Technical content
[ Obsolete product ] Agilent has a new name Keysight Technologies. Keysight Technologies Inc. is the world's leading electronic measurement company, transforming today's measurement experience through innovations in wireless, modular, and software solutions. With its HP and Agilent legacy, Keysight delivers solutions in wireless communications, aerospace and defense and semiconductor markets with world-class platforms, software and consistent measurement science. Alldatasheet.com
[1] U1253A/U1253B model [2] U1252A/U1252B/U1253A/U1253B models Figure 1: Automate recording of measurements with bundled GUI data-logging software. Do more with just one instrument The basic model, U1251A/U1251B, expands your capabilities beyond typical DMM measurements to include data logging. The U1252A/U1252B starts with the same foundation, and then adds a 20- MHz frequency counter and programmable square-wave generator — so you’d be able to perform more tests conveniently with one tool. What’s more: both models come bundled with a complete set of accessories to equip you right from the start at no extra cost. Offering the same functionality as the U1252A/U1252B, the U1253A/U1253B is the world’s first OLED handheld DMM. You won’t have to squint to be sure you’re reading it right: On the go or on the bench, you’ll get crystal-clear viewing indoors, even in dark, off-angle situations. Find problems quickly Troubleshooting can be tricky, especially when you’re dealing with elusive problems. With the U1250 Series’data logging capability, you can ensure that every reading gets recorded manually or at intervals you specify. Better yet: you can have virtually unlimited data logging saves when you connect any of the U1250 Series DMM to a PC with the optional IR-to-USB cable. In addition, the U1250 Series lets you achieve greater confidence in your measurements with accurate true-RMS AC measurements, low DCV error rate of up to 0.025% and high-resolution display of 50,000 counts. Uncompromising ruggedness and safety The U1250 Series DMMs are housed in robust overmold enclosures, rated at CAT III
1000 V and CAT IV 600 V and operate over a
wide temperature range of –20 °C to +55 °C. Each DMM also include a 30 kA high energy fuse to further protect you against violent fuse failures during high-current measure- ments. Built tough and certified to stringent industrial standards, the U1250 DMM is what you need to face the demands of everyday tasks. Superior contrast from organic LED (OLED) display 50,000-count dual display Up to 0.025% basic DCV accuracy True-RMS AC and AC+DC measurements K-type and J-type 2 temperature measurements Manual and automated (interval) data logging; internally to DMM and externally to PC CAT III 1000 V and CAT IV 600 V safety protection Built-in 20-MHz frequency counter Built-in programmable square-wave generator2 Key features Agilent U1250 Series Handheld Digital Multimeters Test more – more safely Data Sheet The Agilent U1250 Series handheld digital multimeters (DMMs) exceed your expectations by delivering powerful features and performance that meet your toughest requirements and applications. The series’ latest multimeters, the U1251B, U1252B and U1253B come in vivid orange cases, offering capabilities and functions equivalent to the U1250A Series.
