DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 9

Technical content

Features

Parameter Symbol Minimum Maximum Units Storage Temperature TST - 40 + 85 °C Operating Case Temperature 1 Commercial TOP - 5 + 70 °CExtended - 5 + 85 Industrial - 40 + 85 Supply Voltage VCC 3 - 0.2 + 3.6 V VCC 5 - 0.2 + 6.0 Operating Relative Humidity 2 RH 0 85 % Input Voltage VIN 0 V CC V 1 Case temperature is measured on top side of XFP module.

2 Non condensing

Multi-rate 10-Gigabit DWDM 80km XFP Transceiver with Digital Diagnostics

Oplink Communications, Inc 2 TXD3XGHL2xx S0321. Rev.04. (web) 2014-03-21 Oplink Communications, Inc. This product complies with 21 CFR 1040.10 and 1040.11 Meets Class 1 Laser Safety Requirements Laser Safety: All transceivers are Class 1 Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions. Transmitter Performance Characteristics (Over Operating Case Temperature Range) Parameter Symbol Minimum Typical Maximum Units Operating Data Rate 1 B 9.95 - 11.09 Gb/s Average Optical Output Power (50% duty cycle) PO 0 - + 4.0 dBm Transmitter OFF Power POFF - - - 45.0 dBm Extinction Ratio @ 9.95Gb/s to 10.7Gb/s ER 8.2 - - dB Center Wavelength 2 λC See Ordering Information Table nm Spectral Width (-20dB) Δλ20 - - 1.0 nm Side Mode Suppression Ratio SMSR 30 - - dB Relative Intensity Noise RIN - - - 130 dB/Hz Reflectance Tolerance refT - - - 27 dB Jitter Generation 3 20 kHz – 80 MHz JG20K - - 0.3 UIpp 4 MHz – 80 MHz JG4M - - 0.1 UIpp Optical Output Eye Compliant with GR253-CORE, IEEE 803.3ae , and ITU-T G.959 1 8.5Gb/s is supported through Data Rate Selection feature. 2 BOL: +/-0.05nm from ITU grid. EOL: +/-0.1nm from ITU grid. 3 Jitter generation is compliant with GR-253 and G.8251. Receiver Performance Characteristics Parameter Symbol Minimum Typical Maximum Units Operating Data Rate 1 B 9.95 - 11.09 Gb/s Wavelength of Operation λ 1260 - 1570 nm Receiver Sensitivity @ 9.95Gb/s (10-12 BER) Pmin_BB - - - 24.0 dBm Receiver Sensitivity with 80km fiber @ 9.95Gb/s (10-12 BER) Pmin_Fiber - - - 21.5 dBm Maximum Input Power (10-12 BER) PMAX - 7.0 - - dBm LOS Thresholds Increasing Light Input Plos+ - - - 27.0 dBm Decreasing Light Input Plos- - 38.0 - - LOS Hysteresis - 0.5 - - dB Receiver Reflectance - - - - 27 dB 1 8.5Gb/s is supported through Data Rate Selection feature. (Over Operating Case Temperature Range)

Oplink Communications, Inc 3 TXD3XGHL2xx S0321. Rev.04. (web) 2014-03-21 XFP Transceiver Electrical Pad Layout Host Board Connector Pad Layout Bottom of XFP Board (as viewed thru top of board) Top of XFP Board GND RX_LOS Mod_NR Mod_Abs SDA SCL VCC3 VCC3 GND VCC5 TX_Dis Interrupt Mod_DeSel VEE5 GND GND TD+ TD- GND GND RefCLK- RefCLK+ GND VCC2 TP_Down/RS VCC2 GND RD+ RD- GND GND Interrupt Vcc3 SDA Mod_Abs GND GND TX_Dis RX_LOS Mod_NR SCL Vcc3 Vcc5 Mod_DeSel V EE5 GND Vcc2 GND RefCLK+ GND P_Down/RST RD- GND TD- GND RefCLK- TD+ RD+ Vcc2 GND Toward Bezel Toward ASIC Electrical Power Supply Characteristics (Over Operating Case Temperature Range) Parameter Symbol Minimum Typical Maximum Units Supply Voltage VCC3 3.13 3.3 3.47 V VCC5 4.75 5.0 5.25 Supply Current ICC3 - - 750 mA ICC5 - - 500 Power Dissipation PW - - 3.5 W P_Down Power Dissipation PDW - - 1.5 W Electrical Interface (Over Operating Case Temperature Range) Parameter Symbol Minimum Typical Maximum Units Differential Impedance Zd - 100 - Ω Differential Input Voltage Swing Vpp, diff_in 120 - 820 mV Differential Output Voltage Swing Vpp, diff_out 340 550 850 mV Output Rise/Fall Time (20 to 80%) Tr /Tf 24 - - ps TX_Dis, P_Down/RST VIL - 0.3 - 0.8 V VIH 2.0 - VCC + 0.3 XFP Interrupt, Mod_NR, RX_LOS VOL 0 - 0.4 V VOH host_VCC - 0.5 - host_VCC + 0.3

