1© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Built Into Tomorrow Benefits
- Low power consumption (< 140 mW)
- Super compact and lightweight
- Flat package for dense mounting
- Low magnetic interference
- Tube or embossed tape and reel packaging
- UL recognized (E73266) and CSA certified (LR46266)
- Surface mount and through-hole options Overview The KEMET UC2/UD2 miniature signal relays offer a super compact case size in a flat package. Minimal board space is consumed with either a through-hole or surface mount configuration. These relays are recognized by UL and CSA, while also being compliant with Part 68 of the FCC’s 1,500 V surge capacity.
Applications
- Electronic switching systems
- PBX
- Terminal equipment
- Telephone systems Miniature Signal Relays UC2/UD2 Part Number System UD2- 3 S NU -L Series Coil Voltage Latch Type Lead Type Packaging UC2- = Through-hole mount UD2- = Surface mount 3 = 3 VDC 4.5 = 4.5 VDC 5 = 5 VDC 9 = 9 VDC 12 = 12 VDC Blank = Non-latch type S = Single coil latch type NU = Standard NE = Low power consumption (Non-latch) NJ = Trimmed NUN = Minimum footprint NEN = Low power consumption (Non-latch), Minimum footprint Blank = Tube -L = Embossed tape on reel
2© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Dimensions – Millimeters UC2 Series B Maximum 0.2 D Maximum H Maximum 0.4 P1P13.2 1.5 1.5 D Maximum H Maximum K0.4 P1P13.21.5 1.5 0.2 B Maximum K UD2 Series B Maximum 0.2 D Maximum H Maximum 0.4 P1P13.2 1.5 1.5 D Maximum H Maximum K0.4 P1P13.21.5 1.5 0.2 B Maximum K Series D H B P1 P2 P3 K General tolerance: ±0.3 Tolerance of lead pitch: ±0.15
3© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Pin Configurations Bottom view RS S: Coil polarity for Set R: Coil polarity for Reset 1 2 3 4 8 7 6 5 Single coil latch type (Reset position) Non-latch type (Non-energized position) 1 2 3 4 8 7 6 5 Direction mark Direction mark Safety Standards and Ratings Certification Body Mark Specification File Number Rating UL UL Recognized (UL508)1 E73266 30 VDC, 1 A (resistive) 110 VDC, 0.3 A (resistive) 125 VAC, 0.5 A (resistive)CSA CSA Certified (CSA 22.2 #14)2 LR46266
1 Spacing: UL840
2 Spacing: CSA std950
Certification Body Mark Specification File Number Class Rating TUV TUV Certified (EN61810) 2050596 Basic insulation Creepage and clearance of coil to contact is more than 2 mm (According to EN60950) Environmental Compliance All KEMET relays are RoHS Compliant.
4© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Table 1 – Ratings & Part Number Reference Part Number Nominal Coil Voltage Lead Type Packaging () Designates Latch Type (VDC) UC2-3(1)NU 3.0 Radial Tube UC2-4.5(1)NU 4.5 Radial Tube UC2-5(1)NU 5.0 Radial Tube UC2-12(1)NU 12.0 Radial Tube UC2-3(1)NJ 3.0 Radial Tube UC2-4.5(1)NJ 4.5 Radial Tube UC2-5(1)NJ 5.0 Radial Tube UC2-9(1)NJ 9.0 Radial Tube UC2-12(1)NJ 12.0 Radial Tube UC2-3NE 1 3.0 Radial, Low power consumption Tube UC2-4.5NE 1 4.5 Radial, Low power consumption Tube UC2-5NE 1 5.0 Radial, Low power consumption Tube UD2-3(1)NU 3.0 Surface mount Tube UD2-4.5(1)NU 4.5 Surface mount Tube UD2-5(1)NU 5.0 Surface mount Tube UD2-12(1)NU 12.0 Surface mount Tube UD2-3NE 1 3.0 Surface mount, Low power consumption Tube UD2-4.5NE 1 4.5 Surface mount, Low power consumption Tube UD2-5NE 1 5.0 Surface mount, Low power consumption Tube UD2-3(1)NU-L 3.0 Surface mount Tape on Reel UD2-4.5(1)NU-L 4.5 Surface mount Tape on Reel UD2-5(1)NU-L 5.0 Surface mount Tape on Reel UD2-12(1)NU-L 12.0 Surface mount Tape on Reel UD2-3NE-L 1 3.0 Surface mount, Low power consumption Tape on Reel UD2-4.5NE-L 1 4.5 Surface mount, Low power consumption Tape on Reel UD2-5NE-L 1 5.0 Surface mount, Low power consumption Tape on Reel UD2-3(1)NUN 3.0 Surface mount, Minimum footprint Tube UD2-4.5(1)NUN 4.5 Surface mount, Minimum footprint Tube UD2-5(1)NUN 5.0 Surface mount, Minimum footprint Tube UD2-12(1)NUN 12.0 Surface mount, Minimum footprint Tube UD2-3NEN 1 3.0 Surface mount, Low power consumption, Minimum Footprint Tube UD2-4.5NEN 1 4.5 Surface mount, Low power consumption, Minimum Footprint Tube UD2-5NEN 1 5.0 Surface mount, Low power consumption, Minimum Footprint Tube UD2-3(1)NUN-L 3.0 Surface mount, Minimum footprint Tape on Reel UD2-4.5(1)NUN-L 4.5 Surface mount, Minimum footprint Tape on Reel UD2-5(1)NUN-L 5.0 Surface mount, Minimum footprint Tape on Reel UD2-12(1)NUN-L 12.0 Surface mount, Minimum footprint Tape on Reel UD2-3NEN-L 1 3.0 Surface mount, Low power consumption, Minimum Footprint Tape on Reel UD2-4.5NEN-L 1 4.5 Surface mount, Low power consumption, Minimum Footprint Tape on Reel UD2-5NEN-L 1 5.0 Surface mount, Low power consumption, Minimum Footprint Tape on Reel Part Number Nominal Coil Voltage Lead Type Packaging (1) To complete KEMET part number, leave blank for Non-latch or insert S for Single coil. Designates latch type. 1 Only available as Non-latch.
5© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Land Pattern – Millimeters UC2 Series (bottom view) V 0.8 X 7.6 8 - ø 0.85 1.51.5 3.2 2.2 2.2 7.6 V UD2 Series (top view) V 0.8 X 7.6 8 - ø 0.85 1.51.5 3.2 2.2 2.2 7.6 V Series V X UC2 (NU, NE, NJ) 5.08 — UD2 (NU, NE) 6.74 1.86 UD2 (NUN, NEN) 5.94 2.66
6© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Soldering Process UC2 – Through-hole Mounting Automatic Soldering Preheating: 110–120°C/110 seconds (maximum) Solder temperature: 260°C maximum Solder time: 5 seconds maximum Note: KEMET recommends cooling down a printed circuit board to less than 110°C within 40 seconds after soldering. Manual Soldering Solder temperature: 350°C maximum Solder time: 3 seconds maximum UD2 – Surface Mounting Note: Temperature profile shows printed circuit board surface temperature on the relay terminal portion. Please consult KEMET if you wish to use a temperature profile other than above. IRS Method 200 180 190 (Maximum 300) 45 (Maximum 70) 70 (Maximum 120) 220 200 180 Temperature (˚C) 220 Maximum 240˚C Time (seconds)
7© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Contact Specifications *1 This value is a reference value in the resistance load. Minimum capacity changes depending on the switching frequency, environment temperature, and load. *2 Rise time: 10 µs; decay time to half crest: 160 µs. *3 Rise time: 2 µs; decay time to half crest: 10 µs. *4 This shows the number of operations with fatal defects. Stable characteristics are maintained for 1 x 10 7 operations. Coil Specifications Non-latch Type (at 20°C) Nominal Coil Voltage (VDC) Coil Resistance (Ω) ±10% Operating Voltage1 (VDC) Release Voltage1 (VDC) Nominal Operating Power (mW) 3.0 64.3 2.25 0.30 140 4.5 145.0 3.38 0.45 140 5.0 178.0 3.75 0.50 140 9.0 579.0 6.75 0.90 140 12.0 1028.0 9.00 1.20 140 1 Test by pulse voltage. Item UC2/UD2 Contact Form 2 Form C Contact Material Silver alloy with gold alloy overlay Contact Ratings Maximum Switching Power 30 W, 37.5 VA Maximum Switching Voltage 220 VDC, 250 VAC Maximum Switching Current 1 A Maximum Carrying Current 1 A Minimum Contact Ratings 10 mVDC, 10 µA*1 Initial Contact Resistance 100 mΩ maximum (initial) Operating Time (excluding bounce) Approximately 2 milliseconds Release Time (excluding bounce) Approximately 1 milliseconds Insulation Resistance 1,000 MΩ at 500 VDC Withstand Voltage Between Open Contacts 1,000 VAC (for one minute), 1,500 V surge (10 x 160 µs) *2 Between Adjacent Contacts 1,000 VAC (for one minute), 1,500 V surge (10 x 160 µs) *2 Between Coil and Contacts 1,500 VAC (for one minute), 2,500 V surge (2 x 10 µs) *3 Shock Resistance 735 m/s2 (75 G) – misoperation 980 m/s2 (100 G) – destructive failure Vibration Resistance 10 to 55 Hz, double amplitude 3 mm (20 G) – misoperation 10 to 55 Hz, double amplitude 5 mm (30 G) – destructive failure Ambient Temperature −40 to +85°C −40 to +70°C (Low power consumption type) Coil Temperature Rise 18°C at nominal coil voltage (140 mW) Running Specifications Non-load 5 x 107 operations (Non-latch type) *4 1 x 107 operations (Latch type) Load 30 VDC 1 A (resistive), 1 x 10 5 operations at 20°C, 1 Hz 125 VAC 0.3 A (resistive), 1 x 105 operations at 20°C, 1 Hz Weight Approximately 0.8 g
8© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Coil Specifications cont. Single Coil Latch Type (at 20°C)2 Nominal Coil Voltage (VDC) Coil Resistance (Ω) ±10% Set Voltage1 (VDC) Reset Voltage1 (VDC) Nominal Operating Power (mW) 3.0 90.0 2.25 2.25 100 4.5 202.5 3.38 3.38 100 5.0 250.0 3.75 3.75 100 9.0 810.0 6.75 6.75 100 12.0 1440.0 9.00 9.00 100 1 Test by pulse voltage. 2 Latch type relays should be initialized to a known position before using. Only the specified polarity should be used to energize the coil. Non-latch, Low Power Consumption (NE, NEN) Type (at 20°C) Nominal Coil Voltage (VDC) Coil Resistance (Ω) ±10% Operating Voltage1 (VDC) Release Voltage1 (VDC) Nominal Operating Power (mW) 3.0 90.0 2.40 0.30 100 4.5 202.5 3.60 0.45 100 5.0 250.0 4.00 0.50 100 1 Test by pulse voltage. Recommended Relay Drive Conditions Coil Type Rating Ambient Temperature Non-latch Voltage: ≤ ±5% of nominal voltage −40 to +85°C Non-latch (Low power consumption type) −40 to +70°C Single Coil Square pulse (rise and fall time is rapid) Pulse height: ≤ ±5% of nominal voltage Pulse Width: > 10 ms −40 to +85°C Marking Top view Part Number Manufacturer Country of Origin Date Code Direction Mark (Pin No. 1 and 8)
9© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Maximum Coil Voltage Maximum value of permissible alteration Performance Data Coil Temperature Rise Temperature is measured by coil resistance Switching Capacity Maximum Values Applied Voltage vs. Timing (Sample: UC2–5NU)