[1] U1253A/U1253B only [2] U1252A/U1252B/U1253A/U1253B only OLED display with approximately 160° viewing angle, and high contrast ratio of 2000:1 for crystal-clear viewing 1 50,000 count dual display with true- RMS reading capability
20 MHz frequency
generator for stimulation of digital circuits CAT III 1000 V and CAT IV 600 V overvoltage protection for assurance of your safety while you go about your tasks Built-in battery charging for optimum capacity Broad range of measurement functions, including temperature and capacitance SHIFT key and one-stop function keys for easy access Take a closer look Figure 2: U1253B front view
FUNCTION RANGE RESOLUTION TEST CURRENT/ BURDEN VOLTAGE ACCURACY ± (% of reading + No. of Least Significant Digit) U1251A/U1251B U1252A/52B/53A/53B VOLTAGE(1) 50.000 mV 0.001 mV - 0.05 + 50[2] 0.05 + 50[2] 500.00 mV 0.01 mV - 0.03 + 5 0.025 + 5 1000.0 mV 0.1 mV - 5.0000 V 0.0001 V - 50.000 V 0.001 V - 500.00 V 0.01 V - 0.03 + 5 1000.0 V 0.1 V - RESISTANCE(8) 5.0000 kW[3] 0.0001 kW 416 µA 500.00 kW 0.01 kW 4.12 µA 5.0000 MW 0.0001 MW 375 nA 0.2 + 5 0.15 +5 50.000 MW[4] 0.001 MW 187 nA 1 + 10 1 + 5 500.00 MW[4] 0.01 MW 187 nA N/A 3+10 < 200 MW / 8+10 > 200 MW 500.00 nS[5] 0.01 nS 187 nA 1 + 20 1 + 10 CURRENT 500.00 µA 0.01 µA 0.06 V (100 W) 5000.0 µA 0.1 µA 0.6 V (100 W) 50.000 mA 0.001 mA 0.09 V (1 W) 440.00 mA 0.01 mA 0.9 V (1 W) 5.0000 A 0.0001 A 0.2 V (0.01 W) 0.3 + 10 0.3 + 10 DIODE TEST(8) - 0.1 mV 1.04 mA 0.05 + 5 DC SPECIFICATIONS [1] Input impedance: Refer to T able A on page 8. [2] The accuracy could be 0.05% + 10 for U1251A and 0.05% + 5 for U1252A/3A. Always use the NULL function to zero out the thermal effect before measuring the signal. [3] The accuracy of 500 W and 5 kW is specified after NULL function, which is used to subtract the test lead resistance and the thermal effect. [4] For the range of 50 MW and 500 MW, the R.H. is specified for <60%. [5] The accuracy is specified for <50 nS and after NULL function with open test lead. [6] Always use the NULL function to zero out thermal effect with open test lead before measuring the signal. If the NULL function is not used, an additional 20 counts needs to be added to the DC current accuracy. Thermal effect could occur due to the following:
- Wrong operation to measure the high voltage of 50 V ~ 1000 V for resistance, diode, and mV measurements.
- After battery-charging has completed.
- After measuring a current greater than 440 mA, it is suggested that the meter be left to cool down for twice the measuring time used. [7] Current can be measured up to 10 A continuously. An additional 0.5% needs to be added to the specified accuracy if the signal measured is in the range of 10 A~20 A for 30 seconds maximum. After measuring a current of > 10 A, leave the meter to cool down for twice the measuring time used before application of low current measurement. [8] Maximum open voltage: <+ 4.2V. U1251A/U1251B AC SPECIFICATIONS FUNCTION RANGE RESOLUTION ACCURACY ± (% of reading + No. of Least Significant Digit) FREQUENCY
