TS13101 SEMTECH | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 10

Technical content

Features

  • Low Quiescent Operating Currents Œ 2uA in OFF state Œ 4uA in ON state
  • Scalable galvanic isolation from primary to secondary sides of the device
  • Single control signal for on/off input (CLK) Œ Operation from 2.9V to 5.5V compatible with standard microcontrollers
  • Switch Characteristics Œ High voltage switch with bi-directional blocking in OFF state Œ Single switch device Œ 60V switch and 110mohm Rdson Œ Up to 4A operating current Specification
  • Junction operating temperature -40 °C to 125 °C
  • Packaged in a 20pin QFN (4x4) Galvanic Isolated Latching 60V Power Load Switch

Description

The TS13101 is a galvanically isolated 60V power switch device with bi-directional blocking. The device includes a single integrated 110mOhm high voltage FET allowing high efficiency switching of power loads or other high current applications. The input pin, CLK, controls the turn on/off of the switch. When the correct CLK sequence is provided the switch will latch on and stay on until the turn off sequence is given or a fault is detected. The TS13101 includes several protection features. Each FET has an integrated over-current shut-down to prevent device damage during short-circuit or other unusually high load conditions. If an over-current event is detected for a time the FET is latched off until the CLK turn off sequence is given. While the CLK pin is active after an over-current event or in the event of an incorrect turn-on sequence, the DATA pin is toggled at ¼ the CLK frequency.

Applications

  • Power load/rail switching
  • Input supply muxing
  • Isolated power supplies
  • Solid state relays
  • HVAC control Typical Application Circuit uC VCC GPIO1 Load VAC CLK SRC VDD1 SW1 SW2 CISO GPIO2 Cdata DATA VDD2 SUB CPP Ccp Csub VCC SYSP Csys SYSM

Final Datasheet Rev 1.0 October 22, 2015 www.semtech.com 2 of 10 Semtech Pin Description Pin # Pin Name Pin Function Description

1 SRC GND

2 SW2 Switch Output Node 2

3 SW1 Switch Output Node 1

4 SW1 Switch Output Node 1

5 SW2 Switch Output Node 2

6 SW1 Switch Output Node 1

7 SW2 Switch Output Node 2

8 SW2 Switch Output Node 2

9 DATA Data Output AC Coupled Data Output

10 CLK Clock Input AC Coupled Clock and Power Input

11 SYSP Positive System Voltage

12 CPP Charge Pump Cap Additional Cap used for lower voltage Clock drive

13 VDD1 Internal Supply 1 Bypass Capacitor for Internal Supply

14 VDD2 Internal Supply 2 Bypass Capacitor for Internal Supply

15 NC No Connect

16 SUB GND2

17 NC No Connect

18 SW1 Switch Output Node 1

19 SW1 Switch Output Node 1

20 SW2 Switch Output Node 2

PAD PAD Power PAD Must be floating or connected to SUB

Final Datasheet Rev 1.0 October 22, 2015 www.semtech.com 3 of 10 Semtech Functional Block Diagram Figure 1: TS13101 Block Diagram Absolute Maximum Rating Over operating free–air temperature range unless otherwise noted(1, 2, 3) Parameter Range UNIT SW1, SW2, SYSP (Peak Voltage) -60 to 60 V CLK, CLK2, DATA, VDD1, VDD2, CPP -0.3 to 5.5 V SUB -60 to 0.3 V Operating Junction Temperature Range, TJ -40 to 125 °C Storage Temperature Range, TSTG -65 to 150 °C Electrostatic Discharge – Human Body Model ±2k V Electrostatic Discharge – Machine Model +/-200 V Electrostatic Discharge – IEC Contact (SW1 and SW2 pins) ±8k V Electrostatic Discharge – IEC Air Discharge (SW1 and SW2 pins) ±15k V Lead Temperature (soldering, 10 seconds) 260 °C Notes: (1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability. (2) All voltage values are with respect to SRC terminal. (3) ESD testing is performed according to the respective JESD22 JEDEC standard. Digital Control Switch Driver Ilimit Detect VDD1 CLK SUB VDD1 SW1 SW2DATA VDD2 VDD2 SRC CPP SYSP