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
2007.08.03 P0894EMDD03VOL03E
Applied power (mW) 0 5 10 15 20 Applied time (minute) -40 -20 0 20 40 60 80 100 200 150 100 Ambient temperature (°C) 10 20 50 100 2.0 1.0 0.5 0.2 0.1 Contact voltage (V) 0 100 150 200 2500 Applied power (mW) 0 100 200 300 4000 Applied power (mW) COIL TEMPERATURE RISE Temperature is measured b y coil resistance SWITCHING CAPACITY This is allowed maximum value. Inquire with NEC TOKIN for maximum value under continuous MAXIMUM COIL VOLTAGE This is a maximum value of permissible alteration. Inquire with NEC TOKIN under continuous use. APPLIED VOLTAGE VS. TIMING (Sample:UC2-5NU) (Without coil diode) DC(Resistive) AC(Resistive) 250VAC 220VDC Applied power 0.1W Applied power 0.14W Coil temperature rise (°C ) Coil temperature rise (°C) Contact current (A) Ratio o f nominal coil voltage (%) Operate time (ms) Release time (ms) Low power consumption type
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
Applied power (mW) 0 5 10 15 20 Applied time (minute) -40 -20 0 20 40 60 80 100 200 150 100 Ambient temperature (°C) 10 20 50 100 2.0 1.0 0.5 0.2 0.1 Contact voltage (V) 0 100 150 200 2500 Applied power (mW) 0 100 200 300 4000 Applied power (mW) COIL TEMPERATURE RISE Temperature is measured b y coil resistance SWITCHING CAPACITY This is allowed maximum value. Inquire with NEC TOKIN for maximum value under continuous MAXIMUM COIL VOLTAGE This is a maximum value of permissible alteration. Inquire with NEC TOKIN under continuous use. APPLIED VOLTAGE VS. TIMING (Sample:UC2-5NU) (Without coil diode) DC(Resistive) AC(Resistive) 250VAC 220VDC Applied power 0.1W Applied power 0.14W Coil temperature rise (°C ) Coil temperature rise (°C) Contact current (A) Ratio o f nominal coil voltage (%) Operate time (ms) Release time (ms) Low power consumption type
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
Applied power (mW) 0 5 10 15 20 Applied time (minute) -40 -20 0 20 40 60 80 100 200 150 100 Ambient temperature (°C) 10 20 50 100 2.0 1.0 0.5 0.2 0.1 Contact voltage (V) 0 100 150 200 2500 Applied power (mW) 0 100 200 300 4000 Applied power (mW) COIL TEMPERATURE RISE Temperature is measured b y coil resistance SWITCHING CAPACITY This is allowed maximum value. Inquire with NEC TOKIN for maximum value under continuous MAXIMUM COIL VOLTAGE This is a maximum value of permissible alteration. Inquire with NEC TOKIN under continuous use. APPLIED VOLTAGE VS. TIMING (Sample:UC2-5NU) (Without coil diode) DC(Resistive) AC(Resistive) 250VAC 220VDC Applied power 0.1W Applied power 0.14W Coil temperature rise (°C ) Coil temperature rise (°C) Contact current (A) Ratio o f nominal coil voltage (%) Operate time (ms) Release time (ms) Low power consumption type
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
Applied power (mW) 0 5 10 15 20 Applied time (minute) -40 -20 0 20 40 60 80 100 200 150 100 Ambient temperature (°C) 10 20 50 100 2.0 1.0 0.5 0.2 0.1 Contact voltage (V) 0 100 150 200 2500 Applied power (mW) 0 100 200 300 4000 Applied power (mW) COIL TEMPERATURE RISE Temperature is measured b y coil resistance SWITCHING CAPACITY This is allowed maximum value. Inquire with NEC TOKIN for maximum value under continuous MAXIMUM COIL VOLTAGE This is a maximum value of permissible alteration. Inquire with NEC TOKIN under continuous use. APPLIED VOLTAGE VS. TIMING (Sample:UC2-5NU) (Without coil diode) DC(Resistive) AC(Resistive) 250VAC 220VDC Applied power 0.1W Applied power 0.14W Coil temperature rise (°C ) Coil temperature rise (°C) Contact current (A) Ratio o f nominal coil voltage (%) Operate time (ms) Release time (ms) Low power consumption type
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
Applied power (mW) 0 5 10 15 20 Applied time (minute) -40 -20 0 20 40 60 80 100 200 150 100 Ambient temperature (°C) 10 20 50 100 2.0 1.0 0.5 0.2 0.1 Contact voltage (V) 0 100 150 200 2500 Applied power (mW) 0 100 200 300 4000 Applied power (mW) COIL TEMPERATURE RISE Temperature is measured b y coil resistance SWITCHING CAPACITY This is allowed maximum value. Inquire with NEC TOKIN for maximum value under continuous MAXIMUM COIL VOLTAGE This is a maximum value of permissible alteration. Inquire with NEC TOKIN under continuous use. APPLIED VOLTAGE VS. TIMING (Sample:UC2-5NU) (Without coil diode) DC(Resistive) AC(Resistive) 250VAC 220VDC Applied power 0.1W Applied power 0.14W Coil temperature rise (°C ) Coil temperature rise (°C) Contact current (A) Ratio o f nominal coil voltage (%) Operate time (ms) Release time (ms) Low power consumption type
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
