V78W-500 CUI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

cui.com date 04/21/2015 page 1 of 5 SERIES: V78W-500 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR MODEL input voltage output voltage output current output power ripple and noise1 efficiency level2 range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) V7803W-500 9 ~ 72 3.3 10 500 1.65 60 82 V7805W-500 9 ~ 72 5 10 500 2.5 60 87 V7806W-500 9 ~ 72 6.5 10 500 3.25 60 91 V7809W-500 14 ~ 72 9 10 500 4.5 60 92 V7812W-500 17 ~ 72 12 10 500 6 60 93 V7815W-500 20 ~ 72 15 10 500 7.5 60 94 V7824W-5003 36 ~ 72 24 6 300 7.2 60 95 Notes: 1. 20MHz bandwidth, from 10% to 100% load 2. Measured at Vin min and 100% load 3. V7824W-500 output current is 300 mA (max) date 04/21/2015 page 1 of 5

FEATURES

  • up to 500 mA current output
  • extremly high efficiency up to 95%
  • no heatsink required
  • pin comparable to LM78 linear regulators
  • available in straight and right angle SIP packages
  • up to 8:1 ultra wide input
  • low ripple and noise
  • short circuit protections
  • wide temperature (-40°C ~ 85°C) RoHS PART NUMBER KEY V78 XX W - XXX X Output VoltageBase Number Output Current blank = standard R = Right Angle For more information, please visit the product page.

cui.com date 04/21/2015 │ page 2 of 5CUI Inc │ SERIES: V78W-500 │ DESCRIPTION: DC-DC CONVERTER INPUT parameter conditions/description min typ max units operating input voltage 3, 5, 6.5 V models

9 V model

12 V model

15 V model

24 V model

parameter conditions/description min typ max units line regulation measured from low line to high line ±0.4 ±1.0 % load regulation measured from 10% to full load ±0.3 ±0.6 % voltage accuracy at 100% load ±2 ±3 % switching frequency 100% load 120 800 kHz temperature coefficient -40°C ~ +85°C ambient ±0.015 %/°C quiescent current Vin = nominal, min. load 1 5 mA tendencies load at 10% to 100% load 1.0 ±100 1.5 mV ms max capacitance load 100 µF PROTECTIONS parameter conditions/description min typ max units short circuit protection continuous, automatic recovery short circuit input power Vin = nominal 0.72 1.2 W thermal shutdown 160 °C current limit Vin = nominal 700 1200 mA SAFETY AND COMPLIANCE parameter conditions/description min typ max units thermal resistance 60 °C/W EMI/EMC EN55022, class B (refer to page 4), IEC/EN 61000-4-2 level 4 RoHS compliant yes MTBF 25°C (MIL-HDBK-217K) 71°C (MIL-HDBK-217K) 3,500,000 1,500,000 hours hours ENVIRONMENTAL parameter conditions/description min typ max units case operating temperature 65 100 °C operating temperature power derating above 71°C -40 85 °C storage temperature -55 125 °C storage humidity non-condensing 95 % For more information, please visit the product page.

cui.com date 04/21/2015 │ page 3 of 5CUI Inc │ SERIES: V78W-500 │ DESCRIPTION: DC-DC CONVERTER 2.15 0.085 2.15 0.085 5.08 0.200 5.08 0.200 2 0.0200.50 0.55 0.022 9.00 0.354 9.00 0.354 4.10 0.161 213 11.50 0.453 0.020 17.50 0.689 0.50 4.10 0.161 11.50 0.453 1.50 0.059 17.50 0.689 0.50 0.020 MECHANICAL DRAWING MECHANICAL parameter conditions/description min typ max units case material Plastic (UL94-V0) weight 4 g Units: mm [in] All pins on a 2.54mm pitch pin tolerance: ±0.10mm[±0.004in] general tolerance: ±0.25mm[±0.010in] general tolerance (right angle): ±0.50mm[±0.020in] V78W-500 V78W-500R RECOMMENDED FOOTPRINT 1.10 0.043 (3 PLCS)5.08 0.200 2.15 0.085 2.54 0.100 2.54 0.100 1.10 0.043 (3 PLCS) 1.35 0.053 5.08 0.200 2.54 0.100 2.54 0.100 213 PIN CONNECTIONS 1 +Vin

2 GND

For more information, please visit the product page.

cui.com date 04/21/2015 │ page 4 of 5CUI Inc │ SERIES: V78W-500 │ DESCRIPTION: DC-DC CONVERTER TYPICAL APPLICATION CIRCUIT MODULES PROTECT RECOMMENDED CIRCUIT APPLICATION EXAMPLE DERATING CURVE Operating Temp.( )C TemperatureD erating Graph 3+Vin GND +Vout GND V78W-500(R) 3+Vin GND GND F +5V/850mAC1 +12V/100mA Reversep rotection V7812W-500(R) V7805W-500(R) +Vin +Vout GND GND 1 3 +Vin +Vout- GND GND 1 3 Scho ttky Diode Vout= 0.3V V78W-500(R) V78W-500(R) EMC RECOMMENDED CIRCUIT +Vin ND 1.0FF-3.3 0.5mH-2m H 0.68 F-2.2F Vin +Vou t GN D 27 0F -470 F RL 0.5mH-2m H 1. The regulator proposed to establish the input voltage by soft-start, no plug and play, if the input voltage changes from low voltage to high voltage abruptly, the regulator might be damaged. 2. If the applications is high-voltage input, the regulator must add an external capacitor C1(≤47μF/100V) to prevent voltage spikes caused by damage to the module. 3. No parallel connection. 1. The input current amount of the back-grade regulator and the pre-class load should be less than or equal the max load current of the pre-class regulator. 2. If further filtering is required, please add components as per the above circuit (We recommend not to add components), if request, please make sure the capacitors C1 ≤47μF, C2≤10μF more close to the back-grade regulator. High voltage input, multiple outputs, with greater load For more information, please visit the product page.

date 04/21/2015 │ page 5 of 5CUI Inc │ SERIES: V78W-500 │ DESCRIPTION: DC-DC CONVERTER CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 09/28/2011

1.01 V-Infinity branding removed 09/06/2012

1.02 updated datasheet 04/21/2015 The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY

For more information, please visit the product page.