DESCRIPTION: switching power supply 1 of 2 12/10/2007 PART NUMBER: VPLN-60 Series Model VPLN-60-12 VPLN-60-15 VPLN60-20 VPLN-60-24 VPLN-60-27 VPLN-60-36 VPLN-60-48 DC output voltage 12V 15V 20V 24V 27V 36V 48V Vout tolerance 3 ±10% ±10% ±10% ±10% ±10% ±10% ±10% output rated current 5A 4A 3A 2.5A 2.3A 1.7A 1.3A output min. range 0A 0A 0A 0A 0A 0A 0A peak load 60W 60W 60W 60W 62.1W 61W 62.5W load regulation 3 ±10% ±10% ±10% ±10% ±10% ±10% ±10% efficiency 83% 84.5% 86.5% 86.5% 87% 87% 88% input voltage range 5 90~264VAC frequency range 47~63 Hz current adj. range 6 3%~-25% AC input current 0.8A/115VAC; 0.4A/230VAC inrush current 40A/230VAC leakage current 0.5mA/240VAC overload protection 95%-110% 130% (max) type: constant current limiting, recovers automatically after fault removal shortcircuit protection 4 hiccup mode, recovers automatically after fault condition is removed over voltage protection 13.8~16V 17.5~21V 22.8~25V 28~32V 31~35V 41~46V 54~60V type: shut down o/p voltage, recovers automatically after temperature goes down over temp. protection 95°C ±10°C (TSW1) detect on heatsink of power transistor type: shutdown o/p voltage, recovers automatically after fault removal temperature coefficient ±0.03% / °C (0~50°C) set up, rise, hold up time 1500ms, 100ms / 230VAC, 300ms, 100ms / 115VAC at full load vibration 10~500Hz, 2G 10min./1 cycle (1 hour each axes) withstand voltage I/P-O/P: 4.25KVAC, isolation resistance I/P-O/P, 500VDC / 100M Ohms min. working temp., humidity -30°C~+50°C (refer to output derating curve), 20%-90% RH storage temp., humidity -40°C~+80°C, 10-95% RH MTBF 497.8Khrs/min at full load 25°C MIL-HDBK-217F safety standards UL1310 Class 2,CAN/CSA C22.2 NO. 223-M91(except for 48V), EN61347-1, EN61347-2-13, IP64 Approved EMC standards CISPR11 (EN55011), CISPR22 (EN55022) class B, EN61000-3-2,3, EN61000-4,2,3,4,5,6,8,11, ENV50204, EN55024, EN61547 (light industrial level, criteria A) Notes: 1. all parameters NOT specifically mentioned are measured at 230Vac input, rated load, 25°C ambient 2. ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1 μF & 47 μF capacitor 3. tolerance includes set up tolerance, line regulation, load regulation 4. please refer to OLP characteristics. 5. derating may be needed under low input voltage. Please check the derating curve for more details 6. output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through t he SVR2 on the PCB

features

  • universal AC input / full range
  • fully isolated plastic case with IP64 level
  • built-in constant current limiting circuit with adjustable OCP level
  • protections: short circuit/over load/over voltage/over temperature
  • built-in active PFC function
  • IP64 design for indoor or outdoor installations
  • UL1310, Class 2 power unit
  • 100% full load burn-in test
  • cooling by free air convection
  • suitable for LED lighting and moving sign applications
  • high realibility
  • 2 year warranty

DESCRIPTION: switching power supply 2 of 2 12/10/2007 PART NUMBER: VPLN-60 Series Ta: 25°C AMBIENT TEMPERATURE ) LOAD (%) - 3 0 - 2 5 - 5 0 1 53 04 05 06 0 100 INPUT VOLTAGE(V) 60Hz 90 100 125 135 145 155 165 175 180 200 230 264 100 LOAD (%) (HORIZONTAL) FG (Green/Yellow) 300

300 DC OUT

6.26 6.26 181 18AW G 2C 21.25 61.5 21.25 +V(Red) -V(Black) 2-R2.5 18AW G 3C AC/L(Brown) AC/N(Blue) Output Derating Static Characteristics Dimensions (mm) Block Diagram fosc: 90 KHz (115 V ac)

120 KHz (230 V ac)

PWM & FFC CIRCUITO.L.P. EMI FILTER RECTIFIERS POWER SWITCH- FILTER RECTIFIERS +V -VI/P FG ING CONTROL O.V.P. O.C.P.