V4KU-01JS-001 OMRON | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 12

Technical content

MTA-B-03023 A (1/12) ADVANCED MODULES BUSINESS COMPANY © OMRON Corporation 2003 All Rights Reserved Hardware Specifications of V4KU-*** Series Hybrid Manual Insertion Card Reader Rev. A Oct 16. 2003

MTA-B-03023 A (2/12) Table of Contents 1. Abstract 4 2. Reference Standards 4 3. Definition of Terminology 5 4. Applicable Module Name 6 5. Specifications 6

5.1 Mechanical Specification 6

5.2 Magnetic card function 6

5.3 ICC function 7

5.4 SAM 7

5.5 Shutter function 7

5.6 Lock function 7

5.7 Power Requirement 8

5.8 Electrical interface 8

5.9 Software Interface 8

5.10 LED Indicator 8

5.11 Diagnostics function 9

  1. Environmental Condition 9 7. General performance 9 8. Life 9 9. Outline drawing 10 10. Appendix A 12

MTA-B-03023 A (3/12) [Specification History of Modification] Rev Date Page Content A Oct 8, 2003 The first edition is created.

MTA-B-03023 A (4/12) 1. Abstract This document provides the hardware specificati ons of Hybrid Manual Insertion Card Reader of V4KU-*** Series with USB interface. This equipment can read the dat a of Magnetic Card, and read/write the data of IC card. 2. Reference Standards [1] ISO/IEC 7810: 1995-08-15 Identification cards - Physical characteristics Identification cards -- Recording technique [3] ISO 7816-1:1998 Identification cards -- Integrated circuit(s) cards with contacts Part 1: Physical characteristics [4] ISO 7816-2:1999 Identification cards -- Integrated circuit(s) cards with contacts Part 2: Dimensions and location of contacts [5] ISO/IEC 7816-3:1997 Identification cards -- Integrated circuit(s) cards with contacts Part 3: Electronic signals and transmission protocols [6] ISO/IEC 7816-4: 1995 Identification cards -- Integrated circuit(s) cards with contacts Part 4: Inter-industry commands for interchange [7] ISO/IEC 7816-4: 1995/Amd 1:1997 Secure messaging on the structures of APDU messages [8] EMV2000 Integrated Circuit Card Specification for Payment Systems Book 1 Application Independent ICC to Terminal Interface Requirements Version 4.0 December, 2000 [9] ENV1375-1: 1994 Interjectors integrated circuit(s) cards additional formats Part 1. ID-000 000 card size and physical characteristics [10] USB 2.0 Universal Serial Bus Specification, Compaq/Hewlett-Packard/Intel/Microsoft/NEC/Philips, Revision 2.0 April 27, 2000

MTA-B-03023 A (5/12) 3. Definition of Terminology LED Light-Emitting Diode PCB Printed-Circuit Board S1 Positioning Sensor of Insertion slot S2 Positioning Sensor of Rear End S3 Sensor to detect the lock/release of Lock blade ICC Integrated Circuit Card SAM Secure Application Module C/R Card Reader ATR Answer to Reset Etu Elementary Time Unit Vpp Voltage at VPP Vcc Voltage at VCC Host HOST Terminal FW Firmware LED PCB ICC contact Insert S3 S1 S2 LOCK Mag. Head

MTA-B-03023 A (6/12) 4. Applicable Module Name Magnetic card read No Module Name Track 1 Track 2 Track 3 ICC controller SAM Bezel

1 V4KU-01JS-001 R*1 R R Y*2 Y*3 Round Type

2 V4KU-01JF-001 R R R Y Y Flat Type

*1 R : Magnetic reading function *2 Y : 8 contacts for C1 to C8 are provided. *3 Y : 1 SAM Provided 5. Specifications

