cui.com date 03/21/2014 page 1 of 6 SERIES: V78-2000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 03/21/2014 page 1 of 6

FEATURES

  • 2 A current output
  • extremely high efficiency up to 92%
  • no heat sink required
  • pin compatible to LM78XX linear regulators
  • available in straight and right angle SIP packages
  • low ripple and noise
  • short circuit protection, thermal shutdown
  • wide temperature (-40~85°C) PART NUMBER KEY MODEL input voltage output voltage output current output power ripple and noise1 effi ciency typ (Vdc) range (Vdc) (Vdc) max (mA) max (W) max (mVp-p) Vin min (%) Vin max (%) V7802-2000* 12 4.75~18 2.5 2,000 5 45 85 83 V7803-2000 12 4.75~18 3.3 2,000 6.6 45 87 86 V7805-2000 12 6.5~18 5 2,000 10 45 91 88 V7806-2000 12 8~18 6.5 2,000 13 45 92 91 Notes: 1. ripple and noise are measured at 20 MHz BW *. Discontinued V78 XX - 2000 X Output Voltage Output CurrentBase Number "blank" = straight pins R = 90° pins For more information, please visit the product page.

cui.com CUI Inc │ SERIES: V78-2000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 03/21/2014 │ page 2 of 6 INPUT parameter conditions/description min typ max units operating input voltage 2.5 and 3.3 V outputs

5 V output

6.5 V output

4.75 8.5 Vdc Vdc Vdc OUTPUT parameter conditions/description min typ max units line regulation Vin = min ~ max, at full load ±0.5 ±0.75 % load regulation measured from 10% load to full load ±0.5 ±1.0 % voltage accuracy 100% load ±2 ±3 % switching frequency 100% load, input voltage range 300 340 380 kHz temperature coeffi cient ±0.03 %/°C PROTECTIONS parameter conditions/description min typ max units short circuit protection continuous, automatic recovery thermal shutdown internal IC junction 150 °C SAFETY AND COMPLIANCE parameter conditions/description min typ max units EMI/EMC EN 55022 class B, EN 61000-4-2 level 3 6kV / 8kV perf. criteria B MTBF 2,000,000 hours RoHS 2011/65/EU ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -40 85 °C storage temperature -55 125 °C case temperature 100 °C storage humidity non-condensing 95 % temperature rise at full load 25 °C lead temperature 1.5 mm from case for 10 seconds 300 °C For more information, please visit the product page.

cui.com CUI Inc │ SERIES: V78-2000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 03/21/2014 │ page 3 of 6 MECHANICAL parameter conditions/description min typ max units case material plastic (UL94-V0) weight 4.0 g (Bottom View) 0.30 [0.012] 0.50 [0.020] 4.10 [0.161] 17.50 [0.689] 0.50 [0.020] 2.15 [0.085] 5.08 [0.200] 12 3 9.00 [0.354] 2.15 [0.085] 4.10[0.161] 9.00 [0.354] V78XX-2000R 11.50[0.453] 17.50 [0.689] 0.50 [0.020] 5.08 [0.200] 11.50[0.453] 1.50 [0.059] 123 V78XX-2000 (Bottom View) 2.54 [0.100] 1.00 [0.039] 12 3 2.54 [0.100] 2.15 [0.085] 5.08 [0.200] 1.00 [0.039] 5.08[ 0.200] 1.35 [0.053] MECHANICAL DRAWING PIN CONNECTIONS PIN FUNCTION 1 +Vin

2 GND

units: mm [inches] tolerance: ±0.25 [±0.010] pin section tolerance: ±0.10 mm [±0.004] 100 Ambient Temperature (°C) Load (%) -40 -20 0 20 40 60 71 85 100 120 DERATING CURVES 1. output power vs. ambient temperature For more information, please visit the product page.

cui.com CUI Inc │ SERIES: V78-2000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 03/21/2014 │ page 4 of 6 EXTERNAL CAPACITOR TABLE Part Number C1 (Ceramic capacitor) C2 (Ceramic capacitor) V7802-2000 10 μF/25V 22 μF/6.3V V7803-2000 10 μF/25V 22 μF/6.3V V7805-2000 10 μF/25V 22 μF/16V V7806-2000 10 μF/25V 22 μF/16V V78XX-20001 3Vin GND +Vout C2C1 Positive Output V78XX-2000 Negative Output 3+Vin GND -Vout GND GND INPUT FILTER CIRCUIT OUTPUT FILTER CIRCUIT Vin GND 10uF 10uH-47u H 10uF Vin Vo GND Vout GND Vin GND 10uF 10uH-47uH 22uF Vin Vo GND 10uF RL V78XX-20001 +Vin GND -Vou t GND V78XX-20001 3 +Vout C3 C4 Note: 1. C1 and C2 are required and should be fitted close to the converter pins. 2. The capacitance of C1and C2 sees external capacitor table, it can be increased properly if required, and tantalum or low ESR electrolytic capacitors may also suffice. 3. No parallel connection or plug and play. TYPICAL APPLICATION CIRCUIT APPLICATION EXAMPLE For more information, please visit the product page.

cui.com CUI Inc │ SERIES: V78-2000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 03/21/2014 │ page 5 of 6 EMC RECOMMENDED CIRCUIT TEST CONFIGURATION Vin GND 2.2uF 1mH 1uF Vin Vo GND 1mH 330uF Vout GND Efficiency and Output Voltage Ripple Test ScopeCeramic Vin GND +Vout C2C1 25.4m m 2.54 mm DC/DC Converter 25.4mm 12.7mm 1F 10 F Tantalum Copper strip Copper strip Load Start-up and Load Transient Response Test Vin GND +Vout C2C1 50.8 mm 2.54m m DC/DC Converter

2 Scope

EFFICIENCY AND RIPPLE CURVES Efficiency Ripple Efficiency VS. Input voltage (full load) 100 4.75 5 6 6.5 7.2 8 9 10 12 15 18 20 Input voltage(V) Effici en cy (% ) V7802-2000 V7803-2000 V7805-2000 V7806-2000 Ripple VS. Load(Vin=nominal) 200 400 600 800 1000 1200 1400 1600 1800 2000 Load(mA) Ri pple(mV) V7802-2000 V7803-2000 V7805-2000 V7806-2000 Ripple VS. Input voltage(full load) 4.75 5 6 6.5 7.2 8 9 10 12 15 18 20 Input Voltage(V) Ri pple( m V) V7802-2000 V7803-2000 V7805-2000 V7806-2000 Efficiency VS. Load(Vin=nominal) 100 200 400 600 800 1000 1200 1400 1600 1800 2000 Load(mA) Eff ic ienc y(% ) V7802-2000 V7803-2000 V7805-2000 V7806-2000 For more information, please visit the product page.

CUI Inc │ SERIES: V78-2000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 03/21/2014 │ page 6 of 6 CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 06/17/2010

1.01 V-In fi nity branding removed 09/06/2012

1.02 updated typical application circuits 09/25/2012 1.03 discontinued model V7802-2000 03/21/2014 The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY