V185BJ1 INNOLUX | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 34
Technical content
Datasheet sections
- 1.1 OVERVIEW
- 1.2 FEATURES
- 1.3 MECHANICAL SPECIFICATIONS
- 2.1 ABSOLUTE RATINGS OF ENVIRONMENT
- 2.2 ABSOLUTE RATINGS OF ENVIRONMENT (OPEN CELL)
- 2.3 ELECTRICAL ABSOLUTE RATINGS
- 2.3.1 TFT LCD MODULE
- 3.1 TFT LCD MODULE
- 4.1 TFT LCD OPEN CELL
- 5.1 TFT LCD OPEN CELL INPUT
- 5.2 LVDS INTERFACE
- 5.3 COLOR DATA INPUT ASSIGNMENT
- 5.4 FLICKER (Vcom) ADJUSTMENT
- 6.1 INPUT SIGNAL TIMING SPECIFICATIONS
- 6.2 POWER ON/OFF SEQUENCE
- 7.1 TEST CONDITIONS
- 7.2 OPTICAL SPECIFICATIONS
- 8.1 ASSEMBLY AND HANDLING PRECAUTIONS
- 8.2 SAFETY PRECAUTIONS
- 9.1 INX MODULE LABEL
The copyright belongs to InnoLux. Any unauthorized use is prohibited Customer: APPROVED BY SIGNATURE Name / Title Note Please return 1 copy for your confirmation with your signature and comments. Tentative Specification Preliminary Specification Approval Specification MODEL NO.: V185BJ1 SUFFIX: PE1 Approved By Checked By Prepared By Chao-Chun Chung Ying-Ping Lee Kolo Huang
The copyright belongs to InnoLux. Any unauthorized use is prohibited
The copyright belongs to InnoLux. Any unauthorized use is prohibited
REVISION HISTORY
Version Date Page(New) Section Description Ver. 0.0 Nov.12, 2013 All All The Tentative Specification was first issued.
The copyright belongs to InnoLux. Any unauthorized use is prohibited 1. GENERAL DESCRIPTION
1.1 OVERVIEW
V185BJ1-PE1 is a 18.5” TFT Liquid Crystal Display product with driver ICs and 1ch-LVDS interface. This product supports 1366 x 768 HDTV format and can display 16.7M colors (8-bit). The backlight unit is not built in.
1.2 FEATURES
CHARACTERISTICS ITEMS SPECIFICATIONS Screen Diagonal [in] 18.5 Pixels [lines] 1366 x 768 Active Area [mm] 409.8 (H) x 230.4 (V) (18.5” diagonal) Sub-Pixel Pitch [mm] 0.1 (H) x 0.3 (V) Pixel Arrangement RGB Vertical Stripe Weight [g] (317g) Typ. Physical Size [mm] 422.20 (H) x 285.65 (V) x 2.85 (D) Typ. Display Mode Transmissive Mode / Normallly Black Contrast Ratio Typ.3000:1 (Typical value measure by INX’s Module) Glass thickness (Array / CF) [mm] 0.5 / 0.5 Viewing Angle (CR>20) Typ. +88/-88(H), +88/-88(V) (CR20) (Typical value measured by INX’s module) Color Chromaticity R = (0.660, 0.325) G = (0.273, 0.590) B = (0.135, 0.107) W= (0.309, 0.351) * Please refer to “color chromaticity” in 7.2 Cell Transparency [%] (4.9%) * Please refer to “Transmittance” in 7.2 Polarizer Surface Treatment Anti-Glare coating (Haze 1%) Rotation Function Unachievable Display Orientation Signal input with “INX”
The copyright belongs to InnoLux. Any unauthorized use is prohibited
1.3 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note Weight (301) (317) (333) g - I/F connector mounting position The mounting inclination of the connector makes the screen center within ± 0.5mm as the horizontal. - (2) Note (1) Please refer to the attached drawings for more information of front and back outline dimensions. Note (2) Connector mounting position. +/- 0.5mm
The copyright belongs to InnoLux. Any unauthorized use is prohibited 2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Min. Max. Unit Note Storage Temperature TST -20 +60 ºC (1) With INX Module Operating Ambient Temperature TOP 0 50 ºC (1), (2) With INX Module Note (1) Temperature and relative humidity range is shown in the figure below. (a) 90 %RH Max. (Ta 40 C). (b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC). (c) No condensation. Note (2) Thermal management should be considered in final product design to prevent the surface temperature of display area from being over 65 ºC. The range of operating temperature may degrade in case of improper thermal management in final product design.