5.1 Mechanical Specification

[1] External dimensions (See Outline Drawing) Width Height Length V4KU-01JS-001 80.0mm 50.0mm 133.0mm V4KU-01JF-001 101.6mm 76.2mm 133.0mm [2] Weight Less than 250g [3] Mounting (See Mounting Drawing) (1) In case of using the Mounting Hole (V4KU-01JS-001, V4KU-01JF-001) 1) Screw M3 2) Quantity 4 pieces 3) Torque Less than 0.79N¥m <Notice> Design the mounting bases to keep the difference within +/ -0.2mm in height among four mounting holes (refer to Outline drawing about location of these holes) (2) In case of using the Screw Hole of Bezel (V4KU-01JF-001) 1) Screw M4 2) Quantity 4 pieces 3) Torque Less than 1.30N¥m <Notice> Select the screw in order to keep the meshing length 4.0mm or less. [4] Card position detection Two photo sensors (S1, S2) are provided in order to detect the card. The state of these sensors can be retrieved by the command and response.

5.2 Magnetic card function

[1] Magnetic card type In conformity to ISO/IEC 7810, ISO/IEC 7811-1/2/3/6 [2] Reading function Read specified tracks simultaneously. [3] Reading direction Bi-directional capability (insert/pull out) [4] Card speed 100-1000 mm/s capability (at flat card)

MTA-B-03023 A (7/12)

5.3 ICC function

[1] Number and location of contacts on ICC Number and location of contacts on ICC are specified in ISO 7816-2 figure 2. [2] Applicable ICC (1) Asynchronous card 1) Support ICC In conformity to ISO/IEC 7816-1/2/3, EMV4.0 Level1 2) Protocol T=0 and T=1 3) Data byte reading/writing Inverse conv ention (MSB first, negative logic) and direct convention (LSB first, positive logic) 4) Clock during/after ATR 3.5712 MHz(Conform to ISO / IEC 7816-3) 5) Communication speed T=0: 1etu = 372/ (3.5712 x 10 6) sec (Constant Value) T=1: 1etu = (372/D) x 1/(3.5712 x 106) sec D=1(Default), 2, 4 6) Vpp Not connected 7) Vcc 5V / 3V (Type A and Type B) (2) Synchronous card 1) Support ICC In conformity to ISO/IEC 7816-1/2/10, SLE4442/4428/4432 2) Vcc 5V 3) Vpp Not connected <Notice> OMRON asks customers to check the performance of ICC with OMRON standard ICC controller and FW in advance, if ICC is special card. Because ISO standard and ICC(s) are subject to frequent modification. OMRON supports you for capability of performing customer’s ICC, provided with ICC and its specification.

5.4 SAM

[1] 1 SAM controller is equipped with shipment. 1 SAM socket is mounted on the PCB. [2] SAM specification 1) Support SAM chip In conformity to ENV1375-1(ID000) 2) Vpp Not connected 3) Vcc 5V/3V

5.5 Shutter function

[1] This shutter is equipped on the insertion slot of the C/R. It opens automatically by inserting the card. It prevents foreign objects like dusts and coins from intruding to inside. [2] This shutter should open by inserting the card that is more than 53.92mm in width.

5.6 Lock function

[1] Pin type lock mechanism is equipped to hold the card during operation of ICC in response to command from host. [2] This lock mechanism can be controlled by the command from the host. [3] The condition of this lock mechanism can be checked by the command and response. [4] This lock mechanism is released automatically at the power failure. [5] This Lock mechanism works under the below conditions (1) The card is inserted completely. (2) The card does not exist inside of C/R.

MTA-B-03023 A (8/12)

5.7 Pow er Requirement

[1] Power supply voltage 21.6 - 26.4V DC (including ripple) [2] Ripple of power supply 100mV (p-p) or less [3] Power consumption (Input voltage: 24V DC) In operation magnetic card 500mA or less IC card 1.0A or less In Standby 100mA or less [4] Power supply connector 4 nodes, 2.54mm pitch in serial 5046-04A(Molex Japan) is used in PCB 4 NC 3 NC

2 GND

(connector on the side of cable) Pin assignment of C/R Pin No. Assigned power rails 1 +24V: Power supply

2 GND: Power ground

(Cable with connector for Power supply is not included) [5] Power failure 1) Detection Voltage Less than 21.6V DC 2) Power failure process In case of power failure, C/R deactivates the ICC and releases the Lock.

