MODEL: WL40EW2F WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 1/7 http://www.m-system.co.jp/ Wireless I/O WL40F Series WIRELESS GATEWAY Modbus/TCP (Ethernet), Modbus-RTU Transparent 900MHz Band Wireless Device (parent device) 60 (2.36) [260 (10.24)] 155 (6.10) mm (inch) MODEL: WL40EW2F-[1][2]

ORDERING INFORMATION

  • Code number: WL40EW2F-[1][2] Specify a code from below for each [1] and [2]. (e.g. WL40EW2F-R/E/Q)
  • Specify the specification for option code /Q (e.g. /C01) [1] POWER INPUT DC Power S: 12 V DC (Operational voltage range 12 V ±10 %, ripple 10 %p-p max.) R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [2] OPTIONS (multiple selections) Antenna /S: Sleeve antenna /E: Rooftop antenna Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating FUNCTIONS & FEATURES This unit
  • Incorporates 900MHz band wireless module with RS-485 transparent type, which can communicate using Modbus- RTU protocol.
  • Converts Modbus-RTU (RS-485) and Modbus/TCP (Ethernet) protocol.
  • Incorporates the module compliant with FCC Part 15, and can be used only in the United States.

RELATED PRODUCTS

For related products of wireless device, refer to M-System's web site. Maintenance software Maintenance console: MH920 Console International (model: MH920CI) (OKI) (Maintenance software is downloadable at M-System’s web site.) Coaxial cable

  • 7.5 m extension cable for rooftop antenna (model: CX- SAC0SAD0Q0750) (OKI) Using 7.5 m coaxial cable for extension decreases transmission distance. GENERAL SPECIFICATIONS Connection Wireless network: SMA coaxial connector Power supply: Tension clamp (Front Twinconnection) Applicable wire size: 0.2 - 2.5 mm2, stripped length: 10 mm Ethernet: RJ-45 Modular Jack Maintenance: Mini USB type B female connector Housing material: Flame-resistant resin Isolation: Power supply to Ethernet to FE1 to antenna connector Switch: IP Reset Refer to the instruction manual for details. Indicator LED: Power COMMUNICATION ■ Common spec. Modbus protocol Protocol: Modbus/TCP Data: RTU (Binary) Port No.: 502 Max. number of socket connections: 8 IP address: 192.168.0.1 (factory setting); Selectable with web browser ■ Ethernet Communication Standard: IEEE 802.3u Transmission: 10BASE-T, 100BASE-TX Baud rate: 10/100 Mbps (Auto Negotiation function)

MODEL: WL40EW2F WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 2/7 http://www.m-system.co.jp/ Transmission media: 10BASE-T (STP, Category 5) 100BASE- TX (STP, Category 5e) Max. length of fieldbus segment: 100 meters Ethernet indicator LED: Link, Link100 WIRELESS SPECIFICATIONS Communication Standard: IEEE 802.15.4g Frequency: 900MHz band (902 - 928 MHz) Max. Transmission power: 20mW Bandwidth: 400 kHz Modulation: GFSK Baud rate: Max. 100 kbps Channels: 1 to 43ch Security: 128bit AES Indicator LEDs: 920Run, 920Link Number of child devices: Max. 100 Protocol: Modbus-RTU Communication module: Coordinator module incorporated (Oki Electric Industry Co., Ltd. ) Radio parameters setting: by Web browser Max. transmission distance (optical): Approx. 1 km Antenna

  • Sleeve antenna (Model: MH920-ANT-F (S)) Indoor use Non-waterproof Non-directional Gain: 3.0dBi max.
  • Rooftop antenna (Model: MH920-ANT-F (R)) Outdoor/indoor use Cable length: 2.5 m Waterproof performance: IPx6 (except connector) Non-directional Gain: 2.0dBi max. INSTALLATION Current consumption:

24 V DC: ≤ 90 mA

12 V DC: ≤ 170 mA

Operating temperature: -20 to +60°C (-4 to +140°F) Operating humidity: 10 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: DIN rail Weight Unit: Approx. 270 g (0.60 lb) Sleeve antenna (standard): 27 g (0.95 oz) Rooftop antenna: 52 g (1.83 oz) PERFORMANCE Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (power input to Ethernet or FE1 to antenna connector) STANDARDS & APPROVALS Module conforming to FCC Part 15 incorporated

