© 2016 Littelfuse Protection Relays & Controls Time Delay Relays Dedicated - Single Shot Rev: 1-A-062216 www.littelfuse.com/tsds TSDS SERIES Wiring Diagram
Description
The TSDS Series is designed for more demanding commercial and industrial applications where small size and accurate performance are required. The factory calibration for fixed time delays is within 1% of the target time delay. The repeat accuracy, under stable conditions, is 0.5% of the time delay. The TSDS Series is rated to operate over an extended temperature range. Time delays of 0.1 seconds to 1000 minutes are available. The output is rated 1A steady and 10A inrush. The modules are totally solid state and encapsulated to protect the electronic circuitry. This product is suitable for many applications, including dispensing, welding, and exposure timing. Operation (Single Shot) Input voltage must be applied before and during timing. Upon momentary or maintained closure of the initiate switch, the output energizes for a measured interval of time. At the end of the delay, the output de-energizes. Opening or reclosing the initiate switch during timing has no affect on the time delay. The output will not energize if the initiate switch is closed when input voltage is applied. Reset: Reset occurs when the time delay is complete and the initiate switch is opened. Loss of input voltage resets the time delay and output. Features & Benefits FEATURES BENEFITS Compact, low cost design measuring 2 in. (50.8mm) square Allows flexiblility for OEM applications Microcontroller based Repeat Accuracy + / - 0.5%, Factory calibration + / - 1% 1A Steady, 10A inrush solid-state output Provides 100 million operations in typical conditions. T otally solid state and encapsulated No moving parts to arc and wear out over time and encapsulated to protect against shock, vibration, and humidity Wide temperature range: -40° to 75°C Reliable in demanding commercial and industrial applications Accessories P1004-95, P1004-95-X Versa-Pot Panel mountable, industrial potentiometer recommended for remote time delay adjustment. P1023-6 Mounting bracket The 90° orientation of mounting slots makes installation/removal of modules quick and easy. P0700-7 Versa-Knob Designed for 0.25 in (6.35 mm) shaft of Versa-Pot. Semi-gloss industrial black finish. V = Voltage L = Timed Load UTL = Optional Untimed Load S1 = Initiate Switch RT is used when external adjustment is ordered. L1 N/L2 (Positive Switching) (Negative Switching)
Ordering Information
VOLTAGE ADJUSTMENT TIME DELAY SWITCHING MODE TSDS2110S 24VAC Fixed 10s n/a TSDS320N 24VDC External 0.1 - 10s Negative TSDS321P 24VDC External 1 - 100s Positive TSDS421 120VAC External 1 - 100s n/a If you don’t find the part you need, call us for a custom product 800-843-8848
© 2016 Littelfuse Protection Relays & Controls Time Delay Relays Dedicated - Single Shot Rev: 1-A-062216 www.littelfuse.com/tsds TSDS SERIES Accessories P1015-64 (AWG 14/16) Female Quick Connect These 0.25 in. (6.35 mm) female terminals are constructed with an insulator barrel to provide strain relief. P1015-18 Quick Connect to Screw Adapter Screw adapter terminal designed for use with all modules with 0.25 in. (6.35 mm) male quick connect terminals. C103PM (AL) DIN Rail 35 mm aluminum DIN rail available in a 36 in. (91 .4 cm) length. P1023-20 DIN Rail Adapter Allows module to be mounted on a 35 mm DIN type rail with two #10 screws. External Resistance vs. Time Delay This chart applies to externally adjustable part numbers. The time delay is adjustable over the time delay range selected by varying the resistance across the RT terminals; as the resistance increases the tie delay increases. When selecting an external RT, add the tolerances of the timer and the RT for the full time range adjustment. Examples: 1 to 50 S adjustable time delay, select time delay range 1 and a 50 K ohn RT. For 1 to 100 S use a 100 K ohm RT. Function Diagram SINGLE SHOT (PULSE FORMER) V = Voltage S1 = Initiate Switch NO = Normally Open Contact NC = Normally Closed Contact TD = Time Delay R = Reset Specifications Time Delay Range 0.1s - 1000m in 6 adjustable ranges or fixed Repeat Accuracy ±0.5% or 20ms, whichever is greater Tolerance (Factory Calibration) ≤ ±1% Reset Time ≤ 150ms Initiate Time ≤ 20ms Time Delay vs Temp. & Voltage ≤ ±2% Input Voltage 12 or 24VDC; 24, 120, or 230VAC Tolerance ±15% Power Consumption AC ≤ 2VA; DC ≤ 1W AC Line Frequency/DC Ripple 50/60 Hz / ≤ 10% Output Type Solid state Form NO, closed during timing Maximum Load Current 1A steady state, 10A inrush at 60°C Voltage Drop AC ≅ 2.5V @ 1A; DC ≅ 1V @ 1A Off State Leakage Current AC ≅ 5mA @ 230VAC; DC ≅ 1mA DC Operation Positive or negative switching Protection Circuitry Encapsulated Dielectric Breakdown ≥ 2000V RMS terminals to mounting surface Insulation Resistance ≥ 100 MΩ Polarity DC units are reverse polarity protected Mechanical Mounting Surface mount with one #10 (M5 x 0.8) screw Dimensions H 50.8 mm (2.0”); W 50.8 mm (2.0”); D 30.7 mm (1.21”) Termination 0.25 in. (6.35 mm) male quick connect terminals Environmental Operating/Storage Temperature -40° to 75°C / -40° to 85°C Humidity 95% relative, non-condensing Weight ≅ 2.4 oz (68 g)