TS1052 TSC | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 8
Technical content
Features
- Constant Voltage and Constant Current Control
- Low Voltage Operation
- Precision Internal Voltage Reference
- Low External Component Count
- Current Sink Output Stage
- Easy Compensation
- Low AC Mains Voltage Rejection
Ordering Information
Part No. Package Packing TS1052CX6 RFG SOT-26 3Kpcs / 7” Reel Note: “G” denotes for Halogen free products Block Diagram Application
- Battery Charger
- Adapters Pin Function Description Name Type Function VCTRL Analog Input Input Pin of the Voltage Control Loop VND Power Supply Ground Line. 0V Reference For All Vol tage Out Current Sink Output Output Pin. Sinking Current Only ICTRL Analog Input Input Pin of the Current Control Loop VSENSE Analog Input Input Pin of the Current Control Loop VCC Power Supply Position Power Supply Line Pin Definition : 1. VCTRL 6. VCC 2. VND 5, VSENSE 3. Out 4. ICTRL
Constant Voltage and Constant Current Controller For Battery Chargers and Adaptors 2/8 Version: A12 Absolute Maximum Rating Parameter Symbol Value Unit DC Supply Voltage VCC 20 V Input Voltage VIN -0.3 to V CC V Operating Temperature TOP 0 to +85 oC Maximum Junction Temperature Range T J 150 oC Thermal Resistance Junction to Ambient R θja 250 oC/W Operating Condition Parameter Symbol Value Unit DC Supply Voltage VCC 2.5 to 18 V Electrical Specifications (TA=25 oC, VIN =5V unless otherwise noted) Note 1: If the Voltage on Vctrl (the negative input of the amplifier) is higher than the positive amplifier input (Vref- 1.21V), and it is increased by 1mV, the sinking current at the output will be increased by 3.5mA. Note 2: The internal Voltage reference is set at 1.21V (bandgap reference). The voltage control loop precision takes into account the cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans-conductance operational amplifier. The internal voltage reference is fixed by bandgap, and trimmed to 0.5% accuracy at room temperature. Note 3: When the positive input at Ictrl is lower than -200mV, and the voltage is decreased by 1mV, the sinking current at the output will be increased by 7mA Note 4: The internal current sense threshold is set to -200mV. The current control loop precision takes into account the cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans-conduction operational amplifier Parameter Symbol Min Typ Max Unit Total Current Consumption Total Supply Current – not taking the output sinking current into account ICC -- 1.1 2 mA Voltage Control Loop Trans-conduction Gain (Vctrl) sink Current Only (Note 1) G MW 1 3.5 -- mA/mV Voltage Control Loop Reference (Note 2) V REF 1.198 1.21 1.222 V Input Bias Current (Vctrl) IIBV -- 50 -- nA Current Control Loop Trans-conduction Gain (Ictrl) sink Current only (Note 3) G MI 1.5 7 -- mA/mV Current Control Loop Reference, (Note 4) IOUT =2.5A, V SENSE 196 200 204 mV Current Out of Pin Ictrl at – 200mV I IBI -- 25 -- µA Output Stage Low Output Voltage at 10mA sinking Current V OL -- 200 -- mV Output Short Circuit Current. Output to V CC. Sink Current Only IOS -- 27 50 mA
Constant Voltage and Constant Current Controller For Battery Chargers and Adaptors 3/8 Version: A12 Typical Adapter or Battery Charger Application Circuit * In the above application schematic, the TS1052 is used on the secondary side of a fly-back adapter (or battery charger) to provide an accurate control of voltage and current. The above feedback loop is made with an optocoupler. Principle of Operation and Application Hints Voltage Control The voltage loop is controlled via a first trans-conductance operational amplifier, the resistor bridge R1, R2, and the optocoupler which is directly connected to the output. The relation between the values of R1 & R2 should be chosen as following: *R1=R2 x Vref / (Vout-Vref) Where Vout is the desired output voltage. To Avoid the discharge of the load, the resistor bridge R1 & R2 should be highly resistive. For this type of application, a total value of 100K Ω (or more) would be appropriate for the resistors R1 & R2. As an example, with R2=100K Ω , Vout=4.10V, Vref=1.21V, then R1=41.9K Ω . Note that if the low drop diode should be inserted between the load and the voltage regulation resistor bridge to avoid current flowing from the load through the resistor bridge, this drop should be taken into account into the above calculations by replacing Vout by (Vout + Vdrop). TS1052
