Rev. 07.18.11_10 µMP Series 1 of 6 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 Embedded Power for Business-Critical Continuity Electrical Specifications Input Input ra nge: 85 - 264 Vac, 120 - 350 Vdc (limited to 250 Vac/300 Vdc in medical apps) Frequency: 47 - 440 Hz Inrush current: 40 A peak max. (soft start) Efficiency: Up to 91% @ full case load Power Factor: 0.99 typ. meets EN61000-3-2 (n/a @ 440 Hz) Turn-on time: AC on 2 sec for uMP1 and 1.5 sec for uMP4, inhibit/enable 250 ms typical EMI filter: CISPR 22/EN55022 Level “B” Leakage current: 300 µA max. @ 240 Vac for uMP1 and 500 µA max for uMP4; 47 - 63 Hz Radiated EMI: CISPR 22/EN55022 Level “B” Holdover storage: 16.7 ms minimum (independent of input Vac, 0 °C to 50 °C)) AC OK: Signal goes low indicating loss of AC input. Hold up = Full cycle ride thru (50 Hz) Harmonic distortion: Meets EN61000-3-2 Isolation: Meets EN60950 and EN60601 Global Inhibit/Enable: TTL, Logic “1” and Logic “0”; fan off when unit is inhibited Input fuse (internal): uMP1: 16 A/250 V TLAG, uMP4: 10 A / 250 V. (both lines fused) Warranty: 2 years µMP Series Up to 1200 Watts Special Features
- Full Medical EN60601 approval
- PMBus
- High efficiency
- Current limit modification (foldback or constant current)
- High power density. uMP4: 10.8 W/cu-in uMP1: 15.1 W/cu-in
- Intelligent fan (speed control/fault status)
- Downloadable GUI from website
- uP controlled PFC input with active inrush protection
- Optional conformal coating
- Industrial temp range (-40 ºC to 70 ºC)
- No preload required
- Industrial shock/vibration (> 50G’s)
- Low cost
- IEC or t erminal b lock in put
- Low p rofile 1U si ze Total Power: Up to 1200 Watts Input Voltage: 85 - 264 Vac 120-300 Vdc # of Outputs: Up to 12 Safety
- UL UL60950/UL60601-1
- CSA CSA22.2 No. 234 Level 5
- VDE EN60950/EN60601-1
- BABT Compliance to EN60950/EN60601 BS7002
- CB Certificate and report
- CE Mark to LVD
- CCC Approved
- BSMI Approved MicroMP 1U Multi Output Operating temperature: -40 ° to 70 °C ambient. Derate each output 2.5% per degree from 50 °C to 70 °C. ( -20 °C start up). Meets full spec after 1/2 load. 10 min warm-up Storage temperature: -40 °C to 85 °C Electromagnetic susceptibility: Designed to meet EN61000-4; -3, -6, -11 Level 3, Level 4 for -2, -4, -5 Humidity: Operating; non-condensing 10% to 95% RH Vibration: MIL-STD-810E MTBF demonstrated: > 350,000 hours at full load, one uMP4 case + two modules, Telcordia SR-332 calculated MTBF Altitude: Up to 10k feet; derate linear to 50% from 10k-30k feet Environmental Specifications µMP4C shown
Rev. 07.18.11_10 µMP Series 2 of 6 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 Output Factory set point accuracy: ± 1% Margining: ± 3 - 7% nominal analog (single output module only) Overall regulation: 0.4% or 30 mV which ever is greater. Ripple: RMS: 0.1% or 10 mV, whichever is greater Pk-Pk: 1.0% or 50 mV, whichever is greater. Bandwidth limited to 20 MHz Dynamic response: < ± 5% or 250 mV, with 50% step load Recovery time: To within 1% in < 300 µsec Reverse voltage protection: 100% of rated output current Thermal protection: (OTP) All outputs disabled when internal temp exceeds safe operating range. Remote sense: Up to 0.5 V total drop (not available on triple output module) Single wire parallel: Current share to within 5% of total rated current DC OK: ± 5% of nominal. Minimum load: Not required Housekeeping standby: 5 Vdc @ 1.0 A max. present whenever AC input is applied Module inhibit: Logic - output on with low or open. Different logic options available Output/Output isolation: > 1 Megohm, 500 V Vout Full load (A) OVP trip max (V) OCP trip typ (I- out%) SCP trip max (I- out%) Overshoot (max mV) Peak Deviation (max mV) 3V3 Module 0.9 40 TBD 130% 160% 150 ± 250 3.3 40 5.96 V 130% 160% 250 ± 250 3.6 40 6.32 V 130% 160% 250 ± 250
5 V Module
3.2 36 6.8 V 130% 160% 250 ± 250 5 36 8.8 V 130% 160% 250 ± 250 6 30 9.2 V 130% 160% 300 ± 300
12 V Module
6 25 12 V 130% 160% 300 ± 300 12 20 18 V 130% 160% 600 ± 600 15 16 20 V 130% 160% 750 ± 750
24 V Module
12 13 18 V 130% 160% 600 ± 600 24 10 31 V 130% 160% 1200 ± 1200 30 8 38 V 130% 160% 1500 ± 1500
48 V Module
28 7 TBD 130% 200% 1400 ± 1400 48 5 TBD 130% 160% 2400 ± 2400 60 4 TBD 130% 200% 3000 ± 3000 Case Line-Up Case Max Output Dimensions Connections Max Current Amps (10.11” x 3.5” x 1.57”) IEC/Terminal Block 9.91 (10.11” x 5” x 1.57”) IEC/Terminal Block 13.87 Output Module Line-Up Output Range (Vdc) Max Current (Amps) Max Power (Watts) Module Codes Standard Outputs 6.0 - 15.0 25 240 I, J, K, L, M, N - 8, 10, 11, 12, 14, 15 12.0 - 30.0 13 240 O, P, Q, R, S - 18, 20, 24, 28, 30 28.0 - 54.0 7 240 T, U, V, W, X, Y - 28, 30, 33, 36, 42, 48, 54, 60 5.0 - 28.0 5.0 - 28.0 Dual Output Module. Each output is rated to 96W (192 Watts total). Wide range is adjustable.