MODEL: WL40EW2F WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 3/7 http://www.m-system.co.jp/ WEB BROWSER SETTING With Web browser, settings shown below are available. Refer to the operating manual (EM-9080-B) for detailed settings. ■ TCP / IP SETTING ITEM SETTING RANGE DEFAULT ■ MODBUS / TCP SETTING ITEM SETTING RANGE DEFAULT Port 1 – 65535 502 Modbus exception response Not return 06 (BUSY), 0B (ERROR) / Return 06 (BUSY), 0B (ERROR) Return 06 (BUSY), 0B (ERROR) Communication timeout 1 – 60 (min.) 1 (min.) ■ WIRELESS SETTING ITEM SETTING RANGE DEFAULT PAN ID (group number) 0000 – FFFE (hexadecimal, 4 digits) 0000 Radio channel number 1 – 43ch 1ch Network name English one-byte characters within 16 characters (one-byte space, “-” MH920 (hexadecimal, 32 digits) 0000...0 Pre/f_i x 2000:0000:0000:0000 – 3FFF:FFFF:FFFF:FFFF 2000:0000:0000:0000 Transmitter power output 0.16mW / 1mW / 20mW 20mW Device type in a network, Number of devices in a network Child (/f_i xed), 1 to 30 devices / Child (/f_i xed), 31 to 60 devices / Child (/f_i xed), 61 to 100 devices / Child (/f_i xed) + child (moving) Child (/f_i xed), 1 to 30 devices Set network quality Standard (recommended) / Frequency of route switching and delay (higher) / Frequency of route switching and delay (highest) Standard (recommended) Network join mode V3-compatible mode / Fast join mode V3-compatible mode Packet /f_i ltering None / Y es (polling type) Y es (polling type) Setting mode of short address Range mode: 1 device (max. multi drop number) Range mode: 1 to 4 devices (max. multi drop number) Range mode: 1 to 8 devices (max. multi drop number) Range mode: 1 to 16 devices (max. multi drop number) Range mode: 1 to 31 devices (max. multi drop number) List mode List mode Retry times before route switching Once / Twice / Three times Three times Short address list setting Short address — MAC address list setting MAC address — Connection refusal list setting MAC address — * For version confirmation of communication module, refer to the operating manual (EM-9080-B).

MODEL: WL40EW2F WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 4/7 http://www.m-system.co.jp/ EXTERNAL VIEW Network Status Indicator LED *Power input defers depending on the power input code you select. Status Indicator LED Antenna Connector Maintenance Connector Connector for Power Input * Power 920Link 920Run CFG 24V NC NC FE1 RJ-45 Modular jack Link Link100 Ethernet IP Reset Reset Switch ■ FRONT VIEW TERMINAL ASSIGNMENTS ■ CONNECTORS FOR POWER INPUT Unit side connector: MSTBV2,5/5-GF-5,08AU (Phoenix Contact) Cable side connector: TFKC2,5/5-STF-5,08AU (Phoenix Contact)

  • Power input code: R (24 V DC) • Power input code: S (12 V DC) 24V NC NC FE1 ID FUNCTION 12V NC NC FE1 ID FUNCTION 24V Power input 24 V 12V Power input 12 V 0V Power input 0 V 0V Power input 0 V NC Not used NC Not used NC Not used NC Not used FE1 Power input earth FE1 Power input earth

MODEL: WL40EW2F WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 5/7 http://www.m-system.co.jp/ MODBUS FUNCTION CODES & SUPPORTED CODES Modbus function codes are shown below. ■ DATA AND CONTROL FUNCTIONS CODE NAME

01 Read Coil Status Digital output from the slave (read/write)

02 Read Input Status Status of digital inputs to the slave (read only)

03 Read Holding Registers General purpose register within the slave (read/write)

04 Read Input Registers Collected data from the /f_i eld by the slave (read only)

05 Force Single Coil Digital output from the slave (read/write)

06 Preset Single Registers General purpose register within the slave (read/write)

15 Force Multiple Coils Digital output from the slave (read/write)

16 Preset Multiple Registers General purpose register within the slave (read/write)

■ EXCEPTION CODES CODE NAME 06 Slave Device Busy Device’s Modbus/TCP request queue is full. 11 Gateway Target Device Failed To Respond Response from 900MHz band wireless device (child) is error, or response timeout occurred. Note: When 900 MHz band wireless device (child) returns an exception code other than the above, the exception code is directly transmit- ted to upper devices.

MODEL: WL40EW2F WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 6/7 http://www.m-system.co.jp/ EXTERNAL DIMENSIONS unit: mm (inch) 105 (4.13) [260 (10.24)] 107 (4.21) 3 (.12) 3 (.12) 45 (1.77) [200 (7.87)] (.79) approx. 2500 (98.4)ø27 (1.06) ø3 (.12) ø1.2 (.05) 36 (1.42) 80 (3.15) 5 (.20) [155 (6.10)] [R165 (6.50)]

  • With sleeve antenna
  • With rooftop antenna DIN RAIL 35mm wide DIN RAIL 35mm wide 8 (.31) Hex.

MODEL: WL40EW2F WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 7/7 http://www.m-system.co.jp/ SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Two-way wireless circuit LED Control Circuit Reset Switch Power Input Maintenance Connector To Other Ethernet Devices * Power input defers depending on the power input code you select. RJ-45 Modular Jack USB Connector Antenna Connector NC NC FE1 24V* Isolation Communication Circuit SYSTEM CONFIGURATION EXAMPLES LAN cable (STP cable) PC Modbus/Master Wireless gateway (model: WL40EW2F) Wireless gateway (model: WL40MW1F) Slave Device Slave Device Slave Device MAX. 31 RS-485 PC side as Modbus/Master communicates with child devices via wireless module using Modbus/TCP and RTU protocol, and also communicates with slave devices in multi drop connection (RS-485). Specifications are subject to change without notice.