West, Suite 206 Everett, WA 98204 http://www.vpt-inc.com Sales Information: Phone: (425) 353-3010 Fax: (425) 353-4030 E-mail: vptsales@vpt-inc.com HIGH RELIABILITY VME POWER SUPPLY
DESCRIPTION
The VPTVME series of isolated VME power supplies is an effective COTS solution for many demanding high reliability applications. A wide input voltage range accommodates nominal 28V inputs including avionics, mobile, ground systems, and other applications. High efficiency, low input and output ripple, fixed operating frequency, and built-in EMI compliance simplify system design. Incorporating VPT’s proven design and rugged packaging heritage ensures long term reliability. The VPTVME series is intended for harsh environments including severe vibration, shock and temperature cycling. Testing is to MIL-STD-810, and MIL-STD-883 as detailed. This assembly is designed and manufactured in the USA in a facility certified to ISO9001, J-STD-001 and IPC-A-610. This product may incorporate one or more of the following U.S. patents: 5,784,266 5,790,389 5,963,438 5,999,433 6,005,780 6,084,792 6,118,673
FEATURES
- Single Slot 6U VME Form Factor
- IEEE Std 1101.2-1992 compatible
- Conduction Cooled
- 28VDC Input per MIL-STD-704
- MIL-STD-1275 Compatibility Available
- Up to 500 Watts Maximum Output Power
- Up to 5 Individual Outputs
- Input Under Voltage Lockout
- Over Voltage Protection
- Over Current Protection
- Short Circuit Protection
- Over Temperature Protection
- Fixed Frequency
- Remote Sensing
- Fast Startup time with Soft Start
- Isolated Magnetic Feedback
- Meets MIL-STD-461D/E/F Conducted Emissions Requirements
- Rugged Metal Enclosure
- Wide Temperature Range, -55°C to 85°C
- Custom Configurations are Available Figure 1 – VPTVME-28 Power Supply (Not To Scale)
SPECIFICATIONS (TCASE = -55°C to +85°C, VIN = +28V ± 5%, Full Load, Unless Otherwise Specified) ABSOLUTE MAXIMUM RATINGS Input Voltage (Continuous) 40 V DC Operating Temperature -55°C to +85°C Input Voltage (Transient, 1 second) 50 Vo lts Storage Temperature -55°C to +125°C Output Power 500 Watts Weight (Maximum) 1250 Grams Power Dissipation (Full Load, TCASE = +85°C) 89 Watts Parameter Conditions Min Typ Max Units Continuous 18 28 40 V INPUT Voltage Transient, 1 sec - - 50 V UVLO Turn On 17 - 17.8 V UVLO Turn Off 16 - 17 V POWER 0 500 W EFFICIENCY 85 - % Turn On Delay V IN = 0V to 28V - - 100 mSec Over Temperature Shutdown Rail Temperature - 95 - °C Over Temperature Shutdown Hysteresis Rail Temperature - 10 - °C ISOLATION 500 V DC 100 - - M Ω OUTPUT: +5V TCASE = 25°C 4.925 5.00 5.075 V OUTPUT Voltage T CASE = -55°C to 85°C 4.875 5.00 5.125 V Power 0 - 200 W Current 0 - 40 A Ripple Voltage Full Load, 20Hz to 10MHz - - 50 mV p-p Line Regulation V IN = 18V to 40V - - 20 mV Load Regulation No Load to Full Load - - 50 mV Load Step Output Transient - - ±300 mV pk Load Step Recovery
3 Half Load to Full Load
- - 300 μSec OUTPUT: +3.3V TCASE = 25°C 3.25 3.3 3.35 V OUTPUT Voltage T CASE = -55°C to 85°C 3.217 3.30 3.383 V Power 0 - 132 W Current 0 - 40 A Ripple Voltage Full Load, 20Hz to 10MHz - - 50 mV p-p Line Regulation V IN = 18V to 40V - - 20 mV Load Regulation No Load to Full Load - - 50 mV Load Step Output Transient - - ±300 mV pk Load Step Recovery Half Load to Full Load - - 300 μSec Notes: 1. MIL-STD-704A and MIL-STD-1275 input ranges available. Contact VPT. 2. Verified by qualification testing. 3. Time for output voltage to settle within 1% of its nominal value.