Rev. 07.18.11_10 µMP Series 3 of 6 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 µMPXY - S2E - DER - DLL - 00 - A - ### Case Option Codes First digit 0 - E = Parallel Code Second digit 0 = No Options 1 = Reverse Air 3 = Global Enable 5 = Opt 1 + Opt 3 Software CodeCase Option Codes Factory assigned for modified standards Module Codes S2 = 200 W Single O/P (1 slot) D = 96 W/96 W Dual O/P Common Ground (1 slot) I = 96 W/96 W Dual O/P Isolated Ground (1 slot) Voltage Codes: See Voltage Code Table Module/Voltage/Option Codes Case Size Single - Phase Input where X = 4 = 1.57” x 3.5” x 10”; 400 W - 600 W, 4 Slots 1 = 1.57” x 5” x 10”; 1000 W - 1200 W, 6 Slots Input Type where Y = T = Terminal Block C = IEC Connector, C14 B = IEC Connector, C16 Case Size Factory assigned for modified standards Hardware Code Standard Output Ratings Module Output Voltage Code Single Output ONE SLOT
240 Watts Max
192 Watts Max
Module Identification S2 D = Dual Common Ground I = Dual Isolated Ground Voltage Codes Output Module Line-Up Code Volts Output Current Output Current V1 V2 A 2.0 V 40.0 N/A B 2.2 V 40.0 N/A C 3.0 V 40.0 N/A E 5.0 V 36.0 4.0 4.0 F 5.2 V 34.0 4.0 4.0 G 5.5 V 32.0 4.0 4.0 H 6.0 V 30.0 4.0 4.0 I 8.0 V 25.0 4.0 4.0 J 10.0 V 24.0 4.0 4.0 K 11.0 V 22.0 4.0 4.0 L 12.0 V 20.0 4.0 4.0 M 14.0 V 17.0 4.0 4.0 N 15.0 V 16.0 4.0 4.0 O 18.0 V 13.0 4.0 4.0 P 20.0 V 12.0 4.0 4.0 Q 24.0 V 10.0 4.0 4.0 R 28.0 V 8.6 3.4 3.4 S 30.0 V 8.0 N/A T 33.0 V 7 N/A U 36.0 V 6.7 N/A V 42.0 V 5.7 N/A W 48.0 V 5.0 N/A X 54.0 V 4.4 N/A Y 60.0 V 4.0 N/A * For “I” codes only Derating Curves - µMP1 400 500 600 700 800 900 1000 1100 1200 01 02 03 04 05 06 07 0 Output Power Temperature Standard Fan(12 V/24 V/48 V)
85 VAC 100 VAC 110 VAC 200 VAC 264 VAC
Reverse FAN(12 V/24 V/48V) Code Slots in Parallel Code Slots in Parallel Code Slots in Parallel 5 5&6 A 1&2; 3&4 0 no module in parallel
µMP1 = 6 available slots 1000 W max. 1200 W max.
1 AC neutral
2 AC line (hot)
3 Chassis (earth) ground
1 Input AC OK - “emitter”
2 Input AC OK - “collector”
3 Global DC OK - “emitter”
4 Global DC OK - “collector”
5 Spare
6 Global inhibit/optional enable logic “1”
7 Global inhibit/optional enable logic “0”
8 Global inhibit/optional enable return
2 Serial data signal (SDA)
3 Secondary return (COM)
4 Serial clock signal (SCL)
5 Address bit 2 (A2)
6 No connection
7 Address bit 1 (A1)
8 No connection
9 Address bit 0 (A0)
10 No connection
Figure 1. AC Input Figure 2. Connector J1 & J2 µMP4 =4 available slots 400 W max. 600 W max.
12.5 MAX
3.0 MAX
1 No connection
2 No connection
3 Current share
4 Module inhibit return
5 Module ISO inhibit
6 SCOM
8 Margin
3 No connection
4 Module inhibit rtn
9 No connection
2.5 MAX
Rev. 07.18.11_10 µMP Series 5 of 6 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375 240 µMP Series µMP4 (400/600 Watts Max)
- Blank: 0.06 lb.
Rev. 07.18.11_10 µMP Series 6 of 6 Embedded Power for Business-Critical Continuity 313 process yellow 3405 1797 1375 116 2607 652 242 2985 375
240 Americas
5810 Van Allen Way
Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Europe (UK) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Asia (HK) 14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888 For global contact, visit: www.Emerson.com/EmbeddedPower techsupport.embeddedpower @emerson.com While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2011 Emerson Electric Co. EmersonNetworkPower.com Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Case Size: µMP1: 10.11” x 5” x 1.57” (256.9mm x 127mm x 40.0mm) Weight: µMP1 Case: 2.78 lbs • Single O/P: 0.22 lb.
- Dual O/P: 0.16 lb. • Blank: 0.06 lb. µMP Series µMP1 (1000/1200 Watts Max)