Applied power (mW) 0 5 10 15 20 Applied time (minute) -40 -20 0 20 40 60 80 100 200 150 100 Ambient temperature (°C) 10 20 50 100 2.0 1.0 0.5 0.2 0.1 Contact voltage (V) 0 100 150 200 2500 Applied power (mW) 0 100 200 300 4000 Applied power (mW) COIL TEMPERATURE RISE Temperature is measured b y coil resistance SWITCHING CAPACITY This is allowed maximum value. Inquire with NEC TOKIN for maximum value under continuous MAXIMUM COIL VOLTAGE This is a maximum value of permissible alteration. Inquire with NEC TOKIN under continuous use. APPLIED VOLTAGE VS. TIMING (Sample:UC2-5NU) (Without coil diode) DC(Resistive) AC(Resistive) 250VAC 220VDC Applied power 0.1W Applied power 0.14W Coil temperature rise (°C ) Coil temperature rise (°C) Contact current (A) Ratio o f nominal coil voltage (%) Operate time (ms) Release time (ms) Low power consumption type
10© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Performance Data cont. Operate and Release Voltage vs. Ambient Temperature This shows a typical change of operate (release) voltage. The value of must operate is estimated, so coil voltage must be applied higher than this value for safe operation. For hot start operation, please inquire with KEMET. Running Test (Non-load) (Load: none; Drive: 5 VDC, 50 Hz, 50% duty; Ambient Temperature: room temperature; Sample: UC2–5NU, 20 pieces) Running Test (Load) (Load: 50 VDC, 0.1 A resistive; Drive: 5 VDC, 5 Hz, 50% duty; Ambient Temperature: 85°C; Sample: UC2–5NU, 10 pieces)
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
-40 -20 0 20 40 60 80 100 100 Ambient temperature (°C) OPERATE AND RELEASE VOLTAGE VS.AMBIENT TEMPERATURE This shows a typical change of operate (release) voltage. The value of must operate is estimated, so coil voltage must be applied more than this value for safety operation. Fo r hot start operation, please inquire with NEC TOKIN. Must operate voltage Operate voltage (typical) Release voltage (typical) Ratio of nominal coil voltage (%) Operations (×10 RUNNING TEST (Non-load) (Load: none, Drive:5VDC,50Hz,50%duty, Ambient temperature :room temperature, Sample:UC2-5NU ,20pieces) 0 20 50 100 500 1000 10000 1000 100 Contact resistance (mΩ) Operations (×10 0 20 50 100 500 1000 Operate voltage Release voltage Operate voltage (V) Release voltage (V) RUNNING TEST(Load) (Load: 50VDC 0.1A resistive,Drive:5VDC,5Hz,50%duty,Ambient temperature:85 °C, Sample:UC2-5NU ,10pieces) Contact resistance (mΩ) 0 2 5 10 50 100 Operations (×10 0 2 5 10 50 100 Operate voltage (V) Release Operations (×10 Operate voltage Release voltage
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
-40 -20 0 20 40 60 80 100 100 Ambient temperature (°C) OPERATE AND RELEASE VOLTAGE VS.AMBIENT TEMPERATURE This shows a typical change of operate (release) voltage. The value of must operate is estimated, so coil voltage must be applied more than this value for safety operation. Fo r hot start operation, please inquire with NEC TOKIN. Must operate voltage Operate voltage (typical) Release voltage (typical) Ratio of nominal coil voltage (%) Operations (×10 RUNNING TEST (Non-load) (Load: none, Drive:5VDC,50Hz,50%duty, Ambient temperature :room temperature, Sample:UC2-5NU ,20pieces) 0 20 50 100 500 1000 10000 1000 100 Contact resistance (mΩ) Operations (×10 0 20 50 100 500 1000 Operate voltage Release voltage Operate voltage (V) Release voltage (V) RUNNING TEST(Load) (Load: 50VDC 0.1A resistive,Drive:5VDC,5Hz,50%duty,Ambient temperature:85 °C, Sample:UC2-5NU ,10pieces) Contact resistance (mΩ) 0 2 5 10 50 100 Operations (×10 0 2 5 10 50 100 Operate voltage (V) Release Operations (×10 Operate voltage Release voltage
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
-40 -20 0 20 40 60 80 100 100 Ambient temperature (°C) OPERATE AND RELEASE VOLTAGE VS.AMBIENT TEMPERATURE This shows a typical change of operate (release) voltage. The value of must operate is estimated, so coil voltage must be applied more than this value for safety operation. Fo r hot start operation, please inquire with NEC TOKIN. Must operate voltage Operate voltage (typical) Release voltage (typical) Ratio of nominal coil voltage (%) Operations (×10 RUNNING TEST (Non-load) (Load: none, Drive:5VDC,50Hz,50%duty, Ambient temperature :room temperature, Sample:UC2-5NU ,20pieces) 0 20 50 100 500 1000 10000 1000 100 Contact resistance (mΩ) Operations (×10 0 20 50 100 500 1000 Operate voltage Release voltage Operate voltage (V) Release voltage (V) RUNNING TEST(Load) (Load: 50VDC 0.1A resistive,Drive:5VDC,5Hz,50%duty,Ambient temperature:85 °C, Sample:UC2-5NU ,10pieces) Contact resistance (mΩ) 0 2 5 10 50 100 Operations (×10 0 2 5 10 50 100 Operate voltage (V) Release Operations (×10 Operate voltage Release voltage
11© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Performance Data cont. Breakdown Voltage (Sample: UC2–5NU, 10 pieces) Alteration of Voltage in Dense Mounting (magnetic interference)
