WLB92_V03 BANNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

advanced LED lighting technology to provide a high-quality and maintenance free industrial lighting solution. dimming units (see Accessories). WLB92 (AC) Daylight White and Warm White models come with a five year, limited warranty. detalles del uso adecuado, aplicaciones, advertencias, y las instrucciones de instalación de estos dispositivos. utilisation correcte, les applications, les notes de sécurité et les instructions de montage. Figure 1. Mounting the luminaire to the surface mount brackets removing, or servicing luminaire. and any applicable local code requirements. To mount the WLB92 Industrial LED Light Bar, follow these steps.

22 August 2019

  1. Remove luminaire from packaging and inspect for damage before installing. 2. Locate the supplied surface mount brackets. (For suspended installation, refer to the separate hanging bracket kit and instructions.) 3. Insert the screws into the bracket and then screw on the t-nuts. Attach bracket assembly to luminaire housing as shown. Fully tighten the screws to lock in place. 4. Place the light in the mounting location and mark the positions of the bracket mounting holes. 5. Drill the holes and use the appropriate screws to secure the luminaire to the mounting location. CAUTION: To Reduce the Risk of Fire. Do not install the 550 mm models in a compartment smaller than 305 mm by 305 mm by 675 mm. Do not install the 1100 mm models in a compartment smaller than 305 mm by 305 mm by 1350 mm. Wiring the WLB92 Industrial LED Light Bar Follow these steps to wire your WLB92 Industrial LED Light Bar AC Conduit models. Pull latch out to release or insert wire Remove access cap 1/2” Trade Size Knockouts Wiring Chamber 1. Loosen the screws to remove the access cap from the wiring chamber. 2. Connect the power.  To connect the power from the back of the luminaire, remove the knockout from the back of the access cap and install either 1/2-inch conduit or an AC power cord with strain relief.  To connect the power from the side of the luminaire: remove the knockout from the side of the access cap and install either 1/2-inch conduit or an AC power cord with strain relief on the luminaire wires.  If using rigid conduit, the conduit hub/connector must be approved for use in dry or damp locations and must be connected to the conduit before the hub/connector is connected to the luminaire. 3. Pull the luminaire wires out of the wiring chamber, then pull the field wires through the knockouts and out of the wiring chamber. 4. Lift the latch a full 90° on the unused terminal block locations and make the following electrical connections: a) Connect the green/yellow luminaire wire to the AC ground power wire b) Connect the white luminaire wire to the AC neutral power wire c) Connect the black luminaire wire to the AC line power wire d) If using 0–10 V analog dimming, connect the purple luminaire wire to the positive dimming wire e) If using 0–10 V analog dimming, connect the gray luminaire wire to the negative dimming wire 5. Close the latches on each terminal block when you have finished wiring, and push all wires back into the wiring chamber. 6. Re-attach the access cap to the wiring chamber. 7. Repeat steps 1 through 5 on other end of the luminaire if you are connecting to more than one luminaire in a continuous run. Wiring Diagram Diagram Wire Connection N L Dim (+) Dim (-) N L Dim (+) Dim (-) L - Black Line/Hot N - White Neutral - Green/Yellow Earth ground Dim (+) - Purple 0–10 V dc analog dimming Dim (-) - Gray Return analog dimming WLB92 Industrial LED Light Bar (AC Conduit) 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 183985 Rev. I

Specifications Supply Voltage Nominal voltage: 120 V ac to 277 V ac, 60 Hz in North America Nominal voltage: 100 V ac to 277 V ac, 50/60 Hz outside North America Power factor: > 0.95 at 120 V ac and > 0.90 at 277 V ac Total harmonic distortion (THD): < 20% See electrical characteristics on product label Supply Current Lighted Length (mm) Max. Current Draw (A) at

90 V ac

Typical Current Draw (A)

120 V ac 230 V ac 277 V ac

550 0.425 0.270 0.145 0.135 1100 0.850 0.540 0.285 0.250 Supply Protection Circuitry Protected against transient voltages Dimming Compatible with 0–10 V analog LED dimming, dimmable to 10% intensity Compatible dimmers are listed in the Accessories section. Construction Anodized aluminum housing, polycarbonate window and end caps, and stainless steel mounting brackets Spacing Criterion Vertical: 1.20 Horizontal: 1.32 Mounting Surface mount brackets included (2) Compatible with integral 45 mm aluminum framing mounting slots Several optional mounting brackets available (see Accessories) Connections 1/2-inch trade size conduit knockout Environmental Rating IEC IP40 Light Characteristics Daylight White and Warm White Efficacy: 110 lumens/watt typical at 120 V ac at 25 °C (77 °F) CRI: 82, typical Color Dominant Wavelength (nm) or Color Temperature (CCT) Lighted Length Lumens (Typical at 25 °C) 550 mm 1100 mm Daylight White