Oplink Communications, Inc 4 TXD3XGHL2xx S0321. Rev.04. (web) 2014-03-21 Module Pin Description Pin Logic Symbol Description 1 - GND Module Ground 2 - VEE5 Optional -5.2V Power Supply (Not Required)

3 LVTTL-I Mod_DeSel Module De-select; When held low allows module to respond to 2-wire serial interface

4 LVTTL-O Interrupt Interrupt; Indicates presence of an important condition which can be read over the 2-wire serial Interface

5 LVTTL-I TX_Dis Transmitter Disable; Turns off transmitter laser output

8 - VCC3 +3.3V Power Supply 9 - VCC3 +3.3V Power Supply

10 LVTTL-I/O SCL 2-Wire Serial Interface Clock

11 LVTTL-I/O SDA 2-Wire Serial Interface Data Line

12 LVTTL-O Mod_Abs Indicates Module is not present. Grounded in the Module

13 LVTTL-O Mod_NR Module Not Ready; Indicating Module Operational Fault

14 LVTTL-O RX_LOS Receiver Loss Of Signal Indicator

17 CML-O RD- Receiver Inverted Data Output

18 CML-O RD+ Receiver Non-Inverted Data Output

21 LVTTL-I P_Down/RST

Power down; When high, requires the module to limit power consumption to 1.5W or below. 2-Wire serial interface must be functional in the low power mode. Reset; The falling edge initiates a complete reset of the module including the 2-wire serial interface, equivalent to a power cycle. 22 - VCC2 Not Used 23 - GND Module Ground

24 PECL-I RefCLK+ Reference Clock Non-Inverted Input (Not Required)

25 PECL-I RefCLK- Reference Clock Inverted Input (Not Required)

28 CML-I TD- Transmitter Inverted Data Input

29 CML-I TD+ Transmitter Non-Inverted Data Input

1 8.5Gb/s 0 9.95Gb/s to 11.09Gb/s Factory default setting = 0; can be customized upon request. byte 60 bit 0.

Oplink Communications, Inc 5 TXD3XGHL2xx S0321. Rev.04. (web) 2014-03-21 Application Notes Electrical Interface: All signal interfaces are compliant with the XFP MSA specification. The high speed DATA interface is differential AC-coupled internally and can be directly connected to a 3.3V SERDES IC. RX_LOS: The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic HIGH when an insufficient photocurrent is produced. TX_Dis: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled. (less than -45dBm). P_Down: The Power Down Function pin, when held High by the host, places the module in the standby (Low Power) mode with a maximum power dissipation of 1.5W. This protects hosts which are not capable of cooling higher power modules which may be accidentally inserted. The module’s 2-wire serial interface and all laser safety functions must be fully functional in this low power mode. During P_Down, the module shall still support the completion of reset Interrupt, as well as maintain functionality of the variable power supply. Mod_NR: The Mod_NR is an output pin that when High, indicates that the module has detected a condition that renders transmitter and or receiver data invalid, shall consist of logical OR of the following signals:

