WF100 ETC1 | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

2:1 Input Range Efficiency to 85% 300kHz Switching Frequency Overvoltage Protection Remote Disable Six-sided Shield External Output Trim Specification All specifications are typical at 25°C, nominal line & 75% load Intelligent Design Quality Product XPiQ inc. DC/DC Converters Input Input Voltage Range • See Table Input Filter • π Type Output Voltage Accuracy • Single output, ±2% max. Dual + output, ±2% max. Dual - output, ±3% max. Triple 5V, ±2% max. 12V/15V, ±5% max. Voltage Balance Dual Output at full load

  • ±1% max. Transient Response Single, 25% Step Load Change
  • <500µ sec Dual, FL=1/2L±1% Error Band
  • <500µ sec External Trim Adj. Range • ±10% Ripple & Noise • 10mV RMS, max (20MHz BW) 75m V p-p max. Temperature • ±0.02%/°C max. Coefficient Short Circuit • Indefinite Protection Line Regulation Single/Dual Output • ±0.5% max. Triple Output • ±1.0% max. Load Regulation Single/Dual Output • ±1.0% max. Triple Output • ±5.0% max. General Efficiency • See Table Isolation Voltage • 500 VDC min Isolation Resistance • 10 9 ohms min. Switching • 300 kHz Frequency Case Grounding • Capacity Coupled to Input Operating Temperature • -25°C to +100°C Range Storage Temperature • -55°C to +105°C Range Environmental EMI/RFI • Six-sided Continuous Shield Case Temperature • 100°C max Case Material • Black Coated Copper with Non-Conductive Base Dimensions • 2 x 2 x 0.40 inches (50.8 x 50.8 x 10.2 mm) Safety Approvals • UL1950 for U versions only PH: 508 429.9883 FAX: 800 226.2100 Email: sales@xp-iq.com Holliston, MA 01746 USAwww.XP-iQ.com39 021-040 3/5/02 4:04 pm Page 19

OUTPUT VOLTAGE & CURRENT RATINGS WF Model Input Output Output Input Current % Voltage Voltage Current No Load Full Load Efficiency WF100 9-18 VDC 3.3 VDC 5000 mA 30 mA 1860 mA 74 WF101 9-18 VDC 5.0 VDC 5000 mA 30 mA 2675 mA 78 WF102 9-18 VDC 12.0 VDC 2500 mA 30 mA 3050 mA 82 WF103 9-18 VDC 15.0 VDC 2000 mA 30 mA 3050 mA 82 WF104 9-18 VDC ±5.0 VDC ±2500 mA 35 mA 2675 mA 78 WF105 9-18 VDC ±12.0 VDC ±1250 mA 35 mA 3050 mA 82 WF106 9-18 VDC ±15.0 VDC ±1000 mA 35 mA 3050 mA 82 WF107 9-18 VDC 5.0/±12.0 VDC 3500/±310 mA 35 mA 2640 mA 79 WF108 9-18 VDC 5.0/±15.0 VDC 3500/±250 mA 35 mA 2640 mA 79 WF200 18-36 VDC 3.3 VDC 5000 mA 30 mA 920 mA 75 WF201 18-36 VDC 5.0 VDC 5000 mA 30 mA 1336 mA 79 WF202 18-36 VDC 12.0 VDC 2500 mA 30 mA 1525 mA 82 WF203 18-36 VDC 15.0 VDC 2000 mA 30 mA 1525 mA 82 WF204 18-36 VDC ±5.0 VDC ±2500 mA 30 mA 1336 mA 79 WF205 18-36 VDC ±12.0 VDC ±1250 mA 30 mA 1470 mA 85 WF206 18-36 VDC ±15.0 VDC ±1000 mA 30 mA 1470 mA 85 WF207 18-36 VDC 5.0/±12.0 VDC 3500/±310 mA 30 mA 1320 mA 80 WF208 18-36 VDC 5.0/±15.0 VDC 3500/±250 mA 30 mA 1320 mA 80 WF300 36-72 VDC 3.3 VDC 5000 mA 20 mA 460 mA 75 WF301 36-72 VDC 5.0 VDC 5000 mA 20 mA 660 mA 79 WF302 36-72 VDC 12.0 VDC 2500 mA 20 mA 765 mA 82 WF303 36-72 VDC 15.0 VDC 2000 mA 20 mA 765 mA 82 WF304 36-72 VDC ±5.0 VDC ±2500 mA 25 mA 660 mA 79 WF305 36-72 VDC ±12.0 VDC ±1250 mA 25 mA 735 mA 85 WF306 36-72 VDC ±15.0 VDC ±1000 mA 25 mA 735 mA 85 WF307 36-72 VDC 5.0/±12.0 VDC 3500/±310 mA 25 mA 655 mA 80 WF308 36-72 VDC 5.0/±15.0 VDC 3500/±250 mA 25 mA 655 mA 80 Pin Connections Pin Single Output Dual Output Triple Output

1 REMOTE ON/OFF REMOTE ON/OFF REMOTE ON/OFF

2 NO PIN NO PIN NO PIN

3 –VIN –VIN –VIN 4 +VIN +VIN +VIN

5 OUTPUT TRIM OUTPUT TRIM –OUTPUT

6 –OUTPUT –OUTPUT COMMON 7 +OUTPUT COMMON +5V OUTPUT

8 NO PIN +OUTPUT +OUTPUT

Triple Output Loading Table(1) Output Voltage Amperes (Pin No.) Min. (2) Nom. 7+ 5 0 . 5 0 3 . 5 0 8 & 5 +12 or -12 0.10 0.31 8 & 5 +15 or -15 0.10 0.25 Notes: 1. Maximum total power from all outputs is limited to 25 watts but no output should be allowed to exceed its maximum current. 2. Minimum current on each output is required to maintain specified regulation. Dimensions in inches (mm) PH: 508 429.9883 FAX: 800 226.2100 Email: sales@xp-iq.com Holliston, MA 01746 USAwww.XP-iQ.com 40 For optional UL1950 approved product, add suffix “U” to part number. 021-040 3/5/02 4:04 pm Page 20