30 Hz ~ 45 Hz 45 Hz ~ 1 kHz 1 kHz ~ 10 kHz 10 kHz ~ 30 kHz
VOLTAGE[1] [2] 50.000 mV 0.001 mV 1.0+60 0.6+40 1.0+40 1.6+60 500.00 mV 0.01 mV 0.6+25 1000.0 mV 0.1 mV 1.0+25 1.6+405.0000 V 0.0001 V 50.000 V 0.001 V 500.00 V 0.01 V 1.6+40 [3] 1000.0 V 0.1 V 0.6+40 1.0+40 N/A
ACCURACY ± (% of reading + No. of Least Significant Digit) FREQUENCY
30 Hz ~ 45 Hz 45 Hz ~ 2 kHz 2 kHz ~ 20 kHz
AC CURRENT[2] 500.00 µA[4] 0.01 µA 1.5+50 0.8+20 3.0+80 5000.0 µA 0.1 µA 1.5+40 3.0+60 50.000 mA 0.001 mA 440.00 mA 0.01 mA 5.0000 A 0.0001 A 2.0+40[6] 3+60, <3 A/5 kHz 10.000 A[5] 0.001 A U1252A/U1252B/U1253A/U1253B AC SPECIFICATIONS FUNCTION RANGE RESOLUTION ACCURACY ± (% of reading + No. of Least Significant Digit) FREQUENCY
20 Hz ~ 45 Hz 45 Hz ~ 1 kHz 1 kHz ~ 10 kHz 10 kHz ~ 20 kHz 20 kHz~100 kHz [5]
VOLTAGE[1] [8] 50.000 mV 0.001 mV 1.5+60 0.4+40 0.7+40 3.5+120 500.00 mV 0.01 mV 0.4+25 1000.0 mV 0.1 mV 5.0000 V 0.0001 V 50.000 V 0.001 V 500.00 V 0.01 V 3.5+120 [3] FUNCTION RANGE RESOLUTION ACCURACY ± (% of reading + No. of Least Significant Digit) FREQUENCY
20 Hz ~ 45 Hz 45 Hz ~ 1 kHz 1 kHz ~ 20 kHz 20 kHz~100 kHz [7]
AC CURRENT[8] 500.00 µA[4] 0.01 µA 1.0+20 0.7+20 0.75+20 5.0+80 5000.0 µA 0.1 µA 50.000 mA 0.001 mA 440.00 mA 0.01 mA 1.5+20 5.0000 A 0.0001 A 1.5+20[6] 3+60, <3 A/5 kHz N/A 10.000 A[5] 0.001 A [1] Input impedance: Refer to T able A on page 8. [2] AC mV/V and AC µA/mA/A specifications are true RMS AC coupled, valid from 5% to 100% of range. The crest factor may be up to 3 at full scale, up to 5 at half- scale, except for 1000 mV and 1000 V ranges, where the crest factor is 1.5 at full scale and 3 at half scale. [3] The input signal is lower than 20,000,000 V-Hz (the product of voltage and frequency). [4] Input current >35 µArms. [5] Current can be measured from 2.5 A up to 10 A continuously. An additional 0.5% needs to be added to the specified accuracy if the signal measured is in the range of 10 A ~ 20 A for 30 seconds maximum. After measuring a current of >10 A, leave the meter to cool down for twice the measuring time used before application of low current measurement. [6] Input current < 3 Arms. [7] The additional error to be added as frequency >20 kHz and signal input <10% of range: 3 counts of LSD per kHz. add 0.1% of reading ± 0.3% of range. 0.4+25 0.4+25 0.6+25 0.75+40 1.5+40
ACCURACY ± (% of reading + No. of Least Significant Digit) FREQUENCY
30 Hz ~ 45 Hz 45 Hz ~ 1 kHz 1 kHz ~ 10 kHz 10 kHz ~ 20 kHz 20 kHz~100 kHz [3]
VOLTAGE[1] [2] 500.00 mV 0.01 mV 1.5+65 0.4+30 3.5+125 1000.0 mV 0.1 mV 5.0000 V 0.0001 V 50.000 V 0.001 V 500.00 V 0.01 V 3.5+125 [4] U1252A/U1252B/U1253A/U1253B AC+DC SPECIFICATIONS FUNCTION RANGE RESOLUTION ACCURACY ± (% of reading + No. of Least Significant Digit) FREQUENCY