Constant Voltage and Constant Current Controller For Battery Chargers and Adaptors 4/8 Version: A12 Principle of Operation and Application Hints (continues) Current Control The current loop is controlled via the second trans-conductance operational amplifier, the sense resistor Rsense, and the optocoupler. The control verifies as following * Rsense x llim = Vsense * Rsense = Vsense / llim Ilim is the desired limited current, Vsense is the threshold voltage for the current control loop. As an example, with llim = 1A, Vsense = -200mV, then Rsense = 200m Ω . Note that the Rsense resistor should be chosen taking into account the maximum dissipation (Plim) through it during full load operation. * Plim = Vsense x llim As an example, with llim=1A, and Vsense=200mV, Plim=200mW. Therefore, for most adapter and battery charger applications, a quarter-watt, or half-watt resistor to make the current sensing function is sufficient. Vsense threshold is achieved internally by a resistor bridge tied to the Vref voltage reference. Its middle point is tied to the positive input of the current control operational amplifier, and its foot is to be connected to lower potential point of the senseresistor as shown on the following figure. The resistors of this bridge are matched to provide the best precision possible. The current siking outpits of the two trans-conductance operational amplifiers are common (to the outpit of the IC). This makes an Oring function which ensures that whenever the current or the voltage reaches too high values, the optocoupler is activated. The relation between the controlled current and the controlled output voltage can be described with a square characteristic as shown in the following V/I output-power graph Output Voltage vs. Output Current
Constant Voltage and Constant Current Controller For Battery Chargers and Adaptors 5/8 Version: A12 Principle of Operation and Application Hints (continues) Compensation The voltage control trans-conductance operational amplifier can be fully compensated. Both of its output and negative input are directly accessible for external compensation components. And example of a suitable compensation network is shown in typical application circuit. It consists of a capacitor Cvc1=2.2nF and a resistor Rcv1=470K Ω in series, connected in parallel with another capacitor Cvc2=22pF. The current control trans-conductance operational amplifier can be fully compensated. Both of its output and negative input are directly accessible for external compensation components. An example of suitable compensation network is shown in typical application circuit. It consists of a capacitor Cic1=2.2nF and resistor Ric1=22K Ω in series. When the Vcc voltage reaches 18V it could be interesting to limit the current coming through the output in the aim to reduce the dissipation of the device and increase the stability performances of the whole application. An example of suitable Rout value could be 330 Ω in series with the optocoupler in case Vcc=12V. Start Up and Short Circuit Conditions The TS1052 is not provided with a high enough supply voltage in under start-up or short-circuit conditions. This is due to the fact that the chip has its power supply line in common with the power supply line of the system. Therefore, the current limitation can only be ensured by the primary PWM module, which should be chosen accordingly. If the Primary current limitation is considered not to be precise enough for the application, then a sufficient supply for the TS1052 has to be ensured under any condition. It would then be necessary to add some circuitry to supply the chip with separate power line. This can be achieved in numerous ways, including an additional winding on the transformer. The following schematic shows how to realize a low-cost power supply for the TS1052 (with no additional windings). Please pay attention to the fact that in the particular case presented here, this low-cost power supply can reach voltages as high as twice the voltage of the regulated line. Since the absolute maximum rating of the TS1052 supply voltage is 18V, this low-cost auxiliary power supply can only be used in applications where the regulated line voltage does not exceed 9V. TS1052
Constant Voltage and Constant Current Controller For Battery Chargers and Adaptors 7/8 Version: A12 SOT-26 Mechanical Drawing Marking Diagram 52 = Device Code Y = Year Code M = Month Code for Halogen Free Product (O =Jan, P=Feb, Q =Mar, R =Apl, S=May, T=Jun, U =Jul, V=Aug, W =Sep, X=Oct, Y=Nov, Z=Dec) L = Lot Code SOT-26 DIMENSION DIM MILLIMETERS INCHES MIN TYP MAX MIN TYP MAX A 0.95 BSC 0.0374 BSC A1 1.9 BSC 0.0748 BSC F 0.00 -- 0.10 0.00 0.0039 J 5º -- 10º 5º -- 10º
Constant Voltage and Constant Current Controller For Battery Chargers and Adaptors 8/8 Version: A12 Notice Specifications of the products displayed herein are subject to change without notice. TSC or anyone on its behalf, assumes no responsibility or liability for any errors or inaccuracies. Information contained herein is intended to provide a product description only. No license, express or implied, to any intellectual property rights is granted by this document. Except as provided in TSC’s terms and conditions of sale for such products, TSC assumes no liability whatsoever, and disclaims any express or implied warranty, relating to sale and/or use of TSC products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright, or other intellectual property right. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications. Customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify TSC for any damages resulting from such improper use or sale.