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
0 0.5 1.0 1.5 2.0 Breakdown voltage (K V) 100 0 1.0 1.5 2.0 2.5 100 0 1.5 2.0 2.5 2.5over BREAKDOWN VOLTAGE Sample: UC2-5NU 10peices (a) Between open contacts (b) Between adjacent contacts (C) Between coil and ALTERNATION OF VOLTAGE IN DENSE MOUNTING (Magnetic interference) Distribution Distribution (%) Distribution (%) Breakdown voltage (K V) Breakdown voltage (K V) ON ON OFF OFF ON ON OFF OFF ON ON ON OFF OFF OFF e f Device under test a b c d a b c d e f +40 +30 +20 +10 -10 -20 -30 -40 Mounting layout Alternation of operate voltage Ratio of alternation (%) +40 +30 +20 +10 -10 -20 -30 -40 Mounting layout a b c d e f Ratio of alternation (%) Alternation of operate voltage 2.5mm 3mm
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
0 0.5 1.0 1.5 2.0 Breakdown voltage (K V) 100 0 1.0 1.5 2.0 2.5 100 0 1.5 2.0 2.5 2.5over BREAKDOWN VOLTAGE Sample: UC2-5NU 10peices (a) Between open contacts (b) Between adjacent contacts (C) Between coil and ALTERNATION OF VOLTAGE IN DENSE MOUNTING (Magnetic interference) Distribution Distribution (%) Distribution (%) Breakdown voltage (K V) Breakdown voltage (K V) ON ON OFF OFF ON ON OFF OFF ON ON ON OFF OFF OFF e f Device under test a b c d a b c d e f +40 +30 +20 +10 -10 -20 -30 -40 Mounting layout Alternation of operate voltage Ratio of alternation (%) +40 +30 +20 +10 -10 -20 -30 -40 Mounting layout a b c d e f Ratio of alternation (%) Alternation of operate voltage 2.5mm 3mm
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
0 0.5 1.0 1.5 2.0 Breakdown voltage (K V) 100 0 1.0 1.5 2.0 2.5 100 0 1.5 2.0 2.5 2.5over BREAKDOWN VOLTAGE Sample: UC2-5NU 10peices (a) Between open contacts (b) Between adjacent contacts (C) Between coil and ALTERNATION OF VOLTAGE IN DENSE MOUNTING (Magnetic interference) Distribution Distribution (%) Distribution (%) Breakdown voltage (K V) Breakdown voltage (K V) ON ON OFF OFF ON ON OFF OFF ON ON ON OFF OFF OFF e f Device under test a b c d a b c d e f +40 +30 +20 +10 -10 -20 -30 -40 Mounting layout Alternation of operate voltage Ratio of alternation (%) +40 +30 +20 +10 -10 -20 -30 -40 Mounting layout a b c d e f Ratio of alternation (%) Alternation of operate voltage 2.5mm 3mm
12© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 A PPEARANCE 1,200 pieces/Reel Reel diameter: 380mm T APE DIMENSIONS RELAY DIRECTION MARK AND TAPE CARRYING DIRECTION Reel Top cover tape Emboss Carrying tape 24.0 4Φ 1.5 Φ 2.2 11.5 2.0 1.75 12.1 0.4 max. 8.1 14.7 24.0 4Φ 1.5 Φ 2.2 11.5 2.0 1.75 B 0.4 A 11.4 Direction mark Sprocket hole Direction of unreeling Direction mark Sprocket hole Direction of unreeling A PPEARANCE 1,200 pieces/Reel Reel diameter: 380mm T APE DIMENSIONS RELAY DIRECTION MARK AND TAPE CARRYING DIRECTION Reel Top cover tape Emboss Carrying tape 24.0 4Φ 1.5 Φ 2.2 11.5 2.0 1.75 12.1 0.4 max. 8.1 14.7 24.0 4Φ 1.5 Φ 2.2 11.5 2.0 1.75 B 0.4 A 11.4 Direction mark Sprocket hole Direction of unreeling Direction mark Sprocket hole Direction of unreeling A PPEARANCE 1,200 pieces/Reel Reel diameter: 380mm T APE DIMENSIONS RELAY DIRECTION MARK AND TAPE CARRYING DIRECTION Reel Top cover tape Emboss Carrying tape 24.0 4Φ 1.5 Φ 2.2 11.5 2.0 1.75 12.1 0.4 max. 8.1 14.7 24.0 4Φ 1.5 Φ 2.2 11.5 2.0 1.75 B 0.4 A 11.4 Direction mark Sprocket hole Direction of unreeling Direction mark Sprocket hole Direction of unreeling Tube Packing – Millimeters 50 pieces/Tube (anti-static) 11.0 12.1 560 Direction of relay direction markRubber stopper (Yellow) Rubber stopper (Green) Tape & Reel Packaging Information (UD2 only) – Millimeters Appearance Tape Dimensions Relay Direction Mark and Tape Carrying Direction Series A B NU-L, NE-L Maximum 6.2 9.2 NUN-L, NEN-L Maximum 6.6 7.5
13© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Notes on Using Relays 1. Contact Load Make sure that the contact load is within the specified range; otherwise, the lifetime of the contacts will be shortened considerably. Note that the running performance shown is an example, and that it varies depending on parameters such as the type of load, switching frequency, driver circuit, and ambient temperature under the actual operating conditions. 2. Driving Relays
- If the internal connection diagram of a relay shows + and - symbols on the coil, apply the rated voltage to the relay in the specified direction. If a rippled DC current source is used, abnormalities such as heat at the coil may occur.
- The maximum voltage that can be applied to the coil of the relay varies depending on the ambient temperature. Generally, the higher the voltage applied to the coil, the shorter the operating time. Note, however, that high voltage also increases the bounce of the contacts and the contact opening and closing frequency, which may shorten the lifetime of the contacts.
