WLH60 BANNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

Banner's WLH60 High Temperature Lights are engineered to withstand harsh, extreme temperature environments, making it the first choice for a machine lighting solution. A conservative mechanical design protects against liquid ingress and state-of-the-art LED technology delivers best of class brightness. Choose between a durable polycarbonate window or a borosilicate glass (BSG) option featuring enhanced chemical and thermal resistance. This smart industrial lighting solution also features an energy efficient eco-mode dimming state to tailor the lumen levels and power consumption to the applications.

  • Approved for use in environments up to 100 °C (212 °F)
  • Rugged and durable for harsh environments
  • Oil, chemical, and water resistant with IEC IP67, JIS C IP68G, and DIN IP69K ratings
  • Easy to install with a wide variety of mounting solutions
  • Highly resistant to vibration and shock Models WLH60 WindowLength (mm)LED ColorCascadableFamily X = Non-cascadable W = Cool White 340 640 Blank = Polycarbonate G = Borosilicate Glass X W 340 Construction B B = Black E-Coated Aluminum GUID-1CB71FE6-0E8B-4A9A-9ABD-6223768AA141 Connection (All Models): 2 m (6.5 ft) integral FEP cable The following caution applies to white LED models: CAUTION: Risk Group 2: Possibly hazardous optical radiation emitted from this product. Do not stare at the operating lamp. May be harmful to the eyes. Risk Group 2 (RG 2) products generally do not pose a realistic optical hazard if aversion responses limit the exposure duration or where lengthy exposures are unrealistic. - IEC 62471 Wiring Diagram 21 - 28 V dc Wire Color Connection 1 - Brown 21 V dc to 28 V dc 3 - Blue dc common 4 - Black Connect to 21 V dc to 28 V dc for 50% intensity. For 100% intensity, leave the black wire floating or connected to common. WLH60 High Temperature LED Light Original Document 202832 Rev. B

23 February 2018

21 V dc to 28 V dc

Figure 1. WLH60 (340 mm) Base Mount Side Exit Model

Figure 2. WLH60 (640 mm) Base Mount Side Exit Model

All measurements are listed in millimeters, unless noted otherwise. LMBWLC60F

  • Set of two flat brackets
  • 300 series stainless steel
  • Includes M6 flathead screws for mounting to light
  • Clearance for M6 or 1/4-20 mounting hardware LMBWLC60RA
  • Set of two right-angle brackets
  • 300 series stainless steel
  • Includes M6 buttonhead screws for mounting to light
  • Clearance for M6 or 1/4-20 mounting hardware LMBWLC60MAG
  • Magnetic mounting kit (set of two)
  • Two inch magnets
  • Mounting hardware included LMBWLC60RAS
  • Pair of two swivel mount, right-angle brackets
  • 300 series stainless steel
  • Includes hardware for mounting to light LMBWLC60B340
  • Plate for sealing the cavity on the back of the 340 mm models
  • 300 series stainless steel
  • Includes hardware for mounting to the light 10 x Ø762 393 12 ACC-WLC60-340-GSK-FDA-1
  • Blue FDA-approved silicone gasket
  • Thickness: 1.6 mm

6 X Ø7

1.6 340 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. WLH60 High Temperature LED Light © Banner Engineering Corp. All rights reserved