- 1 SP1ML firmware upgrade
- 2 Set up quick data exchange between two SP1ML modules
- 3 Revision history
microcontroller, in a compact surface-mount module form-factor. The UART host interface allows simple connection to an external microcontroller. Access to module features is provided through an extended AT command set. Figure 1. SP1ML module
1 SP1ML firmware upgrade
the latest version of the FW (available on request).
- STEVAL-SP1ML evaluation board or
- SP1ML module (wired with USB/UART converter)
Figure 2. STEVAL-SP1ML
- Download “CP210x USB to UART Bridge VCP Drivers” (STEVAL-SP1ML is using CP2102 USB/UART converter, so driver must be installed)
- Install the ST Flash loader demonstrator: www.st.com/stm32-flash-loader
- Ensure that you have the latest SP1ML FW from ST Documentation
- Ensure that you have the latest version of the SP1ML datasheet (including AT command set) and STEVAL-SP1ML data brief available on st.com (www.st.com\\subghzmodules). Settings
- In order to force boot mode, the boot0 pin must be set to “1”. On the STEVAL-SP1ML it can be achieved through JP1 or by connecting PAD10 and PAD11 together.
Figure 3. STEVAL-SP1ML JP1 connector
- Select the COM port associated with CP2102
- Baud rate 115200
- Select target: STM32L_Med-density-128K
- Download address must be set to 0x8000000 FW upgrade
- Reset the module (or plug in the STEVAL-SP1ML) with the boot0 pin set to “1”
- Launch the FW upgrade procedure using the Flash loader settings described above.
Figure 4. Flash loader demonstrator
2 Set up quick data exchange between two SP1ML
- Connect two dongles to the PC USB port.
- Open 2 HyperTerminal sessions on the PC and connect to each dongle with associated COM port (115200 Baud rate, local echo, CR+LF for Tx/Rx)
- By default, the module is in operation mode. In order to move it in command mode, the “+++” escape sequence must be used.
- Using the “AT/S” command will then provide the module setting list
- Please refer to the command list provided in the SP1ML datasheet.
Figure 5. HyperTerminal
- S15 should be set to 0x00 (using HyperTerminal write ATS15=0x00)
- S16 should be set to 0x01 (using HyperTerminal write ATS16=0x01)
- Then send AT/C to store settings and ATO to move into operation mode Dongle/Module2
- S15 should be set to 0x01 (using HyperTerminal write ATS15=0x01)
- S16 should be set to 0x00 (using HyperTerminal write ATS16=0x00)
- Then send AT/C to store settings and ATO to move into operation mode
Set up quick data exchange between two SP1ML modules UM1889 Data exchange/cable replacement
- Now each module is in operating mode
- Any data written in HyperTerminal 1 (Dongle/Module1) will be received in HyperTerminal 2 (Dongle/Module2).
- Any data written in HyperTerminal 2 (Dongle/Module2) will be received in HyperTerminal 1 (Dongle/Module1).
3 Revision history
Table 1. Document revision history 24-Apr-2015 1 Initial release.