Technical content

Compact, USB Water-Cooled Laser Power Sensors These compact sensors are particularly useful when space is an issue. They must be water-cooled to achieve the full power rating, and they can also be used air-cooled (stand-alone or mounted to a heat sink) for stand-alone intermittent application of power.

FEATURES

  • Compact designs
  • Use water-cooled or air-cooled
  • 19 mm and 50 mm apertures

APPLICATIONS

  • Medical
  • Scientific
  • Industrial
  • General Laser Power Measurement to 5 kW

Water-Cooled Thermopile USB/RS Sensors to 5 kW Datasheet SPECIFICATIONS PM10-19C PM100-19C PM150-19C PM150-50C Wavelength Range (μm) 0.19 to 11 Power Range (water-cooled) 10 mW to 10 W 300 mW to 100 W 300 mW to 150 W 300 mW to 150 W Maximum Intermittent Power (W) (<5 min.) 5 (air-cooled) 100 20 (air-cooled) 80 (air-cooled) Long-Pulse Joules (J) 0.5 to 10 1 to 100 1 to 150 1 to 150 Noise Equivalent Power (mW) 0.2 1 1 1 Maximum Power Density (kW/cm 2) 6 Maximum Energy Density (mJ/cm 2) 600 (10 ns , 1064 nm) Response Time (sec.) (0% to 95%) Speed-up On Speed-up Off Detector Coating Broadband Detector Element Thermopile Optic None Detector Diameter (mm) 19 19 19 50 Calibration Uncertainty (%) (k=2) ±2 Power Linearity (%) ±1 Spectral Compensation Accuracy (%) ±1.5 Long-Pulse Joules Accuracy (%) ±3 Calibration Wavelength (nm) 10,600 Cooling Method Water/Air (intermittent) Cable Type USB and RS Cable Length (m) 2.5 (USB)/0.3 (RS) Part Number USB RS-232 1168344 1168345 1288940 1168346 1168347 11683481 11683491 1 1 Day Ship program: eligible for next business day shipment. PM100-19CPM10-19C/PM150-19C (shown with PowerMax-RS cable) PM150-50C (shown with PowerMax-RS cable) MECHANICAL SPECIFICATIONS 51 mm (2.0 in.) 51 mm (2.0 in.) Ø19 mm (0.75 in.) 30 mm (1.17 in.) +5VDC Power Input 51 mm (2.0 in.) Adjustable 165 mm to 220 mm (6.5 in. to 8.66 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) Note: Detector Surface is 5.56 mm (0.22 in.) below front face of aperture plate 51 mm (2.0 in.) 89 mm (3.5 in.) Ø50 mm (1.97 in.) 31 mm (1.23 in.) 89 mm (3.5 in.) Adjustable 203 mm to 257 mm (8.0 in. to 10.12 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) Note: Detector Surface is 7.14 mm (0.28 in.) below front face of aperture plate +5VDC Power Input 1/4-20 UNC Female Mounting Threads 51 mm (2.0 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) 89 mm (3.5 in.) 89 mm (3.5 in.) Ø19 mm (0.75 in.) 31 mm (1.23 in.) Note: Detector Surface is 7.2 mm (0.28 in.) below front face of aperture plate Adjustable 189-259 mm (7.44-10.2 in.)

Coherent follows a policy of continuous product improvement. Specifications are subject to change without notice. Coherent’s scientific and industrial lasers are certified to comply with the Federal Regulations (21 CFR Subchapter J) as administered by the Center for Devices and Radiological Health on all systems ordered for shipment after August 2, 1976. Coherent offers a limited warranty for all Thermopile Sensors. For full details of this warranty coverage, please refer to the Service section at www.coherent.com or contact your local Sales or Service Representative. MC-013-21-0M0621 Copyright ©2021 Coherent, Inc. Coherent, Inc.,

5100 Patrick Henry Drive Santa Clara, CA 95054

p. (800) 527-3786 | (408) 764-4983 f. (408) 764-4646 tech.sales@coherent.com www.coherent.com 3/8-16 UNC Female Mounting Threads 256 mm (10.07 in.) 59 mm (2.33 in.) Ø171 mm (6.73 in.) Ø100 mm (3.94 in.) Ø202 mm (7.95 in.) Note: Detector Surface is 19 mm (0.75 in.) below front face of aperture plate 1/4-20 UNC Female Mounting ThreadsAdjustable 189-259 mm (7.44-10.2 in.) Ø50 mm (1.97 in.) 89 mm (3.5 in.) 89 mm (3.5 in.) 31 mm (1.23 in.) 51 mm (2.0 in.) 51 mm (2.0 in.) 76 mm (3.0 in.) Note: Detector Surface is 8 mm (0.32 in.) below front face of aperture plate Water-Cooled Thermopile USB/RS Sensors to 5 kW Datasheet PM150-50XC PM1KX-100/PM5K-100 MECHANICAL SPECIFICATIONS SPECIFICATIONS PM150-50XC PM1KX-100 PM5K-100 Wavelength Range (μm) 0.15 to 1 0.15 to 1 0.25 to 10.6 Power Range 300 mW to 150 W 50 W to 1000 W 100 W to 5000 W Noise Equivalent Power (mW) 1 20 20 Maximum Power Density 1 (kW/cm2) 6 1 to 2.5 1 to 2.5 Maximum Energy Density (mJ/cm 2) 600 Response Time (sec.) (0% to 95%) Speed-up On Speed-up Off Detector Coating UV UV Broadband Detector Element Thermopile Detector Diameter (mm) 50 100 100 Calibration Uncertainty (%) (k=2) ±2 ±3 ±5 Power Linearity (%) ±1 Spectral Compensation Accuracy (%) ±1.5 Calibration Wavelength (nm) 524 1070 1070 Cooling Method Water Cable Type USB and RS Cable Length (m) 2.5 (USB)/0.3 (RS) Part Number USB RS-232 1305568 1214871 1235755 1 The damage resistance of the coating is dependent upon the beam size and profile, the average power level, and the water flow rate. Contact Coherent or you local representative for details related to your application. 2 Software, water fittings and post stand included.