30W, Triple Output DC/DC Converters MDC_TWR30.B02 Page 1 of 5 For full details go to www.murata-ps.com/rohs www.murata-ps.com Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000

FEATURES

/square6 Independently regulated 3.3V and ±12V or ±15V outputs /square6 3.3V @ 4.25A and ±12V @ ±625mA or ±15V @ ±500mA /square6 30 Watts output power /square6 87% efficiency; 75mV ripple/noise /square6 Input ranges: 18-36V or 36-75V /square6 2" x 2" plastic package /square6 Designed to meet UL 1950 and EN60950 safety approvals /square6 Fully isolated, 1500Vdc guaranteed /square6 Basic Insulation transformer construction /square6 Input under and overvoltage shutdown /square6 Independent OVP; Short circuit protection /square6 Thermal shutdown Unlike topologies that provide auxiliary bipolar secondary voltages, the TWR-3.3/4250-12/625 and TWR-3.3/4250-15/500 have fully regulated bipolar control loops that offer the same ±1% load regula- tion seen on the 3.3V primary output. Available with input ranges of 18 to 36V (-D24), or 36 to 75V (-D48), this TWR series offers 87% effi- ciency, ±1% line regulation, input overvoltage and undervoltage shutdown circuitry, output overvolt- age and short circuit protection, as well as current limiting protection and thermal shutdown. TWR triple output converters will deliver full output power in ambient, still air environments rang- ing from –40 to +65°C. Designed using Basic Insulation transformer construction, this family of converters guarantees 1500Vdc of isolation voltage and meets IEC950, UL1950 and EN60950 safety standards. "D48" models are CE marked (meet LVD requirements). SIMPLIFIED SCHEMATIC PRODUCT OVERVIEW This family of triple output DC/DC converters was developed for xDSL line card applications. Two independently regulated converters in a 2" x 2" x 0.5" plastic package offer 3.3V @ 4.25A and ± 12V @ ±625mA or ± 15V @ ±500mA. 37)4#( #/.42/, /./&& #/.42/, ).054 5.$%26/,4!'% !.$/6%26/,4!'% #/-0!2!4/23 n6/54054 /54054 2%452. 6). n6). 07- #/.42/,,%2 /04/ )3/,!4)/. 2%&%2%.#% %22/2!-0 07- #/.42/,,%2 /04/ )3/,!4)/. 2%&%2%.#% %22/2!-0 Typical topology is shown Ḥ

30W, Triple Output DC/DC Converters MDC_TWR30.B02 Page 2 of 5 Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com PERFORMANCE SPECIFICATIONS AND ORDERING GUIDE 1 Model Family Output Input Efficiency5 Package (Case/ Pinout) VOUT (V) IOUT 2 (mA) R/N (mVp-p)3 Regulation VIN Nom. (Volts) Range (Volts) IIN 5 (mA)Typ. Max. Line Load 4 Min. Typ. 1 Typical at TA = +25°C under nominal line voltage and maximum ouput currents. 2 Any combination of +3.3V and ±12V/±15V rated output current, not to exceed the published I OUT specification (30 Watts). 3 Ripple/Noise (R/N) measured over a 20MHz bandwidth, specified with 0.2μF ceramic output capacitors. 4 Tested from 10% load to 100% load, other outputs at maximum load. 5 Nominal line voltage, no-load/full-load conditions. PART NUMBER STRUCTURE * Contact Murata Power Solutions Technologies for availability. MECHANICAL SPECIFICATIONS INPUT/OUTPUT CONNECTIONS Pin Function P31 1 +Input 2 -Input

3 No Pin

4 On/Off Control

6 +3.3V Output

7 Common

Configuration: T = Triple Nominal Primary Output: Voltage (+3.3V) T WR - / 12-3.3 4250 625 D48 Nominal Auxiliary Output: Voltages (±12 or ±15V) Maximum Auxilliary Output: Currents in mA from each output Input Voltage Range: D24 = 18-36V (24V nominal) D48 = 36-75V (48V nominal) C RoHS-6 hazardous substance compliant* -/ - Case C22 "/44/-6)%7 0,!34)##!3% Ò$)! Ò -). %130 34!.$/&& Output Power (Watts) Ambient Temperature (oC) – 4 0 0 4 04 55 05 5 6 06 57 0 7 58 08 59 0 9 5 1 0 0 Third Angle Projection Dimensions are in inches (mm shown for ref. only). Components are shown for reference only. Tolerances (unless otherwise specified): .XX ± 0.02 (0.5) Angles ± 2˚

