC-15 DC-12 DC-12 Rated working voltage (Ue) 250 V 48 V 250 V 115 V 48 V 48 V Rated working current (Ie) 2 A Conditional short-circuit current 100 A Short-circuit protective device (SCPD) 10 A, fuse type gG Rated insulation voltage (Ui) 250 V 48 V Rated impulse dielectric strength (Uimp) 4 kV 800 V Pollution degree 3 Electric shock protection class Class I Class III Authentication conditions Specification No indicator Neon lamp LED With DC Connector With AC Connector Working load category AC-15 DC-13 AC-15 AC-15 DC-13 DC-13 AC-15 Rated working voltage (Ue) 250 V 48 V 250 V 250 V 48 V 48 V 250 V Rated working current (Ie) 2 A Conditional short-circuit current 1000 A Short-circuit protective device (SCPD) 10 A, fuse type gG Rated insulation voltage (Ui) 250 V

Structure and Nomenclature Structure *1. The available conduit screws are Pg 13.5, M20 and 1/2-14 NPT. General-purpose Switches: WLCA2-N Roller Lever Bolt Set Position Marker Plate Set the indicator needle so that it is between protrusions on the bearing section on the marker plate after operation. Cover Setscrew A combination Philips-slotted screw is used. A retainer prevents the screw from falling from the cover even when the screw is loose. Cover Cover Seal High sealing performance is achieved. The seal also serves as a spacer. There is no troublesome insulating paper, making it easy to work with the Switch. Head-mounting Screws Head You can remove the two screws to mount the switch in any of the four possible orientations. Shaft Section Seal An oil seal is fitted on the inlet of the shaft section to maintain a tight seal. You can change the direction of the operational plunger to electrically switch the direction of operation between both sides, left only, or right only. Operational Plunger Built-in Switch Built-in switch with SPST -NO+NC contact form. Terminal Screws Four, M3.5 screws Conduit Opening *1 The conduit screw is a parallel screw for G1/2 piping, and is used together with an SC connector to maintain a tight seal. Roller Actuator The roller is made of self-lubricating sintered stainless steel and boasts high resistance to wear. Lever The lever is forged from corrosion-resistant aluminum alloy. It provides superior corrosion resistance and outstanding strength. With roller lever, adjustable rod and flexible rod models, the actuator position can be set anywhere within 360°. (The lever cannot be mounted in the opposite direction.) Requires maintenance (excessive overtravel) Requires maintenance (excessive overtravel) Requires maintenance (insufficient overtravel) Proper range Proper range Set position marker plate Head

Note: 1. Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. *1. Light-ON when operating means that the lamp lights when the Limit Switch contacts (NC) release, or when the actuator rotates or is pushed down. *2. Light-ON when not operating means the lamp remains lit when the actuator is free, or when the Limit Switch contacts (NO) close when the actuator rotates or is pushed down. Indicators Indicator The indicator is either a neon lamp or an LED. Switches with LED indicators have a built-in rectifier stack, so there is no connection polarity. Contact Spring Use the terminal screws on the built-in switch to connect to the lamp terminals. A coil spring is used to make contact, so connecting to the lamp terminals is not necessary. Indicator Covers The indicator covered if outsert molded from diecast aluminum and has outstanding sealing properties. Indicator Windows Operating status (i.e., light-ON when operating or light-ON when not operating) depends on whether a neon lamp or an LED is used. Indicators can be switched from light-ON when operating and light-ON when not operating, by simply rotating the indicator holder by 180°. Light-ON when Operating/Not Operating Lamp Holder LED at top LED at bottom Light-ON when Operating Light-ON when Not Operating Operation WL-LE-N WL-LD-N Light-ON when operating *1 Light-ON when not operating *2 Power Built-in switch Internal circuits Load 13Za Power Built-in switch Internal circuits Load13 Za Internal Circuits WL-LE-N WL-LD-N Contact spring Neon lamp Resistor Contact spring Rectifier stack Rated current diode LED Zener diode Resistor Resistor Light-ON when Not Operating

Environment-resistant Switches Molding Specifications for Hermetic Switches WL@-139-N WL@-140-N WL@-141-N WL@-145-N WL@-RP40-N WL@-RP60-N : Molded parts Standard built-in switch Airtight built-in switch Airtight built-in switch Airtight built-in switch Airtight built-in switch Airtight built-in switch * Fluorine rubber is used for all rubber parts. Oil sealHead cap Oil sealHead cap * The connector can be removed, so it is possible to use flexible conduit for the cable. Model Cable specifications Connector type WL@-139-N Standard 5-m VCT cable, with high flexibility and good anti-oil properties attached. Finished outer diameter: 11.5 mm, 4 conductors. Resin cap WL@-140-N WL@-141-N WL@-145-N Metal connector WL@-RP40-N Resin connector * WL@-RP60-N Resin cap

Spatter-prevention Switches: WLCA2-LES-N Screws Externally visible screws on the head and cover are made of stainless steel to prevent spatter adherence. Using stainless steel prevents spatter from adhering. Roller Lever Bolt Stainless steel construction to prevent spatter adherence. Double nut models are also available. Head Cap Using fluororesin prevents spatter from adhering. * Spatter means the zinc powder produced when welding. Adhering spatter to the Limit Switch may cause malfunction of lever or lamp cover. The lack of gap prevents spatter powder from clogging. Roller, Roller Axis A baking finish is applied to the surface so that any adhering spatter is easily removed. Operating Lever Actuator

A combination Philips-slotted screw is used. A retainer prevents the screw from falling from the cover even when the screw is loose. Head Cap The head cap helps prevent the entry of cutting chips.Y ou can use the protrusion on the cap to confirm the set position. PEEK resin is used. It provides superior resistance to wear. Y ou can change the mounting direction to use any one of the three operating directions (both sides, left side, or right side). Operating Plunger High sealing performance is achieved. The seal also serves as a spacer. There is no troublesome insulating paper, making it easy to work with the Switch. Cover Seal Built-in Switch Built-in switch with an SPST -NO+NC contact form. Terminal Screws Four, M3.5 screws. Conduit Opening In addition to parallel threads for G1/2 tubing, direct-wired and pre-wired connectors have been added to the series. Cover Setscrew Head You can remove the two screws to mount the head in any of the four possible directions. A head cap and oil seal form a double-seal structure. Excellent durability and reliability are ensured. Actuator The roller is made of self-lubricating sintered stainless steel. It provides superior resistance to wear. Lever Roller The lever is forged from anti-corrosive aluminum alloy. It provides superior corrosion resistance and outstanding strength. With a roller lever actuator, the actuator position can be set anywhere within 360°. (The lever cannot be mounted in the opposite direction.) Cover Oil seal Head cap

