Technical content

Ashcroft offers the assembly of SMART transmitters to our diaphragm seals and isolation rings, ensuring that your pressure assemblies are tested for accuracy and leak integrity prior to shipment. Our transmitter assembly service helps to take the guesswork out of specifying the correct pressure instrumentation and assembly orientation, while our Ashcroft instrumentation experts ensure that the instruments are compatible and properly calibrated to suit your application. Selection is easy: choose the transmitter you want us to attach and configure the appropriate assembly code according to the instructions in this document. We’ll build the assembly with our custom-made low volume fittings for minimal temperature error, fill the assembly with our state-of-the-art vacuum filling system, and ensure that every instrument in the assembly is checked for calibration prior to shipment. To ensure compatibility with the seal or isolation ring being attached, we recommend the following: ■ Note the instrument connection: make sure all instruments being attached are the same size NPT ■ Note the required output span – make sure it does not exceed the pressure rating of the isolator or the ranges of any attached instrument. ■ Remove any option codes for block and bleed valves from the transmitter manufacturer part number– these cannot be installed above a diaphragm seal. If in doubt, submit the form found at https://bit.ly/transmitterform and we’ll respond within 24 hours with our recommendations. Refer to the coding table on pages 2 thru 3 to select the appropriate coding for the assembly orientation you need. When ordering, be sure to include the full transmitter part number somewhere on the purchase order. Refer to the respective data sheets to configure part numbers for isolation rings, seals, and any other instrument included on the assembly. (see coding example on page 4) Working through your Ashcroft sales representative or authorized distributor, submit your order. Once it has been entered into our system, we will issue a return authorization number for your transmitters. Step 2: - Configure the Assembly Part Number Step 3: - Send us your SMART Transmitter Step 1: - Transmitter Selection Ordering Guide Ashcroft SMART Transmitter Assemblies of 41 All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. SMART_og_RevB_08-19-20 ashcroft.com info@ashcroft.com 1.800.328.8258

ORDERING CODE Example: TS A 04 0 A001 T 0 0 CK 0/60# -XC4NH7G Transmitter Seal Assembly TS Transmitter Manufacturer A - Emerson/Rosemont A B - Endress & Hauser C - Siemens D - Foxboro/SE E - Yokogawa F - ABB G - Vega Transmitter Process Connection 04 - ½ NPT Male 04 02 - ¼ NPT Male 50 - ½ NPT Female 25 - ¼ NPT Female Orientation Options 0 - Horizontal pipe 0 E - Vertical pipe (includes elbow, ¼ NPT connections only) Instrument Arrangement A001 - Direct attachment A001 A002 - Single instrument with 1115 capillary line or 2198 MicroTube™ siphon A003 - Differential transmitter (attached with 1115 capillary) A004 - Single instrument with snubber/dampener B001 - 2 Instruments; right-facing tee (½ NPT connections) B002 - 2 Instruments; right-facing tee (¼ NPT connections) B003 - 2 Instruments; left-facing tee (½ NPT connections) B004 - 2 Instruments; left-facing tee (¼ NPT connections) C001 - 3 Instruments on cross fitting (½ NPT connections) C002 - 3 Instruments on cross fitting (¼ NPT connections) C003 - 3 Instruments on cross w/capillary (¼ NPT connections) Contact factory for additional/custom orientations Instrument at 12:00 T - Customer-supplied instrument T G - Analog gauge S - Switch D - Transducer/digital gauge Instrument at 3:00 (select instrument for right-facing B and C arrangement) 0 - No instrument 0 T - Customer -supplied instrument G - Analog gauge S - Switch D - Transducer/digital gauge Instrument at 9:00 (select instrument for left-facing B and C arrangement) 0 - No instrument 0 T - Customer -supplied instrument G - Analog gauge S - Switch D - Transducer/digital gauge Ordering Guide Ashcroft SMART Transmitter Assemblies of 42 All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. SMART_og_RevB_08-19-20 ashcroft.com info@ashcroft.com 1.800.328.8258

ORDERING CODE (continued) Example: TS A 04 0 A001 T 0 0 CK 0/60# -XC4NH7G Fill Fluids DJ - 10 cSt Silicone CK - 50 cSt Silicone CK CG - Glycerin CF - Halocarbon HA - Syltherm 800 CC - Syltherm XLT NM - Neobee M20 Specify Desired Transmitter Output Range (use V for full vacuum, N for negative) [Output @ 4mA] e.g. 0/60# [Output @ 20mA] Options (include "X" if selecting options) -X C4 - Certifed calibration chart C4 6B - Cleaning for oxygen service (must select Halocarbon fill) 6W - Cleaning for oxidizer service NH - Metal assembly tagging NH KH - Custom calibration requirements (e.g. mounting offset) 1H - Hydrostatic testing 7G - Note: Include 7G in all instrument part numbers included in assembly 7G Ordering Guide Ashcroft SMART Transmitter Assemblies of 42 All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. SMART_og_RevB_08-19-20 ashcroft.com info@ashcroft.com 1.800.328.8258 of 43 All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. SMART_og_RevB_08-19-20 ashcroft.com info@ashcroft.com 1.800.328.8258

B001 - Transmitter installed on right-facing tee (½ NPT) A002 - Transmitter with Heat Dissipator and Isolater A001 - Direct Attachment Assembly Examples TS C 04 0 A001 T00 04: ½ NPT male transmitter connection 0: No elbow A001: Direct attachment T00: Transmitter at 12:00 TS C 02 E A001 T00 02: ¼ NPT male transmitter connection E: Elbow for vertical pipe install A001: Direct attachment T00: Transmitter at 12:00 TS C 04 0 A002 T00 04: ½ NPT male transmitter connection 0: No elbow A002: Instrument with heat dissipater T00: Transmitter at 12:00 TS C 50 0 B001 GT0 50: ½ NPT female transmitter connection 0: No elbow B001: Right-facing tee GT0: Gauge at 12:00, Transmitter at 3:00 Part Number Ordering Example Gauge: 451279SS04LXCK7G100# Isolation Ring: 8006ESB04TN000XCK7G Assembly: TSC500B001GT0CK0/100#-XCK7G Ordering Guide Ashcroft SMART Transmitter Assemblies of 44 All specifications are subject to change without notice. All sales subject to standard terms and conditions. ©2020 Ashcroft Inc. SMART_og_RevB_08-19-20 ashcroft.com info@ashcroft.com 1.800.328.8258