DC/DC Medical Converter TRV 1M Series, 1 Watt

  • I/O isolation 5000 VAC (reinforced)
  • Short circuit protection
  • Semi-regulated outputs
  • Input voltage ranges (±10%): 5, 12, 15, 24 VDC
  • Operating temperature range -40 to +95 °C without derating
  • Certification according to IEC/EN/ES 60601-1 3rd edition for 2xMOPP and IEC/EN/UL 62368-1
  • Low leakage current < 2 μA
  • Efficiency up to 85%
  • Operation up to 5000 m altitude
  • 5-year product warranty IEC 60601-1 IEC 62368-1 ES 60601-1 UL 62368-1 The TRV 1M is a series of 1 Watt DC/DC converters in a compact SIP-9 pack- age with reinforced isolation of 5000 VAC for medical and industrial applica- tions. The series offers models with different input voltages (±10%) between 5 and 24 VDC. With a continuous short circuit protection and a low leakage cur- rent of less than 2 µA, this converter series is especially suited to protect any connected interfaces or applied parts to patients. Featuring semi-regulated out- puts this series provides a good level of regulation without affecting the cost ef- ficiency. It is an ideal solution for applications where a completely unregulated DC/DC converter would not meet you regulation requirements and therefore opens up the overall application range of this series. Together with an operat- ing temperature range from -40 to +95°C without derating and certifications according to IEC/EN/ES 60601-1 3rd ed. for 2xMOPP and IEC/EN/UL 62368-1 this series is suitable for many different applications where a medical isolation system and short circuit protection is needed. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TRV 1-0510M 4.5 - 5.5 VDC (5 VDC nom.)

3.3 VDC 303 mA 80 %

TRV 1-0511M 5 VDC 200 mA 82 % TRV 1-0512M 12 VDC 83 mA 85 % TRV 1-0513M 15 VDC 67 mA 84 % TRV 1-0521M +5 VDC 100 mA –5 VDC 100 mA 85 % TRV 1-0522M +12 VDC 42 mA –12 VDC 42 mA 85 % TRV 1-0523M +15 VDC 34 mA –15 VDC 34 mA 84 % TRV 1-1210M 9.6 - 14.4 VDC (12 VDC nom.) TRV 1-1211M 5 VDC 200 mA 82 % TRV 1-1212M 12 VDC 83 mA 84 % TRV 1-1213M 15 VDC 67 mA 83 % TRV 1-1221M +5 VDC 100 mA –5 VDC 100 mA 82 % TRV 1-1222M +12 VDC 42 mA –12 VDC 42 mA 83 % TRV 1-1223M +15 VDC 34 mA –15 VDC 34 mA 83 % TRV 1-1510M 12 - 18 VDC (15 VDC nom.)

3.3 VDC 303 mA 79 %

TRV 1-1511M 5 VDC 200 mA 83 % TRV 1-1512M 12 VDC 83 mA 84 % TRV 1-1513M 15 VDC 67 mA 84 % TRV 1-1521M +5 VDC 100 mA –5 VDC 100 mA 82 % TRV 1-1522M +12 VDC 42 mA –12 VDC 42 mA 83 % TRV 1-1523M +15 VDC 34 mA –15 VDC 34 mA 83 % TRV 1-2410M 19.2 - 28.8 VDC (24 VDC nom.)

3.3 VDC 303 mA 78 %

TRV 1-2411M 5 VDC 200 mA 82 % TRV 1-2412M 12 VDC 83 mA 83 % TRV 1-2413M 15 VDC 67 mA 83 % TRV 1-2421M +5 VDC 100 mA –5 VDC 100 mA 80 % TRV 1-2422M +12 VDC 42 mA –12 VDC 42 mA 81 % TRV 1-2423M +15 VDC 34 mA –15 VDC 34 mA 81 % Note - 5 Vin models: If the input will be switched electromechanically, use an external 100 μF/10 V E/C. to avoid voltage transient. www.tracopower.com November 30, 2022 Page 1 / 4

Input Current - At no load 5 Vin models: 30 mA typ. 12 Vin models: 30 mA typ. 15 Vin models: 15 mA typ. 24 Vin models: 10 mA typ. Surge Voltage 5 Vin models: 6 VDC max. (1 s max.) 12 Vin models: 25 VDC max. (1 s max.) 15 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 40 VDC max. (1 s max.) Recommended Input Fuse 5 Vin models: 500 mA (slow blow)