5.8 Electrical interface

[1] Interface specification (1) Protocol Version Compliance with USB Version 2.0 certified logo program (2) Power supply Self-powered (3) Device Class Human Interface Devices (HID) class (4) Transmission Speed Full Speed (12Mbps) (5) Transmission Type Interrupt Out for command Interrupt In for response [2] USB interface connector Type B Connector (USB interface Cable between Host and C/R is not attached. You should use the cable meet the Universal Serial Bus Specification)

5.9 Softw are Interface

[1] Transmission protocols V4KU Series Card Reader Data Transmission Specification (Document No. MTA-H-03022). [2] Port to host Handling with a magnetic card and an IC card via single port [3] Format A common APDU format is used for handling various ICC [4] Downloadable All software are supported to be downloaded. [5] Module Firmware is independently divided into every functional module (e.g. ICC handling module, SAM handling module, etc) and every module can be independently downloaded (regardless of order of download) respectively.

5.10 LED Indicator

[1] One LED is equipped to inform the state of C/R and the reading result of the magnetic data. [2] This LED can be indicated the three colors (green, red and orange). [3] The specification of LED indicator can be controlled by the command from the host. In detail, refer to V4KU Series Card Reader Data Transmission Specification (Document No. MTA-H-03022).

MTA-B-03023 A (9/12)

5.11 Diagnostics function

[1] C/R provides the following functions as diagnostics of each module in the C/R. This function is performed by pressing the white button located on the top of C/R just near SAM socket. The test card is required to perform diagnostics. This function reports the following. *1 (1) OK/NG for Sensor Level (2) OK/NG for Magnetic card reading (3) OK/NG for LOCK mechanism (4) OK/NG for ICC function [2] C/R indicates the result of the diagnostics by using LED indicator. *1 *1 In detail, V4KU Series Card Reader Data Transmission Specification (Document No.MTA-H-03022). <Notice> Make sure not to press this button, when the system is in operation. 6. Environmental Condition [1] Temperature (1) In operation 5 to 55 Ž (2) In storage -25 Ž for 16 hours to 70 Ž for 72 hours for non operation and transport [2] Humidity (1) In operation 5 to 85% RH, no c ondensation and absolute air humidity of 23 g/m3 or less (2) In storage 5 to 90% RH, no condens ation and absolute air humidity of 40 g/m3 or less 7. General performance [1] Insulation Resistance 20Mƒ¶or more at 100V DC (At normal temperature and humidity) [2] Dielectric Strength 500V AC for 1minute [3] Durable Vibration Frequency 10-150 Hz Single vibration width 0.10mm Acceleration 15mm/s2 Direction X,Y,Z [4] Shock Endurance Acceleration 150mm/s 2 Direction X,Y,Z 8. Life [1] Card Reader life 800,000 passes or 5 years, whichever comes earlier. [2] Magnetic head life *1 1,000,000 passes (minimum) [3] IC contact unit life *2 300,000 operations (Contact unit should be replaced every 300,000 operations.) *1 One pass denotes forward and backward movement. *2 One operation denotes the movement of fully insertion and extraction.

MTA-B-03023 A (10/12) 9. Outline drawing (1) V4KU-01JS-001 Dimensions in millimeters

MTA-B-03023 A (11/12) (2) V4KU-01JF-001 Dimensions in millimeters

  1. Number and locations of the contacts

This part of ISO 7816 defines eight contacts referred to as C1 to C8. The contacts are located as shown in figure 2. and upper edges of the front surface of the end. Figure 2. Contacts location