Dimensions and Operating Characteristics (Unit: mm) Switches with Roller Lever Actuators Basic, High-sensitivity, and High-precision Switches Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. *1. The operating characteristics for WLCA12-N, WLCA12-2-N, WLCA12-2N-N, and WLG12-N are measured at the lever length of 38 mm. General-purpose Switches Model Operating characteristics WLCA2-N WLCA2-2-N WLCA2-2N-N WLG2-N WLCA2-7-N WLCA2-8-N WLGCA2-N Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 25±5° 60° 16° 13.34 N 1.18 N 20° max. 70° 10° 13.34 N 1.18 N 10° 80° 10.2 N 0.9 N 15±5° 70° 12° 8.04 N 0.71 N 15±5° 70° 12° 13.34 N 1.18 N 80° Model Operating characteristics WLCA12-N *1 WLCA12-2-N *1 WLG12-2N-N *1 WLG12-N *1 Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 25±5° 60° 16° 13.34 N 1.18 N 20° max. 70° 10° 13.34 N 1.18 N 10° 80° Standard Switches Allen-head bolt JIS B 0202 G½ 17.5×7 dia. * (125) (4.9) (15.1) 40±0.7 30.2±0.2 58.7±0.2 14.7 R38 Four, 5.2 dia. holes Two, M3.5 Three, M4 * Stainless sintered roller 60 max. 12.7 40±1.5 41.5±1.5 53±1.5 68.7 21.6 53.2±0.8 42 max. 29.2±1.2 Four, M6 Depth: 15 min. 25.4 25.4 13.1 Roller lever R38 Basic WLCA2-N WLCA2-2-N WLCA2-2N-N The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. High-sensitivity WLG2-N High-precision WLGCA2-N 17.5×15 dia. * (137) (4.9) (15.1) 40±0.7 30.2±0.2 58.7±0.2 14.7 R50 Two, M3.5 Three, M4 Four, 5.2 dia. holes * Stainless sintered roller 67.2 max. 12.7 41.5±1.5 58.1±1.5 Allen-head bolt JIS B 0202 G½ 68.7 21.6 53.2±0.8 42 max. 29.2±1.2 Four, M6 Depth: 15 min 25.4 25.4 13.1 36±1.5 Roller lever R50 Basic WLCA2-7-N Allen-head bolt 17.5×7 dia. * (150) (4.9) (15.1) 40±0.7 30.2±0.2 58.7±0.2 14.7 R63 Two, M3.5 Three, M4 JIS B 0202 G½ Four, 5.2 dia. holes * Stainless sintered roller 60 max. 12.7 41.5±1.5 40±1.5 53±1.5 68.7 21.6 53.2±0.8 42 max. 29.2±1.2 Four, M6 Depth: 15 min 25.4 25.4 13.1 Roller lever R63 Basic WLCA2-8-N 17.5×7 dia. * (4.9) (15.1) 40±0.7 30.2±0.2 58.7±0.2 14.7 Two, M3.5 Three, M4 Allen-head bolt JIS B 0202 G½ Four, 5.2 dia. holes * Stainless sintered roller Adjustable r ange: 25 to 89 67 max. 12.7 41.5±1.5 60±1.5 68.7 65.2±0.8 42 max. 21.6 29.2±1.2 Four, M6 Depth: 15 min 25.4 25.4 13.1 Adjustable roller lever Basic WLCA12-N WLCA12-2-N WLCA12-2N-N High-sensitivity WLG12-N Only the external appearance of the set position indicator plate varies on high-sensitivity models. +2° −1° +2° +2° −1°

Switches with Roller Lever Actuators Basic, High-sensitivity, and Protective Switches Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Note: The actuator on the WLCAL4-N and WLCAL5-N is heavy, which may result in resetting problems depending on the direction the Switch is mounted. Mount the Switch so that the actuator is facing downwards to prevent this problem from occurring. *1. The operating characteristics for WLCL-N, WLCL-2-N, WLCL-2N-N, and WLGL-N are measured at the lever length of 140 mm. *2. The operating characteristics of WLCAL4-N are measured at a rod length of 380 mm. Model Operating characteristics WLCL-N *1 WLCL-2-N *1 WLCL-2N-N *1 WLGL-N *1 WLCAL4-N *2 WLCAL5-N Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. 1.39 N 0.27 N 15±5° 70° 12° 1.39 N 0.27 N 25±5° 60° 16° 1.39 N 0.27 N 20° max. 70° 10° 2.84 N 0.25 N 10° 80° 0.98 N 0.15 N 15±5° 70° 12° 0.9 N 0.09 N 15±5° 70° 12° Model Operating characteristics WLCA32-41 to 44-N Force necessary to reverse the direction of the lever Movement until the lever reverses Movement until switch operation Movement after switch operation max. max. min. 11.77 N 50±5° 55° 35° (4.9) (15.1) 40±0.7 30.2±0.2 Three, M4 Two, M3.5 Allen-head set screw Allen-head set screw JIS B 0202 G½ Four, 5.2 dia. holes ±0.2 dia. (length:160) * 58.7±0.2 Adjustable r ange: 25 to 140 14.7 * Stainless steel rod 55 max. 41.5±1.5 46±1.5 68.7 42 max. 21.6 29.2±1.2 Four, M6 Depth: 15 min. 25.4 25.4 12.7 13.1 Adjustable rod lever 25 to 140 mm Basic WLCL-N WLCL-2-N WLCL-2N-N High-sensitivity WLGL-N Only the external appearance of the set position indicator plate varies on high-sensitivity models. (4.9) (15.1) 40±0.7 30.2±0.2 Three, M4 Four, 5.2 dia. holes 12.8 * Stainless steel rod 3.2 dia. 14.7 58.7±0.2 41.5±1.5 JIS B 0202 G½ Allen-head set screw 68.7 42 max. 21.6 29.2 ±1.2 25.4 25.4 54.5±1.5 67 max. 13.1 12.7 Four , M6 Depth: 15 min. Adjustable range: 350 to 380 Adjustable rod lever Basic WLCAL4-N 67max. (4.9) (15.1) 40±0.7 30.2±0.2 Three, M4 * Piano wire 2.3 dia. 14.7 58.7±0.2 428.5±2 Four, 5.2 dia. holes 41.5±1.5 Four, M6 Depth: 15 min.JIS B 0202 G½ Allen-head bolt 68.7 21.6 29.2 ±1.2 25.4 25.4 54.5±1.5 12.7 13.1 42 max. 7.5 Rod spring lever Basic WLCAL5-N 13.1 12.7 21.6 62.5 max. 56.4±3.5 42.8±3.5 Two, M3.5 Three, M4 Four, 5.2 dia. holes Two, 17.5×7 dia. * 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) (125) 14.7 Four, M6 Depth: 15 min. JIS B 0202 G½ 4-M6 M5 Allen-head set screw 29.2±1.2 42 max. 68.7 34.1 25.4 * Plastic Roller (The WLCA32-041-N to WLCA32-044-N have stainless steel rollers.) 90°±3° R38 Fork lever lock Protective Switches WLCA32-41-N WLCA32-42-N WLCA32-43-N WLCA32-44-N The WLCA32-41-N is shown in the following diagram. +2° −1°

Switches with Plunger Actuators Basic Switches Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics WLD18-N WLD28-N WLD38-N WLSD-N WLSD2-N WLSD3-N Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. max. min. max. 26.67 N 8.92 N 1.7 mm 6.4 mm 1 mm 16.67 N 4.41 N 1.7 mm 5.6 mm 1 mm 16.67 N 4.41 N 1.7 mm 5.6 mm 1 mm 40.03 N 8.89 N 2.8 mm 6.4 mm 1 mm 40.03 N 8.89 N 2.8 mm 5.6 mm 1 mm 40.03 N 8.89 N 2.8 mm 4 mm 1 mm Operating position Total travel position OP TTP max. 34±0.8 mm 29.5 mm 44±0.8 mm 39.5 mm 44.5±0.8 mm 41 mm 40.6±0.8 mm 54.2±0.8 mm 54.1±0.8 mm PT 13.1 12.9 21.6 * Stainless steel plunger Three, M4 Four , 5.2 dia. holes R1 * Two , M3.5 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 10 dia. OP JIS B 0202 G½ Four , M6 Depth: 15 min 29.2±1.2 42 max. 68.7 Sealed Top Plunger WLD18-N Three, M4 Four, 5.2 dia. holes 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 13.1 12.7

21.6 JIS B 0202 G½ Four , M6

Depth: 15 min 29.2±1.2 42 max. 68.7 27.5 46.6±0.8 OP PT *1. Stainless steel plunger *2. Cosmetic nuts 25 dia. *2 Two, M3.5 17.8 (96.2) 25.4 9.3 dia. *1 Horizontal Plunger WLSD-N PT Three, M4 Four, 5.2 dia. holes Two, M3.5 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) OP 13.1 12.9 Depth: 15 min 29.2±1.2 42 max. 68.7 *Stainless sintered roller 14.3 dia.×5 * Sealed Top-roller Plunger WLD28-N Three, M4 Four, 5.2 dia. holes 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 13.1 12.7 Depth: 15 min 29.2±1.2 42 max. 68.7 55.7±0.8 *1. Stainless sintered roller *2. Cosmetic nuts 25 dia. *2 Two, M3.5 17.8 (96.2) 25.4 PT OP 17 dia.×4.6 *1 27.5 Horizontal-roller Plunger WLSD2-N PT Three, M4 Four, 5.2 dia. holes Two, M3.5 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) OP 13.1 12.9

21.6 JIS B0202 G½ Four , M6

Depth: 15 min 29.2±1.2 42 max. 68.7 * Stainless steel ball 1/2" dia. * 15.5 dia. Sealed Top-ball Plunger WLD38-N Three, M4 Four, 5.2 dia. holes 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 13.1 12.7 21.6 JIS B0202 G½ Four , M6 Depth: 15 min 29.2±1.2 42 max. 68.7 46.6±0.8 * 1. Stainless steel ball * 2. Cosmetic nuts 25 dia. *2 Two, M3.5 17.8 (96.2) 25.4 PT OP 15.5 dia. 1/2" dia. *1 27.5 Horizontal-ball Plunger WLSD3-N

Switches with Flexible Rod Actuators Basic Switches Note: Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. * These values are for the top end of the spring, rod, or wire. Model Operating characteristics WLNJ-N WLNJ-30-N WLNJ-2-N WLNJ-S2-N Operating force Pretravel OF PT Max. 1.47 N 20±10 mm 1.47 N 20±10 mm 1.47 N 40±20 mm 0.28 N 40±20 mm Three, M4 Four, 5.2 dia. holes 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 13.1 12.9 Depth: 15 min 29.2±1.2 42 max. 68.7 Two, M3.5 * 3 PT * 1 * 2 (107) 33.7±0.8 140±2.5 6.5 dia. *1. Do not operate the Switch in the direction of the axial center. *2. Stainless steel coil spring. *3. The range for operation is 1/3rd of the overall spring length from the end of the spring. Coil Spring WLNJ-N Three, M4 Four, 5.2 dia. holes 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 13.1 12.9 Depth: 15 min 29.2±1.2 42 max. 68.7 Two, M3.5 * 3 PT * 1 * 2 (107) 33.7±0.8 140±2.5 4.8 dia. *1. Do not operate the Switch in the direction of the axial center. *2. Piano wire coil spring. *3. The range for operation is 1/3rd of the overall spring length from the end of the spring. Coil Spring (Multi-wire) WLNJ-30-N 26 dia. Three, M4 Four, 5.2 dia. holes 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 13.1 12.9 Depth: 15 min 29.2±1.2 42 max. 68.7 Two, M3.5 * 3 PT * 1 * 2 (95.4) 44.6±0.8 140±2.5 8 dia. *1. Do not operate the Switch in the direction of the axial center. *2. Polyamide Resin Rod *3. The range for operation is 1/3rd of the overall rod length from the end of the rod. Resin Rod WLNJ-2-N Three, M4 Four, 5.2 dia. holes 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 13.1 12.9 Depth: 15 min 29.2±1.2 42 max. 68.7 Two, M3.5 * 3 PT * 1 * 2(159) 33.7±0.8 193±2.5 1 dia *1. Do not operate the Switch in the direction of the axial center. *2. Stainless steel wire. *3. The range for operation is 1/3rd of the overall wire length from the end of the wire. Steel Wire WLNJ-S2-N

(For details about applicable cables, refer to Connecting Sensor I/O Connectors Cable and Socket on page 16.) Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The following diagrams are for a indicator-equipped models. Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Switches with Roller Lever Actuators Model Operating characteristics Basic Switches High-sensitivity Switches High-precision Switches Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 10° 80° 13.34 N 1.18 N 80° Sensor I/O connector Switches 40±0.7 30.2±0.2 R38 * Stainless sintered roller 17.5×7 dia. (125) 12.5 (4.9) (15.1) 58.7±0.2 14.7 Two, M3.5 Allen-head bolt M12×1 Three, M4 Four , 5.2 dia. holes 68.7 53.2±0.8 42 max. 29.2±1.2 Four, M6 Depth: 15 min. 25.4 60 max. 12.7 40±1.5 41.5±1.5 53±1.5 25.4 13.1 Switches with Direct-wired Connectors Basic Switches WLCA2-LDK13-N High-sensitivity Switches WLG2-LDK13-N High-precision Switches WLGCA2-LDK13-N The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. 40±0.7 30.2±0.2 * Stainless sintered roller 17.5×7 dia. * SC-1M (125) (4.9) (15.1) 58.7±0.2 14.7 Two, M3.5 Allen-head bolt Three, M4 300 Four, 5.2 dia. holes XS2H-D421 R38 53.2±0.8 +100 −50 42 max. 29.2±1.2 68.7 25.4 60 max. 41.5±1.5 40±1.5 53±1.5 25.4 12.7 13.1 Four, M6 Depth: 15 min Switches with Pre-wired Connectors Basic Switches WLCA2-LD-M1J-N High-sensitivity Switches WLG2-LD-M1J-N High-precision Switches WLGCA2-LD-M1J-N The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. +2° −1° +2° Operation indicator Switches 40±0.7 30.2±0.2 * Stainless sintered roller R38 17.5×7 dia. * (125) (4.9) (15.1) 58.7±0.2 14.7 Two, M3.5 Allen-head bolt Three, M4 Four, 5.2 dia. holes JIS B 0202 G½ 53.2±0.8 42 max. 29.2±1.5 21.6 68.7 25.4 60 max. 53±1.5 41.5±1.5 40±1.5 25.4 13.1 12.7 Four, M6 Depth: 15 min Roller lever WLCA2-LD-N WLCA2-LE-N Model Operating characteristics WLCA2-LD-N WLCA2-LE-N Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. 13.34 N 1.18 N 15±5° 70° 12°

Switches with Roller Lever Actuators Switches with Sealed Top-roller Plungers Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The above diagrams are for Indicator-equipped Switches. Spatter-prevention Switches Actuator Switches with Roller Lever Actuators Switches with Sealed Top- roller PlungersOperating characteristics Basic Switches High-sensitivity Switches High-precision Switches Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 10° 80° 13.34 N 1.18 N 80° 16.67 N 4.41 N Max.1.7 mm 5.6 mm 1 mm Operating position Total travel position OT TTP max. 44±0.8 mm 39.5 mm 17.5×7 dia. * (125) (4.9) (15.1) 40±0.7 30.2±0.2 R38 Two, M3.5 Allen-head bolt Fluorine resin cap Three, M4 JIS B 0202 G½ Four, 5.2 dia. holes * Stainless sintered roller 58.7 ±0.2 14.7 68.7 21.6 53.2±0.8 42 max. 29.2±1.2 Four, M6 Depth: 15 min 25.4 60 max. 12.7 40±1.5 41.5±1.5 53±1.5 25.4 13.1 Switches with Screw Terminals Basic Switches WLCA2-@S-N High-sensitivity Switches WLG2-@S-N High-precision Switches WLGCA2-@S-N The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. Four, M6 Depth: 15 min 40±0.7 30.2±0.2 * Stainless sintered roller 17.5×7 dia. * SC-1M (125) (4.9) (15.1) 58.7±0.2 14.7 Two, M3.5 Allen-head bolt Three, M4 Four, 5.2 dia. holes XS2H-D421 R38 53.2±0.8 42 max. 68.7 25.4 60 max. 41.5±1.5 40±1.5 300 53±1.5 25.4 13.1 12.7 +100 −50 29.2±1.2 Fluorine resin cap Switches with Pre-wired Connectors WLCA2-@S-M1J-N PT *Stainless sintered roller 14.3 dia.×5 * Two , M3.5 OP 42 max. 13.1 12.9 21.6 Depth: 15 minJIS B 0202 G½ Four , M6 29.2±1.2 68.7 Rubber cap (fluorine rubber) Three, M4 Four, 5.2 dia. holes 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) Switches with Screw Terminals WLD28-@S-N *Stainless sintered roller 42 max. 13.1 12.9 Depth: 15 min Four, M6 29.2±1.2 68.7 Rubber cap (fluorine rubber) 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) Three, M4 XS2H-D421 14.3 dia.×5 * Two , M3.5 Four, 5.2 dia. holes SC-1M −50 +100 300 PT OP Switches with Pre-wired Connectors WLD28-@S-M1J-N +2° −1° +2°