2.2 ABSOLUTE RATINGS OF ENVIRONMENT (OPEN CELL)
Recommended Storage Condition: With shipping package. Recommended Storage temperature range: 255 Recommended Storage humidity range: 50±10%RH Recommended Shelf life: a month.
The copyright belongs to InnoLux. Any unauthorized use is prohibited
2.3 ELECTRICAL ABSOLUTE RATINGS
2.3.1 TFT LCD MODULE
Min. Max. Unit Note Power Supply Voltage VCC (-0.3) (5.5) V Logic Input Voltage VIN (-0.3) (3.6) V (1) Note (1) Permanent damage to the device may occur if maximum values are exceeded. Function operation should be restricted to the conditions described under Normal Operating Conditions.
The copyright belongs to InnoLux. Any unauthorized use is prohibited 3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE
(Ta = 25 ± 2 ºC) Value Parameter Symbol Min. Typ. Max. Unit Note Power Supply Voltage VCC 4.5 5 5.5 V (1) Rush Current IRUSH (2.1) A (2) White Pattern PT (4.13) (4.89) Watt Black Pattern PT (2.7) (3.03) Watt Power consumption Heavy Loading pattern Ex: Horizontal Stripe (by cell and platform) PT (4.10) (4.5) Watt White Pattern (0.82) (0.91) A Black Pattern (0.53) (0.61) A Power Supply Current Heavy Loading pattern Ex: Horizontal Stripe (by cell and platform) (0.76) (0.90) A (3) Differential Input High Threshold Voltage VLVTH +100 mV Differential Input Low Threshold Voltage VLVTL -100 mV Common Input Voltage VCM 1.0 1.2 1.4 V Differential input voltage (single-end) |VID| 200 600 mV LVDS interface Terminating Resistor RT 100 ohm (4) Input High Threshold Voltage VIH 2.7 3.3 V - CMIS interface Input Low Threshold Voltage VIL 0 0.7 V - Note (1) The module should be always operated within the above ranges. The ripple voltage should be controlled under 10% of Vcc(Typ.).
The copyright belongs to InnoLux. Any unauthorized use is prohibited Note (2) Measurement condition
The copyright belongs to InnoLux. Any unauthorized use is prohibited Note (3) The specified power supply current is under the conditions at Vcc = 12 V, Ta = 25 ± 2 ºC, fv = 60 Hz, whereas a power dissipation check pattern below is displayed. c. Horizontal Pattern Note (4) The LVDS input characteristics is shown as below : Active Area b. Black Pattern Active Area a. White Pattern
The copyright belongs to InnoLux. Any unauthorized use is prohibited 4. BLOCK DIAGRAM OF INTERFACE
4.1 TFT LCD OPEN CELL
(1366x3x768) X+C Board INPUT CONNECTOR, Foxconn GS23301-0321R-7H or P-TWO 187098-30091 GND Vcc SELLVDS RX0(+/-) RX1(+/-) RX2(+/-) RX3(+/-) CLK(+/-) SDA SCL
The copyright belongs to InnoLux. Any unauthorized use is prohibited 5. INPUT TERMINAL PIN ASSIGNMENT
5.1 TFT LCD OPEN CELL INPUT
CNF1 Connector Pin Assignment (GS23301-0321R-7H (Foxconn)187098-30091 (P-TWO)) Matting connectorFI-X30HL (JAE) Pin Name Description Remark 1 VCC +5.0V power supply - 2 VCC +5.0V power supply - 3 VCC +5.0V power supply - 4 VCC +5.0V power supply -
5 GND Ground -
6 GND Ground -
7 GND Ground -
8 NC No connection (2)
9 SELLVDS
LVDS data format Selection(0V~0.7VJEDIA, 2.7V~3.3V/Open VESA) Do Not Floating (3)
10 NC NC (2)
11 GND Ground -
12 RX0- Negative LVDS differential data input. Channel 0 - 13 RX0+ Positive LVDS differential data input. Channel 0 -
14 GND Ground -
15 RX1- Negative LVDS differential data input. Channel 1 - 16 RX1+ Positive LVDS differential data input. Channel 1 -
17 GND Ground -
18 RX2- Negative LVDS differential data input. Channel 2 - 19 RX2+ Positive LVDS differential data input. Channel 2 -
20 GND Ground -
21 RXLCK- Negative LVDS differential clock input. - 22 RXCLK+ Positive LVDS differential clock input. -
23 GND Ground -
24 RX3- Negative LVDS differential data input. Channel 3 - 25 RX3+ Positive LVDS differential data input. Channel 3 -
26 GND Ground -
27 NC No connection (2)
28 NC No connection (2)
29 NC No connection (2)
30 GND Ground -
Note (1) LVDS connector pin order defined as below.