Final Datasheet Rev 1.0 October 22, 2015 www.semtech.com 4 of 10 Semtech Thermal Characteristics Symbol Parameter Value Units ΘJA Thermal Resistance Junction to Air (Note 1) 25 °C/W ΘJC Thermal Resistance Junction to Case (Note 1) 2.5 °C/W TSTG Storage Temperature Range -65 to 150 °C TJ MAX Maximum Junction Temperature 150 °C TJ Operating Junction Temperature Range -40 to 125 °C Note 1: Assumes 20LD 4x4 QFN with hi-K JEDEC board and 13.5 inch2 of 1 oz Cu and 4 thermal vias connected to PAD Recommended Operating Conditions Symbol Parameter Min Typ Max Unit VSW AC Switch Voltage (RMS Voltage) -36 36 V CDATA Data Isolation Capacitor 100 pF CISO Clock Isolation Capacitor 680 pF CCP Charge Pump Capacitor 100 pF CVDD1 VDD1 Bypass Capacitor 10 nF CVDD2 VDD2 Bypass Capacitor 1 uF CSUB Sub Capacitor 100 nF CSYS System Bypass Capacitor 100 nF CCLK2 Clock2 Isolation Capacitor 680 pF

Final Datasheet Rev 1.0 October 22, 2015 www.semtech.com 5 of 10 Semtech Characteristics Electrical Characteristics, TJ = -40C to 125C, VCC = 12V (unless otherwise noted) Symbol Parameter Condition Min Typ Max Unit Supply Voltage VCLK Clock Drive Voltage 5.5 V ICLK-NORM Quiescent current VCLK = 5.0V, FCLK = 500KHz 2.9 15 uA ICLK-NORM Normal Mode, CLK running VCLK = 3.0V, FCLK = 1000KHz 50 uA ICLK-STBY Quiescent current VCLK = 0V 3 uA ISYSP Normal Mode, CLK running Latch Mode 3 5 uA VCLK Drive FCLK Clock Frequency to Turn on Switch 300 2000 KHz FDATA Data Frequency during Current Shutdown FCLK/4 KHz NCLKON-INIT Number of CLK pulses to initialize Turn On 3 8 TLOW-ON CLK Low time during Turn On Sequence 10 20 uS NCLKON CLK Pulses to Turn on SW After TLOW-ON TFASTOFF-INIT CLK Low time to Initialize Fast Turn- Off 10 20 uS NCLK-FOEN CLK Pulses to Enable Fast Turn-Off After TFASTOFF-INIT 6 13 TOFF-FAST Time for Turn Off Fast Mode 4 10 uS NCLK-OFFDET CLK Pulses to Detect Incorrect Turn- On Sequence Resets with TLOW-ON 19 Output Switch RON On Resistance TJ=-10C to 65C 75 105 150 mΩ RON On Resistance TJ=25C 90 105 130 mΩ IOFF Off State Leakage 3 uA IOUTOC Output Over Current Shutdown TJ=-40C to 125C 4.0 7.2 A IOUTOC Output Over Current Shutdown TJ=-10C to 65C 4.4 5.5 6.6 A OCFILT Output Over Current Deglitch 25 uS

Final Datasheet Rev 1.0 October 22, 2015 www.semtech.com 7 of 10 Semtech Package Mechanical Drawings Units MILLIMETERS Dimension Limits MIN NOM MAX Number of Pins N 20 Pitch e 0.50 BSC Overall Height A 0.80 0.90 1.00 Standoff A1 0.00 0.02 0.05 Contact Thickness A3 0.20 REF Overall Length D 4.00 BSC Exposed Pad Width E2 2.55 2.70 2.80 Overall Width E 4.00 BSC Exposed Pad Length D2 2.55 2.70 2.80 Contact Width b 0.20 0.25 0.30 Contact Length L 0.30 0.40 0.50 Contact-to-Exposed Pad K 0.20 - - Notes: RR = Revision number YWW = Year Calendar Week