Switches with Roller Lever Actuators Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. The above diagrams are for Indicator-equipped Switches. Long-life Switches Actuator Switches with Roller Lever Actuators Operating characteristics Basic Switches High-sensitivity Switches High-precision Switches Operating force Release force Pretravel Overtravel Movement Differential OF RF PT OT MD max. min. min. max. 13.34 N 1.18 N 15±5° 70° 12° 13.34 N 1.18 N 10° 80° 13.34 N 1.18 N 80° 42 max. 13.1 12.7 Depth: 15 min JIS B 0202 G½ Four , M6 29.2±1.2 68.7 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 14.7 60 max. 53±1.5 41.5±1.5 53.2±0.8 *Stainless sintered roller Two, M3.5 Three, M4 Four, 5.2 dia. holes 17.5 dia.×7 * M5 Allen-head bolt Fluorine resin cap 25.4 25.4 40±1.5 R38 21.6 Switches with Screw Terminals Basic Switches WLMCA2-LD-N High-sensitivity Switches WLMG2-LD-N High-precision Switches WLMGCA2-LD-N The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. 42 max. 13.1 12.7 Depth: 15 min Four, M6 29.2±1.2 68.7 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 14.7 60 max. 53±1.5 41.5±1.5 53.2±0.8 *Stainless sintered roller Two, M3.5 Three, M4 M12×1 Four, 5.2 dia. holes 17.5 dia.×7 * M5 Allen-head bolt Fluorine resin cap 25.4 25.4 40±1.5 R38 12.5 Switches with Direct-wired Connectors Basic Switches WLMCA2-LDK13-N High-sensitivity Switches WLMG2-LDK13-N High-precision Switches WLMGCA2-LDK13-N The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. 42 max. 13.1 12.7 Depth: 15 min Four, M6 29.2±1.2 68.7 30.2±0.2 40±0.7 (4.9) 58.7±0.2 (15.1) 14.7 60 max. 53±1.5 41.5±1.5 53.2±0.8 *Stainless sintered roller Two, M3.5 17.5 dia.×7 * M5 Allen-head bolt Fluorine resin cap 25.4 25.4 40±1.5 R38 SC-1M XS2H-D421 Three, M4 Four, 5.2 dia. holes −50 +100300 Switches with Pre-wired Connectors Basic Switches WLMCA2-LD-M1J-N High-sensitivity Switches WLMG2-LD-M1J-N High-precision Switches WLMGCA2-LD-M1J-N The only difference in the shape for High-sensitivity and High-precision Switches is the set position marker plate. +2° −1° +2°

Actuators (Levers Only) Lever: Only rotating lever models are illustrated. Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. Lever: Only rotating lever models are illustrated. 11.4 17.5 dia. × 7, sintered stainless steel roller 7.3-dia. mounting holes 38 Allen-head bolt 54.8 17.9 12.6 WL-1A100 Standard Lever 11.4 17.5 dia. (length: 7) resin roller 7.3-dia. mounting holes 38 Allen-head bolt 54.8 17.9 12.6 WL-1A115 Resin Roller 11.4 17 dia. (length: 6) bearing roller 7.3-dia. mounting holes 38 Allen-head bolt 54.8 16.9 12.1 WL-1A400 Bearing Roller 11.4 17.5 dia. (length: 30) Nylon roller 7.3-dia. mounting holes Allen-head bolt 54.8 40.2 ±0.8 23.6 WL-1A118 Nylon Roller: Roller Width: 30 mm 11.4 17.5 dia. × 7, sintered stainless steel roller 7.3-dia. mounting holes 38 Two , M5 Allenhead nut and arm set screw 54.8 17.9 12.6 WL-1A105 Double Nuts 11.4 17.5 dia. (length: 7) stainless steel roller 7.3-dia. mounting holes 38 Allen-head bolt 54.8 17.9 12.6 WL-1A103S Spatter 17.5 dia. × 15, sintered stainless steel roller 7.3-dia. mounting holes Allen-head bolt 66.8 11.4 25.7 16.6 WL-1A200 Lever Length: 50 Roller Width: 15 7.3-dia. mounting holes Allen-head bolt 79.8 17.5 dia. × 7, sintered stainless steel roller 11.4 17.9 12.6 WL-1A300 Lever Length: 63 17.5 dia. × 7, sintered stainless steel roller Adjustable lever : stainless steel 7.3-dia. mounting holes Allen-head bolt Adjustable r ange: 25 to 89 24.9±0.8 19.7±0.8 105.75 WL-2A100 17.5 dia. (length: 7) resin roller Adjustable lever : stainless steel 7.3-dia. mounting holes M5 Allen-head bolt Adjustable r ange: 25 to 89 24.9±0.8 19.7±0.8 105.75 WL-2A111 Resin Roller 17.5 dia. × 7, sintered stainless steel roller Adjustable lever stainless steel 7.3-dia. mounting holes Adjustable r ange: 28 to 88 24.9±0.8 19.7±0.8 105.75 Allen-head bolt Two, M5 Allen-head nut and arm set screw WL-2A107 Double Nuts (15.8) 6.2 17.5 dia. (length: 7) resin roller Adjustable lever: stainless steel 7.3-dia. mounting holes Allen-head bolt Adjustable range: 25 to 140 24.9 ±0.8 19.7±0.8 155.75 WL-2A108 Resin Roller (15.8) 6.2 17.5 dia. × 7, sintered stainless steel roller Adjustable lever: stainless steel 7.3-dia. mounting holes Allen-head bolt Adjustable range: 25 to 140 24.9 ±0.8 19.7±0.8 155.75 WL-2A122 17.5 dia. × 7, sintered stainless steel roller Adjustable lever stainless steel 7.3-dia. mounting holes M5 Allen-head bolt Adjustable r ange: 25 to 89 24.9±0.8 19.7±0.8 105.75 9.1 * Can be installed on the rear side. WL-2A106 24.7±0.8 19.5±0.8 (112) Allen-head bolt (10) (21.8) (10) 17.5 dia. × 7, sintered stainless steel roller R89.5 15.9 Three , 5.3 dia. holes 7.3 dia. mounting holes +0.2 WL-2A130 2312 50 dia. (length: 6) Nylon roller 7.3-dia. mounting holes Allen-head bolt Adjustable from 42 to 89 24.9±0.8 19.7±0.8 WL-2A104

Note: 1. Unless otherwise indicated, a tolerance of ±0.4 mm applies to all dimensions. 2. When using the adjustable roller (rod) lever, make sure that the lever is facing downwards. Use caution, as telegraphing (the Switch turns ON and OFF repeatedly due to inertia) may occur. 50 dia. (length: 15) Nylon roller 7.3-dia. mounting holes Allen-head bolt Adjustable from 41 to 78.5 34.5 24.4 122 23 WL-2A110 49 dia. rub ber roller Material: NBR 7.3-dia. mounting holes Allen-head bolt Adjustable from 41 to 34.2 24.2 WL-2A105 11.5 50 dia. (length: 6) Nylon roller 7.3-dia. mounting holes Allen-head bolt 20.1 ±0.8 R38 WL-1A106 11.5 35 dia. (length: 6) Nylon roller 7.3 dia. mounting holes Allen-head bolt 16 20.1±0.8 R38 WL-1A110 3-dia. stainless steel rod 7.3-dia. mounting holes Allen-head bolt Adjustable from 25 to 140 160 Allen-head set screw WL-4A100 2-dia. stainless steel for spring 7.3-dia. mounting holes Allen-head bolt Adjustable from 270 to 290 Allen-head set screw WL-4A201 Actuator's center of rotation 7.3-dia. mounting holes 400 12.8 7.5 Allen-head bolt 3.2-dia. stainless steel rod Adjustable from 350 to 380 25.5 max. 13.4 WL-3A100 7.3-dia. mounting holes 400 12.8 7.5 Two, M5 Allenhead nut and arm set screw 3.2-dia. stainless steel rod Adjustable from 350 to 380 25.5 max. 13.4 Allen-head bolt WL-3A106 Double Nut 7.3-dia. mounting holes 680 ±0.4 12.8 7.5 Allen-head bolt 3.2-dia. stainless steel rod Adjustable from 650 to 660 25.5 max. 13.4 WL-3A108 7.3-dia. mounting holes 450 417.5±2 7.5 7.5 12.5 dia. max. Allen-head bolt 2.3-dia. oper ation rod 24.6 max. (95) WL-3A200 7.3-dia. mounting holes 470 437.5±2 8 dia. 7.5 12.5 dia. max. Allen-head bolt 2.3 dia. rod 7.5 24.6 max. (95) Cap Adhesive WL-3A203 4-dia. stainless steel rod 7.3-dia. mounting holes Allen-head bolt Adjustable up to 141 160 ±1.5 Allen-head set screw WL-4A112 15.8 (108) Allen-head bolt (18.5) 11.3 15.9 22.1 7.3 dia. mounting hole 8495.3 Three, 5.2 dia. holes Marking R8 WL-2A129 WL-5A100 has a plastic roller Two, 17.5 dia. × 7, sintered stainless steel rollers M5 Allen-head bolt 11 1.3 6.7 17.7 54.8 90° R387.3 dia. 12.4 WL-5A101 WL-5A102 has a plastic roller Two, 17.5 dia. × 7, sintered stainless steel rollers M5 Allen-head bolt 11 1.3 17.7 54.8 90° R38 6.7 12.4 7.3 dia. WL-5A103 WL-5A104 has a plastic roller Two, 17.5 dia. × 7, sintered stainless steel rollers M5 Allen-head bolt 11 17.7 12.4 54.8 90° R387.3 dia. WL-5A105