30W, Triple Output DC/DC Converters MDC_TWR30.B02 Page 3 of 5 Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com Performance/Functional Specifications Typical @ TA = +25°C under nominal line voltage, full-load conditions, unless noted. /onesans Input Input Voltage Range: D24 Models 18-36 Volts (24V nominal) D48 Models 36-75 Volts (48V nominal) Overvoltage Shutdown: D24 Models 37-40 Volts (38V nominal) D48 Models 77-81 Volts (79V nominal) Start-Up Threshold: /twosans D24 Models 16-18 Volts (17V nominal) D48 Models 34-36 Volts (35V nominal) Undervoltage Shutdown: /twosans D24 Models 16-17.5 Volts (16.5V nominal) D48 Models 32-35.5 Volts (34.5V nominal) Input Current: Normal Operating Conditions See Ordering Guide Standby Mode: Off, OV, UV, Thermal Shutdown 10mA Input Reflected Ripple Current: Source Impedance: D24 Models 200mAp-p max., 140mAp-p (typ.) D48 Models 200mAp-p max., 140mAp-p (typ.) Internal Input Filter Type Pi (0.039μF - 2.2μH - 3.3μF) Reverse-Polarity Protection: /twosans D24 Models 1 minute duration, 4A maximum D48 Models 1 minute duration, 2A maximum On/Off Control (Pin 4) /twosans/threesans/foursans/sixsans On = open or 13V to +V IN, I IN = 50μA @ 13V Off = 0-0.8V, I IN = 1mA @ 0V Output VOUT Accuracy: 3.3V Output ±1.5% ±12V/±15V Output ±2% Ripple/Noise (20MHz BW) /fivesans See Ordering Guide Line/Load Regulation See Ordering Guide Efficiency See Ordering Guide Minimum Loading Per Specification: +3.3V Output 10% of I OUT maximum ±12V/±15V Output ±30mA Minimum Loading For Stability /eightsans No load Isolation Voltage: Input-to-Output 1500Vdc minimum Input-to-Case Plastic case Ouput-to-Case Plastic case Isolation Capacitance 470pF Isolation Resistance 100M Ω Current Limit Inception: 3.3V @ 97%V OUT (±12/±15V @ IOUT max.) 5.8-7.5 Amps (model dependent) ±12V @ 97%V OUT (+3.3V @ IOUT max.) 0.825-1.35 Amps ±15V @ 97%V OUT (+3.3V @ IOUT max.) 0.625-1.15 Amps Temperature Coefficient ±0.02% per °C Output (continued) Short Circuit Current: 3.3V Output 2.5 Amps average, continuous ±12V/±15V Output 2.0 Amps average, continuous Overvoltage Protection: /twosans Magnetic feedback, transorb 3.3V Output 4.2Vdc ±12V Output 30Vdc (±15V differential) ±15V Output 36Vdc (±18V differential) Maximum Capacitive Loading: 3.3V Models 1000μF 5V Models 680μF Dynamic Characteristics Dynamic Load Response: 3.3V (50-100% step to 2%V OUT) 300μsec maximum ±12V/±15V (50-100% step to 2%V OUT) 300μsec maximum Start-Up Time: /twosans V IN to VOUT: 3.3V 10msec ±12V/±15V 15msec On/Off to V OUT 10msec Switching Frequency 350kHz (±30kHz) Environmental MTBF: /sevensans D24 Models TBC D48 Models TBC Operating Temperature (Ambient): /twosans Without Derating: D24 Models –40 to +55°C D48 Models –40 to +55°C With Derating To +100°C (See Derating Curves) Case Temperature: Maximum Operational +100°C For Thermal Shutdown +110°C minimum, +118°C maximum Storage Temperature –40 to +120°C Physical Dimensions 2" x 2" x 0.5" (50.8 x 50.8 x 12.7mm) Case Material Diallyl phthalate, UL94V-0 rated Pin Material Gold plate over copper alloy Weight: 2.47 ounces (70g) Primary to Secondary Insulation Level Basic /onesans All models are specified with external 0.2μF ceramic output capacitors. /twosans See Technical Notes/Graphs for details. /threesans The On/Off control function can be replaced with a Sync function. See Part Number Suffixes and Technical Notes for details. /foursans Applying a voltage to On/Off Control (pin 4) when no input power is applied to the converter can cause permanent damage. /fivesans Output noise may be further reduced with the installation of additional external output capacitors. See Technical Notes. /sixsans On/Off control is designed to be driven with open collector or by appropriate voltage levels. Voltages must be referenced to the input return pin (–Input). /sevensans Demonstrated MTBF available on request. /eightsans For conditions with less than minimum loading, outputs remain stable. However, regulation performance will degrade.

