TRP1G1CS2C00000G OPLINK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 5

Technical content

Features

RevB-P .2009.06.23An Oplink Company

Oplink Communications, Inc. Transmitter Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Receiver Performance Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) TRXAG1M Single Mode Parameter Symbol Minimum Typical Maximum Units Operating Data Rate B 125 - 1250 Mb/s Optical Output Power 1 LX 2 PO - 9.0 - - 3.0 dBm EX - 4.5 - 0 YX - 2.0 - + 3.0 ZX 0 - + 5.0 Center Wavelength LX λC 1275 1310 1357 nmEX 1280 1310 1335 YX, ZX 1500 1550 1580 Spectral Width (RMS) LX ΔλRMS - - 2.5 nm Spectral Width (-20dB) EX, YX, ZX Δλ20 - - 1.0 nm Side Mode Suppression Ratio EX, YX, ZX SMSR 30 - - dB Extinction Ratio Phi/Plo 9 - - dB Deterministic Jitter DJ - - 80 ps Total Jitter TJ - - 227 ps Optical Rise/Fall Time (20% to 80%) tr , tf - - 0.32 ns Relative Intensity Noise RIN - - - 120 dB/Hz Dispersion Penalty 3 YX - - 1.2 dB ZX - - 1.5 Transmitter Output Eye Compliant with Eye Mask Defined in IEEE 802.3z and FC-PI Rev. 13 Standards 1 Measured average power coupled into single mode fiber (SMF). 2 For 50μm or 62.5μm multimode fiber (MMF) operation, the output power is 0.5dB less and is measured after a SMF offset-launch mode-conditioning patch cord as specified in IEEE 802.3z. 3 Specified at 1440ps/nm (YX) and 1600ps/nm (ZX) dispersion, which corresponds to the approximate worst-case dispersion for 72km and 80km G.652/G.654 fiber over the wavelength range of 1500 to 1580nm. Parameter Symbol Minimum Typical Maximum Units Operating Data Rate B 125 - 1250 Mb/s Minimum Input Optical Power (10-12 BER) 1 LX Pmin - 20.0 - - dBmEX - 22.5 - - YX, ZX - 24.0 - - Maximum Input Optical Power (10-12 BER) 1 Pmax - 3.0 - - dBm LOS Thresholds Increasing Light Input LX Plos+ - - - 20.0 dBm EX - - - 22.5 YX, ZX - - - 24.0 Decreasing Light Input LX Plos- - 30.0 - - EX, YX, ZX - 35.0 - - LOS Timing Delay Increasing Light Input t_loss_off - - 100 µs Decreasing Light Input t_loss_on - - 100 LOS Hysteresis - 0.5 - - dB Deterministic Jitter DJ - - 170 ps Total Jitter TJ - - 266 ps Wavelength of Operation λ 1100 - 1600 nm Optical Return Loss ORL 12 - - dB Electrical 3dB Upper Cutoff Frequency - - - 1500 MHz Stressed Receiver Sensitivity Compliant with IEEE 802.3z Standard 1 When measured with 27-1 PRBS at 125Mb/s, 1062.5Mb/s & 1250Mb/s, and at 1310nm for LX & EX, 1550nm for YX & ZX. 2 RevB-P . 2009.06.23 Please refer to page 4 for Laser Safety information

Oplink Communications, Inc. Electrical Pad Layout Host Board Connector Pad Layout Toward Bezel Toward ASIC TX GND TD- (TX DATA IN-) TD+ (TX DATA IN+) TX GND VccTX VccRX RX GND RD+ (RX DATA OUT+) RD- (RX DATA OUT-) RX GND TX GND TX Fault TX Disable MOD_DEF(2) MOD_DEF(1) MOD_DEF(0) NO CONNECTION LOS RX GND RX GND Bottom of Board (as viewed thru top of board)Top of Board TRXAG1M Single Mode RevB-P . 2009.06.233 Parameter Symbol Minimum Typical Maximum Units Input Voltage Swing (TD+ & TD-) 1 VPP-DIF 0.50 - 2.4 V Input HIGH Voltage (TX Disable) 2 VIH 2.0 - VCC V Input LOW Voltage (TX Disable) 2 VIL 0 - 0.8 V Output HIGH Voltage (TX Fault) 3 VOH 2.0 - VCC + 0.3 V Output LOW Voltage (TX Fault) 3 VOL 0 - 0.8 V 1 Differential peak-to-peak voltage. 2 There is an internal 4.7 to 10kΩ pull-up resistor to VccT. 3 Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). Parameter Symbol Minimum Typical Maximum Units Output Voltage Swing (RD+ & RD-) 1 VPP-DIF 0.6 - 2.0 V Output HIGH Voltage (LOS) 2 VOH 2.0 - VCC + 0.3 V Output LOW Voltage (LOS) 2 VOL 0 - 0.5 V 1 Differential peak-to-peak voltage across external 100Ω load. 2 Open collector compatible, 4.7 to 10kΩ pull-up resistor to Vcc (Host Supply Voltage). Parameter Symbol Minimum Typical Maximum Units Supply Voltage VCC 3.13 3.3 3.47 V Supply Current ICC - 200 300 mA MOD_DEF(0) pin 6 MOD_DEF(1) pin 5 MOD_DEF(2) pin 4 Interpretation by Host TTL LOW SCL SDA Serial module definition protocol Transmitter Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Receiver Electrical Interface (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Electrical Power Supply Characteristics (Over Operating Case Temperature, VCC = 3.13 to 3.47V) Module Definition

Oplink Communications, Inc. RevB-P . 2009.06.23 TX DATA IN+ 1µH coil or ferrite bead (<0.2Ω series resistance) 0.1 TX DATA IN- TX Disable 0.1+ 50Ω line 50Ω line 50Ω line50Ω line 1, 9, 10, 11, 14, 17, 20 0.1+ (100Ω to ground internally) to 50Ω load Vcc 3.3V RX DATA OUT+ 13

12 RX DATA OUT-

6 MOD_DEF(0)

MOD_DEF(1) MOD_DEF(2) LOS to 50Ω load R

2 TX Fault

3.3V 100 Example of SFP host board schematic TRXAG1M Single Mode Application Notes Electrical Interface: All signal interfaces are compliant with the SFP MSA specification. The high speed DATA interface is differential AC-coupled internally and can be directly connected to a 3.3V SERDES IC. All low speed control and sense output signals are open collector TTL compatible and should be pulled up with a 4.7 - 10kΩ resistor on the host board. Loss of Signal (LOS): The Loss of Signal circuit monitors the level of the incoming optical signal and generates a logic HIGH when an insufficient photocurrent is produced. TX Fault: The output indicates LOW when the transmitter is operating normally, and HIGH with a laser fault including laser end-of-life. TX Fault is an open collector/drain output and should be pulled up with a 4.7 - 10kΩ resistor on the host board. TX Fault in non-latching (automatically deasserts when fault goes away). TX Disable: When the TX Disable pin is at logic HIGH, the transmitter optical output is disabled (less than -45dBm). Serial Identification and Monitoring: The module definition of SFP is indicated by the three module definition pins, MOD_DEF(0), MOD_DEF(1) and MOD_DEF(2). Upon power up, MOD_DEF(1:2) appear as NC (no connection), and MOD_DEF(0) is TTL LOW. When the host system detects this condition, it activates the serial protocol (standard two-wire I 2C serial interface) and generates the serial clock signal (SCL). The positive edge clocks data into the EEPROM segments of the SFP that are not write protected, and the negative edge clocks data from the SFP . The serial data signal (SDA) is for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The supported monitoring functions are temperature, voltage, bias current, transmitter power, average receiver signal, all alarms and warnings, and software monitoring of TX Fault/LOS. The device is internally calibrated. The data transfer protocol and the details of the mandatory and vendor specific data structures are defined in the SFP MSA, and SFF-8472, Rev. 9.4. Power Supply and Grounding: The power supply line should be well-filtered. All 0.1μF power supply bypass capacitors should be as close to the transceiver module as possible. TRXAG1M R: 4.7 to 10kΩ Laser Safety: All transceivers are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions. Oplink Communications, Inc. DATE OF MANUFACTURE: This product complies with 21 CFR 1040.10 and 1040.11 Meets Class I Laser Safety Requirements

Oplink Communications, Inc. reserves the right to make changes in equipment design or specifications without notice. Information supplied by Oplink Commu- nications, Inc. is believed to be accurate and reliable. However, no responsibility is assumed by Oplink Communications, Inc. for its use nor for any infringements of third parties, which may result from its use. No license is granted by implication or otherwise under any patent right of Oplink Communications, Inc. © 2008, Oplink Communications, Inc. 46335 Landing Pkwy Fremont, CA 94538 T el: (510) 933-7200 Fax: (510) 933-7300 Email: Sales@Oplink.com • www.oplink.com

Ordering Information

RevB-P . 2009.06.235 Dimensions in inches [mm] Default tolerances: 1.02 8.89 1.78 1.86 47.35 .335 8.51 .54 .53 13.67 13.54

2.2 REF

56.6 1.646±.006 41.80±0.15 1.771±.008 44.98±0.20 .246±.002 6.25±0.05 .546±.008 13.87±0.20 Model Name Operation Temperature Latch Color Nominal Wavelength Optical Link Power Budget Distance 1 Oplink Order Number For Reference (OCP order number) TRP1G1CS2C00000G TRXAG1LXDBBM 5°C to +70°C Blue 1310nm 11dB min. 10km TRP1G1ES4C00000G TRXAG1EXJBNM - 5°C to +70°C Brown 1310nm 18dB min 40km 2 TRP1G1HF4C00000G TRXAG1YXHBOM - 5°C to +70°C Orange 1550nm 22dB min. 72km 3 TRP1G1JF5C00000G TRXAG1ZXIBGM - 5°C to +70°C Green 1550nm 24dB min. 80km 3 TRP1G1CS2I00000G TRXAG1LXDABM - 40°C to +85°C Blue 1310nm 11dB min. 10km TRP1G1ES4I00000G TRXAG1EXJANM - 40°C to +85°C Brown 1310nm 18dB min. 40km 2 TRP1G1HF4F00000G TRXAG1YXHCOM - 25°C to +85°C Orange 1550nm 22dB min. 72km 3 TRP1G1HF4I00000G TRXAG1YXHAOM - 40°C to +85°C Orange 1550nm 22dB min. 72km 3 TRP1G1JF5F00000G TRXAG1ZXICGM - 25°C to +85°C Green 1550nm 24dB min. 80km 3 TRP1G1JF5I00000G TRXAG1ZXIAGM - 40°C to +85°C Green 1550nm 24dB min. 80km 3 1 The indicated transmission distance is for guidelines only, not guaranteed. The exact distance is dependent on the fiber loss, connector and splice loss, and allocated system penalty. Longer distances can be supported if the optical link power budget is satisfied. 2 Assuming a total connector and splice loss of 2dB, total system penalty of 2dB and fiber cable loss of 0.35dB/km. 3 Assuming a total connector and splice loss of 2dB, total system penalty of 2dB and fiber cable loss of 0.25dB/km.