cuidevices.com SERIES: TS04 │ DESCRIPTION: TACTILE SWITCH

FEATURES

  • surface mount
  • black actuator SPECIFICATIONS parameter conditions/description min typ max units rated voltage 1 12 Vdc rated current 0.01 50 mA withstanding voltage for 1 minute 250 Vac contact resistance applying load of 2 times operating force at 5 Vdc, 10 mA 100 mΩ insulation resistance at 100 Vdc for 1 minute 100 MΩ operating force see force table actuator travel 0.15 0.25 0.35 mm operating temperature -30 80 °C storage temperature -40 90 °C life rated load, 2 cycles/second, 1.5 times operating force 100 gf models 160 gf models 260 gf models 100,000 80,000 60,000 cycles cycles cycles vibration 10~55~10 Hz, 1.5 mm amplitude, 2 hours on each XYZ flammability rating see material table RoHS yes PART NUMBER KEY Base Number TS04 - 66 - XX - BK - XXX - SMT Actuator Height: 43 = 4.3 mm *73 = 7.3 mm 50 = 5.0 mm 75 = 7.5 mm 55 = 5.5 mm 85 = 8.5 mm 65 = 6.5 mm 95 = 9.5 mm 70 = 7.0 mm Push Force: 100 = 100 gf 160 = 160 gf 260 = 260 gf Note: *7.3 mm height versions have square actuator top. All other models have round actuator top. Additional Resources: Product Page | 3D Model | PCB Footprint

cuidevices.com CUI Devices │ SERIES: TS04 │ DESCRIPTION: TACTILE SWITCH date 11/03/2021│ page 2 of 5 MECHANICAL DRAWING (7.3 MM HEIGHT MODELS) units: mm tolerance: ±0.2 mm unless otherwise noted ITEM DESCRIPTION MATERIAL PLATING/COLOR 1 terminals brass silver 2 case PA66 (UL94HB) black 3 contacts stainless steel silver 4 cover stainless steel 5 stem PA66 (UL94HB) black Operting Force Table Model Press Force (N) Return Force (N) 100 1.0±0.3 >0.2 160 1.6±0.5 >0.2 260 2.6±0.5 >0.2 ACTUATOR POSITION ( ): MOMENTARY NORMAL DOWN OFF (ON) SCHEMATIC s s ႒ s s Recommended PCB Layout Top View Additional Resources: Product Page | 3D Model | PCB Footprint

cuidevices.com CUI Devices │ SERIES: TS04 │ DESCRIPTION: TACTILE SWITCH date 11/03/2021│ page 3 of 5 MECHANICAL DRAWING (ALL OTHER HEIGHT MODELS) units: mm tolerance: ±0.2 mm unless otherwise noted ITEM DESCRIPTION MATERIAL PLATING/COLOR 1 terminals brass silver 2 case PA66 (UL94HB) black 3 contacts stainless steel silver 4 cover stainless steel 5 stem PA66 (UL94HB) black Recommended PCB Layout Top View Operting Force Table Model Press Force (N) Return Force (N) 100 1.0±0.3 >0.2 160 1.6±0.5 >0.2 260 2.6±0.5 >0.2 ACTUATOR POSITION ( ): MOMENTARY NORMAL DOWN OFF (ON) SCHEMATIC Additional Resources: Product Page | 3D Model | PCB Footprint

cuidevices.com CUI Devices │ SERIES: TS04 │ DESCRIPTION: TACTILE SWITCH date 11/03/2021│ page 4 of 5 260ćmax.VecmD[ 230ć 180ć 150ć URRPWHPS SHDNWHPSHUDWXUH WLPH WLPHLQVLGHVROGHULQJHTXLSPHQW SUHKHDWLQJ SOLDERABILITY parameter conditions/description min typ max units hand soldering for maximum 3 seconds 350 °C reflow soldering1 see reflow profile 260 °C Notes: 1. Do not exceed 2 reflow cycles. PACKAGING A=160mmǃB=190mm C=160mmǃD=216mmǃE=48mm X=350mmǃY=455ǃZ=280mm units: mm Bag Size: 190 x 160 mm Carton Box Size: 445 x 350 x 280 mm Bag QTY: 1,000 pcs per bag Carton Box QTY: 60,000 pcs per carton Additional Resources: Product Page | 3D Model | PCB Footprint

CUI Devices │ SERIES: TS04 │ DESCRIPTION: TACTILE SWITCH date 11/03/2021│ page 5 of 5 cuidevices.com CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. rev. description date 1.0 initial release 09/20/2021 1.01 added 7.3 mm height model drawing 11/03/2021 The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY

Additional Resources: Product Page | 3D Model | PCB Footprint