Banner's WLB92 is a very bright LED fixture/luminaire that features an even light output for a no glare 'glow'. The WLB92 series is designed for a wide variety of environments and applications, including but not limited to work stations, machine lighting, and low bay lighting. The WLB92 uses advanced LED lighting technology to provide a high-quality and maintenance free industrial lighting solution. Increase worker productivity and ergonomics with bright, high-quality, uniform light Exceptionally energy efficient for overall cost savings Durable light stands up to your environment with a rugged metal housing and shatter-resistant window Easy installation with surface mount brackets or a choice of snap, swivel, or hanging brackets Intensity can be controlled from 0% to 100% using Pulse Width Modulation (PWM) dimming Rated for use at 24 V dc WLB92 Industrial LED Light Bars are available in several configurations including different lengths, switches, dimming capabilities, and cord options. See Accessories (p. 4). To view or download the latest technical information about this product, including specifications, dimensions, accessories, and wiring, see www.bannerengineering.com. For PWM dimming, use with the LC65 Dimmer Module. For more information, refer to the LC65 LED Dimmer Module datasheet, p/n 177086. Important: Lea el siguiente instructivo antes de operar el luminario. Por favor descargue desde www.bannerengineering.com toda la documentación técnica de los WLB92 Industrial LED Light Bar (DC), disponibles en múltiples idiomas, para detalles del uso adecuado, aplicaciones, advertencias, y las instrucciones de instalación de estos dispositivos. Important: Lisez les instructions suivantes avant d'utiliser le luminaire. Veuillez télécharger la documentation technique complète des WLB92 Industrial LED Light Bar (DC) sur notre site www.bannerengineering.com pour les détails sur leur utilisation correcte, les applications, les notes de sécurité et les instructions de montage. Models Family WLB92 Connector Blank = 2 m Integral Cable Q = Integral 4-pin M12 Quick Disconnect (QD) fitting * * QD models require mating cordset PB = Switch, Dimming knob PWM = Dimmable via Pulse Width Modulation Control 550 1100 Lighted Length (mm) X = Non- Cascadable Blank = Daylight White WW = Warm White G = Green R = Red Y = Yellow B = Blue Cascadable X LED Color
550 PB Q
Pin 1 brown – 24 V dc Pin 3 blue – dc common Pin 4 black – Pulse width modulation (PWM) input (PWM models only) Pin 2 white – Not Used WLB92 Industrial LED Light Bar (DC) Original Document 183983 Rev. F
22 August 2019
Note: For maximum intensity, leave the black wire floating or connected to common. There is no black wire present in the models with a dimming knob. Specifications Supply Voltage Operating Voltage: 24 V dc (± 10%) See electrical characteristics on product label Use only with a suitable Class 2 power supply (North America) Use only with a suitable Class III SELV power supply (Europe) Supply Current Lighted Length (mm) Max Current Draw (A) Typical Current Draw at 24 V dc (A) 550 1.75 1.325 1100 3.50 2.650 Supply Protection Circuitry Protected against reverse polarity and transient voltages Switch/Dimming Knob (some models) On/Off Switch and dimming knob, dimmable to 0% intensity Pulse Width Modulation (PWM) Dimming (some models) Frequency: Up to 1000 Hz Voltage: 12 V dc to 24 V dc Current: 4 mA maximum Compatible with the LC65 Dimmer Module. For more information, refer to the LC65 LED Dimmer Module datasheet, p/n 177086. Construction Anodized aluminum housing, polycarbonate window and end caps, and stainless steel mounting brackets Spacing Criterion Vertical: 1.20 Horizontal: 1.32 Light Characteristics Daylight White and Warm White Efficacy: 110 lumens/watt typical at 24 V dc at 25 °C (77 °F) CRI: 82, typical Color Dominant Wavelength (nm) or Color Temperature (CCT) Lighted Length Lumens (Typical at 25 °C) 550 mm 1100 mm Daylight White
5000 K (±300 K) 3510 7150
3000 K (+225 K, -125 K) 3510 7150
Surface mount brackets included (2) Compatible with integral 45 mm aluminum framing mounting slots Several optional mounting brackets available (see Accessories (p. 4)) Connections Integral 4-pin M12/Euro-style quick disconnect connector (4-pin connecting cordset required for QD models); or 2 m (6.5 ft) integral cable Environmental Rating IEC IP40 Operating Temperature
550 Lighted Length Models: Light output begins to decrease above 65 °C (149 °F);
light output is approximately 90% of maximum intensity at 70 °C (158 °F).