  • Transmit Signal Conditioner Loss of Lock
  • Transmitter Laser Fault
  • Receiver Signal Conditioner Loss of Lock Other conditions deemed valuable to the detection of fault may be added to the Mod_NR. The Mod_NR output pin is an open collector and must be pulled to Host_Vcc on the host board. P_Down/RST: The negative edge of Reset Function signal initiates a complete module reset. Module Behavior During P_Down and RST: During execution of a reset (t_init) or while held in Power Down mode, a module may be unable to determine the correct value for Mod_NR and RX_LOS. These outputs as well as all interrupt related flags, except completion of Reset flag, shall be disregarded by the host. When the module completes a Reset and is not in Power Down mode, the module must represent the correct value of both signals on its outputs before posting a completion of reset interrupt to the host. At no time shall a module cause spurious assertion of the Interrupt pin. When a host initially applies power to a module with the P_Down/RST signal asserted, a module comes up in power down mode. The module shall only assert the Interrupt signal pin to inform the host it has completed a reset. The completion of reset flag shall be the only interrupt source flag set during power down mode. The host is expected to clear this interrupt before releasing the module from the power down mode. The transition from power down mode to normal mode will trigger a reset of the module and result in a 2nd module reset and a 2nd reset completion interrupt to the host. Power Supply and Grounding: The power supply line should be well-filtered. All 0.1μF power supply bypass capacitors should be as close to the transceiver module as possible. Host Board Termination & Coupling R: 4.7 to 10kΩ All caps are in units of µF 50Ω line 50Ω line 50Ω line 50Ω line TD- TD+ RD+ RD- ASIC/ SerDes CM L IN PU TS CM L OU TP UT S +3 .3 V +3 .3 V +3 .3 V SCL, SDA, Mod_Abs, Mod_NR, R R R XFP Interrupt, RX_LOS 6++5 .0V ++3.3V 8, 9 1µH coil or ferrite indu ctor 1µH coil or ferrite indu ctor 0.1 10 0.1 0.1 10 0.1

Oplink Communications, Inc 6 TXD3XGHL2xx S0321. Rev.04. (web) 2014-03-21

Ordering Information

NOTES: UNLESS OTHERWISE SPECIFIED Package Outline Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance Latch Color TXD3XGHL2C00061G - 5°C to +70°C Commercial 1528.77 196.1 61 80km White TXD3XGHL2C00060G - 5°C to +70°C Commercial 1529.55 196.0 60 80km White TXD3XGHL2C00059G - 5°C to +70°C Commercial 1530.33 195.9 59 80km White TXD3XGHL2C00058G - 5°C to +70°C Commercial 1531.12 195.8 58 80km White TXD3XGHL2C00057G - 5°C to +70°C Commercial 1531.90 195.7 57 80km White TXD3XGHL2C00056G - 5°C to +70°C Commercial 1532.68 195.6 56 80km White TXD3XGHL2C00055G - 5°C to +70°C Commercial 1533.47 195.5 55 80km White TXD3XGHL2C00054G - 5°C to +70°C Commercial 1534.25 195.4 54 80km White TXD3XGHL2C00053G - 5°C to +70°C Commercial 1535.04 195.3 53 80km White TXD3XGHL2C00052G - 5°C to +70°C Commercial 1535.82 195.2 52 80km White TXD3XGHL2C00051G - 5°C to +70°C Commercial 1536.61 195.1 51 80km White TXD3XGHL2C00050G - 5°C to +70°C Commercial 1537.40 195.0 50 80km White TXD3XGHL2C00049G - 5°C to +70°C Commercial 1538.19 194.9 49 80km White TXD3XGHL2C00048G - 5°C to +70°C Commercial 1538.98 194.8 48 80km White TXD3XGHL2C00047G - 5°C to +70°C Commercial 1539.77 194.7 47 80km White TXD3XGHL2C00046G - 5°C to +70°C Commercial 1540.56 194.6 46 80km White

