Features
Parameter Symbol Minimum Maximum Units Storage Temperature TST - 40 + 85 °C Operating Case Temperature1 Commercial Temp. TOP - 5 + 70 Extended Temp. - 5 + 85 Supply Voltage VCC 0 + 4.5 V Maximum Input Optical Power (30 seconds max.) Pin,max - + 3.0 dBm Input Voltage VIN 0 VCC V 1Measured on top side of SFP module at the front center vent hole of the cage. Extended Reach Multi-rate OC-48/STM-16 LR-2/L-16.2 SFP CWDM Transceivers with Digital Diagnostics
Oplink Communications, Inc 2012-01-09 21737-0976, Rev.02 TRPE48KE2 CWDM All parameters guaranteed only at typical data rate All parameters guaranteed only at typical data rate (Over Operating Case Temperature. VCC = 3.13 to 3.47V)Receiver Performance Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V)Transmitter Performance Characteristics Parameter Symbol Minimum Typical Maximum Units Operating Data Rate B 0.125 - 2.67 Gb/s Average Optical Output Power (50% duty cycle) PO 1.0 - + 5.0 dBm Extinction Ratio ER 8.2 - - dB Center Wavelength 1471 λC 1464.5 1471 1477.5 nm 1491 1484.5 1491 1497.5 1511 1504.5 1511 1517.5 1531 1524.5 1531 1537.5 1551 1544.5 1551 1557.5 1571 1564.5 1571 1577.5 1591 1584.5 1591 1597.5 1611 1604.5 1611 1617.5 Spectral Width (-20dB) Δλ20 - - 1.0 nm Side Mode Suppression Ratio SMSR 30.0 - - dB Optical Rise/Fall Time (20% to 80%) tr , tf - - 0.16 ns Relative Intensity Noise RIN -- - - 117 dB/Hz Jitter Generation JG - - 0.07 UIp-p Dispersion Penalty1 - -- - 2.5 dB Optical Output Eye Compliant with Telcordia GR-253-CORE and ITU-T Recommendation G.957 Parameter Symbol Minimum Typical Maximum Units Operating Data Rate1 B 0.125 - 2.67 Gb/s Receiver Sensitivity (10-10 BER)1 OC-3/12/48, 2.67Gb/s Pmin - 31.0 - - dBm Receiver Sensitivity (10 -12 BER)2 2.125Gb/s, 1.25Gb/s, 1.062Gb/s, 0.125Gb/s Pmin - 31.0 - - dBm Maximum Input Optical Power (10 -12 BER) Pmax - 8.0 - - dBm LOS Thresholds Increasing Light Input Plos+ - - - 31.0 dBm Decreasing Light Input Plos- - 45.0 - - LOS Timing Delay Increasing Light Input t_loss_off - - 100 μs Decreasing Light Input t_loss_on 2.3 - 100 LOS Hysteresis - 0.5 1.5 6.0 dB Wavelength of Operation λ 1260 - 1620 nm Receiver Reflectance - - - - 27.0 dB 1Measured with 223-1 PRBS. 2 Measured with 27-1 PRBS.
Oplink Communications, Inc Electrical Pad Layout Host Board Connector Pad Layout Toward Bezel Toward ASIC TX GND TD- (TX DATA IN-) TD+ (TX DATA IN+) TX GND VccTX VccRX RX GND RD+ (RX DATA OUT+) RD- (RX DATA OUT-) RX GND Top of Board TX GND TX Fault TX Disable MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) NO CONNECTION LOS RX GND RX GND Bottom of Board (as viewed thru top of board) 2012-01-09 21737-0976, Rev.02 TRPE48KE2 CWDM Transmitter Performance Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units Input Voltage Swing (TD+ & TD-) 1 VPP-DIF 0.35 - 1.75 V Input HIGH Voltage (TX Disable) 2 VIH 2.0 - VCC V Input LOW Voltage (TX Disable) 2 VIL 0 - 0.8 V Output HIGH Voltage (TX Fault) 3 VOH 2.0 - VCC + 0.3 V Output LOW Voltage (TX Fault) 3 VOL 0 - 0.8 V 1 Differential peak-to-peak voltage. 2 There is an internal 4.7 to 10kΩ pull-up resistor to VccT. 3 Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). Receiver Electrical Interface Electrical Power Supply Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V)) Parameter Symbol Minimum Typical Maximum Units Supply Voltage VCC 3.13 3.3 3.47 V Supply Current ICC - 210 350 mA Parameter Symbol Minimum Typical Maximum Units Output Voltage Swing (RD+ & RD-) 1 VPP-DIF 0.40 - 1.75 V Output HIGH Voltage (LOS) 2 VOH VCC - 1.3 - VCC + 0.3 V Output LOW Voltage (LOS) 2 VOL 0 - 0.5 V 1Differential peak-to-peak voltage across external 100Ω load. 2Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). (Over Operating Case Temperature. VCC = 3.13 to 3.47V)) Module Definition MOD_DEF(0) pin 6 MOD_DEF(1) pin 5 MOD_DEF(2) pin 4 Interpretation by Host TTL LOW SCL SDA Serial module definition protocol