- For consistent operation, the driving voltage should have rise and fall times of less than 1 ms.
- For a latching relay, apply a voltage to the coil according to the polarity specified in the internal connection diagram of the relay.
- If a current is applied to the coil over a long period of time, the coil temperature rises, promoting generation of organic gas inside the relay, which may result in faulty contacts. In this case, use of a latching relay is recommended.
- The operating time and release time indicate the time required for each contact to close after the voltage has been applied to or removed from the coil. However, because the relay has a mechanical structure, a bounce state exists at the end of the operating and release times. Furthermore, because additional time is required until the contact stabilizes after being in a high-resistance state, care must be taken when using the relay at high speeds. 3. Operating Environment
- Make sure that the relay mounted in the application set is used within the specified temperature range. Use of a relay at a temperature outside this range may adversely affect insulation or contact performance.
- If the relay is used for a long period of time in highly humid (RH 85% or higher) environment, moisture may be absorbed into the relay. This moisture may react with the NOx and SOx generated by glow discharges that occur when the contacts are opened or closed, producing nitric or sulfuric acid. If this happens, the acid produced may corrode the metallic parts of the relay, causing operational malfunction.
- If any material containing silicon (silicon rubber, silicon oil, and silicon based coating material) is used in the neighborhood of relay, there is some possibility that these materials will emit silicon gas that will penetrate the relay. In this case, the switching contact may generate silicon compounds on the surface of contacts. This silicon compound may result in contact failure. Avoid use of relay in such an environment.
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
2007.08.03 P0886EMDD03VOL01E
- Notes on contact load Make sure that the contact load is within the specified range; otherwise, the lifetime of the contacts will be shortened considerably. Note that the running performance shown is an example, and that it varies depending on parameters such as the type of load, switching frequency, driver circuit, and ambient temperature under the actual operating conditions. Evaluate the performance by using the actual circuit before using the relay. 2. Driving relays - If the internal connection diagram of a relay shows + and - symbols on the coil, apply the rated voltage to the relay in the specified direction. If a rippled DC current source is used, abnormalities such as beat at the coil may occur. - The maximum voltage that can be applied to the coil of the relay varies depending on the ambient temperature. Generally, the higher the voltage applied to the coil, the shorter the operating time. Note, however, that a high voltage also increases the bounce of the contacts and the contact opening and closing frequency, which may shorten the lifetime of the contacts. - If the driving voltage waveform of the relay coil rises and falls gradually, the inherent performance of the relay may not be fully realized. Make sure that the voltage waveform instantaneously rises and falls as a pulse. - For a latching relay, apply a voltage to the coil according to the polarity specified in the internal connection diagram of the relay. - If a current is applied to the coil over a long period of time, the coil temperature rises, promoting generation of organic gas inside the relay, which may result in faulty contacts. In this case, use of a latching relay is recommended. - The operating time and release time indicate the time required for each contact to cl ose after the voltage has been applied to or removed from the coil. However, because the relay has a mechanical structur e, a bounce state exists at the end of the operating and re lease times. Furthermore, because additional time is required until the contact stabilizes after being in a high-resistance state, care must be taken when using the relay at high speeds. 