2014.04.11-A/0 Page1of4 MORNSUNGuangzhouScience&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation RTDsdetectiontypeisolatedmodule

FEATURES

l Two-wire,three-wireorfour-wirePt100/Cu50/Cu100 RTDssignalinput l Highprecisiongrade(0.2%F.S.) l High linearity (0.2%F.S.) l Isolationvoltage(2.0KVAC/60s) l Lowripple&noise: ≤30mVp-p l Extremely low temperature drift (50PPM/℃, within-40to+85 ℃.Typ.) l Industrialgrade(rangeofoperating temperature:-40to+85 ℃) l Auxiliary power: 5V/12V/15V /24V DC single powersupply l Industry standard signal output : 4~20mA/0~5V/0~10Vetc. l Low cost, Ultra-small size, Convenient to use, Highreliability l Standard DIP24(31.8*20.3*9.5mm), Meets UL94V-0flameretardantpackage TRP/CSeriestemperaturesignalisolationmoduleisahybridintegratedcircuit,itistheRTDsignalbythelevelofisolationoftemperature convertedintoastandardlinearwithtemperaturesignal.Thecircuitonthesamechipintegratesasetofmulti-channelhighisolatedDC/ DCpowersupply,Severalhigh-performancesignalisolators,andRTDlinearization,long-termcompensation,interferencesuppression circuit.EspeciallysuitableforPt100/Cu50/Cu100RTDsignalisolationconvertedintoastandardsignalisolation,Temperaturesignals transmissionandremotewithoutdistortion,TemperaturesignalacquisitionandisolatedofDCSsystemorindustrialsitePLC. Chipintegratesahigh-efficiencyDC-DC,itcanproducetwogroupswereseparatedfromeachothertotheinternalpoweramplifier inputs,modulationcircuitsupplyandOutputsofthedemodulatorcircuit,Switchingcircuit,andfiltercircuit.SMDtechnologystructureand newisolationtechnologiesallowthedevicetoachieve:power,signalinputandsignaloutput2000VACThree-terminalisolation.The productcanmeettheharshoperatingenvironmentrequirements.Suchasindustrialgradetemperature,humidityandvibration environment. TRP/CSeriestemperaturesignalisolationmoduleveryconvenienttouse,withminimalexternalcomponentstoachievePt100/Cu50/ Cu100RTDsignalisolationtransmitter.Itcanalsoachieveindustrialsitetemperaturecontrolsignalof1input2outputand1input4output functions. SelectionGuide PartNo. PowerSupplyinput(VDC) InputSignal OutputSignal IsolationPower Output(VDC) TRP16130P 24 Pt100 (0~200℃) 4-20mA None Notes:Customizationproductsareavailableifrequired. InputSpecifications Item OperatingConditions Value InputPower Supply Inputvoltage 24V ±5% Inputpower Signal,powerfullload ≤1W Powersupplyprotection Reversepolarityprotection Input Inputsignal Pt100 Inputimpedance 0~200℃ Output Specifications Item OperatingConditions Value Output Outputsignal 4~20mA Loadcapacity Voltageoutput ≥10KΩ Currentoutput@20mA ≤500Ω Loadregulation 0.050% Ripple&noise Bandwidth20MHz ≤30mVpp

2014.04.11-A/0 Page2of4 MORNSUNGuangzhouScience&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation Transmission Specifications Item OperatingConditions Value ZeroOffset None TemperatureDrift Operatingtemperaturerangeof-40to+85 °C 50PPM/℃,Typ.(100ppm/ ℃,Max.) Regulatoryfunction Full-scaleregulation Externalregulationresistor(10K) Zeroregulation Externalregulationresistor(10K) ResponseTime ≤5ms General Specifications Item OperatingConditions Value ElectricIsolation Three-terminalisolation(signalinput,signaloutputandinputpower supplyaremutuallyisolated) DegreeofIsolation testingfor1minute,leakage current<5mA,humidity<70% 2.0KVAC/60S InsulationResistance 100MΩ,500VDC(signalinputterminal,signaloutputterminalandpower supplyterminal) OperatingTemperature -40~+85℃ TransportationandStorage Temperature -50~+105℃ Max.OperatingTemperature forCasing Ta=25℃ ≤50℃ ApplicationEnvironment Thepresenceofdust,fiercevibration,impulsionandcorrosivegasmay causedamagetotheproduct PhysicalSpecifications CasingMaterial WH8100-F[1] Weight 10.3g(Typ.) CoolingMethod Freeairconvection EMCSpecifications EMI ConductedDisturbance CISPR22/EN55022 CLASSA(seeFig.3forrecommendedcircuit) RadiatedEmission CISPR22/EN55022 CLASSA EMS ElectrostaticDischarge IEC/EN61000-4-2 Contact ±4KV perf.CriteriaB EFT IEC/EN61000-4-4 Powersupplyport ±2KV (seeFig.3forrecommendedcircuit) perf.CriteriaB SurgeImmunity IEC/EN61000-4-5 Powersupplyport ±1KV (seeFig.3forrecommendedcircuit) perf.CriteriaB ApplicationPrecautions 1. Pleasereadtheinstructionscarefullybeforeuse;contactourtechnicalsupportifyouhaveanyproblem. 2. Donotusetheproductinhazardousareas. 3. UseDCpowersupplyfortheproductand220VACpowersupplyisprohibited. 4. Donotdismountandassembletheproductwithoutpermissiontoavoidfailureormalfunctionofequipment. After-salesservice 1. Ex-factoryinspectionandqualitycontrolhavebeenstrictlyconductedfortheproduct;ifthereoccursabnormaloperationorpossibility offailureofinternalmodule,pleasecontactthelocalrepresentativeorourtechnicalsupport. 2. Thewarrantyperiodfortheproductis3yearsascalculatedfromthedateofdelivery.Ifanyqualityproblemoccursundernormaluse withinthewarrantyperiod,theproductcanberepairedorchangedforfree. Appliedcircuit See ApplicationNotesforIsolatedTransmitter fordetails.

2014.04.11-A/0 Page3of4 MORNSUNGuangzhouScience&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation Design Reference 1. Productstructurediagram Signal sampling circuit VD GND Vo+ Vo- Io+ Io- RTD 10K 10K Compensation circuit Zero regulation circuit Full-scale regulation circuit Linear circuit Isolation power supplyIsolation circuit Input power Output power Full-scale regulation Zero regulation Filter circuitSignal conversion circuit Signal conversion circuit Fig.1 2. Typical application 24 1 B B NC A Io+ NC Io- NC NC NC ZA VD GND ZA1 FB1 FB2 DCS PLC A/D P C RL 10K 10K RTD Current output Zero regulation Amplitude regulation Auxiliary power supply Fig.2 Notes:NC:Noelectricalconnections. 3. Product calibration CalibrationEquipment:the0.01accuracyresistancebox,TheDCpower,Fourandahalfmultimeter. Calibrationsteps: 1)Accordancewiththeapplicationdiagramtowiring,orinstalltheproductintothecircuitboardwhichhasbeendesigned. 2)Accordingtothevalueoftheauxiliarypowersupply,connectthepower,Installadjustmentpotentiometer;theoutputofproductis connectedwiththemultimeter. 3)Accordingtothetemperaturerangeofinputtoquerytheindexingtablecorrespondingresistancevaluerange(Rlow~Rhigh). 4) Turn on the power 15 minutes. 5)TheresistanceboxissettoequalthevalueoftheresistanceRlow,adjusttheZeropotentiometersothattheoutputvaluecorresponding tozero(eg.4mA). 6) The resistance box is set to equal the value of the resistance Rhigh, adjust the Amplitude potentiometer so that the output corresponding toFull-Degree(eg.20mA). 7) In order to improve the output accuracy, please repeat several steps 5 and 6. 8)Calibrationfinished.

2014.04.11-A/0 Page4of4 MORNSUNGuangzhouScience&TechnologyCo.,Ltd.reservesthecopyrightandrightoffinalinterpretation 4.RecommendedEMCcircuit C TVS R TRP16130P 15+ 13- 24+ 23- 22- Power supply input Signal output Signal input Fig.3 Components Recommended parameters TVS SMCJ30A R 12Ω2WWirewound C 220μF/35A 4. Formoreinformationpleasefindtheapplicationnoteson www.mornsun-power.com DimensionsandRecommendedLayout Notes: 1. PackingInformationpleasereferto'ProductPackingInformation'.Packingbagnumber:58210008; 2. Unlessotherwisespecified,datainthisdatasheetshouldbetestedundertheconditionsofTa=25 ℃,humidity<75%wheninputting nominalvoltageandoutputtingratedload; 3. AllindextestingmethodsinthisdatasheetarebasedonourCompany ’scorporatestandards; 4. The performance indexes of the product models listed in this datasheet are as above, but some indexes of non-standard model productswillexceedtheabove-mentionedrequirements,andpleasedirectlycontactourtechnicianforspecificinformation; 5. Wecanprovideproductcustomizationservice; 6. Specificationsofthisproductaresubjecttochangeswithoutpriornotice. MornsunGuangzhouScience&TechnologyCo.,Ltd. Tel:86-20-38601850-8801 Fax:86-20-38601272 E-mail: info@mornsun.cn