WLCA2-55LDK13 WLCA2-55LDK13-N WLCA2-LDK43 WLCA2-LDK43-N WLCA2-55LDK43 WLCA2-55LDK43-N WLD2-LDK13 WLD28-LDK13-N WLD2-55LDK13 WLD28-55LDK13-N WLD2-LDK43 WLD28-LDK43-N WLD2-55LDK43 WLD28-55LDK43-N WLH2-LDK13 WLCA2-LDK13-N WLH2-55LDK13 WLCA2-55LDK13-N WLH2-LDK43 WLCA2-LDK43-N WLH2-55LDK43 WLCA2-55LDK43-N WLG2-LDK13 WLG2-LDK13-N WLG2-55LDK13 WLG2-55LDK13-N WLG2-LDK43 WLG2-LDK43-N WLG2-55LDK43 WLG2-55LDK43-N WLGCA2-LDK13 WLGCA2-LDK13-N WLGCA2-55LDK13 WLGCA2-55LDK13-N WLGCA2-LDK43 WLGCA2-LDK43-N WLGCA2-55LDK43 WLGCA2-55LDK43-N WLCA2-LD-M1J WLCA2-LD-M1J-N WLCA2-55LD-M1J WLCA2-55LD-M1J-N WLCA2-LD-M1GJ WLCA2-LD-M1GJ-N WL WL-N Model Replacement Table

WLCA2-55LD-M1GJ WLCA2-55LD-M1GJ-N WLCA2-55LD-M1JB WLCA2-55LD-M1JB-N WLCA2-LD-DGJ03 WLCA2-LD-DGJ-N WLCA2-55LD-DGJ03 WLCA2-55LD-DGJ-N WLCA2-LD-DK1EJ03 WLCA2-LD-DK1EJ-N WLCA2-55LD-DK1EJ03 WLCA2-55LD-DK1EJ-N WLD2-LD-M1J WLD28-LD-M1J-N WLD2-55LD-M1J WLD28-55LD-M1J-N WLD2-LD-M1GJ WLD28-LD-M1GJ-N WLD2-55LD-M1GJ WLD28-55LD-M1GJ-N WLD2-55LD-M1JB WLD28-55LD-M1JB-N WLD2-LD-DGJ03 WLD28-LD-DGJ-N WLD2-LD-DK1EJ03 WLD28-LD-DK1EJ-N WLD2-55LD-DK1EJ03 WLD28-55LD-DK1EJ-N WLH2-LD-M1J WLCA2-LD-M1J-N WLH2-LD-M1GJ WLCA2-LD-M1GJ-N WLH2-LD-DGJ03 WLCA2-LD-DGJ-N WLG2-LD-M1J WLG2-LD-M1J-N WLG2-LD-M1GJ WLG2-LD-M1GJ-N WLG2-55LD-M1GJ WLG2-55LD-M1GJ-N WLG2-LD-M1JB WLG2-LD-M1JB-N WLG2-55LD-M1JB WLG2-55LD-M1JB-N WLG2-LD-DGJ03 WLG2-LD-DGJ-N WLG2-55LD-DGJ03 WLG2-55LD-DGJ-N WLG2-LD-DK1EJ03 WLG2-LD-DK1EJ-N WLG2-55LD-DK1EJ03 WLG2-55LD-DK1EJ-N WLGCA2-LD-M1J WLGCA2-LD-M1J-N WLGCA2-55LD-M1J WLGCA2-55LD-M1J-N WLGCA2-LD-M1GJ WLGCA2-LD-M1GJ-N WLGCA2-55LD-M1JB WLGCA2-55LD-M1JB-N WLGCA2-55LD-DGJ03 WLGCA2-55LD-DGJ-N WLCA2-55 WLCA2-55-N WLCA2-55LD WLCA2-55LD-N WLCA2-55LE WLCA2-55LE-N WLCA2-139 WLCA2-139-N WLCA2-139LD2 WLCA2-139LD2-N WLCA2-139LD3 WLCA2-139LD3-N WLCA2-140 WLCA2-140-N WLCA2-140LD2 Ask your OMRON representative. WLCA2-140LD3 Ask your OMRON representative. WLCA2-141 WLCA2-141-N WLCA2-141LD2 WLCA2-141LD2-N WLCA2-141LD3 WLCA2-141LD3-N WLCA2-RP60 WLCA2-RP60-N WLCA2-RP60LD2 WLCA2-RP60LD2-N WLCA2-RP60LD3 WLCA2-RP60LD3-N WLCA2-TH WLCA2-TH-N WLCA2-TC WLCA2-TC-N WLCA2-RP WLCA2-RP-N WLCA2-P1 WLCA2-P1-N WLH2-55 WLCA2-55-N WLH2-55LD WLCA2-55LD-N WL WL-N WLH2-55LE WLCA2-55LE-N WLH2-139 WLCA2-139-N WLH2-140 WLCA2-140-N WLH2-141 WLCA2-141-N WLH2-141LD3 WLCA2-141LD3-N WLH2-RP60 WLCA2-RP60-N WLH2-RP60LD3 WLCA2-RP60LD3-N WLH2-TH WLCA2-TH-N WLH2-TC WLCA2-TC-N WLH2-RP WLCA2-RP-N WLH2-P1 WLCA2-P1-N WLG2-55 WLG2-55-N WLG2-55LD WLG2-55LD-N WLG2-55LE WLG2-55LE-N WLG2-139 WLG2-139-N WLG2-139LD3 WLG2-139LD3-N WLG2-140 WLG2-140-N WLG2-140LD2 Ask your OMRON representative. WLG2-140LD3 Ask your OMRON representative. WLG2-141 WLG2-141-N WLG2-141LD2 WLG2-141LD2-N WLG2-141LD3 WLG2-141LD3-N WLG2-RP60 WLG2-RP60-N WLG2-RP60LD2 WLG2-RP60LD2-N WLG2-RP60LD3 WLG2-RP60LD3-N WLG2-TH WLG2-TH-N WLG2-TC WLG2-TC-N WLG2-RP WLG2-RP-N WLG2-P1 WLG2-P1-N WLCA2-255 WLCA2-255-N WLCA2-255LD WLCA2-255LD-N WLCA2-255LE WLCA2-255LE-N WLCA2-2139 WLCA2-2139-N WLCA2-2139LD2 WLCA2-2139LD2-N WLCA2-2139LD3 WLCA2-2139LD3-N WLCA2-2RP60 WLCA2-2RP60-N WLCA2-2RP60LD2 WLCA2-2RP60LD2-N WLCA2-2RP60LD3 WLCA2-2RP60LD3-N WLCA2-2TH WLCA2-2TH-N WLCA2-2TC WLCA2-2TC-N WLCA2-2N55 WLCA2-2N55-N WLCA2-2N55LD WLCA2-2N55LD-N WLCA2-2N55LE WLCA2-2N55LE-N WLCA2-2N139 WLCA2-2N139-N WLCA2-2N140 WLCA2-2N140-N WLCA2-2NTH WLCA2-2NTH-N WLCA2-2NTC WLCA2-2NTC-N WLGCA2-55 WLGCA2-55-N WLGCA2-55LD WLGCA2-55LD-N WLGCA2-55LE WLGCA2-55LE-N WLGCA2-139 WLGCA2-139-N WLGCA2-139LD2 WLGCA2-139LD2-N WL WL-N WLGCA2-139LD3 WLGCA2-139LD3-N WLGCA2-140 Ask your OMRON representative. WLGCA2-140LD2 Ask your OMRON representative. WLGCA2-140LD3 Ask your OMRON representative. WLGCA2-141 WLGCA2-141-N WLGCA2-141LD3 WLGCA2-141LD3-N WLGCA2-RP60 WLGCA2-RP60-N WLGCA2-RP60LD2 WLGCA2-RP60LD2-N WLGCA2-RP60LD3 WLGCA2-RP60LD3-N WLGCA2-TH WLGCA2-TH-N WLGCA2-TC WLGCA2-TC-N WLGCA2-RP WLGCA2-RP-N WLCA12-55 WLCA12-55-N WLCA12-55LD WLCA12-55LD-N WLCA12-55LE WLCA12-55LE-N WLCA12-139 WLCA12-139-N WLCA12-140 WLCA12-140-N WLCA12-141 WLCA12-141-N WLCA12-RP60 WLCA12-RP60-N WLCA12-TH WLCA12-TH-N WLCA12-TC WLCA12-TC-N WLCA12-RP WLCA12-RP-N WLCA12-P1 WLCA12-P1-N WLH12-TH WLCA12-TH-N WLH12-TC WLCA12-TC-N WLH12-RP WLCA12-RP-N WLH12-P1 WLCA12-P1-N WLG12-TH WLG12-TH-N WLG12-TC WLG12-TC-N WLG12-RP WLG12-RP-N WLG12-P1 WLG12-P1-N WLCA12-2TH WLCA12-2TH-N WLCA12-2TC WLCA12-2TC-N WLCA12-2NTH WLCA12-2NTH-N WLCA12-2NTC WLCA12-2NTC-N WLCL-55 WLCL-55-N WLCL-55LD WLCL-55LD-N WLCL-139 WLCL-139-N WLCL-140 WLCL-140-N WLCL-RP60 WLCL-RP60-N WLCL-TH WLCL-TH-N WLCL-TC WLCL-TC-N WLCL-RP WLCL-RP-N WLCL-P1 WLCL-P1-N WLHL-TH WLCL-TH-N WLHL-TC WLCL-TC-N WLHL-RP WLCL-RP-N WLHL-P1 WLCL-P1-N WLGL-TH WLGL-TH-N WLGL-TC WLGL-TC-N WLGL-RP WLGL-RP-N WLGL-P1 WLGL-P1-N WL WL-N