12 Vin models: 315 mA (slow blow)

15 Vin models: 315 mA (slow blow)

24 Vin models: 160 mA (slow blow)

(The need of an external fuse has to be assessed in the final application.) Input Specifications Voltage Set Accuracy ±3.5% max. (60% load: 3.3, 5, ±5 Vout models) ±3.5% max. (90% load: other models) Regulation - Input Variation (1% Vin step) single output models: 0.2% max. dual output models: 0.2% max. - Load Variation See application note: www.tracopower.com/overview/trv1m - Cross Regulation (25% / 100% asym. load) dual output models: 6% max. Ripple and Noise - 20 MHz Bandwidth 75 mVp-p typ. 100 mVp-p max. Capacitive Load - single output 3.3 Vout models: 2'000 µF max. 5 Vout models: 820 µF max. 12 Vout models: 470 µF max. 15 Vout models: 470 µF max. - dual output 5 / -5 Vout models: 470 / 470 µF max. 12 / -12 Vout models: 220 / 220 µF max. 15 / -15 Vout models: 220 / 220 µF max. Minimum Load Not required Temperature Coefficient ±0.03 %/K max. Short Circuit Protection Continuous, Automatic recovery Output Specifications Safety Standards - IT / Multimedia Equipment EN 62368-1 IEC 62368-1 UL 62368-1 - Medical Equipment EN 60601-1 IEC 60601-1 ANSI/AAMI ES 60601-1 2 x MOPP (Means Of Patient Protection) - Certification Documents www.tracopower.com/overview/trv1m Pollution Degree PD 2 Safety Specifications TRV 1M Series, 1 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 2 / 4

EMI Emissions EN 60601-1-2 edition 4 (Medical Devices) - Conducted Emissions EN 55011 class A (with external filter) EN 55011 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) - Radiated Emissions EN 55011 class A (with external filter) EN 55011 class B (with external filter) EN 55032 class A (with external filter) EN 55032 class B (with external filter) External filter proposal: www.tracopower.com/overview/trv1m EMS Immunity EN 55024 (IT Equipment) EN 60601-1-2 edition 4 (Medical Devices) - Electrostatic Discharge Air: EN 61000-4-2, ±15 kV, perf. criteria A Contact: EN 61000-4-2, ±8 kV, perf. criteria A - RF Electromagnetic Field EN 61000-4-3, 10 V/m, perf. criteria A - EFT (Burst) / Surge EN 61000-4-4, ±2 kV, perf. criteria A EN 61000-4-5, ±2 kV, perf. criteria A External filter proposal: www.tracopower.com/overview/trv1m - Conducted RF Disturbances EN 61000-4-6, 10 Vrms, perf. criteria A - PF Magnetic Field Continuous: EN 61000-4-8, 100 A/m, perf. criteria A 1 s: EN 61000-4-8, 1000 A/m, perf. criteria A EMC Specifications Relative Humidity 95% max. (non condensing) Temperature Ranges - Operating Temperature –40°C to +95°C (without derating) - Case Temperature +105°C max. - Storage Temperature –55°C to +125°C Cooling System Natural convection (20 LFM) Altitude During Operation 5'000 m max. Switching Frequency 220 - 380 kHz (PWM) Insulation System Reinforced Insulation Working Voltage (rated) 250 VAC Isolation Test Voltage - Input to Output, 60 s 5'000 VAC Creepage - Input to Output 8 mm min. Clearance - Input to Output 8 mm min. Isolation Resistance - Input to Output, 500 VDC 10'000 MΩ min. Isolation Capacitance - Input to Output, 100 kHz, 1 V 15 pF typ. 20 pF max. Leakage Current - Touch Current 2 µA max. Reliability - Calculated MTBF 19'360'000 h (MIL-HDBK-217F, ground benign) Washing Process Allowed (hermetical product) See Cleaning Guideline: www.tracopower.com/info/cleaning.pdf Environment - Vibration MIL-STD-810F - Mechanical Shock MIL-STD-810F - Thermal Shock MIL-STD-810F Housing Material Non-conductive Plastic (UL 94 V-0 rated) Potting Material Silicone (UL 94 V-0 rated) Pin Material Brass Pin Foundation Plating Nickel (1 - 2 µm) Pin Surface Plating Tin (3 - 5 µm), matte Housing Type Plastic Case Mounting Type PCB Mount Connection Type THD (Through-Hole Device) Footprint Type SIP9 General Specifications TRV 1M Series, 1 Watt All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated. www.tracopower.com November 30, 2022 Page 3 / 4

Weight 4.8 g Environmental Compliance - REACH Declaration www.tracopower.com/info/reach-declaration.pdf REACH SVHC list compliant REACH Annex XVII compliant - RoHS Declaration www.tracopower.com/info/rohs-declaration.pdf Exemptions: 7a, 7c-I (RoHS exemptions refer to the component concentration only, not to the overall concentration in the product (O5A rule). The SCIP number is provided on request.) Supporting Documents Overview Link (for additional Documents) www.tracopower.com/overview/trv1m Outline Dimensions TRV 1M Series, 1 Watt Bottom view 0.5x0.25 (0.02x0.01) 19.6 (0.77) 2.0 (0.079) 1.8 (0.07) 2.0 (0.079) 10.0 (0.394) 2.0 (0.079) 1 2 97 8 16.0 (0.63) 4.1 (0.16) 2.3 (0.09) 9.9 (0.39) 12.5 (0.49) Dimensions in mm (inch) Tolerances: x.x ±0.5 (±0.02) x.xx ±0.25 (±0.01) Pin diameter ±0.1 (±0.004) Pinout Pin Single Dual 1 +Vin (Vcc) +Vin (Vcc) 2 –Vin (GND) –Vin (GND) 7 –Vout –Vout

8 No Pin Common

© Copyright 2022 Traco Electronic AG Specification s can be changed without notice. www.tracopower.com Rev. November 30, 2022 Page 4 / 4