Final Datasheet Rev 1.0 October 22, 2015 www.semtech.com 8 of 10 Semtech Package Mechanical Drawings Units MILLIMETERS Dimension Limits MIN NOM MAX Contact Pitch E 0.50 BSC Optional Center Pad Width W2 - - 2.70 Optional Center Pad Length T2 - - 2.70 Contact Pad Spacing C1 - 4.00 - Contact Pad Spacing C2 - 4.00 - Contact Pad Width X20 X1 - - 0.35 Contact Pad Length X20 Y1 - - 0.35 Distance Between Pads G 0.15 - - Notes: Dimensions and tolerancing per ASME Y14.5M REF: Reference Dimension, usually without tolerance, for information only. BSC: Basic Dimension, Theorically exact value shown with tolerances.

Final Datasheet Rev 1.0 October 22, 2015 www.semtech.com 9 of 10 Semtech

Ordering Information

TS13101-QFNR Latching Galvanic Isolated Switch RoHS and Reach Compliance Triune Systems is fully committed to environmental quality. All Triune Systems materials and suppliers are fully compliant with RoHS (European Union Directive 2011/65/EU), REACH SVHC Chemical Restrictions (EC 1907/2006), IPC-1752 Level 3 materials declarations, and their subsequent amendments. Triune Systems maintains certified laboratory reports for all product materials, from all suppliers, which show full compliance to restrictions on the following:

  • Cadmium (Cd)
  • Chlorofluorocarbons (CFCs)
  • Chlorinate Hydrocarbons (CHCs)
  • Halons (Halogen free)
  • Hexavalent Chromium (CrVI)
  • Hydrobromofluorocarbons (HBFCs)
  • Hydrochlorofluorocarbons (HCFCs)
  • Lead (Pb)
  • Mercury (Hg)
  • Perfluorocarbons (PFCs)
  • Polybrominated biphenyls (PBB)
  • Polybrominated Diphenyl Ethers (PBDEs)

Final Datasheet Rev 1.0 October 22, 2015 10 of 10 Semtech Contact Information Semtech Corporation

200 Flynn Road, Camarillo, CA 93012

Phone: (805) 498-2111, Fax: (805) 498-3804 www.semtech.com IMPORTANT NOTICE Information relating to this product and the application or design described herein is believed to be reliable, however such information is provided as a guide only and Semtech assumes no liability for any errors in this document, or for the application or design described herein. Semtech reserves the right to make changes to the product or this document at any time without notice. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. Semtech warrants performance of its products to the specifications applicable at the time of sale, and all sales are made in accordance with Semtech’s standard terms and conditions of sale. SEMTECH PRODUCTS ARE NOT DESIGNED, INTENDED, AUTHORIZED OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT APPLICATIONS, DEVICES OR SYSTEMS, OR IN NUCLEAR APPLICATIONS IN WHICH THE FAILURE COULD BE REASONABLY EXPECTED TO RESUL T IN PERSONAL INJURY , LOSS OF LIFE OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. INCLUSION OF SEMTECH PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE UNDERTAKEN SOLELY AT THE CUSTOMER’S OWN RISK. Should a customer purchase or use Semtech products for any such unauthorized application, the customer shall indemnify and hold Semtech and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs damages and attorney fees which could arise. The Semtech name and logo are registered trademarks of the Semtech Corporation. All other trademarks and trade names mentioned may be marks and names of Semtech or their respective companies. Semtech reserves the right to make changes to, or discontinue any products described in this document without further notice. Semtech makes no warranty, representation or guarantee, express or implied, regarding the suitability of its products for any particular purpose. All rights reserved. © Semtech 2015