The copyright belongs to InnoLux. Any unauthorized use is prohibited Note (2) Reserved for internal use. Please leave it open. Note (3) LVDS data format Selection(0V~0.7VJEDIA 2.7V~3.3V/OPENVESA) SELLVDS Mode 2.7V ~ 3.3V VESA 0V ~ 0.7V JEIDA Note (4) Interface optional pin has internal scheme as following diagram. Customer should keep the interface voltage level requirement which including Panel board loading as below: Note (5) LVDS connector mating dimension range request is 0.93mm~1.0mm as below. Note (6) The screw hole which is distant from the connector is merged with Ground. IC >16K ohm 1K ohm Panel Board System Board Interface Voltage Level VH > VIH VL < VIL 3.3V
The copyright belongs to InnoLux. Any unauthorized use is prohibited
5.2 LVDS INTERFACE
Open / 2.7V ~ 3.3V VESA 0V ~ 0.7V JEIDA VESA LVDS G3 G2G4 R5G0 R4 R3 R2 R1 B0 G5B1 B2B4 B3B5VS HSDE R6G6 R7G7B7 B6RSVD RXCLK ORX0 ORX1 ORX3 ORX2 Current G3 G2G4 R5G0 R4 R3 R2 R1 B0 G5B1 B2B4 B3B5VS HSDE R6G6 R7G7B7 B6RSVD ERX0 ERX1 ERX3 ERX2 G3 G2G4 R5G0 R4 R3 R2 R1 B0 G5B1 B2B4 B3B5VS HSDE R6G6 R7G7B7 B6RSVD RXCLK ORX0 ORX1 ORX3 ORX2 Current G3 G2G4 R5G0 R4 R3 R2 R1 B0 G5B1 B2B4 B3B5VS HSDE R6G6 R7G7B7 B6RSVD ERX0 ERX1 ERX3 ERX2 JEDIA LVDS Current G5 G4G6 R7G2 R6 R5 R4 R3 B2 G7B3 B4B6 B5B7VS HSDE R0G0 R1G1B1 B0RSVD RXCLK ORX0 ORX1 ORX3 ORX2 G5 G4G6 R7G2 R6 R5 R4 R3 B2 G7B3 B4B6 B5B7VS HSDE R0G0 R1G1B1 B0RSVD ERX0 ERX1 ERX3 ERX2 Current G5 G4G6 R7G2 R6 R5 R4 R3 B2 G7B3 B4B6 B5B7VS HSDE R0G0 R1G1B1 B0RSVD RXCLK ORX0 ORX1 ORX3 ORX2 G5 G4G6 R7G2 R6 R5 R4 R3 B2 G7B3 B4B6 B5B7VS HSDE R0G0 R1G1B1 B0RSVD ERX0 ERX1 ERX3 ERX2
The copyright belongs to InnoLux. Any unauthorized use is prohibited R0~R7Pixel R Data (7; MSB, 0; LSB) G0~G7Pixel G Data (7; MSB, 0; LSB) B0~B7Pixel B Data (7; MSB, 0; LSB) DEData enable signal DCLKData clock signal Notes: (1) RSVD (reserved) pins on the transmitter shall be “H” or “L”.
