Parameter Symbol Minimum Maximum Units Storage Temperature Tst - 40 + 85 !C Operating Case Temperature1 ªCOMº Top - 5 + 70 ªINDº - 40 + 85 Supply Voltage Vcc 0 + 5.0 V Input Voltage Vin 0 Vcc V 1Measured on top side of SFP module at the front center vent hole of the cage. Absolute Maximum Ratings OC-3/STM-1 SFP Transceivers with Digital Diagnostics TRPE03-E1 Single Mode The TRPE03-E1 SFP series of fiber optic transceivers w ith integrated digital diagnostics monitoring functionality provide a quick and reliable interface for short reach (SR), intermediate reach (IR) and long reach (LR) applications. The diagnostic functions, alarm and w arning features as described in the Multi-Source Agreement (MSA) document, SFF-8472 (Rev. 9.4), are provided via an I2C serial interface. Available products under this series are compliant w ith applicable SONET/ SDH standards for OC-3/STM-1. A ll modules satisfy Class I Laser Safety requirements in accordance w ith the U .S. FDA /CDRH and international IEC-60825 standards. The TRPE03-E1 transceivers connect to standard 20-pad SFP connectors for hot plug capability. This allow s the system designer to make configuration changes or maintenance by simply plugging in different types of transceivers w ithout removing the pow er supply from the host system. The transceivers have colored bail-type latches, w hich offer an easy and convenient w ay to release the modules. The latch is compliant w ith the SFP MSA . The transmitter design incorporates a highly reliable 1310nm or 1550nm InG aA sP laser and a driver circuit. The receiver features a transimpedance amplifier IC optimized for high sensitivity and w ide dynamic range. The transmitter and receiver DATA interfaces are AC-coupled internally. LVTTL Transmitter Disable control input and Loss of Signal output interfaces are also provided. The transceivers operate from a single +3.3V pow er supply over tw o operating case temperature ranges of -5!C to +70!C (COM), or -40!C to +85!C (IND). The housing is made of metal for EMI immunity. Produc t D esc rip tion þ Compatible w ith SFP MSA þ Compliant w ith SONET/SDH OC-3/STM-1 (155Mb/s) þ SONET/SDH Reaches (SR-1, IR-1, LR-1 & LR-2) þ Digital Diagnostics through Serial Interface þ Internal Calibration for Digital Diagnostics þ Eye Safe (Class I Laser Safety) þ Duplex LC Optical Interface þ -40!C to +85!C Operating Case Temperature Option þ Excellent EMI & ESD Protection þ H ot-pluggable þ TX Fault & Loss of Signal Outputs þ TX Disable Input þ Single +3.3V Pow er Supply Fea tures 21737-0969, Rev.A 2008-11-11

Oplink Communications, Inc. Transmitter Performance C haracteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) TR PE03-E1 Single Mode All parameters guaranteed only at typical data rate Parameter Symbol Minimum Typical Maximum Units Operating Data Rate1 B - 156 - Mb/s Average Optical Output Pow er (coupled into single mode " ber), 50% duty cycle IR-1 PO dBm Extinction Ratio Phi/Plo 10 - - dB Center W avelength IR-1 c 1261 1310 1360 nmLR-1 1270 1310 1360 LR-2 1480 1550 1580 Spectral W idth (RMS) IR-1 & LR-1 ! RMS - - 3 nm Spectral W idth (-20dB) LR-2 ! 20 - - 1 nm Side Mode Suppression Ratio LR-2 SMSR 30 - - dB Optical Output Eye Compliant w ith Telcordia G R-253-CORE and ITU -T Recommendation G .957 1Data rate ranges from 50Mb/s to 266Mb/s. H ow ever, some degradation may be incurred in overall performance. Receiver Performance C haracteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) All parameters guaranteed only at typical data rate Parameter Symbol Minimum Typical Maximum Units Operating Data Rate1 B - 156 - Mb/s Receiver Sensitivity (10-10 BER)2 Pmin - 34.0 - 36.0 - dBm Maximum Input Optical Pow er (10-10 BER)2 Pmax - 7.0 0 - dBm LOS Thresholds Increasing Light Input Plos+ - - - 34.0 dBm Decreasing Light Input Plos- - 45.0 - - LOS Timing Delay Increasing Light Input t_loss_o"# - - 100 Decreasing Light Input t_loss_on 2.3 - 100 LOS H ysteresis - 0.5 1.5 - dB W avelength of Operation 1100 - 1600 nm Receiver Re$ ectance (LR-2 only) - - - - 25.0 dB 1Data rate ranges from 50Mb/s to 266Mb/s. H ow ever, some degradation may be incurred in overall performance. 2Specified in average optical input pow er and measured w ith 223-1 PRBS at 156Mb/s and 1310nm for IR-1& LR-1, and 1550nm for LR-2. Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 standards. They m ust be operated under speci! ed operating conditions. Oplink Communications, Inc. DATE OF MA NU FACTU RE: This product complies w ith 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements Laser Safety 21737-0969, Rev.A 2008-11-11

