SDU500 ETC1 | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Features

  • Lightweight, compact industrial design
  • Wide operation temperature range (0 0C to 500C)
  • Cold start capability
  • Phone/dataline surge protection
  • Software and cable included for easy installation
  • Simulated sinewave output
  • RS232 communication port
  • USB communication port (optional)
  • Form C dry contact relay (optional)
  • Panel/wall mounting brackets (optional)
  • Remote turn-on and shut-off capabilities
  • Two year limited warranty SDU Series, DIN Rail AC UPS Selection Table Certifications and Compliances All Models - Low Voltage Directive: EN62040-1: 2008/A1: 2013 - EMC Directive: EN62040-2: 2006 SDU 500, SDU 850 Models UL 60950 E137632 CUL/CSA-C22.2 No. 234-M90 UL Recognized Component, UPS Equipment - UL 1778, CSA C22.2 No. 107.3 - Suitable for UL 508 with no VA derating and CSA C22.2 No. 107.1 Ind. Control Equipment Applications - Overvoltage Cat III, Pollution Degree III

Related Products

  • Portable MCR Power Conditioners
  • STV Surge Protective Devices
  • SDN DIN Rail Power Supplies
  • STFV Plus Active Tracking ® Filters SDU Accessories Capacity (VA/W) Catalog Number Volts, Frequency In/Out Typical Back-up Time (minutes) * Input/Output Connections Approx. Ship Weight - lbs (kg) 500/300 SDU 500

120 Vac, 50/60 Hz

IP20 touch proof, screw terminals. Wire range: 10 ~ 24 AWG. 10.7 (4.70) 850/510 SDU 850 2 11.4 (5.00) 500/300 SDU 500-5

230 Vac, 50/60 Hz

4 11.5 (5.20) 850/510 SDU 850-5 2 11.9 (5.40) E179213 * At full load. Catalog Number Description Approx. Ship Weight - lbs (kg) RELAYCARD-SDU Dry contact I/O relay box, IP20 touch proof screw terminals, wire size range 12~22 AWG (IEC 2.5mm); UPSMON-USB RS232 to USB adapter cable 1.0 (0.45) SDU-PMBRK Mounting brackets to secure UPS to wall, back of panel or enclosure. 1.0 (0.45)

2Uninterruptible Power Systems Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. Specifications Catalog Number SDU 500 SDU 850 SDU 500-5 SDU 850-5 Capacity (VA/Watts) 500/300 850/510 500/300 850/510 Load Power Factor 0.6 Dimensions - inches (mm) Input Parameters Frequency 50 +/- 5 Hz or 60 Hz +/- 6 Hz (auto sensing) Output AC Parameters Voltage (Battery Mode) Step sinewave +/- 5% Frequency (On Battery) 50 or 60 Hz +/- 0.3 Hz Overload Protection UPS automatic shutdown if overload exceeds 105% of nominal at 20 seconds, 120% at 10 seconds, 130% at 3 seconds Short Circuit UPS output cut off immediately Battery Parameters Battery Type Sealed, non-spillable, maintenance-free lead acid batteries Transfer Time 4 - 6 ms typical Back-up Time * (minutes) 4.5/18 2.5/10 4.5/18 2.5/10 Recharge Time 8 hours to 90% capacity after full discharge Environmental Operating Temperature 0°C to 50°C Storage Temperature -15°C to 60°C Relative Humidity 1% to 95%, non-condensing Ambient Operation 1-95% humidity non-condensing, 0-50°C up to 5,000 ft. (1500m) Audible Noise < 40dBA (1 meter from surface) Standards EMC FCC Part 15, Subpart B, Class A; EMC: EN62040-2; EN55022; CISPR22; Elevation 5000 ft. without derating Shock & Vibration According to the International Safe Transit Association standard ISTA 2A. Mounting To be mounted on DIN TS35/7.5 or TS35/15 rail system. Chassis mounting permissible via optional brackets. Unit handles normal shock and vibration of industrial use and transportation without coming off rail. * At full load/half load.