5000 K (±300 K) 3510 7150

(+225 K, -125 K) 3510 7150 Green 525 nm 1430 2975 Red 625 nm 745 1545 Yellow 590 nm 620 1295 Blue 470 nm 405 840 LED Lifetime Lumen Maintenance - L70 When operating within specifications, output will decrease less than 30% after 50,000 hours. Test Data LM-79, LM-80, TM-21 Operating Temperature for 550 mm Lighted Length Models Surface Mount Installation: –35 °C to +50 °C (–31 °F to +122 °F) for 24 hours per day for 5 years of operation Hanging Installation (> 0.5 m from ceiling): –35 °C to +50 °C (–31 °F to +122 °F) for 24 hours per day for 5 years of operation Operating Temperature for 1100 mm Lighted Length Models Surface Mount Installation: –40 °C to +45 °C (–40 °F to +113 °F) for 16 hours per day for 5 years of operation; or –40 °C to +35 °C (–40 °F to +95 °F) for 24 hours per day for 5 years of operation Hanging Installation (> 0.5 m from ceiling): –40 °C to +50 °C (–40 °F to +122 °F) for 16 hours per day for 5 years of operation; or –40 °C to +45 °C (–40 °F to +113 °F) for 24 hours per day for 5 years of operation Storage Temperature Vibration and Mechanical Shock Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC 60068-2-6 Shock: 5G 11 ms duration, half sine wave per IEC 60068-2-27 Application Notes When connecting continuous run/cascadable lights in series, it is important not to exceed maximum current limitations of 14 AWG, 75 °C wire, in accordance with the National Electrical Code (NEC) and any applicable local code requirements. Certifications Spacing Criteria (SC) The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between fixtures). Luminaire Spacing = SC × Height to Illuminated Plane The mounting height is the distance from the fixture to the surface you are lighting. Performance Curves 550 mm Models - Daylight White and Warm White 180° CD (candela) 1100 917 733 550 367 183 183 367 550 733 100 lux 75 lux 50 lux 40 lux 30 lux 20 lux Mount height of 3 meters (3 m) 10 lux 5 lux 917 1100 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30° 20°10°0° Polar Candela Distribution Isolux Pattern Center Beam (lux) 3,630 lux 0.5 m 1.0 m 1.5 m 2.0 m 2.5 m 3.0 m Vertical Spread: 94.2° Horizontal Spread: 133.6° 1.08 m 2.33 m 2.15 m 4.67 m 3.23 m 7.00 m 4.30 m 9.33 m 1,117 lux 496 lux 279 lux 5.38 m 11.67 m179 lux 6.45 m 14.00 m124 lux Beam Width (m) Illuminance at a Distance Vert. Horiz. 0 m 0 m 3 6 Vertical Angle: 0° Vertical 90° Horizontal 50% max. candela WLB92 Industrial LED Light Bar (AC Conduit) P/N 183985 Rev. I www.bannerengineering.com - Tel: + 1 888 373 6767 3

1100 mm Models - Daylight White and Warm White 180° CD (candela) 2200 1833 1467 1100 733 367 367 733 1100 1467 200 lux 150 lux 100 lux 75 lux 50 lux 25 lux Mount height of 3 meters (3 m) 10 lux 5 lux 1833 2200 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30° 20°10°0° Polar Candela Distribution Isolux Pattern Center Beam (lux) 5,060 lux 0.5 m 1.0 m 1.5 m 2.0 m 2.5 m 3.0 m Vertical Spread: 96.7° Horizontal Spread: 132.3° 1.12 m 2.26 m 2.25 m 4.53 m 3.37 m 6.79 m 4.50 m 9.06 m 1,870 lux 932 lux 524 lux 5.62 m 11.32 m335 lux 6.74 m 13.58 m233 lux Beam Width (m) Illuminance at a Distance Vert. Horiz. 0 m 0 m 3 6 Vertical Angle: 0° Vertical 90° Horizontal 50% max. candela Dimensions 104 [4.1] 97 [3.8] [1.8 ] 22.2 [0.88] Model L1 L2 Accessories Brackets LMBWLB92  Standard bracket that ships with the WLB92 light  Stainless steel  Includes two surface mount brackets, four screws, and four t-nuts 4 x Ø7 9.7 150 25.4 LMBWLB92CLIP  Snap clip allows for tool-less installation  Stainless steel  Includes four snap clips, four screws, and two insulator caps Ø6.5 WLB92 Industrial LED Light Bar (AC Conduit) 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 183985 Rev. I

 Hanging bracket kit allows for suspended installation  Includes two hanging bracket assemblies, four screws, four t-nuts, and two 15-24 mm cables 152 - 1524 (adjustable) 2X M6 BHCS LMBWLB92RAS  Swivel brackets allow for 180° of movement in seven fixed positions  Stainless steel  Includes two swivel bracket assemblies, eight screws, and four t-nuts 2 x Ø7 LMBWLB92S  Surface mount brackets allow for mounting at the end of the light  Stainless steel  Includes two end brackets, four screws, and four t-nuts 4 x Ø7 105 9.7 Dimmers Dimmers with Full Dimming Range: Dimmers with Limited Dimming Range: Lutron Diva Family DVST-XX DVSCSTV-XX Lutron Nova T Family NTSTV-DV-XX Lutron Maestro Family (dimmer with sensor) MS-Z101-XX Leviton Illumatech Family IP710-LFZ Leviton Renoir II Family AWSMT-7DW AWSMG-7DW AWRMG-7DW Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for five years on daylight white and warm white models and one year on all other models following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. FCC Part 15 and CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the manufacturer. Mexican Importer David Alfaro Siqueiros 103 Piso 2 Valle oriente San Pedro Garza Garcia Nuevo Leòn, C. P. 66269 81 8363.2714 WLB92 Industrial LED Light Bar (AC Conduit) © Banner Engineering Corp. All rights reserved