UFA2405MP-6W MORNSUN | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

MORNSUN reserves the copyright Specifications subject to change without notice. UFA_MP-6W & UFB_MP-6W A/2-2008 Page 1 of 2 UFA_MP-6W & UFB_MP-6W Series 6W, WIDE INPUT, ISOLATED & REGULATED DUAL & SINGLE OUTPUT, DC-DC CONVERTER multi-country patent protection RoHS PRODUCT PROGRAM Input Output Voltage (VDC) Current (mA) Part Number Nominal Range Max** Voltage (VDC) Max Min Efficiency (%, Typ) UFA2405MP-6W ±5 ±600 ±60 80 UFA 2412MP-6W ±12 ±250 ±25 80 UFA 2415MP-6W ±15 ±200 ±20 82 UFA 2424MP-6W ±24 ±125 ±13 85 UFB2403MP-6W 3.3 1500 150 78 UFB2405MP-6W 5 1200 120 80 UFB2412MP-6W 12 500 50 82 UFB2415MP-6W 15 400 40 82 UFB2424MP-6W 24 9-36 40 24 250 25 83 UFA4805MP-6W * ±5 ±600 ±60 80 UFA4812MP-6W ±12 ±250 ±25 82 UFA4815MP-6W ±15 ±200 ±20 84 UFA4824MP-6W ±24 ±125 ±13 85 UFB4803MP-6W * 3.3 1500 150 76 UFB4805MP-6W 5 1200 120 80 UFB4812MP-6W 12 500 50 84 UFB4815MP-6W 15 400 40 85 UFB4824MP-6W 48 18-75 80 24 250 25 86 * Designing. * * Input voltage can’t exceed this value, or will cause the permanent damage. Note: The load shouldn't be less than 10%, otherwise ripple will increase dramatically. Operation under 10% load will not damage the converter; However, they may not meet all specification listed. OUTPUT SPECIFICATIONS Item Test Conditions Min Typ Max Units Output Power See below products program 6 W Line Regulation(at full load) Input voltage from low to high ±0.2 ±0.5 Load Regulation From 10% To 100% load ±0.5 ±2* Positive Voltage Accuracy Refer to recommended circuit ±1 ±3 Negative Voltage Accuracy Refer to recommended circuit ±3 ±5 Temperature Drift(Vout) Refer to recommended circuit 0.02 %/ °C Ripple 20MHz bandwidth 30 50 Noise 20MHz bandwidth 100 300 mVp-p Switching Frequency 100% load, nominal Input voltage 300 KHz * Dual output models unbalanced load: ±5%. **Test ripple and noise by “parallel cable” method. See detailed operation instructions at Testing of Power Converter section, application notes.

FEATURES

Efficiency up to 86% Wide (4:1) Input Range 1.5KVDC Input/Output Isolation Continuous Short Circuit Protection Operating Temperature: -40°C to +85°C Internal SMD construction Metal Shielding Package No Heat Sink Required Industry Standard Pinout MTBF>1,000,000 hours RoHS Compliance

APPLICATIONS

The UFA_MP-6W & UFB_MP-6W Series are specially designed for applications where a wide range input voltage power supplies are isolated from the input power supply in a distributed power supply system on a circuit board. These products apply to: 1) Where the voltage of the input power supply is wide range (voltage range≤4:1); 2) Where isolation is necessary between input and output(Isolation Voltage≤1500VDC); 3) Where the regulation of the output voltage and the output ripple noise are demanded. MODEL SELECTION UFA2405MP-6W Product Series Input Voltage Output Voltage Package Style Rated Power MORNSUN Science& Technology co.,Ltd. Address: 2th floor 6th building, Huangzhou Industrial District, Guangzhou, China Tel: 86-20-38601850 Fax: 86-20-38601272 Http://www.mornsun-power.com

MORNSUN reserves the copyright Specifications subject to change without notice. UFA_MP-6W & UFB_MP-6W A/2-2008 Page 2 of 2 COMMON SPECIFICATION APPLICATION NOTE Item Test Conditions Min Typ Max Units Storage humidity 95 % Operating temperature -40 85 Storage temperature -55 125 Temp. rise at full load 40 Lead temperature 1.5mm from case for 10 seconds 300 Isolation voltage Tested for 1 minute and 1mA max 1500 VDC Isolation resistance Test at 500VDC 1000 M Ω Cooling Free air convection Short circuit protection Continuous, automatic recovery Case material Copper, Nickel Plated MTBF 1000 K hours Weight 17 g Note: 1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. See below recommended circuits for more details. TYPICAL CHARECTERISTICS Operating Temp.( )C Temperature Derating Graph OUTLINE DIMENSIONS & PIN CONNECTIONS 23911 14162223 32.00 20.0010.00 2.54 (1.260) (0.787) (0.394) (0.100) 4.10 2,3 22,23 GND NC +Vo Vin GND -Vo +Vo Vin RECOMMENDED FOOTPRINT Top view,grid:2.54mm(0.1inch), diameter:1.00mm(0.039inch) Note: Unit:mm(inch) Pin diameter:0.50mm(0.020inch) Pin diameter tolerances:0.05mm(0.002inch) General tolerances:0.25mm(0.010inch) Dual Output Single Output First Angle Projection FOOTPRINT DETAILS Pin Single Dual NC:No Connection NP COM COM 10.00 (0.020) 0.50 Bottom View Side View 2 3 9 11 14162223 2 3 11 14162223 Recommended Circuit All the UFA_MP-6W & UFB_MP- 6W Series have been tested acco rding to the following recommended testing circuit before leaving factory. This series should be tested under load. Never be tested under no load (see Figure 1). DC DC Vin GND +Vout Cin Vin GND +Vout 0VCin DCDC -Vout Dual Output Single Output (Figure 1) If you want to further decrease the output rippl e, you can increase capacitance properly or choose capacitors with low ESR. However, the capacitance should not be too high.(Table 1). External Capacitor Table(Table 1) Vin (VDC) Cin (uF) Single Vout (VDC) Cout (uF) Dual Vout (VDC) Cout (uF) 24 100 5 100 ±5 100 48 100 12 100 ±12 47 -- -- 15 47 ±15 47 -- -- 24 47 ±24 22