3. Operating environment - Make sure that the relay mount ed in the application set is used within the specified temperature range. Use of a relay at a temperature outside this range may adversely affect insulation or contact performance. - If the relay is used for a long period of time in highly humid (RH 85% or higher) environment, moisture may be absorbed into the relay. This moisture may react with the NOx and SOx generated by glow discharges that occur when the contacts are opened or closed, producing nitric or sulfuric acid. If this happens, the ac id produced may corrode the metallic parts of the relay, causing operational malfunction. - If any material containing s ilicon (silicon rubber, silicon oil, and silicon based coating material) is used in the neighborhood of relay, there is some possibility that these materials will emit silicon gas that will penetrate the relay. In this case, the switching contact may generate silicon compounds on the surface of contacts. This silicon compound may result in contact failure. Avoid use of relay in such an environment. - Because the operating temperature range varies depending on the humidity, use the relay in the temperature range illustrated in the figure below. Prevent the relay from being frozen and avoid the generation of condensation. - The relay maintains constant sealability under normal atmospheric pressure (810 to 1,200 hpa). Its sealability may be degraded or the relay may be deformed and malfunction if it is used under barometric conditions exceeding the specified range. - The same applies when the relay is stored or transported. Keep the upper-limit value of th e temperature to which the relay is exposed after it is removed from the carton box to within 50°C. - Permanent magnets are used in polarized relays. For this reason, when magnets, trans formers, or speakers are located nearby the relay characteristics may change and faulty operations may result. - If excessive vibration or shock is applied to the relay, it may malfunction and the contacts remain closed. Vibration or shock applied to the relay during operation may cause considerable damage to or wearing of the contacts. Note that operation of a snap switch mounted close to the relay or shock due to the operation of magnetic solenoid may also cause malfunctioning. Nominal coil voltage <1msec. <1msec. -60 -40 -20 0 20 40 60 80 100 Temperature (°C ) Humidity (%RH)
14© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Notes on Using Relays cont.
- Because the operating temperature range varies depending on the humidity, use the relay in the temperature range illustrated in the figure below. Prevent the relay from being frozen and avoid the generation of condensation.
- The relay maintains constant sealability under normal atmospheric pressure (810 to 1,200 hpa). Its sealability may be degraded or the relay may be deformed and malfunction if it is used under barometric conditions exceeding the specified range.
- The same applies when the relay is stored or transported. Keep the upper-limit value of the temperature to which the relay is exposed after it is removed from the carton box to within 50°C.
- Permanent magnets are used in polarized relays. For this reason, when magnets, transformers, or speakers are located nearby the relay characteristics may change and faulty operations may result.
- If excessive vibration or shock is applied to the relay, it may malfunction and the contacts remain closed. Vibration or shock applied to the relay during operation may cause considerable damage to or wearing of the contacts. Note that operation of a snap switch mounted close to the relay or shock due to the operation of magnetic solenoid may also cause malfunctioning. 4. Mounting
- When mounting a relay onto a PC board using an automatic chip mounter, if excessive force is applied to the cover of the relay when the relay is chucked or inserted, the cover may be damaged or the characteristics of the relay degraded. Keep the force applied to the relay to within 1 kg.
- Avoid bending the pins to temporarily secure the relay to the PC board. Bending the pins may degrade sealability or adversely affect the internal mechanism.
- Ventilation immediately after soldering is recommended. Avoid immersing the relay in cleaning solvent immediately after soldering due to the danger of thermal shock being applied to the relay.
- Use an alcohol-based or water-based cleaning solvent. Never use thinner and benzene because they may damage the relay housing.
- Do not use ultrasonic cleaning because the vibration energy generated by the ultrasonic waves may cause the contacts to remain closed.
- All specifications in this catalog and production status of products are subject to change without notice. Prior to the purchase, please contact NEC TOKIN for updated product data.
- Please request for a specification sheet for detailed product data prior to the purchase.
- Before using the product in this catalog, please read "Precautions" and other safety precautions listed in the printed version catalog.