The copyright belongs to InnoLux. Any unauthorized use is prohibited
5.3 COLOR DATA INPUT ASSIGNMENT
The brightness of each primary color (red, green and blue) is based on the 8-bit gray scale data input for the color. The higher the binary input, the brighter the color. The table below provides the assignment of the color versus data input. Data Signal Red Green Blue Color R7 R6 R5 R4 R3 R2 R1 R0 G7 G6 G5 G4 G3 G2 G1 G0 B7 B6 B5 B4 B3 B2 B1 B0 Basic Colors Black Red Green Blue Cyan Magenta Yellow White Gray Scale Of Red Red (0) / Dark Red (1) Red (2) Red (253) Red (254) Red (255) Gray Scale Of Green Green (0) / Dark Green (1) Green (2) Green (253) Green (254) Green (255) Gray Scale Of Blue Blue (0) / Dark Blue (1) Blue (2) Blue (253) Blue (254) Blue (255) Note (1) 0: Low Level Voltage, 1: High Level Voltage
The copyright belongs to InnoLux. Any unauthorized use is prohibited
5.4 FLICKER (Vcom) ADJUSTMENT
(1) Adjustment Pattern The adjustment pattern is shown as below. If customer needs below pattern, please directly contact with INX account FAE. (2) Adjustment method: (Digital V-com) Programmable memory IC is used for Digital V-com adjustment in this model. INX provide Auto Vcom tools to adjust Digital V-com.The detail connection and setting instruction, please directly contact with Account FAE or refer INX Auto V-com adjustment OI. Below items is suggested to be ready before Digital V-com adjustment in customer LCM line. a. USB Sensor Board. b. Programmable software. c. Document: Auto V-com adjustment suggestion OI.
The copyright belongs to InnoLux. Any unauthorized use is prohibited 6. INTERFACE TIMING
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
The input signal timing specifications are shown as the following table and timing diagram. (Ta = 25 ± 2 ºC) Signal Item Symbol Min. Typ. Max. Unit Note Frequency Fclkin (=1/TC) 67.7 76 82 MHz - Input cycle to cycle jitter Trcl 200 ps (2) Spread spectrum modulation range Fclkin_mod Fclkin-2% Fclkin+2% MHz LVDS Receiver Clock Spread spectrum modulation frequency FSSM 200 KHz (3) Setup Time Tlvsu 600 ps LVDS Receiver Data Hold Time Tlvhd 600 ps Frame Rate Fr6 57 60 63 Hz Total Tv 776 806 1050 Th Tv=Tvd+Tvb Display Tvd 768 768 768 Th - Vertical Active Display Term Blank Tvb 8 38 282 Th - Total Th 1530 1560 2006 Tc Th=Thd+Thb Display Thd 1366 1366 1366 Tc - Horizontal Active Display Term Blank Thb 164 194 640 Tc - Note (1) Please make sure the range of frame rate has follow the below equation Fclkin(max) Fr6 Tv Th Fr5 Tv Th Fclkin(min)
The copyright belongs to InnoLux. Any unauthorized use is prohibited Tvd Tvb Tv Th Note (2) This module is operated in DE only mode and please follow the input signal timing diagram below INPUT SIGNAL TIMING DIAGRAM Note (3) The input clock cycle-to-cycle jitter is defined as below figures. Trcl = I T1 – TI Note (4) The SSCG (Spread spectrum clock generator) is defined as below figures. DE Thb Valid Display Data (1366 clocks) Tc DCLK Thd DE DATA
The copyright belongs to InnoLux. Any unauthorized use is prohibited Note (5) The LVDS timing diagram and setup/hold time is defined and showing as the following figures. LVDS RECEIVER INTERFACE TIMING DIAGRAM RXCLK+/- RXn+/- 11T 13T Tlvsu Tlvhd Tc
The copyright belongs to InnoLux. Any unauthorized use is prohibited 0.5T110ms 0T250ms 0T350ms 500ms T4 50% 50% T6 T5 T3 T1 0.1Vcc 0.1VCC T4 T2 VALID Power On P LVDS Signals Power ON/OFF Sequence Backlight (Recommended) 500msT5 100msT6 T7 T8 Option Signals (SELLVDS) 0T7T2 0T8T3
6.2 POWER ON/OFF SEQUENCE
(Ta = 25 ± 2 ºC) To prevent a latch-up or DC operation of LCD module, the power on/off sequence should be as the diagram below. Note (1) The supply voltage of the external system for the module input should follow the definition of Vcc. Note (2) Apply the lamp voltage within the LCD operation range. When the backlight turns on before the LCD operation or the LCD turns off before the backlight turns off, the display may momentarily become abnormal screen. Note (3) In case of Vcc is in off level, please keep the level of input signals on the low or high impedance. Note (4) T4 should be measured after the module has been fully discharged between power off and on period. Note (5) Interface signal shall not be kept at high impedance when the power is on. Note (6) Vcc must decay smoothly when power-off.