Ask your OMRON representative. WLNJ-2RP WLNJ-2RP-N WLCA2-LEAS WLCA2-LEAS-N WLH2-LEAS WLCA2-LEAS-N WL WL-N WLG2-LEAS WLG2-LEAS-N WLCA2-LDAS WLCA2-LDAS-N WLH2-LDAS WLCA2-LDAS-N WLG2-LDAS WLG2-LDAS-N WLCA2-LES WLCA2-LES-N WLH2-LES WLCA2-LES-N WLG2-LES WLG2-LES-N WLGCA2-LES WLGCA2-LES-N WLCA2-LDS WLCA2-LDS-N WLH2-LDS WLCA2-LDS-N WLG2-LDS WLG2-LDS-N WLGCA2-LDS WLGCA2-LDS-N WLD28-LES WLD28-LES-N WLD28-LDS WLD28-LDS-N WLMCA2-LD WLMCA2-LD-N WLMCA2-LDK13A WLMCA2-LDK13A-N WLMCA2-LDK13 WLMCA2-LDK13-N WLMCA2-LDK43A WLMCA2-LDK43A-N WLMCA2-LDK43 WLMCA2-LDK43-N WLMCA2-LD-M1J WLMCA2-LD-M1J-N WLMCA2-LD-DGJ03 WLMCA2-LD-DGJ-N WLMGCA2-LD WLMGCA2-LD-N WLMGCA2-LDK13A WLMGCA2-LDK13A-N WLMGCA2-LDK13 WLMGCA2-LDK13-N WLMGCA2-LDK43A WLMGCA2-LDK43A-N WLMGCA2-LDK43 WLMGCA2-LDK43-N WLMGCA2-LD-M1J WLMGCA2-LD-M1J-N WLMH2-LD WLMCA2-LD-N WLMH2-LDK13A WLMCA2-LDK13A-N WLMH2-LDK13 WLMCA2-LDK13-N WLMH2-LDK43A WLMCA2-LDK43A-N WLMH2-LDK43 WLMCA2-LDK43-N WLMH2-LD-M1J WLMCA2-LD-M1J-N WLMH2-LD-DGJ03 WLMCA2-LD-DGJ-N WLMG2-LD WLMG2-LD-N WLMG2-LDK13A WLMG2-LDK13A-N WLMG2-LDK13 WLMG2-LDK13-N WLMG2-LDK43A Ask your OMRON representative. WLMG2-LDK43 WLMG2-LDK43-N WLMG2-LD-M1J WLMG2-LD-M1J-N WLMG2-LD-DGJ03 WLMG2-LD-DGJ-N WLRCA2 WLRCA2-N WLRGCA2 WLRGCA2-N WLRG2 WLRG2-N WLRH2 WLRCA2-N WLRCA2-2 WLRCA2-2-N WLRCA2-2N WLRCA2-2N-N WLRCA2 WLRCA2-N WLRG2 WLRG2-N WLRH2 WLRCA2-N WLRCA2-2 WLRCA2-2-N WLRCA2-2N WLRCA2-2N-N WL WL-N WLRCL WLRCA2-N WLRG2 WLRG2-N WLRCA2-2 WLRCA2-2-N WLRCA2-2N WLRCA2-2N-N WLRCA32 WLRCA32-N WLRCA2-LDS WLRCA2-LDS-N WLRH2-LES WLRCA2-LES-N WLRH2-LDS WLRCA2-LDS-N WLRG2-LDS WLRG2-LDS-N WLRGCA2-LES WLRGCA2-LES-N WL WL-N