30W, Triple Output DC/DC Converters MDC_TWR30.B02 Page 4 of 5 Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com Absolute Maximum Ratings Input Voltage: Continuous: D24A Models 42 Volts D48A Models 81 Volts Transient (100msec): D24A Models 50 Volts D48A Models 100 Volts Input Reverse-Polarity Protection /twosans Input Current must be limited. 1 minute duration. Fusing recommended. D24A Models 4 Amps D48A Models 2 Amps Output Current /twosans Current limited. Devices can withstand an indefinite output short circuit. On/Off Control (Pins 3 & 4) Max. Voltages Referenced to –Input (pin 2) No Suffix +V IN "S" Suffix +5.7 Volts Storage Temperature –40 to +120°C Lead Temperature See soldering guidelines These are stress ratings. Exposure of devices to greater than any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied, nor recommended. Start-Up Threshold and Undervoltage Shutdown Under normal start-up conditions, TWR 30W triples will not begin to regulate until the ramping input voltage exceeds the Start-Up Threshold Voltage (typically 17V for "D24" models and 35V for "D48" models). Once operating, devices will not turn off until the input voltage drops below the Undervoltage Shutdown/Lockout limit (typically 16.5V for "D24" models and 34.5V for "D48" models). Subsequent re-start will not occur until the input is brought back up to the Start-Up Threshold. This built-in hysteresis obviously avoids any indeterminate on/off conditions at a single voltage. Start-Up Time For all models in the TWR 30W Series, VIN to VOUT Start-Up Time is the interval between the time at which a rapidly ramping input voltage crosses the turn-on threshold point and the fully loaded output voltages enter and remain within their specified accuracy bands. Actual measured times will vary with output capacitance and load. The On/Off to V OUT Start-Up Time assumes the converter is turned off via the On/Off Control with the nominal input voltage already applied to the con- verter. The specification defines the interval between the time at which the converter is turned on and the fully loaded output voltages enter and remain within their specified accuracy bands. On/Off Control The On/Off Control pin (pin 4) is provided for remote on/off operation. TWR 30W Series converters are designed so that they are enabled when the control pin is pulled high or left open (normal mode) and disabled when the control pin is pulled low (to less than +0.8V relative to –Input, pin 2). Dynamic control of the on/off function is best accomplished with a mechani- cal relay or an open-collector/open-drain drive circuit (optically isolated if appropriate). The drive circuit should be able to sink appropriate current (see Performance/Functional Specifications) when activated.. Applying an external voltage to pin 4 when no input power is applied to the converter can cause permanent damage to the converter. The on/off control function, however, is designed such that the converter can be disabled (pin 4 pulled low) while input power is ramping up and then "released" once the input has stabilized. The time duration between the point at which the con- verter is released and its fully loaded output voltage settles to within specified accuracy can be found in the Performance/Functional Specifications. I/O Filtering and Noise Reduction All TWR 30W Series models achieve their rated ripple and noise specifica- tions without the use of external input/output capacitors. In critical applica- tions, input/output ripple/noise may be further reduced by installing additional external I/O caps. Input capacitors, which function primarily as energy- storage elements, should be selected for bulk capacitance, low ESR and high rms-ripple-current ratings. Output capacitors, which function more as true filter elements, should be selected for bulk capacitance, low ESR, and appropriate frequency response. All caps should have appropriate voltage ratings and be mounted as close to the converters as possible. Temperature variations for all parameters should obviously be taken into consideration. Input Fusing Certain applications and/or safety agencies may require the installation of fuses at the inputs of power conversion components. Fuses should also be used if the possibility of sustained, non-current-limited, input-voltage polarity reversals exists. For DATEL TWR 30W DC/DC Converters, you should use slow-blow type fuses with values no greater than the following. Model Number Fuse Value TWR-3.3/4250-12/625-D24 4 Amps TWR-3.3/4250-12/625-D48 2 Amps TWR-3.3/4250-15/500-D24 4 Amps TWR-3.3/4250-15/500-D48 2 Amps TECHNICAL NOTES

30W, Triple Output DC/DC Converters MDC_TWR30.B02 Page 5 of 5 Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2008 Murata Power Solutions, Inc. USA: Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Canada: Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com UK: Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com France: Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Germany: München, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Japan: Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com China: Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000www.murata-ps.com 11/13/08 Typical Performance Curves 472 %FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT —# ,OAD#URRENT!MPS %FFICIENCY 6). 6). 6). 6). 472 %FFICIENCYVS,INE6OLTAGEAND,OAD#URRENT —# ,OAD#URRENT!MPS %FFICIENCY 6). 6). 6). 6). Soldering Guidelines Murata Power Solutions recommends the specifications below when installing these converters. These specifications vary depending on the solder type. Exceeding these specifica- tions may cause damage to the product. Be cautious when there is high atmospheric humidity. We strongly recommend a mild pre-bake (100° C. for 30 minutes). Your production environment may differ; therefore please thoroughly review these guidelines with your process engineers. Wave Solder Operations for through-hole mounted products (THMT) For Sn/Ag/Cu based solders: For Sn/Pb based solders: Maximum Preheat Temperature 115° C. Maximum Preheat Temperature 105° C. Maximum Pot Temperature 270° C. Maximum Pot Temperature 250° C. Maximum Solder Dwell Time 7 seconds Maximum Solder Dwell Time 6 seconds