The copyright belongs to InnoLux. Any unauthorized use is prohibited 7. OPTICAL CHARACTERISTICS
7.1 TEST CONDITIONS
Ambient Temperature Ta 252 Ambient Humidity Ha 5010 %RH Supply Voltage Vcc 5 V Input Signal According to typical value in "3. ELECTRICAL CHARACTERISTICS" The LCD module should be stabilized at given temperature for 1 hour to avoid abrupt temperature change during measuring in a windless room. CS - 2000 500 mm LCD Module LCD Panel Field of View = 1º Light Shield Room (Ambient Luminance < 2 lux)
The copyright belongs to InnoLux. Any unauthorized use is prohibited
7.2 OPTICAL SPECIFICATIONS
The relative measurement methods of optical characteristics are shown in 7.2. The following items should be measured under the test conditions described in 7.1 and stable environment shown in 7.1. Item Symbol Condition Min. Typ. Max. Unit Note Rcx (0.660) - Red Rcy (0.325) - Gcx (0.273) - Green Gcy (0.590) - Bcx (0.135) - Blue Bcy (0.107) - Wcx (0.309) - Color Chromaticity White Wcy x=0, y =0 Viewing angle at normal direction Standard light source “C” Typ. -0.03 (0.351) Typ. +0.03 (1) Transmittance T% - (4.9) - % (6) Transmittance Variation T - - 1.42 (7) Contrast Ratio CR 2000 3000 - - (2),(4) Response Time Gray to gray x=0, Y =0 With INX Module@60Hz x+ 80 88 - Horizontal x- 80 88 - Y+ 80 88 - Viewing Angle Vertical CR20 With INX Module 80 88 - Deg. (2),(3) Note (1) Light source is the standard light source ”C” which is defined by CIE and driving voltage are based on suitable gamma voltages. The calculating method is as following 1.Measure Module’s and BLU’s spectrum at center point. W, R,G, B are with signal input. BLU(V185BJ1-LE1) is supplied by INX. 2.Calculate cell’s spectrum. 3.Calculate cell’s chromaticity by using the spectrum of standard light source “C”. Note (2) Light source is the BLU which supplied by INX (V185BJ1-LE1) and the cell driving voltage are based on suitable gamma voltages.
The copyright belongs to InnoLux. Any unauthorized use is prohibited Note (3) Definition of Viewing Angle (x, y) : Viewing angles are measured by Autronic Conoscope Cono-80 (or Eldim EZ-Contrast 160R). Note (4) Definition of Contrast Ratio (CR) The contrast ratio can be calculated by the following expression. Contrast Ratio (CR) = L0 of Luminance Surface L255 of Luminance Surface L255: Luminance of gray level 255 L 0: Luminance of gray level 0 CR = CR (5), where CR (X) is corresponding to the Contrast Ratio of the point X at the figure in Note(7). Note (5) Definition of Gray-to-Gray Switching Time The driving signal means the signal of gray level 0, 31, 63, 95, 127, 159, 191, 223 and 255.. Gray to gray average time means the average switching time of gray level 0, 31, 63, 95, 127, 159, 191, 223 and 255 to each other. 12 o’clock direction y+ = 90 6 o’clock y- = 90 x x y- y y- x+ Normal x = y = 0 X+ = 90 X- = 90 Optical Response 100% 90% 10% Gray to gray switching time Time Gray to gray switching time
The copyright belongs to InnoLux. Any unauthorized use is prohibited Note (6) Definition of Transmittance (T%) Measure the transmittance at 5 points. Light source is the BLU(V185BJ1-LE1) and the cell driving voltage are based on suitable gamma voltages. Transmittance (T%) = T(5)T(4),T(3),T(2),T(1), Average The transmittance of each point can be calculated by the following expression. T (X) = %100 BLU of (X) Luminance module LCD of (X) L1023 L1023: Luminance of gray level 1023 T(X) is corresponding to the point X1~X5 at the figure in Note (7). Note (7) Definition of Transmittance Variation (T) Measure the transmittance at 5 points. Transmittance Variation (T )= ] T(5) T(4), T(3), T(2), T(1), [ Minimum ] T(5) T(4), T(3), T(2), T(1), [ Maximum T(X) is calculated as Note(6). D W Active Area Vertical Line Horizontal Line : Test Point X=1 to 5 1 2 3 4 D/4 D/2 3D/4 W/4 W/2