Oplink Communications, Inc 7 TXD3XGHL2xx S0321. Rev.04. (web) 2014-03-21 Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance Latch Color TXD3XGHL2E00061G - 5°C to +85°C Extended 1528.77 196.1 61 80km White TXD3XGHL2E00060G - 5°C to +85°C Extended 1529.55 196.0 60 80km White TXD3XGHL2E00059G - 5°C to +85°C Extended 1530.33 195.9 59 80km White TXD3XGHL2E00058G - 5°C to +85°C Extended 1531.12 195.8 58 80km White TXD3XGHL2E00057G - 5°C to +85°C Extended 1531.90 195.7 57 80km White TXD3XGHL2E00056G - 5°C to +85°C Extended 1532.68 195.6 56 80km White TXD3XGHL2E00055G - 5°C to +85°C Extended 1533.47 195.5 55 80km White TXD3XGHL2E00054G - 5°C to +85°C Extended 1534.25 195.4 54 80km White TXD3XGHL2E00053G - 5°C to +85°C Extended 1535.04 195.3 53 80km White TXD3XGHL2E00052G - 5°C to +85°C Extended 1535.82 195.2 52 80km White TXD3XGHL2E00051G - 5°C to +85°C Extended 1536.61 195.1 51 80km White Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance Latch Color TXD3XGHL2C00045G - 5°C to +70°C Commercial 1541.35 194.5 45 80km White TXD3XGHL2C00044G - 5°C to +70°C Commercial 1542.14 194.4 44 80km White TXD3XGHL2C00043G - 5°C to +70°C Commercial 1542.94 194.3 43 80km White TXD3XGHL2C00042G - 5°C to +70°C Commercial 1543.73 194.2 42 80km White TXD3XGHL2C00041G - 5°C to +70°C Commercial 1544.53 194.1 41 80km White TXD3XGHL2C00040G - 5°C to +70°C Commercial 1545.32 194.0 40 80km White TXD3XGHL2C00039G - 5°C to +70°C Commercial 1546.12 193.9 39 80km White TXD3XGHL2C00038G - 5°C to +70°C Commercial 1546.92 193.8 38 80km White TXD3XGHL2C00037G - 5°C to +70°C Commercial 1547.72 193.7 37 80km White TXD3XGHL2C00036G - 5°C to +70°C Commercial 1548.51 193.6 36 80km White TXD3XGHL2C00035G - 5°C to +70°C Commercial 1549.32 193.5 35 80km White TXD3XGHL2C00034G - 5°C to +70°C Commercial 1550.12 193.4 34 80km White TXD3XGHL2C00033G - 5°C to +70°C Commercial 1550.92 193.3 33 80km White TXD3XGHL2C00032G - 5°C to +70°C Commercial 1551.72 193.2 32 80km White TXD3XGHL2C00031G - 5°C to +70°C Commercial 1552.52 193.1 31 80km White TXD3XGHL2C00030G - 5°C to +70°C Commercial 1553.33 193.0 30 80km White TXD3XGHL2C00029G - 5°C to +70°C Commercial 1554.13 192.9 29 80km White TXD3XGHL2C00028G - 5°C to +70°C Commercial 1554.94 192.8 28 80km White TXD3XGHL2C00027G - 5°C to +70°C Commercial 1555.75 192.7 27 80km White TXD3XGHL2C00026G - 5°C to +70°C Commercial 1556.55 192.6 26 80km White TXD3XGHL2C00025G - 5°C to +70°C Commercial 1557.36 192.5 25 80km White TXD3XGHL2C00024G - 5°C to +70°C Commercial 1558.17 192.4 24 80km White TXD3XGHL2C00023G - 5°C to +70°C Commercial 1558.98 192.3 23 80km White TXD3XGHL2C00022G - 5°C to +70°C Commercial 1559.79 192.2 22 80km White TXD3XGHL2C00021G - 5°C to +70°C Commercial 1560.61 192.1 21 80km White TXD3XGHL2C00020G - 5°C to +70°C Commercial 1561.42 192.0 20 80km White TXD3XGHL2C00019G - 5°C to +70°C Commercial 1562.23 191.9 19 80km White TXD3XGHL2C00018G - 5°C to +70°C Commercial 1563.05 191.8 18 80km White TXD3XGHL2C00017G - 5°C to +70°C Commercial 1563.86 191.7 17 80km White