Oplink Communications, Inc 2012-01-09 21737-0976, Rev.02 TRPE48KE2 CWDM Laser Safety: All transceivers are Class I Laser products per FDA/ CDRH and IEC-60825 standards. They must be operated under specified operating conditions. Laser Safety Oplink Communications, Inc. DATE OF MANUFACTURE: This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements Application Notes Electrical interface: All signal interfaces are compliant with the SFP MSA specification. The high speed DATA interface is differential AC-coupled internally with 1μF and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7 - 10kΩ resistor on the host board Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic HIGH when an insufficient photocurrent is produced. TX_Fault: The output indicates LOW when the transmitter is operating normally, and HIGH with a laser fault including laser end-of-life. TX Fault is an open collector/drain output that should be pulled up with a 4.7 - 10kΩ resistor on the host board. TX Fault in non-latching (automatically deasserts when fault goes away). TX_Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled (less than -45dBm). Serial Identification and Monitoring: The module definition of SFP is indicated by the three module definition pins, MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). Upon power up, MOD_DEF(1:2) appear as NC (no connection), and MOD_DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I 2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the SFP that are not write protected, and the negative edge clocks data from the SFP . The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The supported monitoring functions are temperature, voltage, bias current, transmitter power, average receiver signal, all alarms and warnings, and software monitoring of TX Fault/LOS. The device is internally calibrated. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFP MSA, and SFF-8472, Rev. 9.4 Power Supply and Grounding: The power supply line should be well-filtered. All 0.1μF power supply bypass capacitors should be as close to the transceiver module as possible. Example of SFP host board schematic TX DATA IN+ 1H coil or ferrite beadµ (<0.2 Ω series resistance) 0.1 TX DATA IN- TX Disable 0.1+ 0.1+ to 50 Ω load 3.3V RX DATA OUT+ RX DATA OUT- MOD_DEF(0) MOD_DEF(1) MOD_DEF(2) LOS to 50Ω load TX Fault Vcc 3.3V Vcc 50Ω line50Ω line 50Ω line 50Ω line RRRRR R: 4.7 to 10kΩ CAP Values in µF TRPE48KE2
Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Commu- nications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. © 2012, Oplink Communications, Inc. 46335 Landing Pkwy Fremont, CA 94538 T el: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com • www.oplink.com 2012-01-09 21737-0976, Rev.02 Mechanical Package
Ordering Information
1.49 ]950.[ 1.99 ]870.[ 10.45 [.411] 11.94 [.470] 8.46 [.333] 0.45 ]810.[ 0.60 ]420.[ 0.60 ]420.[ 13.62 [.536] 14.94 [.588] 45.00 [1.772] 13.80 [.543] 2.50 ]890.[ 6.54 [.257] 9.20 [.362] 41.80 [1.646] 6.25 [.246] 2.29 [.090] Dimensions in inches [mm] Defaultt olerances: Model Name Nominal Wavelength Latch Color32dB Link Budget (100km Distance)1 - 5°C to +70°C - 5°C to +85°C TRPE48KE2C00010 TRPE48KE2E00010 1471nm Gray TRPE48KE2C00020 TRPE48KE2E00020 1491nm Violet TRPE48KE2C00030 TRPE48KE2E00030 1511nm Blue TRPE48KE2C00040 TRPE48KE2E00040 1531nm Green TRPE48KE2C00050 TRPE48KE2E00050 1551nm Yellow TRPE48KE2C00060 TRPE48KE2E00060 1571nm Orange TRPE48KE2C00070 TRPE48KE2E00070 1591nm Red TRPE48KE2C00080 TRPE48KE2E00080 1611nm Brown 1The indicated transmission distance is for guidelines only, not guaranteed. The exact distance is dependent on the fiber loss, connector and splice loss, and allocated system penalty. Longer distances can be supported if the optical link power budget is satisfied. TRPE48KE2 CWDM