- Notes on contact load Make sure that the contact load is within the specified range; otherwise, the lifetime of the contacts will be shortened considerably. Note that the running performance shown is an example, and that it varies depending on parameters such as the type of load, switching frequency, driver circuit, and ambient temperature under the actual operating conditions. Evaluate the performance by using the actual circuit before using the relay. 2. Driving relays - If the internal connection diagram of a relay shows + and - symbols on the coil, apply the rated voltage to the relay in the specified direction. If a rippled DC current source is used, abnormalities such as beat at the coil may occur. - The maximum voltage that can be applied to the coil of the relay varies depending on the ambient temperature. Generally, the higher the voltage applied to the coil, the shorter the operating time. Note, however, that a high voltage also increases the bounce of the contacts and the contact opening and closing frequency, which may shorten the lifetime of the contacts. - If the driving voltage waveform of the relay coil rises and falls gradually, the inherent performance of the relay may not be fully realized. Make sure that the voltage waveform instantaneously rises and falls as a pulse. - For a latching relay, apply a voltage to the coil according to the polarity specified in the internal connection diagram of the relay. - If a current is applied to the coil over a long period of time, the coil temperature rises, promoting generation of organic gas inside the relay, which may result in faulty contacts. In this case, use of a latching relay is recommended. - The operating time and release time indicate the time required for each contact to cl ose after the voltage has been applied to or removed from the coil. However, because the relay has a mechanical structur e, a bounce state exists at the end of the operating and re lease times. Furthermore, because additional time is required until the contact stabilizes after being in a high-resistance state, care must be taken when using the relay at high speeds. 3. Operating environment - Make sure that the relay mount ed in the application set is used within the specified temperature range. Use of a relay at a temperature outside this range may adversely affect insulation or contact performance. - If the relay is used for a long period of time in highly humid (RH 85% or higher) environment, moisture may be absorbed into the relay. This moisture may react with the NOx and SOx generated by glow discharges that occur when the contacts are opened or closed, producing nitric or sulfuric acid. If this happens, the ac id produced may corrode the metallic parts of the relay, causing operational malfunction. - If any material containing s ilicon (silicon rubber, silicon oil, and silicon based coating material) is used in the neighborhood of relay, there is some possibility that these materials will emit silicon gas that will penetrate the relay. In this case, the switching contact may generate silicon compounds on the surface of contacts. This silicon compound may result in contact failure. Avoid use of relay in such an environment. - Because the operating temperature range varies depending on the humidity, use the relay in the temperature range illustrated in the figure below. Prevent the relay from being frozen and avoid the generation of condensation. - The relay maintains constant sealability under normal atmospheric pressure (810 to 1,200 hpa). Its sealability may be degraded or the relay may be deformed and malfunction if it is used under barometric conditions exceeding the specified range. - The same applies when the relay is stored or transported. Keep the upper-limit value of th e temperature to which the relay is exposed after it is removed from the carton box to within 50°C. - Permanent magnets are used in polarized relays. For this reason, when magnets, trans formers, or speakers are located nearby the relay characteristics may change and faulty operations may result. - If excessive vibration or shock is applied to the relay, it may malfunction and the contacts remain closed. Vibration or shock applied to the relay during operation may cause considerable damage to or wearing of the contacts. Note that operation of a snap switch mounted close to the relay or shock due to the operation of magnetic solenoid may also cause malfunctioning. Nominal coil voltage <1msec. <1msec. -60 -40 -20 0 20 40 60 80 100 Temperature (°C ) Humidity (%RH)
15© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 Notes on Using Relays cont. 5. Handling and Storage
- Relays are packaged in magazine cases for shipment. If a space is created in the case after some relays have been removed, be sure to insert a stopper to secure the remaining relays in the case. If relays are not well secured, vibration during transportation may cause malfunctioning of the contacts.
- Exercise care in handling the relay so as to avoid dropping it or allowing it to fall. Do not use a relay that has been dropped. If a relay drops from a workbench to the floor, a shock of 9,800 m/s2 (1,000 G) or more is applied to the relay, possibly damaging its functions. Even if a light shock has been applied to the relay, thoroughly evaluate its operation before using it.
- Latching relays are factory-set to reset state for shipment. A latching relay may be set, however, by vibration or shock applied while being transported. Be sure to forcibly reset the relay before using it in the application set. Also note that the relay may be set by unexpected vibration or shock when it is used in a portable set.
- The sealability of a surface mount (SMT) relay may be lost if the relay absorbs and is then heated during soldering. When storing relays, therefore, observe the following points: 1. For standard packing, please use relays within 12 months after delivery (storage conditions: 30°C/60% RH). If the relays have moisture absorption, dehumidify as follows: – Tape Packaging: 50 ±5°C, 200–300 hours. – Simple Relay: 85 ±5°C, 48 hours. 2. For MBB packing, please use relays within 2 years after delivery (storage conditions: 30°C/60% RH). After opening MBB packing, please use within 3 months (storage conditions: 30°C/60% RH).
16© KEMET Electronics Corporation • KEMET Tower • One East Broward Boulevard R7005_UC2_UD2 • 2/2/2023 Fort Lauderdale, FL 33301 USA • 954-766-2800 • www.kemet.com Miniature Signal Relays – UC2/UD2 KEMET Electronics Corporation Sales Offi ces For a complete list of our global sales offi ces, please visit www.kemet.com/sales. Disclaimer All product specifi cations, statements, information and data (collectively, the “Information”) in this datasheet are subject to change. The customer is responsible for checking and verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed. All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are not intended to constitute – and KEMET specifi cally disclaims – any warranty concerning suitability for a specifi c customer application or use. The Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained. Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage. Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicated or that other measures may not be required. KEMET requires its products to be packaged and shipped on pallets. This is because KEMET’s products are specifi cally designed to be packed onto pallets during shipment. If for any reason, the products are removed from pallets by the shipping party and shipped to the end customer, then additional external protection is required. In this instance, an external box with two carton layers and an upwards orientation sticker must be used by the shipping party, with the empty space fi lled with fi lling material, and afterwards sealing the box. If this packing and packaging guideline is not followed by the shipping party, the shipping party, and not KEMET, will be held responsible for any packaging, packing and/or product damages upon delivery of the products to the end customer. KEMET hereby disclaims any liability for damages to the products or otherwise that have been, or threaten to be, infl icted, result from or are in any way related to the packaging, packing or damage by the shipping party in contravention of the packing and packaging guidelines herein. KEMET is a registered trademark of KEMET Electronics Corporation.