The copyright belongs to InnoLux. Any unauthorized use is prohibited 8. PRECAUTIONS
8.1 ASSEMBLY AND HANDLING PRECAUTIONS
[ 1 ] Do not apply improper or unbalanced force such as bending or twisting to open cells during assembly. [ 2 ] It is recommended to assemble or to install an open cell into a customer’s product in clean working areas. The dust and oil may cause electrical short to an open cell or worsen polarizers on an open cell. [ 3 ] Do not apply pressure or impulse to an open cell to prevent the damage. [ 4 ] Always follow the correct power-on sequence when an open cell is assembled and turned on. This can prevent the damage and latch-up of the CMOS LSI chips. [ 5 ] Do not design sharp-pointed structure / parting line / tooling gate on the plastic part of a COF (Chip on film), because the burr will scrape the COF. [ 6 ] If COF would be bended in assemble process, do not place IC on the bending corner. [ 7 ] The gap between COF IC and any structure of BLU must be bigger than 2 mm. This can prevent the damage of COF IC. [ 8 ] The bezel opening must have no burr and be smooth to prevent the surface of an open cell scraped. [ 9 ] The bezel of a module or a TV set can not contact with force on the surface of an open cell. It might cause light leakage or scrape. [ 10 ] In the case of no FFC or FPC attached with open cells, customers can refer the FFC / FPC drawing and buy them by self. [ 11 ] It is important to keep enough clearance between customers’ front bezel/backlight and an open cell. Without enough clearance, the unexpected force during module assembly procedure may damage an open cell. [ 12 ] Do not plug in or unplug an I/F (interface) connector while an assembled open cell is in operation. [ 13 ] Use a soft dry cloth without chemicals for cleaning, because the surface of the polarizer is very soft and easily scratched. [ 14 ] Moisture can easily penetrate into an open cell and may cause the damage during operation. [ 15 ] When storing open cells as spares for a long time, the following precaution is necessary. [ 15.1 ] Do not leave open cells in high temperature and high humidity for a long time. It is highly recommended to store open cells in the temperature range from 0 to 35 at normal humidity without condensation. [ 15.2 ] Open cells shall be stored in dark place. Do not store open cells in direct sunlight or fluorescent light environment. [ 16 ] When ambient temperature is lower than 10ºC, the display quality might be reduced. [ 17 ] Unpacking (Cartons/Tray plates) in order to prevent open cells broken: [ 17.1 ] Moving tray plates by one operator may cause tray plates bent which may induce open cells broken. Two operators carry one carton with their two hands. Do not throw cartons/tray plates, avoid any impact on cartons/tray plates, and put down & pile cartons/tray plates gently. [ 17.2 ] A tray plate handled with unbalanced force may cause an open cell damaged. Trays should be completely put on a flat platform. [ 17.3 ] To prevent open cells broken, tray plates should be moved one by one from a plastic bag.
