WL50-2 BANNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 4

Technical content

  • Intensity can be controlled from 15 to 95% using Pulse Width Modulation (PWM) on an input control wire
  • Designed for enclosure or area lighting
  • Use with an optional flex arm mount for adjustable, industrial task lighting
  • Illuminates a large area with an even pattern of light
  • Standard or push-button models available
  • Flat-mount or 30 mm base-mount models available
  • Rugged, sealed polycarbonate housing rated to IP69K (standard models) or IP67 (push- button models)
  • Low-profile design with several mounting options
  • 12 to 30 V dc operation
  • Cabled and quick-disconnect models available
  • Low power consumption; less than 3 watts Models Flat-mount models include a 48 mm (1.9 in) circular velcro mounting kit for easy mounting with no additional hardware. Model1 Push-Button Mounting Style Input WL50F-2PWM Standard (no push-button) Flat-mount 12 to 30 V dc WL50-2PWM 30 mm base-mount For PWM dimming, use with the LC65 Dimmer Module. For more information, refer to the LC65 LED Dimmer Module datasheet, p/n 177086. For more information about using the dimmer module, refer to Wiring on page 1. Wiring Pins Color Connection 1 brown 12 to 30 V dc 3 blue dc common 4 black Pulse width modulation (PWM) input; for maximum intensity, connect the black wire to 12 to 30 V dc 2 white Not used IN OUT V+ V+V− V− P −Power supply12–30 V dc Common PWM Input LED Light1 13 3 +V dc For standard polarity PWM dimming, use with the LC65P2T dimming module. Use the LC65P1T or LC65P1Q5 dimming modules for opposite polarity dimming. 1 Only standard 2 m (6.5 ft) cable models are listed.
  • To order the 9 m (30 ft) cable models, add the suffix W/30 to the model number , for example, WL50F-2PWM W/30.
  • To order the 4-pin Euro-style Integral QD connector models, add the suffix Q to the model number, for example, WL50F-2PWMQ.
  • To order the 150 mm (6 in) 4-pin Euro pigtail QD models, add the suffix QP to the model number , for example, WL50F-2PWMQP.
  • A model with a QD requires a mating cordset. WL50-2 LED Work Light - PWM Dimmable Original Document 179499 Rev. C

14 December 2018

Supply Voltage and Current

12 V to 30 V dc (Use only with suitable Class 2 power supply)

Max. current at –40 °C (–40 °F): 233 mA at 12 V dc 110 mA at 24 V dc 90 mA at 30 V dc Max. Input Power: 2.8 watts Pulse Width Modulation (PWM) Frequency: Up to 300 Hz Voltage: 12 V to 30 V dc Current: 3 mA max. Power-Up Response Time Light On: 1 ms (max.) for models without push-button Construction Polycarbonate housing; nickel-plated QD connector or PVC-jacketed cable Environmental Rating Standard models: IEC IP67, IP69K per DIN 40050 Push-Button Models: IEC IP67 Operating Conditions Light Characteristics Color temperature (CCT): 6000–7000K Color: Cool white Lumen output at 25 °C (77 °F) typical: 185 lumens Luminous efficacy at 25 °C (77 °F) typical: 72 lumens per watt Lux (typical): at 0.5 m (1.6 ft): 350 lux at 1.0 m (3.3 ft): 88 lux at 2.0 m (6.6 ft): 22 lux Connections Integral 4-pin Euro-style QD, 150 mm (5.9 in) PVC pigtail with QD, or 2 m (6.5 ft) integral cable, depending on model Certifications UL Recognized for easy installation in control cabinets Intensity Distribution Candela 20 20040 4060 6080 80 30°30° 60°60° 90°90° Dimensions - Flat Mount Models 50 mm dia [1.95”] 35 mm [1.38”] 5 mm [0.20”] 2 x R6 [0.24”]20 mm [0.79”] 40 mm [1.57”] 76 mm [3”] M12 x 1 16 mm [0.63”] 9.3 mm [0.37”] 23.1 mm [0.91”] 17.5 mm [0.69”]11.5 mm [0.45”] WL50-2 LED Work Light - PWM Dimmable 2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 179499 Rev. C

Dimensions - 30 mm Base Mount Models 50 mm dia [1.95”] M30 x 1.5-6g 1/2”-14 NPSM M12 x 1-6g 16.5 mm [0.65”] 36.5 mm [1.44”]47.5 mm [1.87”] Accessories Cordsets 4-Pin Threaded M12/Euro-Style Cordsets Model Length Style Dimensions Pinout (Female) MQDC-406 1.83 m (6 ft) Straight 44 Typ. ø 14.5 M12 x 1 1 = Brown 2 = White 3 = Blue 4 = Black MQDC-415 4.57 m (15 ft) MQDC-430 9.14 m (30 ft) MQDC-450 15.2 m (50 ft) MQDC-406RA 1.83 m (6 ft) Right-Angle 32 Typ.[1.26"] 30 Typ.[1.18"] ø 14.5 [0.57"] M12 x 1 MQDC-415RA 4.57 m (15 ft) MQDC-430RA 9.14 m (30 ft) MQDC-450RA 15.2 m (50 ft) WL50-2 LED Work Light - PWM Dimmable P/N 179499 Rev. C www.bannerengineering.com - Tel: + 1 888 373 6767 3

  • Right-angle bracket with curved slot for versatile orientation
  • Clearance for M6 (¼ in) hardware
  • Mounting hole for 30 mm sensor
  • 12-ga. stainless steel

69 A B

C Hole center spacing: A to B=40 Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5 SMB30SC

  • Swivel bracket with 30 mm mounting hole for sensor
  • Black reinforced thermoplastic polyester
  • Stainless steel mounting and swivel locking hardware included B A Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 SMB30MM
  • 12-ga. stainless steel bracket with curved mounting slots for versatile orientation
  • Clearance for M6 (¼ in) hardware
  • Mounting hole for 30 mm sensor A B C Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1 Flex Arm Mounts
  • For cabled and QD models
  • 457 mm (18 in) long, vinyl coated FLX18-1212 FLX18-F12 FLX18-12M30 FLX18-DM30 FLX18-FM30 For base connection measurements, visit www.bannerengineering.com and search for p/n 170238. Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. For patent information, see www.bannerengineering.com/patents. FCC Part 15 and CAN ICES-3 (B)/NMB-3(B) This device complies with part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules and CAN ICES-3 (B)/NMB-3(B). These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the manufacturer. WL50-2 LED Work Light - PWM Dimmable © Banner Engineering Corp. All rights reserved