30 Hz ~ 45 Hz 45 Hz ~ 1 kHz 1 kHz ~ 20 kHz
500.00 µA[5] 0.01 µA 5000.0 µA 0.1 µA 50.000 mA 0.001 mA 440.00 mA 0.01 mA 5.0000 A 0.0001 A 1.8+30[7] 0.9+30 3.3+70, <3 A/5 kHz10.000 A[6] 0.001 A 0.9+25 CAPACITANCE SPECIFICATIONS RANGE RESOLUTION ACCURACY MEASURING RATE AT FULL SCALE MAX. DISPLAY 10.000 nF 0.001 nF 1% + 8 4 times/sec. 11000 counts 100.00 nF 0.01 nF 1% + 5 1000.0 nF 0.1 nF 10.000 µF 0.001 µF 100.00 µF 0.01 µF 1000.0 µF 0.1 µF 1 time/sec. 10.000 mF 0.001 mF 0.1 times/sec. 100.00 mF 0.01 mF 3% + 10 0.01 times/sec 0.4+30 0.6+30 0.4+30 0.8+45 1.5+45 U1251A/U1251B/U1252A/U1252B TEMPERATURE SPECIFICATIONS U1253A/U1253B TEMPERATURE SPECIFICATIONS THERMOCOUPLE TYPE RANGE RESOLUTION ACCURACY ºC ºF ºC ºF K –200 ~ 1372 ºC –328 ~ 2502 ºF 0.1 ºC/0.1 ºF 0.3% + 3 ºC 0.3% + 6 ºF J (for U1252A) –210 ~ 1200 ºC –346 ~ 2192 ºF 0.1 ºC/0.1 ºF 0.3% + 3 ºC 0.3% + 6 ºF THERMOCOUPLE TYPE RANGE RESOLUTION ACCURACY ºC ºF ºC ºF K J
U1251A/U1251B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT FREQUENCY SENSITIVITY AND TRIGGER LEVEL INPUT RANGE MINIMUM SENSITIVITY (R.M.S. Sine Wave) TRIGGER LEVEL FOR DC COUPLING (Maximum input for specified accuracy = 10 x Range or 1000 V)
20 Hz - 100 kHz >100 kHz ~ 200 kHz < 100 kHz >100 kHz ~ 200 kHz
50.000 mV 10 mV 15 mV 10 mV 15 mV 500.00 mV 25 mV 35 mV 60 mV 70 mV 1000.0 mV 40 mV 50 mV 100 mV 150 mV 50.000 V 2.5 V 5 V 5 V 6 V
500.00 V 25 V N/A 50 V N/A
1000.0 V 50 V N/A 300 V N/A
U1252A/U1252B/U1253A/U1253B FREQUENCY SENSITIVITY DURING VOLTAGE MEASUREMENT FREQUENCY SENSITIVITY AND TRIGGER LEVEL INPUT RANGE MINIMUM SENSITIVITY (R.M.S. Sine Wave) TRIGGER LEVEL FOR DC COUPLING (Maximum input for specified accuracy = 10 x Range or 1000 V)
20 Hz ~ 200 kHz >200 kHz ~ 500 kHz < 100 kHz >100 kHz ~ 500 kHz
50.000 mV 10 mV 25 mV 10 mV 25 mV 500.00 mV 70 mV 150 mV 70 mV 150 mV 1000.0 mV 120 mV 300 mV 120 mV 300 mV
50.000 V 3 V 5 V 6 V 15 V
500.00 V 30 V < 100 kHz N/A 60 V N/A
1000.0 V 50 V < 100 kHz N/A 120 V N/A
RANGE RESOLUTION ACCURACY MIN. INPUT FREQUENCYU1251A/2A U1253A 1 Hz 999.99 Hz 0.01 Hz 9.9999 kHz 0.0001 kHz 99.999 kHz 0.001 kHz 999.99 kHz 0.01 kHz FREQUENCY SPECIFICATIONS[4] [1] Input impedance: Refer to T able A on page 8. For non-sinusoidal waveform, add 0.1% of reading ± 0.3% of range. [3] The additional error to be added as frequency >20 kHz and signal input <10% of range: 3 counts of LSD per kHz. [4] The input signal is lower than 20,000,000 V-Hz (the product of voltage and frequency). [5] Input current >35 µArms. [6] Current can be measured from 2.5 A up to 10 A continuously. An additional 0.5% needs to be added to the specified accuracy if the signal measured is in the range of 10 A ~ 20 A for 30 seconds maximum. After measuring a current of >10 A, leave the meter to cool down for twice the measuring time used before application of low current measurement. [7] Input current < 3 Arms. [8] For non-square wave signals, add 5 counts.