SPECIFICATIONS (TCASE = -55°C to +85 °C, VIN = +28V ± 5%, Full Load, Unless Otherwise Specified) ABSOLUTE MAXIMUM RATINGS Input Voltage (Continuous) 40 V DC Operating Temperature -55°C to +85°C Input Voltage (Transient, 1 second) 50 Vo lts Storage Temperature -55°C to +125°C Output Power 500 Watts Weight (Maximum) 1250 Grams Power Dissipation (Full Load, TCASE = +85°C) 89 Watts Parameter Conditions Min Typ Max Units OUTPUT: +12V, -12V TCASE = 25°C 11.82 12.0 12.18 V OUTPUT Voltage T CASE = -55°C to 85°C 11.70 12.0 12.30 V Power 0 - 100 W Current 0 - 8.33 A Ripple Voltage Full Load, 20Hz to 10MHz - - 100 mV p-p Line Regulation V IN = 18V to 40V - - 20 mV Load Regulation No Load to Full Load - - 100 mV Load Step Output Transient - - ±400 mV pk Load Step Recovery Half Load to Full Load - - 300 μSec OUTPUT: +5V Standby TCASE = 25°C 4.875 5.0 5.125 V OUTPUT Voltage T CASE = -55°C to 85°C 4.825 5.0 5.175 V Power 0 - 5 W Current 0 - 1 A Ripple Voltage Full Load, 20Hz to 10MHz - - 50 mV p-p Line Regulation V IN = 18V to 40V - - 20 mV Load Regulation No Load to Full Load - - 80 mV Load Step Output Transient - - ±300 mV pk Load Step Recovery Half Load to Full Load - - 500 μSec TELEMETRY: PRI INH Pin Open Circuit Voltage 2.65 2.94 3.23 V PRIMARY INHIBIT PRI INH Pin Input 0 - 1.5 V SEC INH Pin Open Circuit Voltage 2.65 2.94 3.23 V SECONDARY INHIBIT SEC INH Pin Input 0 - 1.5 V INPUT GOOD SIGNAL Low State Voltage, ISINK = 50 mA 0 - 0.6 V OUTPUT GOOD SIGNAL Low State Voltage, ISINK = 50 mA 0 - 0.6 V OVERTEMP SIGNAL Low State Voltage, ISINK = 50 mA 0 - 0.6 V Notes: 1. MIL-STD-704A and MIL-STD-1275 input ranges available. Contact VPT. 2. Verified by qualification testing. 3. Time for output voltage to settle within 1% of its nominal value.
5 V 40 A
(Optional Transient Supressor) 12 V 8.33A Isolated Forward Topology
5 V 1 A
+5V 5V RTN +3.3V 3.3V RTN +12V 12V RTN -12V +5V STBY 5V STBY RTN IN GOOD OUT GOOD OVERTEMP PRI INH Output Monitoring SEC INH
3.3 V 40 A
12 V 8.33 A Isolated Forward Topology Input Monitoring 5V SNS+ 5V SNS- 3.3V SNS+ 3.3V SNS- +12V SNS+ +12V SNS- -12V SNS+ -12V SNS- Figure 2
PRIMARY INHIBIT: The PRIMARY INHIBIT pin is used to enable / disable all outputs except for the 5V Standby output. The PRIMARY INHIBIT input is internally pulled up to 2.94V ±10% and is referenced to 28VIN RTN. If PRIMARY INHIBIT is driven high or left open, the outputs will be enabled; if pulled low, the outputs will be disabled. Cycling the PRIMARY INHIBIT pin will also clear any fault condition. SECONDARY INHIBIT: The SECONDARY INHIBIT pin is used to enable / disable all outputs except for the 5V Standby output. The SECONDARY INHIBIT input is internally pulled up to 2.94V ±10% and is referenced to 5V STBY RTN. If SECONDARY INHIBIT is driven high or left open, the outputs will be enabled; if pulled low, the outputs will be disabled. INPUT GOOD: The INPUT GOOD pin / LED indicates the condition of the input line. The INPUT GOOD pin is an open collector output and is referenced to 5V STBY RTN. Under normal operating conditions the INPUT GOOD pin is pulled low and the LED is lit green. If the input line drops below the UVLO Turn Off threshold, the INPUT GOOD pin will be open / high impedance and the LED will change to red. OUTPUT GOOD: The OUTPUT GOOD pin / LED indicates the condition of the outputs. The OUTPUT GOOD pin is an open collector output and is referenced to 5V STBY RTN. Under normal operating conditions the OUTPUT GOOD pin is pulled low and the LED is lit green. If an UVLO, Over Current, Over Voltage, or Over Temperature condition occurs or if the unit is disabled, the OUTPUT GOOD pin will be open / high impedance and the LED will change to red. The OUTPUT GOOD pin will also be open collector and the LED will be red during start-up for approximately 250ms. OVERTEMP: The OVERTEMP pin / LED indicates the unit’s mounting rail temperature. The OVERTEMP pin is open collector and is referenced to 5V STBY RTN. Under normal operating conditions the OVERTEMP pin is open / high impedance and the LED is lit green. If the unit’s temperature exceeds the over temperature threshold, all outputs except the 5V Standby will latch off, the OVERTEMP pin will be active low and the LED will change to red. The LED indication will self clear when the temperature returns to normal however the latch condition will need to be cleared by either cycling the PRIMARY INHIBIT pin or by cycling the input line below the UVLO Turn Off threshold. OVER CURRENT: Each output is protected against an over current condition. The output current is limited to approximately 125% of rated output current. A sustained over current condition will trip the over current latch, latching all outputs except the 5V Standby off. The latch condition can be cleared by either cycling the PRIMARY INHIBIT pin or by cycling the input line below the UVLO Turn Off threshold. OVER VOLTAGE: Each output is protected against an over voltage condition. The over voltage protection is activated if an output exceeds approximately 120% of its output voltage setpoint. An overvoltage condition will trip the over voltage latch, latching all outputs except the 5V Standby off. The latch condition can be cleared by either cycling the PRIMARY INHIBIT pin or by cycling the input line below the UVLO Turn Off threshold. REMOTE SENSE: The main outputs each have remote sensing capability. The remote sense pins should be connected to their respective outputs. They can be connected on the backplane to compensate for drop across the connector, or at the load. The sense lines can compensate for up to 0.5V total drop (output and return). The sense lines should be routed with their outputs to minimize noise pickup.