Oplink Communications, Inc 8 TXD3XGHL2xx S0321. Rev.04. (web) 2014-03-21 Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance Latch Color TXD3XGHL2E00050G - 5°C to +85°C Extended 1537.40 195.0 50 80km White TXD3XGHL2E00049G - 5°C to +85°C Extended 1538.19 194.9 49 80km White TXD3XGHL2E00048G - 5°C to +85°C Extended 1538.98 194.8 48 80km White TXD3XGHL2E00047G - 5°C to +85°C Extended 1539.77 194.7 47 80km White TXD3XGHL2E00046G - 5°C to +85°C Extended 1540.56 194.6 46 80km White TXD3XGHL2E00045G - 5°C to +85°C Extended 1541.35 194.5 45 80km White TXD3XGHL2E00044G - 5°C to +85°C Extended 1542.14 194.4 44 80km White TXD3XGHL2E00043G - 5°C to +85°C Extended 1542.94 194.3 43 80km White TXD3XGHL2E00042G - 5°C to +85°C Extended 1543.73 194.2 42 80km White TXD3XGHL2E00041G - 5°C to +85°C Extended 1544.53 194.1 41 80km White TXD3XGHL2E00040G - 5°C to +85°C Extended 1545.32 194.0 40 80km White TXD3XGHL2E00039G - 5°C to +85°C Extended 1546.12 193.9 39 80km White TXD3XGHL2E00038G - 5°C to +85°C Extended 1546.92 193.8 38 80km White TXD3XGHL2E00037G - 5°C to +85°C Extended 1547.72 193.7 37 80km White TXD3XGHL2E00036G - 5°C to +85°C Extended 1548.51 193.6 36 80km White TXD3XGHL2E00035G - 5°C to +85°C Extended 1549.32 193.5 35 80km White TXD3XGHL2E00034G - 5°C to +85°C Extended 1550.12 193.4 34 80km White TXD3XGHL2E00033G - 5°C to +85°C Extended 1550.92 193.3 33 80km White TXD3XGHL2E00032G - 5°C to +85°C Extended 1551.72 193.2 32 80km White TXD3XGHL2E00031G - 5°C to +85°C Extended 1552.52 193.1 31 80km White TXD3XGHL2E00030G - 5°C to +85°C Extended 1553.33 193.0 30 80km White TXD3XGHL2E00029G - 5°C to +85°C Extended 1554.13 192.9 29 80km White TXD3XGHL2E00028G - 5°C to +85°C Extended 1554.94 192.8 28 80km White TXD3XGHL2E00027G - 5°C to +85°C Extended 1555.75 192.7 27 80km White TXD3XGHL2E00026G - 5°C to +85°C Extended 1556.55 192.6 26 80km White TXD3XGHL2E00025G - 5°C to +85°C Extended 1557.36 192.5 25 80km White TXD3XGHL2E00024G - 5°C to +85°C Extended 1558.17 192.4 24 80km White TXD3XGHL2E00023G - 5°C to +85°C Extended 1558.98 192.3 23 80km White TXD3XGHL2E00022G - 5°C to +85°C Extended 1559.79 192.2 22 80km White TXD3XGHL2E00021G - 5°C to +85°C Extended 1560.61 192.1 21 80km White TXD3XGHL2E00020G - 5°C to +85°C Extended 1561.42 192.0 20 80km White TXD3XGHL2E00019G - 5°C to +85°C Extended 1562.23 191.9 19 80km White TXD3XGHL2E00018G - 5°C to +85°C Extended 1563.05 191.8 18 80km White TXD3XGHL2E00017G - 5°C to +85°C Extended 1563.86 191.7 17 80km White Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance Latch Color TXD3XGHL2I00061G - 40°C to +85°C Industrial 1528.77 196.1 61 80km White TXD3XGHL2I00060G - 40°C to +85°C Industrial 1529.55 196.0 60 80km White TXD3XGHL2I00059G - 40°C to +85°C Industrial 1530.33 195.9 59 80km White TXD3XGHL2I00058G - 40°C to +85°C Industrial 1531.12 195.8 58 80km White TXD3XGHL2I00057G - 40°C to +85°C Industrial 1531.90 195.7 57 80km White TXD3XGHL2I00056G - 40°C to +85°C Industrial 1532.68 195.6 56 80km White

