DATASHEET SEARCH SITE | WWW.ALLDATASHEET.COM
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 5
Technical content
Features
S0210. Rev02. (web) 2012.06.22 Absolute Maximum Ratings Parameter Symbol Minimum Maximum Units Storage Temperature TST - 40 + 85 °C Operating Case Temperature 1 Commercial TOP - 5 + 70 Extended - 5 + 85 Supply Voltage VCC 0 + 5.0 V Input Voltage VIN 0 VCC V 1 Measured on top side of SFP module at the front center vent hole of the cage. Eight (8) Wavelength CWDM Transceivers Lead Free Design & Fully RoHS Compliant Compatible with SFP MSA Compatible with SONET/SDH OC-3/STM-1 (155Mb/s) LR-2/L-1.2 Long Reach Specifications Digital Diagnostics through Serial Interface Internal Calibration for Digital Diagnostics Optical Link Power Budgets of 32dB & 34dB Minimum Eye Safe (Class I Laser Safety) Duplex LC Optical Interface Loss of Signal Output & TX Disable Input Hot-pluggable TX Fault & Loss of Signal Outputs TX Disable Input Pb
Oplink Communications, Inc S0210. Rev02. (web) 2012.06.222 TRPE03-G CWDM Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions. Oplink Communications, Inc. This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements Transmitter Performance Characteristics Receiver Performance Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Parameter Symbol Minimum Typical Maximum Units Operating Data Rate 1 B - 156 - Mb/s Average Optical Output Power (coupled into single mode fiber), 50% duty cycle TRPE03HL2xG PO - 2.0 - + 3.0 dBm TRPE03KL2xG 0 - + 5.0 Extinction Ratio ER 10 - - dB Center Wavelength 1471 λC 1464.5 1471 1477.5 nm 1491 1484.5 1491 1497.5 1511 1504.5 1511 1517.5 1531 1524.5 1531 1537.5 1551 1544.5 1551 1557.5 1571 1564.5 1571 1577.5 1591 1584.5 1591 1597.5 1611 1604.5 1611 1617.5 Spectral Width (-20dB) Δλ20 - - 1.0 nm Side Mode Suppression Ratio SMSR 30 - - dB Optical Output Eye Compliant with Telcordia GR-253-CORE and ITU-T Recommendation G.957 1 Specified through EOL. Parameter Symbol Minimum Typical Maximum Units Operating Data Rate 1 B - 156 - Mb/s Receiver Sensitivity (10 -10 BER) 2 Pmin - 34.0 - 37.0 - dBm Maximum Input Optical Power (10-12 BER) 2 Pmax 0 - - dBm LOS Thresholds Increasing Light Input Plos+ - - - 34.0 dBm Decreasing Light Input Plos- - 45.0 - - LOS Timing Delay Increasing Light Input t_loss_off - - 100 µs Decreasing Light Input t_loss_on 2.3 - 100 LOS Hysteresis - 1.0 - - dB Wavelength of Operation λ 1100 - 1620 nm Receiver Reflectance - - - - 25.0 dB 1 Data rate ranges from 50Mb/s to 266Mb/s. However, some degradation may be incurred in overall performance. 2 Measured with 223-1 PRBS at 156Mb/s. (Over Operating Case Temperature. VCC = 3.13 to 3.47V)
Oplink Communications, Inc 3 S0210. Rev02. (web) 2012.06.22 TRPE03-G CWDM Electrical Pad Layout Host Board Connector Pad Layout Transmitter Performance Characteristics Toward Bezel Toward ASIC TX GND TD- (TX DATA IN-) TD+ (TX DATA IN+) TX GND VccTX VccRX RX GND RD+ (RX DATA OUT+) RD- (RX DATA OUT-) RX GND Top of Board TX GND TX Fault TX Disable MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) NO CONNECTION LOS RX GND RX GND Bottom of Board (as viewed thru top of board) (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Receiver Electrical Interface Electrical Power Supply Characteristics (Over Operating Case Temperature. VCC = 3.13 to 3.47V) (Over Operating Case Temperature. VCC = 3.13 to 3.47V) Module Definition Parameter Symbol Minimum Typical Maximum Units Input Voltage Swing (TD+ & TD-) 1 VPP-DIF 0.25 - 2.4 V Input HIGH Voltage (TX Disable) 2 VIH 2.0 - VCC V Input LOW Voltage (TX Disable) 2 VIL 0 - 0.8 V Output HIGH Voltage (TX Fault) 3 VOH 2.0 - VCC + 0.3 V Output LOW Voltage (TX Fault) 3 VOL 0 - 0.8 V 1 Differential peak-to-peak voltage. 2 There is an internal 4.7 to 10kΩ pull-up resistor to VccT. 3 Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). Parameter Symbol Minimum Typical Maximum Units Power Supply Voltage VCC 3.13 3.3 3.47 V Supply Current ICC - 235 285 mA Parameter Symbol Minimum Typical Maximum Units Output Voltage Swing (RD+ & RD-) 1 VPP-DIF 0.6 - 2.0 V Output HIGH Voltage (LOS) 2 VOH 2.0 - VCC + 0.3 V Output LOW Voltage (LOS) 2 VOL 0 - 0.5 V 1 Differential peak-to-peak voltage across external 100Ω load. 2 Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). MOD_DEF(0) pin 6 MOD_DEF(1) pin 5 MOD_DEF(2) pin 4 Interpretation by Host TTL LOW SCL SDA Serial module definition protocol
