UPS30-4003 ETC2 | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Rated Tolerance Min Rated Max (3) Load Line Min Nom Max 90 260 47 63 20A 40A 40K Hz. 2A, Slow-blow 115/230 VAC Non-User Serviceable Operation Storage Main +5V exceeds 6.8V causes shutdown. Automatic Recovery Triple Output 5V/12V/-12V 30W (1) GENERAL SPECIFICATIONS Switching Frequency Inrush Current At Min 115 VAC Max 230 VAC OUTPUT Overload Protection All outputs protected against short circuit conditions, automatic recovery. INPUT Overvoltage Protection Voltage AC Frequency Universal AC Fusing Efficiency at full Load 120VAC 68%min at Full Load 120 VAC Open Frame 2.76"X5.12" Universal Input AC/DC Converter Regulation (4)Ripple & Noise Model UPS30-4003 Voltage Current Environmental EMI Safety, Regulatory & EMI Temperature coefficient Temperature Range Agency Approvals 0.02%/oC, All outputs 0 to 50oC at rated output power. Derates linearly to 50% power at 70oC. -55oC to 85oC Meets F.C.C part 15 class 'B' conducted. UL60950 CSA C22.2 E.B.1802C TUV EN60950 Autec Power Systems 685 E Cochran St, Simi Valley, CA93065 www.autec.com Tel: (805)522-0888 Fax: (805)522-8777

NOTES: 1. Total peak power must not exceed the value indicated with each output not exceeding its peak current rating. The power supply may be capable of providing more than the specified continuous and/or peak ratings. Consult a factory Sales Engineer for feasibility. 2. Minimum load specified assures output voltage stability for all specified line voltage conditions. Full compliance to the total regulation specification may require additional loading (not to exceed 25% of rated output current). Operation at no load will not damage the power supply. 3. Each output can provide its full rated output current, provided total wattage does not exceed nominal (continuous) rating. 4. Peak Power is available for 30 seconds maximum with a 10% duty cycle. 5. Total regulation includes the combined effects of: a) initial set point of main output of ± 1% max; b) line regulation for any input voltage change between 90 & 264 VAC; c) load regulation for a MIN. –100% of rated continuous load change: assumes that the total continuous power rating of the supply is not exceeded. [See Note3]. Performance during peak loading conditions is not included in the figure. 6. Specifications are subject to change without notice. AUTEC cannot be held liable for errors or omissions or the consequences thereof. CN1 CN2 AC INPUT DC OUTPUT PIN 1 NEUTRAL +5V PIN 2 N/C +5V PIN 3 LINE COM PIN 4 COM PIN 5 -12V PIN 6 +12V MOLEX (or equiv) 09-65-2038 09-65-2068 Mating Connector 09-50-1031 09-50-1061 CONNECTOR PIN ASSIGNMENTS UPS30-4003 WIDTH LENGTH HEIGHT inch 2.76 5.12 1.16 mm 70.2 127.0 29.5 inch 2.38 4.72 N/A mm 60.0 120.0 N/A UPS30-4003MOUNTING OUTLINE SHIPPING SPECIFICATIONS MODEL UNITS PER CARTON UPS30-4003 64.0 CARTON WEIGHT 14 Kgs 30.9 Lbs Autec Power Systems 685 E Cochran St, Simi Valley, CA93065 www.autec.com Tel: (805)522-0888 Fax: (805)522-8777