46335 Landing Pkwy Fremont, CA 94538 T el: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com • www.oplink.com TXD3XGHL2xx Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Com- munications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringe- ments of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. © 2014, Oplink Communications, Inc. S0321. Rev.04. (web) 2014-03-21 Model Name Operating Temperature Center Wavelength (nm) ITU Frequency (THz) Wavelength Reference Distance Latch Color TXD3XGHL2I00055G - 40°C to +85°C Industrial 1533.47 195.5 55 80km White TXD3XGHL2I00054G - 40°C to +85°C Industrial 1534.25 195.4 54 80km White TXD3XGHL2I00053G - 40°C to +85°C Industrial 1535.04 195.3 53 80km White TXD3XGHL2I00052G - 40°C to +85°C Industrial 1535.82 195.2 52 80km White TXD3XGHL2I00051G - 40°C to +85°C Industrial 1536.61 195.1 51 80km White TXD3XGHL2I00050G - 40°C to +85°C Industrial 1537.40 195.0 50 80km White TXD3XGHL2I00049G - 40°C to +85°C Industrial 1538.19 194.9 49 80km White TXD3XGHL2I00048G - 40°C to +85°C Industrial 1538.98 194.8 48 80km White TXD3XGHL2I00047G - 40°C to +85°C Industrial 1539.77 194.7 47 80km White TXD3XGHL2I00046G - 40°C to +85°C Industrial 1540.56 194.6 46 80km White TXD3XGHL2I00045G - 40°C to +85°C Industrial 1541.35 194.5 45 80km White TXD3XGHL2I00044G - 40°C to +85°C Industrial 1542.14 194.4 44 80km White TXD3XGHL2I00043G - 40°C to +85°C Industrial 1542.94 194.3 43 80km White TXD3XGHL2I00042G - 40°C to +85°C Industrial 1543.73 194.2 42 80km White TXD3XGHL2I00041G - 40°C to +85°C Industrial 1544.53 194.1 41 80km White TXD3XGHL2I00040G - 40°C to +85°C Industrial 1545.32 194.0 40 80km White TXD3XGHL2I00039G - 40°C to +85°C Industrial 1546.12 193.9 39 80km White TXD3XGHL2I00038G - 40°C to +85°C Industrial 1546.92 193.8 38 80km White TXD3XGHL2I00037G - 40°C to +85°C Industrial 1547.72 193.7 37 80km White TXD3XGHL2I00036G - 40°C to +85°C Industrial 1548.51 193.6 36 80km White TXD3XGHL2I00035G - 40°C to +85°C Industrial 1549.32 193.5 35 80km White TXD3XGHL2I00034G - 40°C to +85°C Industrial 1550.12 193.4 34 80km White TXD3XGHL2I00033G - 40°C to +85°C Industrial 1550.92 193.3 33 80km White TXD3XGHL2I00032G - 40°C to +85°C Industrial 1551.72 193.2 32 80km White TXD3XGHL2I00031G - 40°C to +85°C Industrial 1552.52 193.1 31 80km White TXD3XGHL2I00030G - 40°C to +85°C Industrial 1553.33 193.0 30 80km White TXD3XGHL2I00029G - 40°C to +85°C Industrial 1554.13 192.9 29 80km White TXD3XGHL2I00028G - 40°C to +85°C Industrial 1554.94 192.8 28 80km White TXD3XGHL2I00027G - 40°C to +85°C Industrial 1555.75 192.7 27 80km White TXD3XGHL2I00026G - 40°C to +85°C Industrial 1556.55 192.6 26 80km White TXD3XGHL2I00025G - 40°C to +85°C Industrial 1557.36 192.5 25 80km White TXD3XGHL2I00024G - 40°C to +85°C Industrial 1558.17 192.4 24 80km White TXD3XGHL2I00023G - 40°C to +85°C Industrial 1558.98 192.3 23 80km White TXD3XGHL2I00022G - 40°C to +85°C Industrial 1559.79 192.2 22 80km White TXD3XGHL2I00021G - 40°C to +85°C Industrial 1560.61 192.1 21 80km White TXD3XGHL2I00020G - 40°C to +85°C Industrial 1561.42 192.0 20 80km White TXD3XGHL2I00019G - 40°C to +85°C Industrial 1562.23 191.9 19 80km White TXD3XGHL2I00018G - 40°C to +85°C Industrial 1563.05 191.8 18 80km White TXD3XGHL2I00017G - 40°C to +85°C Industrial 1563.86 191.7 17 80km White