TRPE48CS1C000E2 OPLINK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

Parameter Symbol Minimum Maximum Units Storage Temperature TST - 40 + 85 °C Operating Case Temperature1 “COM” TOP - 5 + 70 °C“EXT” - 5 + 85 “IND” - 40 + 85 Supply Voltage VCC 0 + 5.0 V Maximum Input Optical Power (30 seconds max.) Pin,max - + 3.0 dBm Input Voltage VIN 0 VCC V 1Measured on top side of SFP module at the front center vent hole of the cage. Absolute Maximum Ratings 21737-0971, Rev.B 2009-03-31 Mul ti-rate OC-48/STM-16 SFP Transceivers with Digital Diagnostics

Oplink Communications, Inc. Transmitter Performance Characteristics TRPE48-E2 Single Mode Multi-rate (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units Operating Data Rate B 0.125 - 2.67 Gb/s Average Optical Output Power (coupled into single mode fiber), 50% duty cycle SR-1 PO - 8.0 - - 3.0 dBmIR-1, IR-2 - 5.0 - 0 Extinction Ratio Phi /Plo 8.2 - - dB Center Wavelength SR-1, IR-1 λC 1266 1310 1360 nm IR-2 1430 1550 1580 LR-1 1280 1310 1335 LR-2 1500 1550 1580 Spectral Width (RMS) SR-1 ΔλRMS - - 2.4 nm Spectral Width (-20dB) IR-1, IR-2, LR-1, LR-2 Δλ20 - - 1.0 nm Side Mode Suppression RatioIR-1, IR-2, LR-1, LR-2 SMSR 30 - - dB Optical Rise/Fall Time (20% to 80%) tr , tf - - 0.16 ns Relative Intensity Noise RIN -- - - 117 dB/Hz Jitter Generation OC-48 JG - - 0.07 UIp-p Dispersion Penalty IR-1, IR-2, LR-1, -- - 1.0 dB LR-22 -- - 2.0 Optical Output Eye Compliant with Telcordia GR-253-CORE and ITU-T Recommendation G.957 1Except for LR-2 which is 8.2dB minimum. 2Specified at 1600ps/nm dispersion, which corresponds to the approximate worst-case dispersion for 80km G.652/G.654 fiber over the wavelength range of 1500-1580nm Receiver Performance Characteristics Parameter Symbol Minimum Typical Maximum Units Operating Data Rate1 B 0.125 - 2.67 Gb/s Receiver Sensitivity (10-10 BER)1 2.67Gb/s, OC-48 SR-1, IR-1, IR-2 Pmin - 19.0 - - dBmLR-1, LR-22 - 28.0 - - OC-3/12 - 23.0 - - Receiver Sensitivity (10-12 BER)3 2.125Gb/s, 1.25Gb/s, 1.062Gb/s Pmin - 20.0 - - dBm Maximum Input Optical Power (10 -12 BER) SR-1 Pmax - 3.0 - - dBmIR-1, IR-2 0 - - LOS Thresholds SR-1, IR-1, IR-2 Increasing Light Input Plos+ - - - 23.0 dBm Decreasing Light Input Plos- - 35.0 - - LR-1, LR-2 Increasing Light Input Plos+ - - - 28.0 Decreasing Light Input Plos- - 42.0 - - LOS Timing Delay Increasing Light Input t_loss_off - - 100 μs Decreasing Light Input t_loss_on 2.3 - 100 LOS Hysteresis - 0.54 - - dB Wavelength of Operation λ 1260 - 1600 nm Receiver Reflectance - - - - 27.0 dB 1Measured with 223-1 PRBS. 3Measured with 27-1 PRBS. 4For OC-3, Minimum Hysteresis is 0.2dB. (Over Operating Case Temperature. VCC = 3.13 to 3.47V) 2 21737-0971, Rev.B 2009-03-31

Oplink Communications, Inc. Electrical Pad Layout Host Board Connector Pad Layout Toward Bezel Toward ASIC TX GND TD- (TX DATA IN-) TD+ (TX DATA IN+) TX GND VccTX VccRX RX GND RD+ (RX DATA OUT+) RD- (RX DATA OUT-) RX GND Top of Board TX GND TX Fault TX Disable MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) NO CONNECTION LOS RX GND RX GND Bottom of Board (as viewed thru top of board) Transmitter Performance Characteristics TRPE48-E2 Single Mode Multi-rate (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units Input Voltage Swing (TD+ & TD-)1 VPP-DIF 0.35 - 1.75 V Input HIGH Voltage (TX Disable)2 VIH 2.0 - VCC V Input LOW Voltage (TX Disable)2 VIL 0 - 0.8 V Output HIGH Voltage (TX Fault)3 VOH 2.0 - VCC + 0.3 V Output LOW Voltage (TX Fault)3 VOL 0 - 0.8 V 1Differential peak-to-peak voltage. 2There is an internal 4.7 to 10kΩ pull-up resistor to VccT. 3Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). Receiver Electrical Interface Electrical Power Supply Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units Supply Voltage VCC 3.13 3.3 3.47 V Supply Current SR-1, IR-1, IR-2 ICC - 175 300 mA LR-1, LR-2 - 175 320 Parameter Symbol Minimum Typical Maximum Units Output Voltage Swing (RD+ & RD-)1 VPP-DIF 0.60 - 1.75 V Output HIGH Voltage (LOS)2 VOH VCC - 1.3 - VCC + 0.3 V Output LOW Voltage (LOS)2 VOL 0 - 0.5 V 1Differential peak-to-peak voltage across external 100Ω load. 2Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Module Definition MOD_DEF(0) pin 6 MOD_DEF(1) pin 5 MOD_DEF(2) pin 4 Interpretation by Host TTL LOW SCL SDA Serial module definition protocol 21737-0971, Rev.B 2009-03-31