The copyright belongs to InnoLux. Any unauthorized use is prohibited [ 17.4 ] Please follow the packing design instruction, such as the maximum number of tray stacking to prevent the deformation of tray plates which may cause open cells broken. [ 17.5 ] To prevent an open cell broken or a COF damaged on a tray, please follow the instructions below: [17.5.1] Do not peel a polarizer protection film of an open cell off on a tray [17.5.2] Do not install FFC or LVDS cables of an open cell on a tray [17.5.3] Do not press the surface of an open cell on a tray. [17.5.4] Do not pull X-board when an open cell placed on a tray. [ 18 ] Unpacking (Hard Box) in order to prevent open cells broken: [ 18.1 ] Moving hard boxes by one operator may cause hard boxes fell down and open cells broken by abnormal methods. Two operators carry one hard box with their two hands. Do handle hard boxes carefully, such as avoiding impact, putting down, and piling up gently. [ 18.2 ] To prevent hard boxes sliding from carts and falling down, hard boxes should be placed on a surface with resistance. [ 18.3 ] To prevent an open cell broken or a COF damaged in a hard box, please follow the instructions below: [18.3.1] Do not peel a polarizer protection film of an open cell off in a hard box. [18.3.2] Do not install FFC or LVDS cables of an open cell in a hard box. [18.3.3] Do not press the surface of an open cell in a hard box. [18.3.4] Do not pull X-board when an open cell placed in a hard box. [ 19 ] Handling – In order to prevent open cells, COFs , and components damaged: [ 19.1 ] The forced displacement between open cells and X-board may cause a COF damaged. Use a fixture tool for handling an open cell to avoid X-board vibrating and interfering with other components on a PCBA & a COF. [ 19.2 ] To prevent open cells and COFs damaged by taking out from hard boxes, using vacuum jigs to take out open cells horizontally is recommended. [ 19.3 ] Improper installation procedure may cause COFs of an open cell over bent which causes damages. As installing an open cell on a backlight or a test jig, place the bottom side of the open cell first on the backlight or the test jig and make sure no interference before fitting the open cell into the backlight/the test jig. [ 19.4 ] Handle open cells one by one. [ 20 ] Avoid any metal or conductive material to contact PCB components, because it could cause electrical damage or defect.
8.2 SAFETY PRECAUTIONS
[ 1 ] If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In case of contact with hands, skin or clothes, it has to be washed away thoroughly with soap. [ 2 ] After the module’s end of life, it is not harmful in case of normal operation and storage.
The copyright belongs to InnoLux. Any unauthorized use is prohibited 9. DEFINITION OF LABELS
9.1 INX MODULE LABEL
The barcode nameplate is pasted on each open cell as illustration for INX internal control. Figure.9-1 Serial No. Label on SPWB and Cell Model Name : V185BJ1-PE1 Revision : Rev. XX, for example: A0, A1… B1, B2… or C1, C2… etc. Serial ID : X X X X X X X Y M D L N N N N Serial ID includes the information as below: Manufactured Date: Year: 2010=0, 2011=1,2012=2… etc. Month: 1~9, A~C, for Jan. ~ Dec. Day: 1~9, A~Y, for 1st to 31st, exclude I ,O, and U. Revision Code: Cover all the change Serial No.: Manufacturing sequence of product X X X X X X X Y M D L N N N N V185BJ1– PE1 Rev. XX INX Internal Use Year, Month, Date INX Internal Use Revision Serial No.
The copyright belongs to InnoLux. Any unauthorized use is prohibited Figure.9-2 Panel ID Label on Cell Panel ID Label includes the information as below : Panel ID: T X X X X X X X X X X X TXXXXXXXXXXX TFT INX Internal Use FAB Line: 1~8, for Fab1~Fab8
The copyright belongs to InnoLux. Any unauthorized use is prohibited 10. PACKAGING
10.1 PACKING SPECIFICATIONS
(1) 15pcs LCD TV Panels / 1 Box (2) Box dimensions530mm (L) x 385mm (W) x 93mm (H) (3) Weightapproximately (6.6Kg) (4) 900pcs LCD TV Panels / 1 Group (5) Without the outer carton, Boxes stack under the package architecture
10.2 PACKAGING METHOD
Packing method (Hard Box) is shown in following figures. Figure.10-1 packing method
The copyright belongs to InnoLux. Any unauthorized use is prohibited Figure 10-2 packing method
The copyright belongs to InnoLux. Any unauthorized use is prohibited
10.3 UN-PACKAGING METHOD
Unpacking method (Hard Box) is shown in following figures. Figure 10-3 UN-packing method
The copyright belongs to InnoLux. Any unauthorized use is prohibited 11. MECHANICAL CHARACTERISTIC