FREQUENCY SENSITIVITY DURING CURRENT MEASUREMENT INPUT RANGE MINIMUM SENSITIVITY (R.M.S. Sine Wave)
20 Hz ~ 20 kHz
500.00 µA 100 µA 5000.0 µA 250 µA 50.000 mA 10 mA 440.00 mA 25 mA
5.0000 A 1 A
10.000 A 2.5 A PEAK HOLD SIGNAL WIDTH ACCURACY FOR DC mV/VOLTAGE/CURRENT Single event > 1 ms 2% + 400 for all ranges Repetitive > 250 µs 2% + 1000 for all ranges DUTY CYCLE AND PULSE WIDTH [1] FUNCTION MODE RANGE ACCURACY AT FULL SCALE DUTY CYCLE DC Coupling 0.01% ~ 99.99% 0.3% per kHz + 0.3% PULSE WIDTH 500 ms 0.01 ms 0.2% + 3 2000 ms 0.1 ms 0.2% + 3 [1] The positive or negative pulse width must be greater than 10 µs, and the duty cycle range should be considered. The pulse width range is determined by the frequency of the signal. U1252A/U1252B/U1253A/U1253B SQUARE WAVE OUTPUT OUTPUT[2] RANGE RESOLUTION ACCURACY 40, 50, 60, 75, 80, 100, 120, 150, 200, 240, 300, 400, 480, 600, 800, 1200, 1600, 2400, 48000 Hz 0.01 Hz 0.005% + 2 DUTY CYCLE[3] 0.39% ~ 99.60% 0.390625% 0.4% of full scale[4] PULSE WIDTH[4] 1/Frequency Range/256 0.2 ms + Range/256 AMPLITUDE Fixed 0 ~ +2.8 V 0.1 V 0.2 V U1252A/U1252B/U1253A/U1253B FREQUENCY COUNTER SPECIFICATIONS DIVISION RANGE RESOLUTION ACCURACY ± (% of reading + No. of Least Significant Digit) SENSITIVITY MIN. INPUT FREQUENCY MAXIMUM MEASURE- MENT LEVELU1252A U1253A (secondary display “-1-“) 100 mV R.M.S. 0.5 Hz < 30 Vpp 999.99 Hz 0.01 Hz 0.002% + 5, <985 kHz 0.002% + 5, < 985 kHz 9.9999 kHz 0.0001 kHz 99.999 kHz 0.001 kHz 999.99 kHz 0.01 kHz 200 mV R.M.S. 9.9999 MHz 0.0001 MHz 0.002% + 5, < 1 MHz 100 (secondary display “-100-“) 9.9999 MHz 0.0001 MHz 0.002% + 5, < 20 MHz 0.002% + 5, < 20 MHz 400 mV R.M.S.
Capacitance 4 (< 100 µF) DCI 7 ACI 7 AC + DC I 2 Temperature 6 Frequency 1 (>10 Hz) Duty cycle/Pulse width 0.5 (>10 Hz) DECIBEL (dB) CALCULATION dB BASE REFERENCE DEFAULT REFERENCE 1 mW (dBm) 1-9999 W 50 W
1 V (dBV) 1 V 1 V
MANUAL AND INTERVAL DATA LOGGING LOGGING TYPE MAXIMUM DATA POINTS[5] U1251A U1252A U1253A MANUAL 100 100 100 INTERVAL 200 200 1000 [1] All frequency counters are susceptible to errors. Shielding inputs from external noise pickup is critical to minimize measurement errors. For non-square wave signals, add 5 counts. [2] Output impedance: 3.5 kW maximum. [3] The positive or negative pulse width must be greater than 50 µs for adjustment of the duty cycle or pulse width under different frequencies. Otherwise, the accuracy and range will be different from the specifications defined. [4] For signal frequencies greater than 1 kHz, an addition of 0.1% per kHz is added to the accuracy. [5] For data logging to PC, maximum number of data points is dependent on available hard disk space. [6] For the U1253A/U1253B model. [1] For 5 V to 1000 V range, the specified input impedance in parallel with 10 MW at dual display. [2] The specified input impedance (nominal) in parallel with <100 pF. Table A INPUT IMPEDANCE FUNCTION RANGE INPUT IMPEDANCE DC Voltage[1] 50.000 mV 10.00 MW 500.00 mV 10.00 MW 1000.0 mV 10.00 MW 5.0000 V 11.10 MW 50.000 V 10.10 MW 500.00 V 10.01 MW 1000.0 V 10.001 MW AC Voltage[2] 50.000 mV 10.00 MW 500.00 mV 10.00 MW 1000.0 mV 10.00 MW 5.0000 V 10.00 MW 50.000 V 10.00 MW 500.00 V 10.00 MW 1000.0 V 10.00 MW AC + DC Voltage[2] 50.000 mV 10.00 MW 500.00 mV 10.00 MW 1000.0 mV 10.00 MW 5.0000 V 11.10 MW || 10 MW 50.000 V 10.10 MW || 10 MW 500.00 V 10.01 MW || 10 MW 1000.0 V 10.001 MW || 10 MW