Oplink Communications, Inc. Application Notes Electrical interface: All signal interfaces are compliant with the SFP MSA specification. The high speed DATA interface is differential AC-coupled internally with 1μF and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7 - 10kΩ resistor on the host board Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic HIGH when an insufficient photocurrent is produced. TX_Fault: The output indicates LOW when the transmitter is operating normally, and HIGH with a laser fault including laser end-of-life. TX Fault is an open collector/drain output and should be pulled up with a 4.7 - 10kΩ resistor on the host board. TX Fault is non-latching (automatically deasserts when fault goes away). TX_Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled (less than -45dBm). Serial Identification and Monitoring: The module definition of SFP is indicated by the three module definition pins, MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). Upon power up, MOD_DEF(1:2) appear as NC (no connection), and MOD_DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the SFP that are not write protected, and the negative edge clocks data from the SFP . The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the startand end of serial protocol activation. The supported monitoring functions are internal temperature, supply voltage, bias current, transmitter power, average receiver signal, all alarms and warnings and software monitoring of TX Fault/LOS. The device is internally calibrated. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFP MSA, and SFF-8472, Rev. 9.4. Power supply and grounding: The power supply line should be well-filtered. All 0.1μF power supply bypass capacitors should be as close to the transceiver module as possible. Example of SFP host board schematic Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 stan- dards. They must be operated under specified operating conditions. Oplink Communications, Inc. DATE OF MANUFACTURE: MANUFACTURED IN THE USA This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements TX DATA IN+

1 H coil or ferrite bead

(<0.2 series resistance) 0.1 TX DATA IN- TX Disable 0.1+ 50 line 0.1+ to 50 load Vcc 3.3V RX DATA OUT+ 13

12 RX DATA OUT-

6 MOD_DEF(0)

MOD_DEF(1) MOD_DEF(2) LOS to 50 load R

2 TX Fault

3.3V 50 line 50 line 50 line R TRPE48-E2 Single Mode Multi-rate TRPE48-E2 R: 4.7 to 10kΩ CAP Values in μF 21737-0971, Rev.B 2009-03-31

Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Com- munications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringe- ments of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. © 2009, Oplink Communications, Inc. 46335 Landing Pkwy Fremont, CA 94538 T el: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com • www.oplink.com

Ordering Information

1.49 [.059] 1.99 [.078]10.45 [.411] 11.94 [.470] 8.46 [.333] 0.45 [.018] 0.60 [.024] 0.60 [.024] 13.62 [.536] 14.94 [.588] 45.00 [1.772] 13.80 [.543] 2.50 [.098] 6.54 [.257] 9.20 [.362] 41.80 [1.646] 6.25 [.246] 2.29 [.090] Package Outline Dimensions in inches [mm] Default tolerances: TRPE48E2 Single Mode Multi-rate Part Number Operating Temperature Latch Color Nominal Wavelength SONET/SDH Standards Distance1 TRPE48CS1C000E2 - 5°C to +70°C Gray 1310nm FP SR-1/I-16 12/2km TRPE48EI1C000E2 - 5°C to +70°C Violet 1310nm DFB IR-1/S-16.1 21/15km TRPE48EI2C000E2 - 5°C to +70°C Red 1550nm DFB IR-2/S-16.2 42/15km TRPE48HL1C000E2 - 5°C to +70°C Red 1310nm DFB LR-1/L-16.1 40km TRPE48HL2C000E2 - 5°C to +70°C White 1550nm DFB LR-2/L-16.2 80km TRPE48CS1E000E2 - 5°C to +85°C Gray 1310nm FP SR-1/I-16 12/2km TRPE48EI1E000E2 - 5°C to +85°C Yellow 1310nm DFB IR-1/S-16.1 21/15km TRPE48EI2E000E2 - 5°C to +85°C Red 1550nm DFB IR-2/S-16.2 42/15km TRPE48HL1E000E2 - 5°C to +85°C Red 1310nm DFB LR-1/L-16.1 40km TRPE48HL2E000E2 - 5°C to +85°C White 1550nm DFB LR-2/L-16.2 80km TRPE48CS1I000E2 - 40°C to +85°C Gray 1310nm FP SR-1/I-16 12/2km TRPE48EI1I000E2 - 40°C to +85°C Yellow 1310nm DFB IR-1/S-16.1 21/15km TRPE48EI2I000E2 - 40°C to +85°C Red 1550nm DFB IR-2/S-16.2 42/15km TRPE48HL1I000E2 - 40°C to +85°C Red 1310nm DFB LR-1/L-16.1 40km TRPE48HL2I000E2 - 40°C to +85°C White 1550nm DFB LR-2/L-16.2 80km 1These are target distances to be used for classification and not for specification, per Telcordia GR-253-CORE/ITU-T Recommendation G.957. 21737-0971, Rev.B 2009-03-31