Figure 3 – Package Drawing (Dimensional Limits are ±0.005” Unless Otherwise Stated) Package Notes: 1. IEEE Std 1101.2-1992 compatible 2. Materials: Baseplate – aluminum , conductive conversion coating. 3. Case temperature is measured on the rail.
P1 P2 Pin No. Row A Row B Row C Row A Row B Row C
1 NC NC PRI INH SEC INH 5V STBY RTN +5V STBY
2 28VIN RTN 28VIN RTN 28VIN RTN OUT GOOD OVERTEMP IN GOOD 3 28VIN 28VIN 28VIN NC NC NC 4 28VIN RTN 28VIN RTN 28VIN RTN NC 5V SENSE - 5V SENSE + 5 28VIN 28VIN 28VIN 5V RTN 5V RTN 5V RTN 6 28VIN RTN 28VIN RTN 28VIN RTN +5V +5V +5V 7 28VIN 28VIN 28VIN 5V RTN 5V RTN 5V RTN 8 28VIN RTN 28VIN RTN 28VIN RTN +5V +5V +5V 9 28VIN 28VIN 28VIN 5V RTN 5V RTN 5V RTN 10 28VIN RTN 28VIN RTN 28VIN RTN +5V +5V +5V 11 28VIN 28VIN 28VIN 5V RTN 5V RTN 5V RTN 12 28VIN RTN 28VIN RTN 28VIN RTN +5V +5V +5V 13 28VIN 28VIN 28VIN NC NC NC 14 28VIN RTN 28VIN RTN 28VIN RTN CASE CASE CASE 15 28VIN 28VIN 28VIN CASE CASE CASE
16 NC NC NC NC NC NC
17 NC NC NC +5V +5V +5V
18 3.3V RTN 3.3V RTN 3.3V RTN 5V RTN 5V RTN 5V RTN 20 3.3V RTN 3.3V RTN 3.3V RTN 5V RTN 5V RTN 5V RTN 22 3.3V RTN 3.3V RTN 3.3V RTN 5V RTN 5V RTN 5V RTN 23 +3.3V +3.3V +3.3V NC -12V SENSE - -12V SENSE + 24 3.3V RTN 3.3V RTN 3.3V RTN 12V RTN 12V RTN 12V RTN 26 3.3V RTN 3.3V RTN 3.3V RTN 12V RTN 12V RTN 12V RTN 28 3.3V RTN 3.3V RTN 3.3V RTN 12V RTN 12V RTN 12V RTN 30 3.3V RTN 3.3V RTN 3.3V RTN 12V RTN 12V RTN 12V RTN 32 NC 3.3V SENSE - 3.3V SENSE + NC +12V SENSE - +12V SENSE +
100% ENVIRONMENTAL SCREENING Screening Condition Internal Visual IPC-A-610 Stabilization Bake MIL-STD-883, Met hod 1008, Condition A, 100°C, 24 hours Temperature Cycling MIL-STD-883, Method 1010, Condition A, -55°C to +100°C, 10 Cycles Burn-In MIL-STD-883, Method 1015, 96 hours at +85°C Final Electrical 100% at 25°C External Visual MIL-STD-883, Method 2009
ORDERING INFORMATION
CUSTOM PRODUCTS ARE AVAILABLE AND ENCOURAGED. PLEASE CONTACT VPT WITH YOUR POWER CONVERSION REQUIREMENTS TO DISCUSS IN DETAIL. Please contact your sales representative or the VPT Inc. Sales Department for more information concerning environmental screening and testing, different input voltage, output voltage, power requirement, source inspection, and/or other special requirements. CONTACT INFORMATION To request a quotation or place orders please contact your sales representative or the VPT Inc. Sales Department at: Phone: (425) 353-3010 Fax: (425) 353-4030 E-mail: vptsales@vpt-inc.com All information contained in this datasheet is believed to be accurate, however, no responsibility is assumed for possible errors or omissions. The products or specifications contained herein are subject to change without notice.