Oplink Communications, Inc. Electrical Pad Layout H ost Board C onnector Pad Layout Tow ard Bezel Tow ard ASIC TX G ND TD- (TX DATA IN-) TD+ (TX DATA IN+) TX G ND VccTX VccRX RX G ND RD+ (RX DATA OU T+) RD- (RX DATA OU T-) RX G ND TX G ND TX Fault TX Disable MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) NO CONNECTION LOS RX G ND RX G ND Bottom of Board (as viewed thru top of board)Top of Board TR PE03-E1 Single Mode Parameter Symbol Minimum Typical Maximum Units Input Voltage Sw ing (TD+ & TD-)1 VPP-DIF 0.35 - 2.4 V Input H IG H Voltage (TX Disable)2 VIH 2.0 - VCC V Input LOW Voltage (TX Disable)2 VIL 0 - 0.8 V Output H IG H Voltage (TX Fault)3 VOH 2.0 - VCC#+ 0.3 V Output LOW Voltage (TX Fault)3 VOL 0 - 0.8 V 1Di' erential peak-to-peak voltage. 2There is an internal 4.7 to 10k* pull-up resistor to VccT. 3Open collector compatible, 4.7 to 10k* pull-up resistor to Vcc (H ost Supply Voltage). Parameter Symbol Minimum Typical Maximum Units Output Voltage Sw ing (RD+ & RD-)1 VPP-DIF 0.6 - 2.0 V Output H IG H Voltage (LOS)2 VOH 2.0 - VCC#+ 0.3 V Output LOW Voltage (LOS)2 VOL 0 - 0.5 V 1Di' erential peak-to-peak voltage across external 100* load. 2Open collector compatible, 4.7 to 10k* pull-up resistor to Vcc (H ost Supply Voltage). Parameter Symbol Minimum Typical Maximum Units Supply Voltage VCC 3.13 3.3 3.47 V Supply Current OC-3 (IR-1, LR-1) ICC - 190 220 mA MO D _D EF(0) pin 6 MO D _D EF(1) pin 5 MO D _D EF(2) pin 4 Interpretation by H ost TTL LOW SCL SDA Serial module definition protocol Transmitter Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Receiver Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Electrical Pow er Supply C haracteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Module D efinition 21737-0969, Rev.A 2008-11-11

Oplink Communications, Inc. 21737-0969, Rev.A 2008-11-11 Example of SFP host board schematic TR PE03-E1 Single Mode Application N otes Electrical Interface: A ll signal interfaces are compliant w ith the SFP MSA specification. The high speed DATA interface is differential AC-coupled internally w ith 1;F and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up w ith a 4.7 - 10k* resistor on the host board. Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic H IG H w hen an insufficient photocurrent is produced. TX Fault: The output indicates LOW w hen the transmitter is operating normally, and H IG H w ith a laser fault including laser end-of-life. TX Fault is an open collector/drain output and should be pulled up w ith a 4.7 - 10k* resistor on the host board. TX Fault is non-latching (automatically deasserts w hen fault goes aw ay). TX Disable: W hen the TX Disable pin is at logic H IG H , the transmitter optical output is disabled (less than -45dBm). Serial Identification and Monitoring: The module definition of SFP is indicated by the three module definition pins, MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). U pon pow er up, MOD_DEF(1:2) appear as NC (no connection), and MOD_DEF(0) is TTL LOW . W hen the host system detects this condition, it activates the serial protocol (standard tw o-w ire I2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the SFP that are not w rite protected, and the negative edge clocks data from the SFP. The serial data signal (SDA ) is for serial data transfer. The host uses SDA in conjunction w ith SCL to mark the start and end of serial protocol activation. The supported monitoring functions are temperature, voltage, bias current, transmitter pow er, average receiver signal, all alarms and w arnings, and softw are monitoring of TX Fault/LOS. The device is internally calibrated. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFP MSA, and SFF-8472, Rev. 9.4. Power Supply and Grounding: The pow er supply line should be w ell-filtered. A ll 0.1;F pow er supply bypass capacitors should be as close to the transceiver module as possible. R: 4.7 to 10k* CA P Values in mF TRPE03-E1 TX DATA IN+

1 H coil or ferrite beadm

(<0.2 series resistance)W 0.1 TX DATA IN- TX Disable 0.1+ 50 lineW 0.1+ to 50 loadW Vcc 3.3V RX DATA OUT+ 13

12 RX DATA OUT-

6 MOD_DEF(0)

MOD_DEF(1) MOD_DEF(2) LOS to 50 loadW R

2 TX Fault

3.3V 50 lineW 50 lineW 50 lineW R

46335 Landing Pkwy Fremont, CA 94538 Tel: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com • www.oplink.com Oplink Communications, Inc. reserves the right to make changes in equipment design or speci" cations w ithout notice. Information supplied by Oplink Commu- nications, Inc. is believed to be accurate and reliable. H ow ever, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, w hich may result from its use. No license is granted by implication or otherw ise under any patent right of Oplink Communications, Inc. < 2008, Oplink Communications, Inc. 1.49 [.059] 1.99 [.078] 10.45 [.411] 11.94 [.470] 8.46 [.333] 0.45 [.018] 0.60 [.024] 0.60 [.024] 13.62 [.536] 14.94 [.588] 45.00 [1.772] 13.80 [.543] 2.50 [.098] 6.54 [.257] 9.20 [.362] 41.80 [1.646] 6.25 [.246] 2.29 [.090] O rdering Information Package O utline TR PE03-E1 Single Mode Dimensions in inches [mm] Default tolerances: .xxx = > .005º, .xx = > .01º Part N umber O perating Tem- perature Latch C olor N ominal W avelength SO N ET/SD H Standards D istance1 TRPE03A I1C000E12 - 5!C to +70!C Yellow 1310nm IR-1/S-1.1 21/15km TRPE03EL1C000E1 - 5!C to +70!C Red 1310nm LR-1/L-1.1 50/40km TRPE03EL2C000E1 - 5!C to +70!C W hite 1550nm LR-2/L-1.2 100/80km TRPE03A I1I000E12 - 40!C to +85!C Yellow 1310nm IR-1/S-1.1 21/15km TRPE03EL1I000E1 - 40!C to +85!C Red 1310nm LR-1/L-1.1 50/40km TRPE03EL2I000E1 - 40!C to +85!C W hite 1550nm LR-2/L-1.2 100/80km 1These are target distances to be used for classi" cation and not for speci" cation, per Telcordia G R-253-CORE/ITU -T Recommendation G .957. 2The TRPE03A I1C000E1 and TRPE03A I1I000E1 can also be used for short reach SR-1/I-1 applications. 21737-0969, Rev.A 2008-11-11