Oplink Communications, Inc 4 S0210. Rev02. (web) 2012.06.22 TRPE03-G CWDM Application Notes Example of SFP Host Board Schematic Electrical interface: All signal interfaces are compliant with the SFP MSA specification. The high speed DATA interface is differential AC-coupled internally with 1μF and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7 - 10kΩ resistor on the host board Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates logic HIGH when an insufficient photocurrent is produced. TX_Fault: The output indicates LOW when the transmitter is operating normally and HIGH with a laser fault including laser end-of-life. TX Fault is an open collector/drain output that should be pulled up with a 4.7 - 10kΩ resistor on the host board. TX Fault is latched per SFP MSA. TX_Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled (less than -45dBm). Serial Identification and Monitoring: The module definition of SFP is indicated by the three module definition pins, MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). Upon power up, MOD_DEF(1:2) appear as NC (no connection), and MOD_DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the SFP that are not write protected, and the negative edge clocks data from the SFP . The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The supported monitoring functions are internal temperature, supply voltage, bias current, transmitter power, average receiver signal, all alarms and warnings and software monitoring of TX Fault/LOS. The device is internally calibrated. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFPMSA, and SFF-8472, Rev. 9.4 Power supply and grounding: The power supply line should be well-filtered. All 0.1μF power supply bypass capacitors should be as close to the transceiver module as possible. R: 4.7 to 10kΩ CAP Values in μF TX DATA IN+ 1H coil or ferrite beadµ (<0.2 Ω series resistance) 0.1 TX DATA IN- TX Disable 0.1+ 0.1+ to 50 Ω load 3.3V RX DATA OUT+ RX DATA OUT- MOD_DEF(0) MOD_DEF(1) MOD_DEF(2) LOS to 50Ω load TX Fault Vcc 3.3V Vcc 50Ω line50Ω line 50Ω line 50Ω line RRRRR SFP
46335 Landing Pkwy Fremont, CA 94538 T el: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com • www.oplink.com Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Commu- nications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. © 2012, Oplink Communications, Inc. 5 S0210. Rev02. (web) 2012.06.22 TRPE03-G CWDM Package Outline 1.49 ]950.[ 1.99 ]870.[ 10.45 [.411] 11.94 [.470] 8.46 [.333] 0.45 ]810.[ 0.60 ]420.[ 0.60 ]420.[ 13.62 [.536] 14.94 [.588] 45.00 [1.772] 13.80 [.543] 2.50 ]890.[ 6.54 [.257] 9.20 [.362] 41.80 [1.646] 6.25 [.246] 2.29 [.090] Dimensions in inches [mm] Default tolerances:
Ordering Information
(nm) Latch Color32dB Link Budget (100/80km Distance)1 34dB Link Budget (100/80km Distance)1 TRPE03HL2C00010G TRPE03KL2C00010G - 5°C to +70°C Commercial 1471 Gray TRPE03HL2C00020G TRPE03KL2C00020G - 5°C to +70°C Commercial 1491 Violet TRPE03HL2C00030G TRPE03KL2C00030G - 5°C to +70°C Commercial 1511 Blue TRPE03HL2C00040G TRPE03KL2C00040G - 5°C to +70°C Commercial 1531 Green TRPE03HL2C00050G TRPE03KL2C00050G - 5°C to +70°C Commercial 1551 Yellow TRPE03HL2C00060G TRPE03KL2C00060G - 5°C to +70°C Commercial 1571 Orange TRPE03HL2C00070G TRPE03KL2C00070G - 5°C to +70°C Commercial 1591 Red TRPE03HL2C00080G TRPE03KL2C00080G - 5°C to +70°C Commercial 1611 Brown TRPE03HL2E00010G TRPE03KL2E00010G - 5°C to +85°C Extended 1471 Gray TRPE03HL2E00020G TRPE03KL2E00020G - 5°C to +85°C Extended 1491 Violet TRPE03HL2E00030G TRPE03KL2E00030G - 5°C to +85°C Extended 1511 Blue TRPE03HL2E00040G TRPE03KL2E00040G - 5°C to +85°C Extended 1531 Green TRPE03HL2E00050G TRPE03KL2E00050G - 5°C to +85°C Extended 1551 Yellow TRPE03HL2E00060G TRPE03KL2E00060G - 5°C to +85°C Extended 1571 Orange TRPE03HL2E00070G TRPE03KL2E00070G - 5°C to +85°C Extended 1591 Red TRPE03HL2E00080G TRPE03KL2E00080G - 5°C to +85°C Extended 1611 Brown 1 The indicated transmission distance is for guidelines only, not guaranteed per Telcordia GR-253-CORE/ITU-T Recommendation G.957. Longer distances can be supported if the optical link power budget is satisfied.