  • Be sure to ground. If not, there is the possibility that electrical shock occurs.
  • Do not touch charged switch terminals while the switch has carry current, otherwise there is the possibility that electrical shock occurs.
  • Do not disassemble the limit switch or touch inside of it under supplying power, otherwise there is the possibility that electrical shock occurs.
  • Do not touch the wire or rod type actuator in order to prevent injury.
  • Connect a fuse which has 1.5 to 2 times higher breaking current than the switch rated current to the switch in series in order to prevent the switch from short-circuit damage. On the occasion when using the switch with GB ratings, use a 10A fuse that complies IEC60269, either type gG.
  • The durability of switch is depends on the operating condition. Be sure to check the condition with actual using condition before using, and use with the number of times of operating without a performance problem.
  • Do not drop the switch. Otherwise, there is the possibility that the switch functions may be spoiled.
  • Do not connect a Single Limit Switch to two power supplies that are different in polarity or type.
  • Be sure to keep the load current less than the rated value. Otherwise, there is the possibility that the switch may be damage and/or burnout.
  • Minimum operating load: 5 VDC 1 mA, resistive load, P level Note: The P level indicates the standard malfunction level at a reliability level of 60% (λ60). (JISC5003) λ60 = 0.1 × 10 -6 per operation, which indicates an estimated malfunction of 1 out of every 10,000,000 operations at a reliability level of 60%.
  • Do not use the Switch by itself in atmospheres containing flammable or explosive gases. Arcs and heating resulting from switching may cause fire or explosion.
  • Be sure to prevent the foreign materials such like a scrapped cable intrusion in to the switch when wiring. Otherwise, there is the possibility of spoiling the normal operation.
  • Never wire to the wrong terminals.
  • Do not store or use the switch with following place. Where the temperature fluctuates greatly Where the humidity is very high and condensation may occur. Where the vibration is too much Where receiving direct sunshine. Where receiving salty wind.
  • Do not disassemble and/or modify the switch at anytime. Otherwise, there is the possibility of spoiling the normal operation.
  • Do not apply the force such like deformation and/or degeneration to the switch. Otherwise, there is the possibility that the switch functions may be spoiled. Environment
  • Take special care to use where there is fine powder, mud and/or foreign materials stacking. And check the condition with actual using condition before using. Then use without a performance problem.
  • This switch is only for indoor use. If it is used in outdoor, it may be cause of switch failure.
  • Do not keep the Switch in locations with corrosive gas, such as sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3), or chlorine gas (Cl2), or high temperature and humidity. Otherwise, contact failure or corrosion damage may result.
  • Seal material may deteriorate if a Switch is used outdoor or where subject to special cutting oils, solvents, or chemicals. Always appraise performance under actual application conditions and set suitable maintenance and replacement periods.
  • Install Switches where they will not be directly subject to cutting chips, dust, or dirt. The Actuator and Switch must also be protected from the accumulation of cutting chips or sludge.
  • Constantly subjecting a Switch to vibration or shock can result in wear, which can lead to contact interference with contacts, operation failure, reduced durability, and other problems. Excessive vibration or shock can lead to false contact operation or damage. Install Switches in locations not subject to shock and vibration and in orientations that will not produce resonance.
  • The Switches have physical contacts. Using them in environments containing silicon gas will result in the formation of silicon oxide (SiO 2) due to arc energy. If silicon oxide accumulates on the contacts, contact interference can occur. If silicon oil, silicon filling agents, silicon cables, or other silicon products are present near the Switch, suppress arcing with contact protective circuits (surge killers) or remove the source of silicon gas. Installing the Switch
  • To install the Switch, make a mounting panel, as shown in the following diagram, and tighten screws using the correct torque. Precautions for Safe Use Precautions for Correct Use Not Suitable Suitable +0.2 +0.2 Front Mountig : Four, 5.2 dia. holes or M5 tapped holes Rear Mountig : Four, 6.2 dia. holes ±0.1530.2 58.7±0.15
  • If screws are too loose they can lead to an early malfunction of the Switch, so ensure that all screws are tightened using the correct torque.
  • In particular, when changing the direction of the Head, make sure that all screws are tightened again to the correct torque. Do not allow foreign objects to fall into the Switch. Wring In the case of mounting screw
  • Use M3.5-nylon insulation covered crimp terminals (round type) for wiring.
  • Appropriate wire size is AWG16 (1.25mm2).
  • Do not supply electric power when wiring. Otherwise electric shock may result.
  • Do not pull out the wires with excessive force. It may cause of coming off the wire.
  • Use crimp terminals for wiring.
  • In the case of lump unit, to avoid interference between lump unit and crimp terminals, wire according to right wiring figure. Attach the lump unit spring to terminal screw certainly otherwise itÅfs possible to be destroyed or shorted.
  • The ground terminal is only installed on models with ground terminals. In the case of prewired connecter and direct connecter
  • Holding the connecter certainly when pulling connecter.
  • Don’t pull the cable holding it. How to handle Changing direction of the head
  • By removing the screws in the two corners of the head, the head can be set any of four directions. Be sure to change the plunger for internal operations at the same time. Built-in Switch
  • Do not remove or replace the built-in switch. Overtravel Markers
  • All Switches with Roller Lever Actuators except for Switches with Fork Lever Locks and Low-temperature Switches have a set position marker plate.
  • To allow the roller lever type actuator to travel properly, set the roller lever according to the dog or cam stroke so that the arrowhead of the lever is positioned within overtravel markers as shown. Connectors
  • Tighten the connector with the appropriate torque to prevent deformation.
  • Use the OMRON type SC connector series, which is prepared separately, suitable for outer diameter of cable and inner diameter of seal rubber.
  • Make sure to wrap the connector with the seal tape, except the connector which has O-ring, to keep the sealability.
  • To conform to CSA, use a CSA certified water tight treated conduit hub.
  • Even when the connector is assembled and set correctly, the end of the cable and the inside of the Switch may come in contact. This can lead to malfunction, leakage current, or fire, so be sure to protect the end of the cable from splashes of oil or water and corrosive gases. Microload Applications
  • The switch contacts can be used both for standard loads and microloads, but once a contact has been used to open and close a load it can no longer be used for lower loads. Doing so will damage the contact surface and reduce contact reliability.
  • If an inrush current or other sudden load occurs during a switch operation, the switch will begin to degrade severely which can result in reduced durability. Use a contact protection circuit if required. Indicator Indicator-equipped switch has contacts and indicator in parallel. When contacts are open, leakage current flows through the indicator circuit and may cause load's malfunction. Please check the load's OFF current before use the indicatorequipped switch. Leakage current may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current is higher than the leakage current. For countermeasures, refer to technical support on your OMRON website. Terminal Plate
  • By using the Terminal Plate (sold separately), as shown in the following diagram, the Switch can be used as a single-polarity double-break switch. No. Type Torque Screw type (1) Head mounting screw 0.78 to 0.88 Nm M3.5 screw (2) Cover mounting screw 1.18 to 1.37 Nm M4 screw (3) Allen-head bolt (for securing the roller lever) 4.90 to 5.88 Nm M5 hexagon socket head cap screw (3) Allen-head bolt (for securing the adjustable rod lever) 0.88 to 1.08 Nm M8 hexagon socket set screw (4) Terminal screw 0.59 to 0.78 Nm M3.5 screw (5) Connector 1.77 to 2.16 Nm G1/2orPg13.5orM20or 1/2-14NPT (6) Unit mounting screw 4.90 to 5.88 Nm M5 hexagon socket head cap screw (3) (4) (2) (1) (6) (5) Excessive OT Setting range Shortage OT Setting range Excessive OT Arrowhead Screw downHead Terminal Plate Attach the Terminal Plate so that the “COM” mark is oriented as shown on the left. Terminal Plate Mounting Diagram (with Two Terminal Screws Removed) Model WL-N TERMINAL PLATE

Using a WL@-2N Switch Mounted from the Side If you replace a previous Switch with a WL@-2N-N Switch, a Mounting Plate (sold separately) is available to maintain mounting compatibility. If you use the Mounting Plate, the Switch mounting holes and actuator position will be compatible. (The position of the dog will not need to be changed.) Operation

  • Carefully determine the position and shape of the dog or cam so that the actuator will not abruptly snap back, thus causing shock. In order to operate the Limit Switch at a comparatively high speed, use a dog or cam that keeps the Limit Switch turned ON for a sufficient time so that the relay or valve will be sufficiently energized.
  • The method of operation, the shape of the cam or dog, the operating frequency, and the travel after operation have a large influence on the durability and operating accuracy of the Limit Switch. The cam or dog must be smooth in shape.
  • Appropriate force must be imposed on the actuator by the cam or dog in both rotary operation and linear operation. If the dog touches the lever as shown below, the operating position will not be stable.
  • Unbalanced force must not be imposed on the actuator. Otherwise, wear and tear on the actuator may result.
  • With a roller actuator, the dog must touch the actuator at a right angle. The actuator or shaft may deform or break if the dog touches the actuator (roller) at an oblique angle.
  • Make sure that the actuator does not exceed the OT (overtravel) range, otherwise the Limit Switch may malfunction. When mounting the Limit Switch, be sure to adjust the Limit Switch carefully while considering the whole movement of the actuator.
  • The Limit Switch may soon malfunction if the OT is excessive. Therefore, adjustments and careful consideration of the position of the Limit Switch and the expected OT of the operating body are necessary when mounting the Limit Switch.
  • When using a pin-plunger actuator, make sure that the stroke of the actuator and the movement of the dog are located along a single straight line. Others
  • For long term (over a year) storage, check according to Operating characteristics, Contact resistance and Dielectric strength at least. And check with using condition.
  • The durability of the Switch is greatly affected by operating conditions. Evaluate the Switch under actual working conditions before permanent installation and use the Switch within a number of switching operations that will not adversely affect the SwitchÅfs performance. 30.2 58.7 WL@-2N Mounting Plate Replacing a Switch with the WL@-2N-N Mounting Plate Set

contents

bolts (2) Plate (1) Switch mounting bolts (2) Incorrect Correct Snapped back Abruptly actuated Incorrect Correct Snapped back Abruptly actuated Incorrect Dog Dog Correct Incorrect Correct RollerRoller Dog Dog CorrectIncorrect Dog Dog Operating body Install a stopper. PT (Pretravel) FP (Free position) OP (Operating position) OT (Overtravel) TTP (Total travel position) Reference line 70% of rated OT 100% of rated OT Distance to the optimum setting range. Optimum setting range Correct Stopper Incorrect Correct Operating body Operating body