1100 Lighted Length Models: Light output begins to decrease above 45 °C (113 °F);
light output is approximately 75% of maximum intensity at 60 °C (140 °F) and 65% of maximum intensity at 70 °C (158 °F). Storage Temperature Vibration and Mechanical Shock Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC 60068-2-6 Shock: 5G 11 ms duration, half sine wave per IEC 60068-2-27LED Lifetime Lumen Maintenance - L70 When operating within specifications, output will decrease less than 30% after 50,000 hours. Test Data LM-79, LM-80, TM-21 Certifications CAUTION: To Reduce the Risk of Fire. Do not install the 550 mm models in a compartment smaller than 305 mm by 305 mm by 675 mm. Do not install the 1100 mm models in a compartment smaller than 305 mm by 305 mm by 1350 mm. Spacing Criteria (SC) The spacing criteria is the fixture-spacing-to-mounting-height ratio and aids in laying out a pattern of fixtures. Multiply the spacing criteria by the mounting height to get the maximum fixture spacing that still provides even illumination (no shadowing between fixtures). Luminaire Spacing = SC × Height to Illuminated Plane The mounting height is the distance from the fixture to the surface you are lighting. WLB92 Industrial LED Light Bar (DC) 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 183983 Rev. F
550 mm Models - Daylight White and Warm White 180° CD (candela) 1100 917 733 550 367 183 183 367 550 733 100 lux 75 lux 50 lux 40 lux 30 lux 20 lux Mount height of 3 meters (3 m) 10 lux 5 lux 917 1100 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30° 20°10°0° Polar Candela Distribution Isolux Pattern Center Beam (lux) 3,630 lux 0.5 m 1.0 m 1.5 m 2.0 m 2.5 m 3.0 m Vertical Spread: 94.2° Horizontal Spread: 133.6° 1.08 m 2.33 m 2.15 m 4.67 m 3.23 m 7.00 m 4.30 m 9.33 m 1,117 lux 496 lux 279 lux 5.38 m 11.67 m179 lux 6.45 m 14.00 m124 lux Beam Width (m) Illuminance at a Distance Vert. Horiz. 0 m 0 m 3 6 Vertical Angle: 0° Vertical 90° Horizontal 50% max. candela 1100 mm Models - Daylight White and Warm White 180° CD (candela) 2200 1833 1467 1100 733 367 367 733 1100 1467 200 lux 150 lux 100 lux 75 lux 50 lux 25 lux Mount height of 3 meters (3 m) 10 lux 5 lux 1833 2200 170°160°150° 140° 130° 120° 110° 100° 90° 80° 70° 60° 50° 40° 30° 20°10°0° Polar Candela Distribution Isolux Pattern Center Beam (lux) 5,060 lux 0.5 m 1.0 m 1.5 m 2.0 m 2.5 m 3.0 m Vertical Spread: 96.7° Horizontal Spread: 132.3° 1.12 m 2.26 m 2.25 m 4.53 m 3.37 m 6.79 m 4.50 m 9.06 m 1,870 lux 932 lux 524 lux 5.62 m 11.32 m335 lux 6.74 m 13.58 m233 lux Beam Width (m) Illuminance at a Distance Vert. Horiz. 0 m 0 m 3 6 Vertical Angle: 0° Vertical 90° Horizontal 50% max. candela Dimensions 104 [4.1] [.8] [3.8] [1.8] Models L1 L2 WLB92 Industrial LED Light Bar (DC) P/N 183983 Rev. F www.bannerengineering.com - Tel: + 1 888 373 6767 3
4-Pin Threaded M12/Euro-Style Cordsets (15 ft and Shorter)—Single Ended Model Length Style Dimensions Pinout (Female) MQDC-406 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 1 = Brown 2 = White 3 = Blue 4 = Black MQDC-415 4.57 m (15 ft) MQDC-406RA 1.83 m (6 ft) Right-Angle 32 Typ. [1.26"] 30 Typ. [1.18"] ø 14.5 [0.57"] M12 x 1 MQDC-415RA 4.57 m (15 ft) Brackets LMBWLB92 Standard bracket that ships with the WLB92 light Stainless steel Includes two surface mount brackets, four screws, and four t-nuts 4 x Ø7 9.7 150 25.4 LMBWLB92CLIP Snap clip allows for tool-less installation Stainless steel Includes four snap clips, four screws, and two insulator caps Ø6.5 LMBWLB92HK5 Hanging bracket kit allows for suspended installation Includes two hanging bracket assemblies, four screws, four t-nuts, and two 15-24 mm cables 152 - 1524 (adjustable) 2X M6 BHCS LMBWLB92RAS Swivel brackets allow for 180° of movement in seven fixed positions Stainless steel Includes two swivel bracket assemblies, eight screws, and four t-nuts 2 x Ø7 LMBWLB92S Surface mount brackets allow for mounting at the end of the light Stainless steel Includes two end brackets, four screws, and four t-nuts 4 x Ø7 105 9.7 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. WLB92 Industrial LED Light Bar (DC) 4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 183983 Rev. F
FCC Part 15 and CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the manufacturer. Mexican Importer David Alfaro Siqueiros 103 Piso 2 Valle oriente San Pedro Garza Garcia Nuevo Leòn, C. P. 66269 81 8363.2714 WLB92 Industrial LED Light Bar (DC) © Banner Engineering Corp. All rights reserved