Both primary and secondary displays are 5-digit on the LCD display. Both the primary and secondary displays offer a maximum resolution of 50,000 counts. Automatic polarity indication. POWER CONSUMPTION 105 mVA / 420 mVA (with backlight) maximum (U1251A/U1251B) 165 mVA / 480 mVA (with backlight) maximum (U1252A/U1252B) 420 mVA maximum (U1253A/U1253B) BATTERY TYPE
9 V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61)
9 V Carbon-zinc battery (ANSI/NEDA 1604D or IEC6F22)
7.2 V or 8.4 V Ni-MH Rechargeable battery BATTERY LIFE U1251A/U1251B: 72 hours typical U1252A/U1252B: 36 hours typical U1253A/U1253B: 8 hours typical OPERATING ENVIRONMENT
- Full accuracy at –20 oC to 55 oC ; and to 80% RH for temperatures up to 35 °C, decreasing linearly to 50% RH at 55 °C
- 0 to 2000 m altitude per IEC 61010-1 2nd Edition CAT III, 1000 V / CAT IV, 600 V STORAGE COMPLIANCE –40 oC to 70 oC with battery removed SAFETY COMPLIANCE
- IEC 61010-1:2001 / EN610101-1:2001
- Canada: CSA C22.2 No. 61010-1:2004 MEASUREMENT CATEGORY CAT III 1000 V / CAT IV 600 V EMC COMPLIANCE Certified to IEC/EN 61326: 2002, CISPR 11, and equivalents for Group 1, Class A COMMON MODE REJECTION RATIO (CMRR) U1251A/U1251B/U1252A/U1252B: >90 dB at DC, 50/60 Hz ± 0.1% (1 kW unbalanced) U1253A/U1253B: >100 dB at DC, 50/60 Hz ± 0.1% (1 kW unbalanced) NORMAL MODE REJECTION RATIO (NMRR) U1251A/U1251B/U1252A/U1252B: >60 dB at DC, 50/60 Hz ± 0.1% U1253A/U1253B: >90 dB at DC, 50/60 Hz ± 0.1% TEMPERATURE COEFFICIENT 0.15 * (specified accuracy)/ oC (from 20 oC to 18 oC or 28 oC to 55 oC) SHOCK and VIBRATION Tested to IEC/EN 60068-2 DIMENSIONS (HxWxD) 203.5 mm x 94.4 mm x 59.0 mm WEIGHT U1251A/U1251B: 504±5 g with battery U1252A/U1252B/U1253A/U1253B: 527±5 g with battery CHARGING TIME (only U1252A/3A) < 220 minutes approx. at the environment of 10 oC to 30 oC WARRANTY 3 years for main unit 3 months for standard accessories unless otherwise specified. GENERAL SPECIFICATIONS
STANDARD SHIPPED ACCESSORIES
ORDERING INFORMATION
MEASURING ACCESSORIES (NON-TEMPERATURE) DESCRIPTION APPLICABLE MODELS U1251A U1252A U1253A U1251B U1252B U1253B Fine-tip test probes • • – – – – Test probe leads (4-mm) • • • • • • Test probe leads (19-mm) • • • • • • Alkaline 9 V battery • – – • – – Rechargeable Ni-MH battery with Soft carrying case • • – – – – Certificate of Calibration • • • • • • Option 001 Bundled SMT grabbers, fine-tip test probes and soft carrying case U1251A U1252A U1253AU1251B U1252B U1253B U1160A Standard test lead kit Includes two test leads (red and black), alligator clips, fine-tip test probes, SMT grabbers and mini grabber (black).
- T est leads: CAT III 1000 V, 15 A
- Alligator clips: CAT III 1000 V, 10 A
- Fine-tip test probes: CAT II 300 V, 3 A
- SMT grabbers: CAT II 300 V, 3 A
- Mini grabber: CAT II 300 V, 3 A U1161A Extended test lead kit Includes two test leads (red and black), two test probes, medium-sized alligator clips and 4-mm banana plugs.
- T est leads: CAT III 1000 V, CAT IV 600 V, 15 A
- T est probes: CAT III 1000 V, 15 A
- Medium-sized alligator clips: CAT III 600 V, 10 A
- 4-mm banana plugs: CAT II 600 V, 10 A U1162A Alligator clips
- One pair of insulated alligator clips (red and black). Recommended for use with Agilent standard test leads.