Item Applicable models and Actuators Details Changing the Installation Position of the Actuator By loosening the Allen-head bolt on the actuator lever, the position of the actuator can be set anywhere within the 360°. With Indicator-equipped Switches, the actuator lever comes in contact with the top of the indicator cover, so use caution when rotating and setting the lever. When the lever only moves forwards and backwards, it will not contact the lamp cover. (This does not apply to Long-life Switches.) Roller Levers: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2-N, WLCA2-7-N, WLCA2-8-N, WLGCA2-N, WLMCA2-N, WLMG2-N, WLMGCA2-N) Adjustable Roller Levers: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12-N) Adjustable rod lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL-N, WLCAL4-N, WLCAL5-N) Changing the Orientation of the Head By removing the two screws of the Head, the Head can be set in any of the four directions. Be sure to change the plunger for internal operations at the same time. The roller plunger can be set in either of two positions at 90° Roller Levers: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2-N, WLCA2-7-N, WLCA2-8-N, WLGCA2-N, WLMCA2-N, WLMG2-N, WLMGCA2-N) Adjustable Roller Levers: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12-N) Adjustable rod lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL-N, WLCAL4-N, WLCAL5-N) Horizontal plunger (WLSD@-N) Sealed top-roller plunger (WLD28-N) Note: Does not include the -RP60 Series or -141 Series. Changing the Operating Direction By removing the Head on models which can operate on one-side only, and then changing the direction of the operational plunger, one of three operating directions can be selected. Roller Levers: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2-N, WLCA2-7-N, WLCA2-8-N, WLGCA2-N, WLMCA2-N, WLMG2-N, WLMGCA2-N) Adjustable Roller Levers: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12-N) Adjustable rod lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL-N, WLCAL4-N, WLCAL5-N) Installing the Roller on the Inside By installing the roller lever in the opposite direction, the roller can be installed on the inside. (Set so that operation can be completed within a 180° level range.) Roller Levers: (WLCA2-N, WLCA2-2-N, WLCA2-2N-N, WLG2-N, WLCA2-7-N, WLCA2-8-N, WLGCA2-N, WLMCA2-N, WLMG2-N, WLMGCA2-N) Fork lever lock: (WLCA32-4@-N) Note: Except for Switches with variable roller levers. Loosen the Allen-head bolt, set the actuator's position and then tighten the bolt again. Head Loosen the screws. Operating Operating OperatingNot operating Operating Not operating Operation in both directions Cloc kwise operation Counterclockwise operation The output of the Switch will be changed, regardless of which direction the lever is pushed. p The output of the Switch will only be changed when the lever is pushed in one direction. Loosen the Allen-head bolt.

Operation of Fork Lever Locks A Switch with a Fork Lever Lock is constructed so that the dog pushes the lever to invert the output and this inverted state is maintained even after the dog moves on. If the dog then pushes the lever from the opposite direction, the lever will return to its original position. Adjusting the Length of the Rod or Lever The length of the rod or lever can be adjusted by loosening the Allen-head bolt. Adjustable Roller Levers: (WLCA12-N, WLCA12-2-N, WLCA12-2N-N, WLG12-N) Adjustable rod lever: (WLCL-N, WLCL-2-N, WLCL-2N-N, WLGL-N, WLCAL4-N) Selecting the Roller Position There are four types of Switches with Fork Lever Locks for use depending on the roller position. Fork lever lock: (WLCA32-4@-N) An explanation of the operation of fork lever locks is provided after this table. Item Applicable models and Actuators Details Loosen this Allen-head bolt and adjust the length of the rod. Adjustment range radius: 25 to 89 mm Adjustable Roller Levers: Adjustable Rod Levers: Loosen this Allen-head bolt and adjust the length of the lever. Adjustment range radius: 24 to 140 mmWLCA32-41-N WLCA32-43-N WLCA32-42-N WLCA32-44-N NC terminal: ON NO terminal: ON NO terminal: ON Example

Connectors (SC Series) Cabtire cables and flexible tubes with various diameters are used to connect machine tools and controllers with Limit Switches. To ensure the watertightness of the edges of the conduits, use an SC Connector that is suitable for the external diameter of cable and model of Limit Switch. Connector for Cabtire Cable Note: Please use sealling tape with SC Connectors. SC-1M to SC-5M, however, are provided with an O-ring (NBR) and therefore seal ing tape is not necessary to ensure a proper seal. Simple Connectors (Not Suitable for Locations Subject to Oil or Water) Note: Simple connector are made of resi n. If more sealing capability is required, use one of SC-1M to SC-5M, which have metal casings. Models marked with an asterisk (*) however, can only be used with resin connectors. Conduit Applicable cable Inner diameter (D) of seal rubber External diameter of cable Model Applicable modelMin. Max. JIS B 0202 G½ Cabtire cable (general- purpose) 7 mm 5.5 mm 7.5 mm SC-1M WL-N, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 9 mm 7.5 mm 9.5 mm SC-2M 12.5 mm 11 mm 13 mm SC-3M 14 mm 12 mm 14 mm SC-4M 11 mm 9 mm 11 mm SC-5M Cabtire cable (anti- corrosive) 7 mm 5.5 mm 7.5 mm SC-21 9 mm 7.5 mm 9.5 mm SC-22 12.5 mm 11 mm 13 mm SC-23 14 mm 12 mm 14 mm SC-24 11 mm 9 mm 11 mm SC-25 ½-14NPT Cabtire cable 7 mm 5.5 mm 7.5 mm SC-1PT D4A-@N 9 mm 7.5 mm 9.5 mm SC-2PT 12.5 mm 11 mm 13 mm SC-3PT 14 mm 12 mm 14 mm SC-4PT 11 mm 9 mm 11 mm SC-5PTConduit Applicable cable Inner diameter (D) of seal rubber External diameter of cable Model Applicable modelMin. Max. JIS B 0202 G½ Cabtire cable 10.6 mm 8.5 mm 10.5 mm SC-P2 WL-N, D4A-@N, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2 Pg13.5 9.6 mm 7.5 mm 9.5 mm SC-P3 WL@-G-N JIS B 0202 G½ 9 mm 7.5 mm 9 mm SC-6 WL-N, D4A-@N, D4N *, D4N-@R *, D4B-@N, ZE, ZV, ZV2, XE, XV, XV2

Dimensions and Structure (Unit: mm) Connectors for Cabtire Cable As for models without an O-ring, please use sealing tape with SC Connectors. Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm. Simple Connectors (Not Suitable for Locations Subject to Oil or Water) Note: Dimensions not shown in the above diagrams have a variation of ±0.4 mm. * Diameter of Part Marked with Asterisk Model Inner diameter (D) of sealed rubber Internal diameter (E) of washer Applicable cable SC-21, -1M, -1PT 7 mm 10.4 mm 5.5 to 7.5-mm dia. SC-22, -2M, -2PT 9 mm 13.2 mm 7.5 to 9.5-mm dia. SC-23, -3M, -3PT 12.5 mm 14.6 mm 11 to 13-mm dia. SC-24, -4M, 4PT 14 mm 14.6 mm 12 to 14-mm dia. SC-25, -5M, -5PT 11 mm 13.2 mm 9 to 11-mm dia. SC-6 9 mm 10 mm 7.5 to 9-mm dia. 14 dia. 14.6 dia. 27.729.3 *E 15 4.8 (34) JIS B 0202 G½ Sealing rubber (nitrile rubber) Connector (brass and nickel plating) Washer (stainless steel) Ball head lock nut (brass and nickel plating) Metal Models without O-ring SC-21 to 25 3029.3 15 5 9 14 dia. 14.6 dia. (34) JIS B 0202 G½ Sealing rubber (nitrile rubber) Sealing rubber (nitrile rubber) Connector (zinc die-cast and zinc plating) Washer (stainless steel) Ball head lock nut (zinc die-cast and zinc plating) Metal Models with O-ring SC-1M to 5M 27.729.3 14 dia. 14 dia. 14.6 dia. (39) ½-14NPT Sealing rubber (nitrile rubber) Connector (zinc die-cast and zinc plating) Washer (stainless steel) Ball head lock nut (zinc die-cast and zinc plating) Metal Models without O-ring ½-14NPT (U.S.-standard screws) SC-1PT to 5PT 25.4 15 1 4.5 10.6 dia.12.6 dia. 18 dia.18 dia. JIS B 0202 Hexagonal nut (polyacetal resin) Conduit washer (ferrous metal and zinc plating) Ring (chloroprene rubber) Resin Models SC-P2 23.5 15.5 14 . 5 Pg13.5 9.6 dia.12 dia. 18 dia.18 dia. Hexagonal nut (polyacetal resin) Conduit washer (ferrous metal and zinc plating) Ring (chloroprene rubber) Resin Models Pg13.5 SC-P3 22.5 9 5 (30.6) Ball head lock nut (polyacetal resin) Sealing rubber (nitrile rubber) Connector (polyacetal resin) M20 × 1.5 Washer (ferrous metal and zinc plating) Resin Models SC-6

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABL Y MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buy er Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with an y electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY , NEGLIGENCE OR STRICT LIABILITY . Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THA T THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERL Y RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.

Authorized Distributor: In the interest of product improvement, specifications are subject to change without notice. Cat. No. C147-E1-02 Printed in Japan 0714 (1013) © OMRON Corporation 2013-2014 All Rights Reserved. OMRON Corporation Industrial Automation Company OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200

Hoffman Estates, IL 60169 U.S.A Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Contact: www.ia.omron.com Tokyo, JAPAN OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road,

PuDong New Area, Shanghai, 200120, China CSM_2_1_0714 Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200