features
- power factor correction
- power good signal
- short circuit protection
- over load, volt age, temperature protection
- approved to UL/cUL, TUV , CE with CB scheme
- N+1 p arallel redundancy
- extended temperature range: -40 ~ +75°C available MODEL preset max. output 4 output 1, 2, 3 volt age power / current (A) ripple & noise 5, 6 (V) (V) with force air convection regulation 5 (Vp-p) VPF-S200-03RI 3 - 4 V 3.3 V 30 A 22 A ±1% ±1% VPF-S200-05RI 5 - 6 V 5 V 200W 22 A ±1% ±1% VPF-S200-12RI 12 - 18 V 12 V 200W 150W ±1% ±1% VPF-S200-24RI 24 - 30 V 24V 200W 150W ±1% ±1% VPF-S200-36RI 32 - 46 V 36 V 200W 150W ±1% ±1% VPF-S200-48RI 48 - 56 V 48 V 200W 150W ±1% ±1% notes: 1. customer must specify output volt age on PO 2. output is fully isolated 3. output volt age is measured at output power connector 4. maximum 200 W with 18. cfm forced ventilation 5. 1% minimum load is required to maint ain the ripple and regulation 6. ripple and noise are measured from 10 KHz to 20 MHz at output terminals with a 0.1 µF ceramic cap acitor and a 22 µF cap acitor in p arallel. DESCRIPTION: switching power supplyPART NUMBER: VPF-S200-XXRI series
DESCRIPTION: switching power supply PART NUMBER: VPF-S200-XXRI series 2 of 5 11/19/2007 INPUT parameter conditions/description min nom max unit s input frequency 47 63 Hz input volt age 90~132 / 180~264 auto-select able 90 264 VAC input current AC input of 1 15 V AC 5 A AC input of 230 V AC 2.5 A inrush current peak measured at 1 15 V AC at full load, cold st art 35 A peak measured at 230 V ACat full load, cold st art 70 A power factor active power factor correction meet s EN61000-3-2 class A (tot al output power not to exceed 200 W) OUTPUT parameter conditions/description min nom max unit s transient response output volt age returns to within 1% in less than 2.5ms for a 50% load change. peak transient does not exceed 5%. overshoot turn-on and turn-of f overshoot will not exceed 5% over nominal volt age efficiency measured at 230 V and full load:
3.3 V model 70 %
5 V model 75 %
12 V model 80 %
all other models 83 % start up time at 120 V ac, full load 1 S hold up time at 120 V ac, full load 20 mS adjust ability output use adjust able - 5 +5 % LED display when green (LED1) is on, power supply is operating normally power good designated as PG on the CN1. this signal goes high 100-500 mS af ter the output reaches regulation. low at least 1 mS before loss of regulation. PROTECTION CIRCUITS parameter conditions/description input fuse one T5A / 250V fuse inserted in primary overload current limiting st arts at 110~135% of the rated output current in foldback mode and recovers automatically output over-voltage output is protected against overvolt age. Unit shut s down and latches when volt age at output terminals exceeds 130%. ac input needs to be reset to rest art the power supply . short circuit trip without damage and auto-recovery . over temp. Power supply shuts down when temperature is in excess of 85 ºC. auto recovery.
DESCRIPTION: switching power supply PART NUMBER: VPF-S200-XXRI series 3 of 5 11/19/2007 GENERAL & SAFETY parameter conditions/description min nom max unit s operating temp. derates linearly from 100% load at 50°C to 0 40 °C 50% load at 70°C optional operating derates linearly from 100% load at 50°C to -40 75 °C temp. 37.5% load at 75°C storage temp. -20 85 ºC optional storage temp. -40 85 ºC operating humid. non-condensing 5% 90% RH storage humid. non-condensing 5% 95% RH operating altitude 3,000 m 10,000 ft storage altitude 9,000 m 30,000 ft EMI conducted emissions comply with FCC p art 15, CISPR 22 class B safety approved to UL 1950(E222889), CSA C22.2 No. 60950-1-03, TUV EN60950-1, CE Mark (L VD), EN61000-3-2, & IEC61000-4 series regulations, CB leakage current at 240 V ac 1.5 mA vibration acceleration ±7.35 M/(SxS), on X, Y, and Z axis 5 50 Hz isolation volt age applied for 3 seconds. (HI-POT) primary to secondary: 3000 VAC primary to transformer core: 1500 VAC primary to earth ground: 1500 VAC grounding test allowable resist ance measured when 25 A current is 0.1 Ω applied from the ground pin of the three pronged plug to the farthest earthed connection point. RoHS yes warranty standard warranty length 2 years MTBF according to MIL-HDBK-217 at 30°C 100,000 hours burn-in full load, at 45 ±5°C, 230 V ac 1 hours cooling built-in dc fan speed control Note : Customer must specify extended temperature on PO. MECHANICAL parameter conditions/description min nom max unit s weight 600 g mountin screws one set of 8 threaded mounting holes available on the enclosure A:M4, maximum insertion depth of 0.2 inches. MATING CONNECT ORS parameter conditions/description AC input(option 1) Molex Part No. 26-48-1201 or similar (5 pin). Suggested mating plug: Molex Part No. 09-91-0500 or equivalent (5 pin, 3 used) AC input(option 2) Terminal block Part No. FTB-702-3P (3 pin, M3 Screw) 7.62mm sp acing Suggested mating connector: Molex 19198-0016 or similar Note : Input connector must be specified on PO.
DESCRIPTION: switching power supply PART NUMBER: VPF-S200-XXRI series 4 of 5 11/19/2007 OUTPUT CONNECT OR - (CN2) parameter conditions/description min nom max unit s output (option 1) Molex Part No. 09-91-1200 or similar . (12 pin) Output pin assignment, VO+ (Pins 1-6), VO- (Pins 7-12) Suggested mating connector: Molex 12 pin (p art No. 09-91-1200) output (option 2) Howder Terminal block Part No. HD-301-4P (4 pin, M3.5 Screw) 1 1mm sp acing Output pin assignment, VO+ (Pins 1-2), VO- (Pins 3-4) Suggested mating connector: Molex 19198-0045 or similar . Note : Output connector must be specified on PO. LOGIC CONNECT OR - (CN3) parameter conditions/description min nom max unit s Logic JS B6B-XH-A Suggested mating connector: JS-2001-06 or equivalent , Cont act: SXH-002T -P0.6. Pin Assignment s: 1. F AN+ 2. F AN- 3. R TN 4. PG 5. REMO 6. R TN
DESCRIPTION: switching power supply PART NUMBER: VPF-S200-XXRI series 5 of 5 11/19/2007 OUTLINE DRAWING VO- VO+ VO- VO+ IN PUT OU TPUT