- Rated CAT III 1000 V, 10 A.
MEASURING ACCESSORIES (NON-TEMPERATURE) U1583B AC current clamp
- Dual range: 40 A and 400 A
- Rated CAT III 600 V
- BNC-to-banana-plug adapter provided for use with DMMs U1169A Test probe leads Includes two test leads (red and black), and a pair each of 19-mm and 4-mm test probes.
- Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
- Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
- Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A (highly recommended for CAT IV environment) U1168A Standard test lead kit Includes two test leads (red and black), 19-mm and 4-mm test probes, alligator clips, fine-tip test probes, SMT grabbers and mini grabber (black).
- Test leads: CAT III 1000 V, CAT IV 600 V, 15 A
- Test probes (19-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A
- Test probes (4-mm tip): CAT III 1000 V, CAT IV 600 V, 15 A (highly recommended for CAT IV environment)
- Alligator clips: CAT III 1000 V, 10 A
- Fine-tip test probes: CAT II 300 V, 3 A
- SMT grabber: CAT II 300 V, 3 A
- Mini grabber: CAT II 300 V, 3 A MEASURING ACCESSORIES (TEMPERATURE) U1180A Thermocouple adapter+lead kit, J and K types Includes thermocouple adapter, thermocouple bead J-type and thermocouple bead K-type.
- T/C adapter J/K-type
- T/C bead J-type: –20 °C to 200 °C
- T/C bead K-type: –20 °C to 200 °C U1181A Immersion temperature probe
- Type-K T/C for use in oil and other liquids
- Measurement range: –50 °C to 700 ºC
- Includes adapter U1184A for connection to DMM U1182A Industrial surface temperature probe
- Type-K T/C for use on still surfaces
- Measurement range: –50 ºC to 400 ºC
- Includes adapter U1184A for connection to DMM U1183A Air temperature probe
- Type-K T/C for use in air and non-caustic gas
- Measurement range: –50 ºC to 800 ºC
- Includes adapter U1184A for connection to DMM U1184A Temperature probe adapter
- Mini-connector-to-banana-plug adapter for use with DMM U1185A J-type thermocouple and adapter
- T/C adapter J/K-type
- T/C bead J-type: –20 °C to 200 °C U1163A SMT grabbers
- One pair of SMT grabbers (red and black). Recommended for use with Agilent standard test leads.
- Rated CAT II 300 V, 3 A. U1164A Fine-tip test probes
- One pair of fine-tip test probes (red and black). Recommended for use with Agilent standard test leads.
- Rated CAT II 300 V, 3 A. U1165A Test probe leads
- Rated CAT III 1000 V, 15 A
Includes AC power cord based on country U1173A IR-to-USB cable
- For remote control and data logging to PC
- Max. baud rate: 19,200 bits per second U1171A Magnetic hanging kit For fastening of DMM to a steel surface so both hands are free. MEASURING ACCESSORIES (TEMPERATURE) U1186A K-type thermocouple and adapter
- T/C adapter J/K-type
- T/C bead J-type: –20 °C to 200 °C U1172A Transit case (aluminium-clad) The robust casing to transport your DMM and accessories
- Aluminum-clad, black panel construction
- Dimension: 18” (H) x 13” (W) x 6“ (D)
- Weight: 4 kg U1174A Soft carrying case The convenient way to carry your DMM and essential accessories
- Dimension: 9” (H) x 5” (W) x 3” (D)
www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Agilent Channel Partners www.agilent.com/find/channelpartners Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience. Americas Canada (877) 894 4414 Latin America 305 269 7500 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 T aiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 43 (0) 1 360 277 1571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 €/minute Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: October 1, 2009 www.agilent.com www.agilent.com/find/handhelddmm For more information on Agilent T echnologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus © Agilent T echnologies, Inc. 2009 Printed in USA, November 25, 2009 5989-5509EN Product specifications and descriptions in this document subject to change without notice. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment through- out its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. For informa - tion regarding self maintenance of this product, please contact your Agilent office. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt