DC100D20 SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 7

Technical content

Features

  • Ratings from 10 A to 100 A @ 100 VDC
  • LED Status Indicator
  • Relays are easily paralleled for higher-current applications
  • UL Approved, CE Compliant to EN60950-1
  • Improved SEMS screw and washer
  • Redesigned housing with anti-rotation barriers
  • MOSFET Output
  • DC control
  • EMC Compliant to Level 3
  • Epoxy Free Design
  • Optional IP20 Cover
  • PWM up to 1 kHz PRODUCT SELECTION Control Voltage 10 A 20 A 40 A 60 A 80 A 100 A 4-32 VDC DC100D10 DC100D20 DC100D40 DC100D60 DC100D80 DC100D100 Description 10 A 20 A 40 A 60 A 80 A 100 A Recommended Operating Voltage [Vdc] 1-72 1-72 1-72 1-72 1-72 1-72 Absolute Maximum Rating [Vdc] 100 100 100 100 100 100 Maximum Off-State Leakage Current @ Rated Maximum Load Current [Adc] (2)(3) 10 20 40 60 80 100 Maximum Surge Current (10msec) [Adc] 66 91 136 180 220 330 Maximum On-State Voltage Drop @ Rated Maximum On-State Resistance [RDS-ON] [mΩ] 13 12 7 6 5 4 Thermal Resistance Junction to Case (Rjc) Minimum Heat Sink for Rated Current @ 40°C Maximum Pulse Width Modulation Frequency [Hz] 5 1000 1000 900 900 700 700 SPECIFICATIONS Output Voltage (1)

www.sensata.com Page 2 Copyright © 2024 Sensata Technologies, Inc. Description DC Control Control Voltage Range 4-32 VDC Maximum Reverse Voltage -32 VDC Minimum Turn-On Voltage (6) 4 VDC Must Turn-Off Voltage 1 VDC Minimum Input Current (for on-state) 11 mA Maximum Input Current 14 mA Nominal Input Impedance Current Regulated Maximum Turn-On Time [μsec] 75 Maximum Turn-Off Time [μsec] 150 Description Parameters Dielectric Strength, Input/Output/Base (50/60 Hz) 3750 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -40 to 100 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.53 oz (72 g) Housing Material UL94 V-0 Hardware Finish Nickel Plating Baseplate Material Aluminum Input Terminal Screw Torque Range (lb-in/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (lb-in/Nm) 18-20 / 2-2.2 SSR Mounting Screw Torque Range (lb-in/Nm) 18-20 / 2-2.2 Input/Load Terminal Screw Torque Range (lb-in/Nm) (2) w/”K” option 8-10 / 0.9-1.13 Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC Humidity per IEC60068-2-78 85% non-condensing LED Input Status Indicator Green MTBF (Mean Time Between Failures) at 40°C ambient temperature (8) 21,395,130 hours (2,441 years) MTBF (Mean Time Between Failures) at 60°C ambient temperature (8) 11,545,504 hours (1,317 years) Input (1) General (1)

www.sensata.com Page 3 Copyright © 2024 Sensata Technologies, Inc. WIRING DIAGRAM * Inductive loads must be diode suppressed. Recommended Wire Sizes Terminals Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N] Input 24 AWG (0.2 mm2) / 0.2 [minimum] 10 [44.5] 2 x 12 AWG (3.3 mm2) / 3.3 [maximum] 90 [400] Output 20 AWG (0.5 mm2) / 0.518 [minimum] 30 [133] 2 x 10 AWG (5.3 mm2) / 5.3 110 [490] 2 x 8 AWG (8.4 mm2) / 8.4 [maximum] 90 [400] EQUIVALENT CIRCUIT BLOCK DIAGRAMS OUTPUT INPUT Load V V OUTPUT INPUT V V Load -DC +DC -DC Trigger Circuit Control Circuit +DC 05 10 15 20 25 30 35 MECHANICAL SPECIFICATIONS (1)

1 OUTPUT +2

4 INPUT +3

1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 0.89 [22.6] 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 1.1 [27.9] 0.49 [12.4] Mounting Hole/Slot 0.19 [4.9] DIA. 1.88 [47.6] 1.7 [43.2] 2.25 [57.3] 1.0 [25.4] 1.75 [44.5] 1.04 [26.4] (4 places) 0.93 [23.6] 1.0 [25.4] (2 places) (2 places) *Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination Hex Standoff Termination (“K” Option) (2) * * Input Current vs Input Voltage Standard Regulated “DC” Inputs DC Input Voltage Input Current (mA)

www.sensata.com Page 4 Copyright © 2024 Sensata Technologies, Inc. SURGE CURRENT INFORMATION Screw Termination, IP20

www.sensata.com Page 5 Copyright © 2024 Sensata Technologies, Inc. THERMAL DERATE INFORMATION (iii) SSR metal base plate acting as heat sink, it must be exposed to free ambient air.

www.sensata.com Page 6 Copyright © 2024 Sensata Technologies, Inc. ACCESSORIES Recommended Accessories Cover Hardware Kit Lug Terminal Thermal PadHeat Sink Part No. Thermal Resistance [ºC/W] KS101 HK1 HK4 HS501DR HS301 / HS301DR HS251 HS201 / HS201DR HS202 / HS202DR HS172 HS151 / HS151DR HS122 / HS122DR HS103 / HS103DR HS101 HS073 HS072 HS053 HS033 HS023 5.0 3.0 2.5 2.0 2.0 1.7 1.5 1.2 1.0 1.0 0.7 0.7 0.5 0.36 0.25 TRM1 TRM6 HSP-1 HSP-2 DC 100 D 40 K C H Series DC Operating Voltage 100: 1-100 VDC Control Voltage D: 4-32 VDC Rated Load Current 10: 10 Amps 20: 20 Amps 40: 40 Amps 60: 60 Amps 80: 80 Amps 100: 100 Amps Termination Blank: Screws & clamps K: Installed standoffs with (2) screws for PC Board mounting (IP00 only) Cover Blank: Not Included (IP00) C: Included (IP20) Thermal Pad Blank: Not Included H: Included ORDERING OPTIONS Example : DC100D40CH Not all part number combinations are available. Contact Technical Support for information on the availability of a specific part number. Required for valid part number For options only and not required for valid part number

www.sensata.com CONTACT US Americas +1(800) 350 2727 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2024 Sensata Technologies, Inc. Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Rev. 07/09/2024 ECN 20395 FDE-07-01 Rev. B WARNINGS GENERAL NOTES (1) All parameters at Tc=25°C unless otherwise specified. (2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps. For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Technical Support. (3) Heat sinking required, see derating curves. (4) Low current loads and high ambient temperature can affect turn-on time. (5) 8 VDC Minimum control voltage. Resistive loads only. Consider switching losses; at maximum frequency reduce to 75% output current. (6) Increase minimum voltage by 1V for operations from -20 to -40°C. (7) Decrease maximum control voltage 1.35V/°C above 80°C ambient temperature. (8) All parameters at 50% power rating and 100% duty cycle. For additional information or specific questions, contact Technical Support AGENCY APPROVALS & CERTIFICATIONS IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 E116950 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.